| 1 | L1₹25.3 LAccepted-AOC AT GURUDWARA SOUTH BALANDA TALCHER ANGUL ODISHA 759100 | ANUGUL | ODISHA | 759100 | L1 | Accepted-AOC TECHNO COMMERCIALLY ELIGIBLE | |
| 2 | Rejected-Technical AT PO GOPALPUR DIST SUNDARGARH ODISHA | GOPALPUR | SUNDARGARH | ODISHA | - | Rejected-Technical rejected as Bidder is NOT L1 | |
| 3 | Rejected-Technical AT BUDBIJAM PO ORIENT COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | - | Rejected-Technical rejected as Bidder is NOT L1 | |
| 4 | Rejected-Technical AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | - | Rejected-Technical rejected as Bidder is NOT L1 |
Tender Value
₹33.9 L
EMD Value
₹42,400
Closing Date
4 Mar 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer(ENM), IB Valley Area
Office of Staff Officer(ENM), IB Valley Area
Supply with fixing of GOAB switch, 11 KV, 400 Amps double break as per the added specification along with other associated works at mines of Samaleswari Open Cast Project, IB Valley Area.
2024_MCL_302017_1
MCL/GM/IBV/ENM/etender/112112 Dated.20.02.2024
Open Tender
Miscellaneous Works
Item Rate
120 days
SOCP, IB Valley Area
Please refer Tender documents.
4 documents required · 4 mandatory
₹42,400
28 May 2024
20 Feb 2024
6 Mar 2024
21 Feb 2024
4 Mar 2024
21 Feb 2024
21 Feb 2024 - 26 Feb 2024
Amount
Item Description
Supply of 11 KV, 400 AMPS, Double break GOAB switch having:- Type of Installation-Double Break, Gang Operated Outdoor Type, Horizontal Mount Standards-IS 9921 and IEC-129 Rated Voltage-11 KV, Maximum design Voltage-12 KV Frequency- 50 Hz Contineous Current Rating-400 Amps, Rated short time current:- i. For 1 Second (KA RMS)-18.42 KA, ii. Rated peak short time current(KAP)-46 KA Minimum clearance in air i. Between Poles(MM)-1050 MM(Phase to phase centre of 1300 MM) ii. Between live parts & earth(MM)-508 MM(Equivalent to Insulator Height) iii. Between live parts when switch is open: a) On the same pole(mm)-840 MM(Centre to centre of outer stacks-915 MM) b) Between adjecent poles(mm)-1050 MM Design and construction: i. No. of Insulators per pole-3 stacks per phase-11 KV, ii. No of breaks per pole-Two,iii. Type of closing/opening Mechanism-Horizontal banging type, iv. Contacts-a. Material and grade-HDE copper flat-4 MM thick, b. Cross Sectional Area(MM)-768 sq mm, c, Stainless steel spring,v. Moving blades a.Material and grade-HDE Copper tube, b. Cross Sectional Area(MM)-511 Sq MM, 2 MM Thick vi.Bearings-a.Material ans size of housing-MSHDG b.No of bearing location and size-2 nos(Thrust bearing and Bush bearing vii.Tandem Pipe-a.Size class and No of pipes-25 MM ID class B-1 no, 3.5 Mtr long each Vii. Down pipe size, class and length-38 MM NB GI Class B 2855 MM long
Installation and commissioning of GOAB Switch on overhead structure.
Supplying of two lengths of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre, 3 mtr each) double pole cross arm for installation of Double break GOAB switch complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for post top insulator pins/ fittings, bolts, nuts, washers etc and painting with primer and finish paint as required .
Supplying of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre, 2.4 mtr) for Supporting of DP Channel complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required .
Supplying and erection of a set of two 65 mm X 65 mm X 6 mm GI angle(1.5 mtr each) to support AB switch complete with 50 mm X 6mm GI flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required .
Supplying and erection of 11 KV post insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/s BIKASH ENTERPRISES
GOURI BIDYUT CONSTRUCTION
M/S LIGHT PALACE
techsummary_312867.pdf
PDF • 0.27 MB
finsummary_312867.pdf
PDF • 0.35 MB
LOA112112.pdf
PDF • 2.50 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .