Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹19.9 L+₹1.4 L (7.72%)Rejected-AOC EY 04 PODA WC CHANDIGARH A I A II B I | CHANDIGARH | CHANDIGARH | 160001 | L2 | Rejected-AOC Accepted | |
| 3 | L3₹23.7 L+₹5.2 L (28.3%)Rejected-AOC 5 127 16 GANESH GARDEN KADAMPADI SULUR COIMBATORE TAMILNADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L3 | Rejected-AOC Accepted |
Tender Value
₹20.4 L
EMD Value
₹40,700
Closing Date
3 Feb 2020, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
REPAIRS REPLACEMENT OF TAMPER PROOF ENERGY METERS, FANS SUB MAIN/INTERNAL WIRING GI EARTHING GEYSERS WITH CONNECTED ACCESSORIES AT CERTAIN MD ACCNS AND SERVICING OF DG SETS OF VARIOUS CAPACITIES AND MAKES AT COIMBATORE AND MADUKKARAI ARMY AREA U
2020_MES_312033_1
8552/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Coimbatore
As per tender documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹40,700
Yes
27 Apr 2020
4 Jan 2020
5 Feb 2020
6 Jan 2020
3 Feb 2020
21 Jan 2020
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including tube light fittings, switches, ceiling roses, pendants, fan regulators, sockets etc removing material from site and keeping in safe custody for taking as schedule of credit/depositing to MES store yard and making good to the disturbed surfaces of walls, floors, roof etc all as specified and directed.
Taking down carefully sub main wiring with aluminium/ copper conductor cable 4/6/10/16 sqmm in PVC conduit complete removing materials from site and making good the disturbed surfaces of wall/ floor etc all as specified and directed.
Sub main wiring with two runs of PVC insulated multistranded copper conductor cable 4 sq. mm with one run of 4 sqmm as earth continuity including 25 mm dia PVC casing capping complete all as specified and directed. Note: 2 runs of cable, one run of earth continuity and one run of casing/ caping shall be measured as one unit length.
Point wiring with multistranded copper conductor 1.5 sq mm nominal cross-sectional area single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including PVC conduit pipe and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly completed for One light point controlled by one No. one way switch 5/6 Amps all as specified and directed
All as per item No 4 hereinbefore but One ceiling fan/exhaust fan point controlled by one No. one way switch 5/6 Amps all as specified and directed.
All as per item No 4 hereinbefore but one 3 pin 5 Amps socket outlet on independent board controlled by one 5 Amps switch with cable 1.5 Sqmm size all as specified and directed.
All as per item No 4 hereinbefore but One 3 pin 5 amps socket outlet on the same board with other switches controlled by one 5 Amps switch, with cables 1.5 sqmm size all as specified and directed.
All as per item No 4 hereinbefore but 4 Sqmm PVC insulated and PVC unsheathed copper multi stranded conductor cable and 4 Sqmm multi stranded copper conductor for earth wire for 3 pin 15 Amps power points all as specified and directed.
Switch piano flush button single pole one way. 5 amps 240 volts as per existing type and model all as specified and directed.
Socket outlet 2 in 1, 3 pin 5 Amps, 240 volts as per existing type and model all as specified and directed.
Switch piano flush button single pole one way 15/16 Amps, 240 Volts as per existing type and model all as specified and directed.
Socket outlet 2 in 1, 3 pin, 5 Amps and 15 Amps flush type, 240 volts as per existing type and model all as specified and directed.
Ceiling rose surface Bakelite three terminals 65x25mm PVC/ Polycarbonate isolated body all as specified and directed.
Lamp holder PVC/Polycarbonate type with back plate suitable for angular fitting all as specified and directed.
Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specified and directed.
LED Tube light fitting slim energy saving 1X18 Watt, connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector, fixed on wall /ceiling all as specified and as directed Make : HAVELLS Cat No LHEXBTP7IN1W018 6500K or equivalent as approved by GE
LED Tube light cool rod slim energy saving 1X20 Watt, LED 6500 K single side connection, all as pecified and as directed Make : HAVELLS Cat No LHLDEFXD5L8R020 or equivalent as approved by GE
Replacement of switch and socket outlet 2 in 1, 3 pin, 5 and 15 amps as per existing type and model all as specified and directed.
Replacement of switch and socket outlet 3 pin, 5 amps flush type as per existing type and model all as specified and directed.
Replacement of bell push, flush type 5 Amps as per existing type and model all as specified and directed.
Replacement of switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch all as specified and directed.
Replacement of socket outlet 3 pin, 5 amps flush type modular press type all as specified and directed.
Replacement of bell push, flush type 5 Amps modular press type all as specified and directed.
Replacement of switch flush type 5 Amps modular press type all as specified and directed.
Replacement of switch flush type 15 Amps modular press type all as specified and directed.
Replacement of stepped type electronic fan regulator modular press type all as specified and directed.
Replacement of bell AC multi music type 230 volt all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amps MCB complete all as specified and directed.
MCB DB, TPN 4 way suitable for three phase 240 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCBs single/ double pole including dismantling of old existing complete all as specified and directed.
MCB DB, SPN 4 way suitable for single phase 240 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCBs single/ double pole including dismantling of old existing complete all as specified and directed.
All as per item No 30 hereinbefore but SPN 8 way all as specified and directed.
All as per item No 30 hereinbefore but SPN 12 way all as specified and directed.
MCB single pole with thermal over load as well as magnetic short circuit tripping device with quick , break trip free mechanism, robust design and terminals having heat resistance moulding suitable for single phase circuit of 6 to 32 amps 'B' Series all as specified and directed.
All as per item No 33 hereinbefore but MCB DP 40 Amps all as specified and directed.
All as per item No 33 hereinbefore but MCB TPN 63 Amps all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 600X600X6mm thick buried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and incl GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and as specified or indicated and testing on completion incl excavation and earth work in any type of strata available at site ,PCC (1:3:6)type C-1 earthing chamber ,pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 mtr long, etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 mtr will be measured and paid separately
Replacement of existing Tube light LED fitting 20 watt all as specified and directed. Make : Havells Cat No. LHEXBXPNIN1W020 or equivalent in Philips, Surya, CG,
Replacement of Bed side lamp decorative ultra slim round profile LED lighting fixture with extruded polycarbonate environmental friendly energy efficient 5 w LED 6000 K all as specified and directed. Make Havells cat part No LHEXBLP7IN1W005 or equivalent to Baja, Crompton.
Taking down carefully unserviceable ceiling fan of any size from its position dismantling blades, opening the fan motor, removing of defective parts such as ball bearing, bush, burnt winding, shaft, split pin, condenser, condenser holder, shackle, re-assembling after replacement of 3 core 0.75 Sqmm ( 24/0.2mm) flexible copper cable from ceiling rose to connector, hanging in its position properly complete all as specified and directed
All as per item No 39 hereinbefore but for exhaust fan of any size all as specified and directed.
All as per item No 39 hereinbefore but for wall mounted fan of any size all as specified and directed.
All as per item No 39 hereinbefore but for pedestal fan of any size all as specified and directed.
Supply only replacement ceiling fan condenser 2.5 MFD, 240 volt, AC all as specified and directed. Make EFCOS or equivalent as approved by GE
Supply and replacement exhaust fan condenser 4.0 MFD, 240 Volt, AC all as specified and directed. Make EFCOS or equivalent as approved by GE
Supply and replacement condenser holder or metal for fixing capacitor/condenser all as specified and directed.
Supply only rubber reel with nuts, bolts and washers and split pin complete for hanging of ceiling fan of any size all as specified and directed.
Cleaning and preparing the surface of ceiling fan, wall mounted fan exhaust fan, pedestal fan, removing the grease, carbon dust over, the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number of the fan all as specified and directed.
Re-winding the motor complete with super enameled copper conductor with same size and number of turns as per old one including insulating, varnishing and pre heating for Ceiling fan 1200mm/1400mm sweep any model all as specified and directed.
All as per item No 48 hereinbefore but Exhaust fan up to 300mm sweep all as specified and directed.
All as per item No 48 hereinbefore but Exhaust fan above 300mm up to 450mm sweep all as specified and directed.
All as per item No 48 hereinbefore but wall mounted fan up to 300mm sweep all as specified and directed.
All as per item No 48 hereinbefore but Pedestal fan up to 400mm sweep all as specified and directed.
Removing the damaged and corroded exhaust fan louvers and replaced with new louvers for Exhaust fan above 300mm sweep all as specified and directed.
Removing the damaged and corroded exhaust fan louvers and replaced with new louvers for Exhaust fan above 300mm up to 450mm sweep all as specified and directed.
Removing the damaged and corroded exhaust fan blades and replaced with new blades for Exhaust fan up to 300mm sweep all as specified and directed.
Removing the damaged and corroded exhaust fan blades and replaced with new blades for Exhaust fan above 300mm up to 450mm sweep all as specified and directed.
Taking down geyser of any type and capacity for servicing and overhauling of water supply connection , de-scaling, reshaping of inner cell complete, refixing the same after repair /servicing all as specified and directed.
Supply and fix for replacement of heating element cup type 1 KW all as specified and directed.
Supply and fix for replacement of heating element triangular type 1 KW all as specified and directed.
Supply and fix for replacement of heating element 2 KW of solar water heater all as specified and directed.
Supply and fix for replacement of thermostat for geyser all as specified and directed.
LED Lumen lamp 10 watt Ball Lamp for normal holder type cool day light 230/240 AC supply complete all as specified and directed. Make : HAVELLS/ BAJAJ/ CG or equivalent Cat No.LHLDEUHEML8R010
LED Lumen lamp 9 watt Ball Lamp for normal holder type cool day light 230/240 AC supply complete all as specified and directed. Make : HAVELLS/ BAJAJ/ CG or equivalent Cat No.LHLDEUHML8R009
Horizon LED lamp 3 watt E 14 candle Lamp for normal holder type cool day light 230/240 AC all complete all as specified and directed. Make : HAVELLS/ BAJAJ/ CG or equivalent Cat No.LHLDEROEMK9X003
Energy saving LED Flood light 42 Watts with high power LEDs as light source suitable for high lighting of area including fixing arrangement all as specified and directed. Make: Havells Model No. VENUSNEOHE 2X2 Cat No. VENUSNEOHE2X2PLR42WLED8XXS or equivalent make in WIPRO / BAJAJ.
New security light fitting complete with 40 watt LED type pressure die cast aluminium housing and TOP opening separate driver compartment with IP 66, IK 07 protection and better optics for uniform distribution etc complete fixed with bracket made out of GI pipe (light grade) of suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed. Item code : ENDURAPEARLNEOSL40WLED757PASYTOPC, Item Name : ENDURAPEARL NEO or equivalent as approved by GE
Candle (filter) 10” size including taking down old unserviceable candle and fixed in repairs all as specified and directed
PCB card 12 volt DC capacity for Aquaguard incl dismantling old unserviceable card complete and fixed in repairs all as specified and directed
Carbon (filter) 12” size including taking down old unserviceable filter and fixed in repairs all as specified and directed
Replacement of ceiling fans blades (set of three) 56"/48" size make as per existing or as required complete all as specified and directed
KWH Electric meter digital display single phase Class: 1.0, 50 Hz, 5 to 30 Amp (CT operated), Temp 27 degree Celsius Marked all as specified and directed.
KWH Electric meter digital display 3 Phase four wire Class: 1.0, 50 Hz 10-40 Amp (CT operated), Volt : 3 x 240 V Marked all as specified and directed.
Security light fitting complete with 30 watt LED type pressure die casting aluminium housing with acrylic cover as diffuser with IP 66 protection, impact resistance of IK07 and heat resistant toughened glass with frame protection and better optics for uniform distribution etc complete fixed with bracket made out of GI pipe (light grade) of suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5sqmm from ceiling rose to fittings connector all as specified and directed. Item Code: ENDURAPEARL SL30WLED757SASYTOPCMP model Endura citylite platinum IP 66 Make Havells or equivalent make as approved by GE.
Spin on Filter for lubricating of capacity up to 40 KVA DG set all as specified and directed of make Kirloskar.
Spin on Filter for lubricating suitable for 10 KVA DG set all as specified and directed of make Mahindra/Mico
Primary Filter element of capacity up to 40 KVA DG set all as specified and directed of make Kirloskar
Primary Filter element suitable for 10 KVA DG set all as specified and directed of make Mahindra/ Mico
Secondary Filter element of capacity up to 40 KVA DG set all as specified and directed of make Kirloskar
Secondary Filter element suitable for 10 KVA DG set all as specified and directed of make Mahindra/Mico
Main Element for Air Cleaner of capacity up to 40 KVA DG set all as specified and directed of make Kirloskar
Main Element for Air Cleaner of capacity up to 10 KVA DG set all as specified and directed of make Mahindra
Timer 230 V of model EAPL for AMF panel all as specified and directed
Relay 230 V, 5A ,3 C/O-MPC all as specified and directed make Pla / Slazer
Charger for AMF Panel 12 V, 10 A all as specified and directed
Battery lead terminal of brass heavy duty with necessary shouldering complete all as specified and directed.
Supply and top up battery electrolyte water to maintain specific gravity all as specified and directed.
Dismantling of Self Starter from DG Sets including servicing and replacement of worn out spares and greasing complete with replacement of bushes, bearing, bendex, armature, carbon brush set, backplate etc all as specified and directed. Note : Replaced spares will be measured and paid separetely.
Armature of self starter as per original fitted in the starter of capacity up to 40 KVA DG Set all as specified and directed.
Bendex assembly of self starter as per original fitted in the starter of capacity up to 40 KVA DG Set all as specified and directed.
Carbon brush set of self starter as per original fitted in the starter of capacity up to 40 KVA DG Set all as specified and directed.
Bearing of self starter as per original fitted in the starter of capacity up to 40 KVA DG Set all as specified and directed.
Bush set of self starter as per original fitted in the starter of capacity up to 40 KVA DG Set all as specified and directed.
Bearing housing cover of self starter as per original fitted in the starter of capacity up to 40 KVA DG Set all as specified and directed.
Disconnecting inlet and outlet hose connection, cleaning and de-scaling of radiator complete using suitable chemical (MAC Solution) and injecting water with high pressure to all lines and cleaning with blower motor so as to remove all dirt in the lines complete for DG sets up to 40 KVA capacity all as specified and directed.
Radiator suitable for Mahendra Make DG set up to 30 KVA all as specified and directed
Dismantling of Alternator from DG Sets including servicing and greasing complete with replacement of worn out spares complete like Rotor, Regulator, bushing, bearing, diode, carbon brush set, etc all as specified and directed. Note : Replaced spares will be measured and paid separetely.
Rotor of Alternator as per original fitted in the DG set of capacity up to 40 KVA all as specified and directed.
Regulator of Alternator as per original fitted in the DG set of capacity up to 40 KVA all as specified and directed.
Carbon Brush of Alternator as per original fitted in the DG set of capacity up to 40 KVA all as specified and directed.
Bearing of Alternator as per original fitted in the DG set of capacity up to 40 KVA all as specified and directed.
Diode of Alternator as per original fitted in the DG set of capacity up to 40 KVA all as specified and directed.
Servicing of DG set with AMF Panel including replacement of fuel filters, oil filters, air filter element, changing oil, cleaning fuel lines, checking leakage and repairing it, replacement of exhaust manifold gasket ,checking of battery terminals, checking of gravity of batteries & filling of distilled water to batteries, checking / cleaning / descaling of radiator and filling of new coolant, checking of hose pipe set etc all as specified and directed by Engineer in Charge from manufacturer/authorized service centre for 15 KVA DG Set
All as per item No 102 hereinbefore but 10KVA capacity DG Set all as specified and directed.
All as per item No 102 hereinbefore but 30KVA capacity DG Set all as specified and directed.
All as per item No 102 hereinbefore but 40KVA capacity DG Set all as specified and directed.
K Cool Super Plus Coolant in 10 Ltrs can all as specified and directed
Draining out Engine Oil and replacement with K Oil Super in 1 Ltrs can all as specified and directed
Supply of Cotton Pack (Cotton waste) all as specified and directed
Cap for fuel tank all as specified and directed.
Belt A x 60 all as specified and directed.
Fuel filling hose all as specified and directed.
Air inlet hose all as specified and directed.
Drain pipe all as specified and directed.
Air cleaner assembly all as specified and directed.
AVR all as specified and directed.
Filter header all as specified and directed.
Oil filter assembly all as specified and directed.
Fuel pipe (pump to fuel filter) all as specified and directed.
Fuel pipe (Filter to FIP inlet) all as specified and directed.
V Belt all as specified and directed.
Exhaust silencer all as specified and directed.
Bracket air cleaner all as specified and directed.
Hose for air cleaner all as specified and directed.
Drain pipe for lubricant all as specified and directed
Exhaust pipe all as specified and directed
K C ASSOCIATES
CAK Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .