| 1.00 | N.S.Item Online Water Quality Monitoring System (Extractive Type) CPCB Approved | TUV Certified
Multi-Parameter Analyzer for pH, BOD, COD, TSS, Flow Detailed Specification: • Sample Flow: Recommended 0 – 5 L/min ensuring stable and continuous sample supply for accurate monitoring.
• Optical Technology: UV254 Spectroscopy with advanced double-beam full spectrum analysis for
precise detection of organic load.
• Sample Pressure: 0 – 4 Bar (0 – 1 Bar with integrated peristaltic sampling pump).
• Sample Temperature Handling: 0 – 80°C suitable for industrial and wastewater applications.
• BOD Measuring Range: 0 – 1000 mg/L with high repeatability.
• COD Measuring Range: 0 – 1000 mg/L using fast and reliable optical measurement.
• pH Range: 0 – 14 pH with temperature compensation.
• TSS Range: 0 – 1000 mg/L for accurate suspended solids measurement.
• Temperature Measurement Range: -10 to 100°C.
• Wet Part Materials: Quartz, Polypropylene,
Polyethylene, FPM (Viton), PMMA – corrosionresistant and designed for long service life.
• Measurement Interval: Configurable from 1 min to
720 min as per process requirement.
• Internal Memory: Stores up to 5000 measurement
lines (up to 16 channels) with date and time.
• Maintenance Interval: Recommended every 6
months to 1 year (except routine refilling).
• Power Supply: 90 – 264 VAC, 50/60 Hz, 40VA – 12V
DC, 3A max.
• Analog Output: 4–20 mA outputs for integration
with any PLC/SCADA.
• Display: Color TFT LCD 320x240 pixels with bright
LED backlight.
• Ingress Protection: IP65 suitable for outdoor
industrial environments.
• Communication Interface: RS232, Modbus,
HTTP/Web interface. | 1 | each | 4,10,000 ₹4,10,000 Lowest | 4,50,000 ₹4,50,000 | 4,17,736 ₹4,17,736 |
Tender Value
₹4.7 L
EMD Value
₹9,400
Closing Date
24 Feb 2026, 5:00 pmClosed
Amit Rathi
DIV Rewari
Annual maintenance estimate of 5 MLD STP at Narnaul for the year 2025-26
2026_HBC_503155_1
2026081C467B 6A47 46B2 8A4F 5FE6BC93A250258HSV
Open Tender
Civil Works
Works
30 days
Narnaul
2 documents required · 2 mandatory
₹295
₹9,400
Yes
28 Apr 2026
17 Feb 2026
25 Feb 2026
17 Feb 2026
24 Feb 2026
17 Feb 2026
N.S.Item Online Water Quality Monitoring System (Extractive Type) CPCB Approved | TUV Certified Multi-Parameter Analyzer for pH, BOD, COD, TSS, Flow Detailed Specification: • Sample Flow: Recommended 0 – 5 L/min ensuring stable and continuous sample supply for accurate monitoring. • Optical Technology: UV254 Spectroscopy with advanced double-beam full spectrum analysis for precise detection of organic load. • Sample Pressure: 0 – 4 Bar (0 – 1 Bar with integrated peristaltic sampling pump). • Sample Temperature Handling: 0 – 80°C suitable for industrial and wastewater applications. • BOD Measuring Range: 0 – 1000 mg/L with high repeatability. • COD Measuring Range: 0 – 1000 mg/L using fast and reliable optical measurement. • pH Range: 0 – 14 pH with temperature compensation. • TSS Range: 0 – 1000 mg/L for accurate suspended solids measurement. • Temperature Measurement Range: -10 to 100°C. • Wet Part Materials: Quartz, Polypropylene, Polyethylene, FPM (Viton), PMMA – corrosionresistant and designed for long service life. • Measurement Interval: Configurable from 1 min to 720 min as per process requirement. • Internal Memory: Stores up to 5000 measurement lines (up to 16 channels) with date and time. • Maintenance Interval: Recommended every 6 months to 1 year (except routine refilling). • Power Supply: 90 – 264 VAC, 50/60 Hz, 40VA – 12V DC, 3A max. • Analog Output: 4–20 mA outputs for integration with any PLC/SCADA. • Display: Color TFT LCD 320x240 pixels with bright LED backlight. • Ingress Protection: IP65 suitable for outdoor industrial environments. • Communication Interface: RS232, Modbus, HTTP/Web interface.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
BOQ_581852.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .