Loading…
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹34.0 Cr
EMD Value
₹44.0 L
Closing Date
15 Nov 2026, 3:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer, Building Division Siwan
EE
EE, Building Division Siwan, bcd , siwan, bihar
Superintending Engineer, Building Circle Chapra
SE
Construction of 10 Court Building, Aminity Building, Hazat Building, Boundary Wall including electrification work at Sub Divisional Court, Maharajganj District-Siwan
142199
05/ET/BCD/SIWAN/2026-2027 (GROUP NO-01)
Open Tender
CIVIL
Siwan
• (a) Unconditional bank guarantee from any scheduled Indian
bank issued within the state in the format given. 1
6.1
1 Bid Security Amount in Rupees Total Bid Security A
mount in Rupees 43,95,500 IFB
• (i) Legal Status of Bidder 4.3(a)
(ii) Place of Registration.
(iii) write Principal place of Business
(iv) Power of attorney of signatory Bid
• Total value of civil engineering construction work, in Ru
pees, Performed in last five years. minimum annual financial
turnover (in all classes of civil engineering construction works
only) amount of construction work of at least the equal to the
50 % of estimated cost of works for which bid has been invite
d. The turn over will be indexed at the rate of 8% for a year
Rs. 16,97,70,726.00
4.5(A) (a)
2021-22
2022-23
2023-24
2024-25
2025-26
• Amout in Rupees related to Work Experience of Similar
nature
Satisfactory completed at least one similar work of
value not less than 50% of estimated Cost Rs. 16,97,70,726.00
4.5(A) (b)
• Minimum Quantities of work done as prime contractor in
any one year during last five years, units shall be same as in R
equirement column
Items Qty Unit
EARTH WORK 25,605.905 CUM
BRICK WORK 2,150.48 CUM
RCC/PCC 3,492.94 CUM
FLOORING 6,879.88 SQM
PHE 30,11,668.00 Rs.
ELECTRICAL 1,65,12,816.00 Rs.
FIRE FIGHTING 65,96,541.00 Rs.
FURNITURE 1,69,04,401.00 Rs.
• Electrical License The contractor or his identified sub-c
ontractor should possess required valid electrical license for e
xecuting the building electrification works and should have ex
ecuted similar electrical works for a minimum amount as indi
cated in Appendix in any one year
4.5A( d)
• (a) Amount of Existing commitments and ongoing works
in Rupees
Sec 2-1.4(A)
(b) Amount of Work for which Bid already submitted, in
Rupees
Sec 2-1.4(B)
• Maximum age and Numbers of Equipments with bidder
Type of Concrete Batching & Mixing plant Minimum capacit y 15m3/hr 5 1
Pump for concreting 5 1
Transit Mixture 5 1
Vibrator (Plate & Niddle) 5 1
Water Tanker 5 2
Steel shuttering 5 10000 sft
• Name of the Personnel and Experince in years and Select
from drop down list Personnel / Qualification 4.5(B) (b)
1 Project Manager B.E. Civil + 10 Years Exp. (5 ye ars as Manager having MBA) or equivalent or retired E.E. 1 No.
2 Site Engineer B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E. 2No
3 Plant Engineer B.E. Mech./ Civil + 03 Years Exp. or Dip. Mach + 05 Years Exp. or Retired J.E. 1 No.
4 Quantity Surveyor B.E. Civil + 03 Years Exp. or Dip. Civil + 05 Years Exp. 1 No.
5. Site Supervisor Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder. 3 Nos.
• Evidence of accesses to Financial Resources in Rupees
Evidence of access to or availability of creadit facilities (1
0% of estimated cost), certified by bankers (for work under th
is bid). 4.2(i)
• Proposed methodology and programme of construction S
elect from drop down list
the proposed methodology and
programme of construction, backed with equipment planning
and deployment 4.3(l)
• Litigation History. Select from drop down list. In
formation regarding any litigation, current or during the last fi
ve years, in which the Bidder is involved, the parties concerne
d, and disputed amount. (Attached or not) 4.3(j)
• Affidavit Select from drop down list. Regarding statements made in the required attachments are true and correct.
Sec-2, Affidavit
• Undertaking Select from drop down list. Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. Sec-2, Undertaking
• 15 Registration No.
16 IT.& GST Registration & clearance Certificate
17 Labour License
18 Character Certificate
19 NOC for Debar (If required)
• TIME OF COMPLETION 15 MONTH
CIVIL
PERCENTAGE
L1
1
24 documents required · 24 mandatory
₹10,000
Processing Fee: 11800
₹44.0 L
In the office of Superintending Engineer, Building Circle, Chhapra on dated 30.10.2026 at 11:00 AM
22 Oct 2026
22 Oct 2026
17 Nov 2026
24 Oct 2026
15 Nov 2026
24 Oct 2026
30 Oct 2026
TECHNICAL BID EVALUATION SHEET
BUILDING CONSTRUCTION DEPARTMENT
NAME OF WORK :- Construction of 10 Court Building, Aminity Building, Hazat Building, Boundary Wall including electrification work at Sub Divisional Court, Maharajganj District-Siwan
Estimated Cost: 33,95,41,452.00
SL.NO. PARTICULARS LAID DOWN CRITERIA AS PER NIT CONDITION FULL MARKS EVALUATION CRITERIA BIDDER
A Name and address of agency
B Registration no. & department Agency must be registered with Govt./State Govt./Undertakings Mandatory Agency must be registered otherwise bid will be rejected
C Sale tax/VAT/GST clearance of Govt. of Bihar Must possess sales tax/VAT registration & up to date clearance certificate Mandatory ---do------
D Income Tax clearance Must quote PAN No. Mandatory ---do------
E Earnest Money In the form as specified in N.I.T and required amount. Mandatory ---do------
F Character Certificate Must Posses Character Certificate. Mandatory ---do------
G Electrical Registration In the form as specified in N.I.T and required amount. Mandatory ---do------
Note:-The bidders should necessarily be Responsive on above mentioned Seven counts A to G. The bidders found Non-Responsive in any one of the above mentioned Seven counts will not be considered for further markings & their Bid will be rejected.
MARKING DETAILS
SL.NO. PARTICULARS LAID DOWN CRITERIA AS PER NIT CONDITION EVALUATION CRITERIA
FULL MARKS Desired distribution
1 Average annual financial turn over of last three years (AATO may be indexed as per norms of bidding documents) Submit A.T.O of Chartered account ant for last three years 30 i) AATO equal to or above BOQ amount--30
ii) AATO equal to or above 70%of BOQ amount--20
iii) AATO equal to or above 50% but below 70% of BOQ amount--15
iv) AATO equal to or above 40% but below 50% of BOQ amount--10
v) AATO equal to or above 25% but below 40% of BOQ amount--5
vi) AATO below 25% of BOQ amount--Nil
Average A.T.O.after indexation
2 Experience of doing work of similar nature Must submit details of work done duly certified by the concerned E.E 20 i)If executed single work of similar nature equal to 50% of BOQ amount-20
ii)If executed single work of similar nature equal to 40% of BOQ Amount----15
iii)If executed single work of similar nature equal to 25% of BOQ Amount----10
iv)If executed single work of similar nature below 25% of BOQ Amount----nil
3 Details of Engineering setup for successful completion of work Must submit details Engg. Setup with individual affidavit of engineers. 10 i)Engg.setup with one-Deg.holder+one Diploma holder+suff.. staff--10
ii)Engg.setup with1-Deg.holder/one Diploma holder+suff. staff--5
4 Plant and equipment for successful completion of work i)Automaticbatching plant with all equipment. (ii)Conc.mixer with weighing facility. (iii)Steelshuttering & centering more than 2000sft. (iv)Vibrator & water tanker. 10 i)Atomatic Batching plant with all equipment---10
(ii)Concrete mixer with weighing facility---04
(iii)Steel shuttering and centering more than 2000sft--04
(iv)Vibrator------01
(v)water tanker----01
5 Details of financial availability through bank or self Bank certificate of extending credit facility up to 10% of BOQ amount 10 i)credit facility certificate given by Indian Bank upto 10%of BOQ amount-----05
(ii)Self declaration----05
(iii)No Self declaration----00
6 Necessary undertakings Agency should furnish the following undertakings. (i)Not abandoned project. (ii)No litigation. (iii)No relation. 5 (i)Not abandoned any project--03
(ii)No litigation--01
(iii)No relation---01
(iv)Not submitted any certificate---00
7 Bidding capacity BC=AxNx2-B A=Max.ATO after indexation. B=value of work in hands(Existing commitment) N=Time of completion Attach bidding statements with details 10 i)BC more than or equal to BOQ amount--10
iI)BC more than or equal to 70%but below BOQ amount--5
iI)BC more than or equal to 50%but below 70% of BOQ amount--3
iii)BC below 50% of BOQ amount----nil
8 Timely completion of project Attach certificate of the concern E.E 5 i)If three or more than three projects executed in stipulated time during last five year--05
i)If less than three projects executed in stipulated time during last five year--03
i)If no projects executed in stipulated time during last five year--00
Note:- (i) Minimum qualifying marks = 50/100 for project b/w 40lakhs to 200lakhs
Bill of Quantity
Name of work :- Construction of 10 Court Building, Aminity Building, Hazat Building, Boundary Wall including electrification work at Sub Divisional Court, Maharajganj District-Siwan
Estimate of Cost :- Rs. 33,95,41,452.00
Earnest Money :- Rs. 43,95,500.00
Cost of BOQ :- Rs. 10,000.00 Time of Complition :- 15 Months
Sl. No. SR Item No. Item of Works 10 Court Building Aminity Building Hazat Building Boundary wall Road campus dev UGWT RWH Drain Fire Fighting Furrniture RWH Electric Total Quantity Unit Rate Amount (Rs.)
1 2.6.1 Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. All kinds of soil 2992.57 819.358 469.124 4,281.05 cum 314.90 1348103.00
2 2.27.1 Extra for every additional lift of 1.5m or part thereof in: All kinds of soil 743.03 201.162 117.281 34.10 1,095.58 cum 49.40 54122.00
3 2.26 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead 1309.43 433.873 281.474 740.952 36.031 2,801.76 cum 123.90 347138.00
4 2.28 Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 2838.10 872.514 460.946 50.982 13.836 24.45 41.727 4,302.55 cum 287.30 1236123.00
5 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I. 2649.89 762.822 413.727 112.409 19.19 556.354 4,514.39 sqm 283.30 1278927.00
6 4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 220.41 72.478 28.754 9.387 1.44 41.727 374.20 cum 3998.10 1496073.00
7 4.3.1 Centring and shuttering including strutting,propping etc. and removal or form work for Foundations,footings, bases Columns 9.330 9.33 sqm 211.10 1970.00
8 4.12 Extra for providing and mixing water prooding material in cement concrete work in the proportion recommended 250.000 657.458 907.46 kg 57.16 51870.00
9 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 39.750 39.75 sqm 436.60 17355.00
10 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: 0.00
i 5.9.1 Foundations, footings, bases of columns, etc., for mass concrete. 202.73 330.180 59.345 1936.116 19.440 278.177 2,825.99 sqm 211.60 597979.00
ii 5.9.2 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 185.03 52.950 142.835 2225.415 2,606.23 sqm 375.10 977597.00
iii 5.9.3 Suspended floors, roofs, landings, balconies and access platform 4956.51 1158.168 421.864 119.360 19.19 556.354 7,231.44 sqm 437.50 3163757.00
iv 5.9.4 Shelves (Cost in situ) 20.23 20.23 sqm 437.50 8851.00
v 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 6591.74 2057.929 532.480 673.186 134.230 9,989.57 sqm 404.70 4042777.00
vi 5.9.6 Columns, Pillars, Piers, Abutments, Post and struts 4120.01 1054.152 381.120 527.040 74.040 6,156.36 sqm 494.40 3043705.00
viii 5.9.7 Stairs, (excluding landings) except spiral staircases. 502.92 131.102 52.796 8.460 695.28 sqm 439.90 305853.00
viii 5.9.9 Arches,domes,vaults upto 6m span 81.69 81.69 sqm 1128.60 92195.00
ix 5.9.16.1 Edges of slabs and breaks in floors and walls : Under 20 cm wide 1687.96 601.960 124.250 68.900 2,483.07 Metre 130.20 323296.00
x 5.9.17 Cornices and mouldings 23.070 23.07 sqm 625.20 14423.00
xi 5.9.19 Wheather shade, Chajja, corbels etc., including edges. 129.60 103.193 89.985 1.620 324.40 sqm 550.90 178711.00
11 5.22 Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars 0.00
12 5.33 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength andadmixtures in recommended proportions as per IS: 9103 to accelerate,reinforcement,durability as per direction of Engineer-incharge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. 0.00
b 5.33.2.1 All work from plinth level upto floor V level. 2161.27 534.745 143.138 50.581 52.743 2,942.48 cum 5863.20 17252331.00
c 5.23 Extra for RCC work in superstructure above floor V level for each four floors or part thereof. 257.53 257.53 cum 638.20 164356.00
13 6.1.14A Brick work with bricks of class designation 100A in foundations and plinth in :Cement mortar 1:6 (1 cement: 6 coarse sand ) 22.17 22.17 cum 4819.90 106867.00
14 6.1.14C Brick work with bricks with fly ash bricks as per IS 12894(2002) & 3495 in foundation and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) cement mortar 1:6 (1 cement : 6 coarse sand) 1724.42 140.906 203.319 148.910 2.091 2,219.65 cum 4923.00 10927317.00
15 6.3C Extra for Brick work in superstructure above plinth level upto floor V level 1192.11 131.012 8.097 1,331.22 cum 842.20 1121153.00
16 6.1.14C + 6.3C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in Cement mortar 1:6 (1 cement: 6 coarse sand) Extra tor Brick work in superstructure above plinth level upto floor V cum 203.300 102.917 306.22 cum 5765.20 1765402.00
17 6.1.12C + 6.3C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth inCement mortar 1:4 (1 cement: 4 coarse sand Extra tor Brick work in superstructure above plinth level upto floor V cum 147.230 147.23 cum 5958.50 877270.00
18 6.4C Extra for brick work in superstructure above floor V level for each four floors or part thereof. 249.68 249.68 cum 638.20 159346.00
19 6.32A Honey- comb brick work 10/11.4 cm thick with bricks of class designation 100A in cement mortar 1:4 (1 cement: 4 coarse sand ) 24.79 24.79 cum 441.40 10943.00
20 8.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high loss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm 2908.64 287.976 78.640 3,275.26 sqm 4401.20 14415057.00
21 8.3.2 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work 1801.20 1,801.20 mtr 260.10 468492.00
22 8.5 Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform. Vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including rubbing,moulding and polishing of cut edges etc. complete. 45.00 45.00 each 428.20 19269.00
23 9.20.1 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including stainless steel butt hinges with necessary screws 253.58 83.832 337.41 sqm 2845.60 960140.00
24 9.23 Extra for providing lipping with 2nd class wood battens 25 mm minimum depth on all edges of shutters (Over all area of door shutter to be measured). 253.58 253.58 Sqm 401.40 101787.00
25 26.86.6 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm, modulus of elasticity 900 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for Separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made Frame size 65 x 125 mm 280.50 280.50 mtr 1182.90 331803.00
26 26.87.1 Providing and fixing factory made single extruded WPC {Wood Polymer Composite} solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives {maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N {Face) & 900N (Edge), minimum compressive strength 50 N/mm, modulus of elasticity 850 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In• Charge. {Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick 95.13 95.13 Sqm 3866.50 367820.00
27 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts,nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 336.00 244.000 580.00 each 130.80 75864.00
28 9.71.1 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete 125x64x2.50 mm 336.00 336.00 each 93.70 31483.00
29 9.96 Providing and fixing aluminium sliding door bolt anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. 0.00
30 9.97 Providing and fixing aluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. 0.00
31 9.100.1 Providing and fixing aluminium handles anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : 125 mm 354.00 84.000 438.00 each 57.10 25010.00
32 9.100.2 Providing and fixing aluminium handles anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : 100 mm 118.000 118.00 Each 50.30 5935.00
33 9.101.2 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 177.00 177.00 each 60.80 10762.00
34 9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete 127.00 127.00 each 979.50 124397.00
35 9.117.2 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete asper manufacturer’s specification and direction of Engineer-in-chargeExtruded section profile size 42x50 mm 225.450 225.45 metre 251.80 56768.00
36 9.118.3 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-incharge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. 71.888 71.89 sqm 2450.50 176162.00
37 9.147D.3 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bed of appropriate dimension. (Area of window upto 1.75 sqm up to 2.5 sqm) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 383.06 383.06 sqm 7261.90 2781743.00
38 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)etc. complete.Anodized (AC 15) aluminium 2267.100 299.700 2,566.80 kg 447.20 1147873.00
39 21.1.2.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) 192.96 192.96 kg 480.20 92659.00
40 21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness(weight not less than 10kg/sqm) 201.520 26.640 228.16 sqm 809.30 184650.00
41 21.3.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness 390.77 390.77 sqm 1115.10 435748.00
42 21.2.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides 3.02 3.02 sqm 826.90 2497.00
43 21.4.1 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete asper the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 2.00 2.00 each 2283.80 4568.00
44 21.13 Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 1.00 1.00 each 365.20 365.00
45 21.16.2 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer in-charge Powder coated minimum thickness 50 micron aluminium 4.00 4.00 each 86.60 346.00
46 9.136 Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). 43.20 43.20 mtr 1462.70 63189.00
47 9.137 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-incharge (panneling to be paid for separately). 18.90 18.90 sqm 6445.00 121811.00
48 9.138.1 Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc.,with G.I. beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-charge. With clear fire resistant glass panes 6 mm thick of approved brand, having minimum 60 minutes fire resistance 18.90 18.90 sqm 31796.30 600950.00
49 9.139 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on backside of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge,all complete. 6.00 6.00 each 7061.50 42369.00
50 10.3 Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer. 24.61 12.639 37.25 sqm 6303.40 234795.00
51 10.5.1 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer. Using M.S. angle 40x40x6 mm for diagonal braces 17.64 2.520 20.16 sqm 3653.00 73644.00
52 10.12.1 Providing and fixing steel glazed doors, windows and ventilators of standard rolled steel sections, joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6(1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal-sash putty of approved make complete including applying a priming coat of approved steel primer; excluding the cost of metal beading and other fitting except necessary hinges or pivots as required. Doors 46.91 1.080 47.99 sqm 3038.90 145837.00
53 10.15.2.1 Providing and fixing pressed steel door frame confirming IS code 351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge. Profile C 817.80 250.340 1,068.14 metre 432.60 462077.00
54 10.18 Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 300.00 97.000 20.000 417.00 each 165.40 68972.00
55 10.32.2 Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer. 642.600 642.60 sqm 114.50 73578.00
56 10.36 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). 3283.74 1633.522 4,917.26 kg 546.80 2688759.00
57 10.13B Extra for providing and fixing steel beading of approved shape and section with screws instread of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units. Steel windows 46.91 1.080 47.99 sqm 396.70 19038.00
58 9.48.1 Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. fixed to steel windows by welding 10812.19 2809.800 184.500 13,806.49 kg 144.50 1995038.00
59 9.48.2 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws 5895.730 3639.240 9,534.97 kg 161.10 1536084.00
60 9.143 providing and fixing factory made uPVC door frame made of uPVCextureded of size 65mmx 55mm with wall thickness 2.0 mm comers of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws reinforcing hinge side 11.400 11.40 metre 516.80 5892.00
61 9.142.2 35mm thick factory made solid panal pvc door Shutter , made out of single pice extruded solid pvc profiles 5mm (+0.2 mm) thick having styles & raills(except lock rail) of size 95mmx 35mmx5mm .out of 75 mm shall be flat and 20mm shall be the help of solvent and self driven self tapping screws of 125mm extrded sheet. 12.600 12.60 sqm 3856.70 48594.00
62 11.3.1 Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 35.154 35.15 sqm 289.10 10163.00
63 11.6.1 Cement plaster skirting (upto 30 cm hieght) with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement. 18 mm thick 5.648 5.65 sqm 304.15 1718.00
64 11.26.1 Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingcomplete . Base with 1:1:1 (1 lime:1 surkhi: 1 coarse sand ) / 1:4 353.638 353.64 sqm 1252.70 443002.00
65 11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 1065.90 784.046 327.992 2,177.94 sqm 795.00 1731461.00
66 11.38 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such shades except white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete. 222.924 222.92 sqm 862.40 192250.00
67 11.39 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1 st quality conforming to IS : 13755 of NITCO , ORIENT , SOMANY , KAJARIA or equivalent make in colours such as white , Ivory , Grey , Fume , Red , Brown , laid on 20 mm thick cement motar 1:4 (1 cement: 4 Coarse sand) including grouting the joints with white cement and matching pigments etc, complete. 357.01 164.402 521.41 sqm 1329.80 693374.00
68 11.41.2 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete. Size of Tile 60x60 cm 935.23 981.639 1,916.87 sqm 1638.80 3141365.00
69 11.46.2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm. 96.86 99.794 196.65 sqm 1191.80 234372.00
70 11.23.1 Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with Makrana white second quality 1505.11 1,505.11 sqm 2934.30 4416444.00
71 11.21.1.1 Providing and fixing 10 mm thick acid and / or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding, and joints filled with acid and / or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand).Acid and alkali resistant tile. 878.17 878.17 sqm 1295.70 1137845.00
72 12.38.1 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement:2 coarse sand:4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3(1 cement::3 coarse sand)as per standard design 26.698 26.70 sqm 66.00 1762.00
73 13.17.1 12 mm cement plaster 1:3 (1 Cement: 3 Coarse Sand) finished with a floating coat of neat cement 1359.371 1,359.37 sqm 203.60 276768.00
75 13.12.2 15 mm cement plaster on rough side of single or half brick wall of mix. 1:4 (1 cement : 4 coarse sand) 5493.09 1995.020 204.811 7,692.92 sqm 176.40 1357031.00
76 13.24.2 6 mm cement plaster to ceiling of mix. 1:4 (1 cement : 4 coarse sand) 5660.24 1366.887 545.789 135.533 7,708.45 sqm 125.60 968181.00
77 13.18 15 mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall 338.52 294.780 551.680 143.480 1483.610 2,812.07 sqm 229.30 644808.00
78 13.37 Extra for plastering exterior walls of height more than 10m form ground level for every additional height of 3 m or part there of 3445.06 3,445.06 sqm 44.40 152961.00
79 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 5761.17 1995.020 779.470 396.831 8,932.49 sqm 137.00 1223751.00
80 13.77A.1 Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete. As per manufacture's specifications Two or more coats on new work 18616.86 18,616.86 sqm 56.60 1053714.00
81 13.77.2 Distempering with oil bound washa ble distemper of approved brand and manufacture to give an even shade .New work (two or more coats ) over and including priming coat with cement primer 4713.214 4,713.21 sqm 102.30 482162.00
82 13.78.1 Applying one coat of cement primer of approved brand and manufacture on wall surface: Distemper primer 1905.160 1,905.16 sqm 38.60 73539.00
83 13.79.1 Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade 1208.888 1,208.89 sqm 81.20 98162.00
84 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 24378.03 6708.234 31,086.26 sqm 105.40 3276492.00
85 13.81.1 Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and softwood) 284.17 284.17 sqm 39.70 11282.00
86 13.81.3 Applying priming coat With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works 203.850 203.85 sqm 34.60 7053.00
87 13.82.1 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:New steel work (two or more coats) 766.396 203.850 325.494 1,295.74 sqm 83.50 108194.00
88 13.82.2 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:New wood work (two or more coats) 209.580 209.58 sqm 83.50 17500.00
89 13.92.1 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work 1125.690 1,125.69 sqm 86.40 97260.00
90 13.93.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shed. Two or more coats on new work 1052.51 13.500 1,066.01 sqm 84.50 90078.00
91 13.98.1 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:New steel work (two or more coats) 32.621 32.62 sqm 103.10 3363.00
92 13.116 Forming groove of uniform size from 12x12 mm and upto 25x15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. 2575.92 2153.639 1030.000 5,759.56 mtr 47.10 271275.00
93 21.1.2.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 1511.400 199.800 1,711.20 kg 447.20 765249.00
94 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed protions of W.C. kitchen and the like consisting of : 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. IVth course of 400 micron thick PVC sheet (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm 440.40 56.430 496.83 Sqm 480.60 238776.00
95 22.8.1 Providing and laying integral cement based water proofing treatment including prepatation of surface as required for treatment of roofs, balconies , terraces etc, consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water -proofing compound cleaning the surface before treatment, (b) Laying cement concrete using broken bricks / brick bats 25 mm to 100 mm size with 50 % of cement mortar 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water froofing compound conforming to IS 2545 to reuired slope and treating similary the adjoining walls upto 300 mm height including rounding of junctions, or walls ad slabs. (c) After two days of proper curing applying a secoung coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300 x 300 mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test, All above operations to be done in order and as directed and specifed by the Engineer-in-Charge.With average thickness of 120 mm and minimum thickness at khurras point to be 65 .. 267.316 161.200 428.52 sqm 850.70 364539.00
96 22.9.3 Providing and laying in situ seven course water proofing treatment with APP (AtacticPolypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 1 OOmicron HMHDPE film sandwitched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 100 grouted with cement mortar 1:3 (1 cement: 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement: 3 fine sand) and finished neat which shall be paid for separately . Ground Floor Roof Slab 161.200 161.20 sqm 648.70 104570.00
97 22.20.1 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/ sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5 cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. 3 mm thick. 1154.91 1,154.91 Sqm 472.50 545695.00
98 26.40 Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of "L" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. 646.090 646.09 sqm 729.30 471193.00
99 6.13A Brick work 7cm thick with brick of class designation 100A cement mortar 1:3 (1 cement: 3 coarse sand) in super structure 1108.80 1,108.80 Sqm 482.00 534442.00
100 12.52.2 Grading roof for water proofing treatment with Cement concrete 1:2:4(1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 86.62 86.62 cum 3932.20 340607.00
101 12.55X Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 1154.91 1,154.91 sqm 1101.60 1272249.00
102 12.39 Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement:3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. 30.00 6.000 8.000 44.00 each 189.40 8334.00
103 5.45.1 Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063) Wall Joint of 100 mm gap 143.00 143.00 mtr 4693.00 671099.00
104 5.44.1 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self – centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge .(Material shall confirm to ASTM 6063). Floor Joint of 100 mm gap 47.50 47.50 mtr 5657.70 268741.00
105 5.46.1 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s preengineered self-centering arrangement that freely rotates / moves in all directions.The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063. Roof Joint of 100 mm gap. 14.60 14.60 mtr 5281.70 77113.00
106 2.35.1 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos / Lindone emulsifiable concentrate of 20% 314.09 314.09 Litre 200.90 63101.00
107 2.37 Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termites' treatrnent(including the cost of chemical emulsion) 0.00
a 2.37.1.1 Along external wall where the apron is not provided using chemical imulsion @ 7.5 liters / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With chlorpyriphos/Lindone E.C. 20% with 1% concentration 153.70 153.70 mtr 39.90 6133.00
b 2.37.2.1 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.55 litres per linear metre including drilling and plugging holes etc. With chlorpyriphos E.C. 20% with 1% concentration 153.70 153.70 mtr 49.10 7547.00
c 2.37.3.1 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm diameter holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor With chlorpyriphos E.C. 20% with 1% concentration 1108.80 248.159 1,356.96 sqm 241.20 327299.00
108 6.47A Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l, 172.10 72.084 53.000 297.18 mtr 1087.90 323306.00
109 (Derived) from BCD SOR Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I. 199.78 199.78 cum 2141.75 427879.00
110 (Derived) from BCD SOR Providing and fixing wooden Dais all complete as per building specification and direction of E/I. 98.76 98.76 sqm 10920.00 1078459.00
111 (Derived) from BCD SOR Providing and fixing wooden Wall panelling all complete as per building specification and direction of E/I. 189.00 189.00 sqm 10432.00 1971648.00
112 (Derived) from BCD SOR Providing and fixing wooden apperance box with fencing (Size 2.10 Long x 1.50 Wide x 1.05 Mtr Hight) all complete as per building specification and direction of E/I. 10.00 10.00 each 60288.00 602880.00
113 (Derived) from BCD SOR Providing and fixing wooden witness box with fencing (Size 1.20 Long x 1.20 Wide x 1.05 Mtr Hight) all complete as per building specification and direction of E/I. 10.00 10.00 each 37956.00 379560.00
114 17.1.1 Providing and fixing white vitreous china water closet squatting pan (Indian type WC pan) with 100mm sand cast Iron P or S Trap, 10 litre low level PVC flushing cistern (of approved make) with fittings CI/MS brackets, 32 mm diameter flush pipe with fittings and clamps, over flow arrangement with specials and mosquito proof coupling of approved municipal design including painting of fittings and brackets, cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern WC pan of size 580 x 440mm with intergal type foot rests. 34.00 10.000 8.000 52.00 Each 4470.90 232487.00
115 17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid 21.000 21.00 Each 4230.00 88830.00
116 17.4.1 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern 20.000 8.000 28.00 Each 3723.20 104250.00
117 17.81 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including ntegrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern 20.00 20.00 each 14663.50 293270.00
118 17.5.1 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass lush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 18.00 18.00 each 6469.00 116442.00
119 17.7.1 Providing and fixing white vitreous china wash basin with C.I. / M.S. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 45.00 36.000 8.000 89.00 each 2764.40 246032.00
120 17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 36.000 8.000 44.00 Each 1500.00 66000.00
121 17.10.1.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board510x1040 mm bowl depth 250 mm 3.000 3.00 Each 5231.50 15695.00
122 17.28.1.2 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia 39.000 8.000 47.00 Each 101.70 4780.00
123 17.28.2.1 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia 45.00 45.00 each 104.40 4698.00
124 17.30 Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. 2.000 2.00 Each 45.30 91.00
125 17.35.1.2 Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 2.000 2.00 mtr 1036.50 2073.00
126 17.70.1 Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle t rap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 36.000 8.000 44.00 Each 325.10 14304.00
127 17.70.2 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms 45.00 45.00 each 325.10 14630.00
128 17.31 Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete. 45.00 36.000 8.000 89.00 each 1068.50 95097.00
129 17.34.1 Providing and fixing toilet paper holder: C P brass 20.00 20.00 Each 550.70 11014.00
130 17.73.1 Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle t rap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 1.000 1.00 Each 397.30 397.00
131 17.73.2 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not 170 gms. 45.00 45.00 each 424.00 19080.00
132 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. 45.00 36.000 81.00 each 204.70 16581.00
133 12.46 Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. 109.000 109.000 218.00 Each 72.00 15696.00
134 12.78 Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. 0.00
135 12.79 Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised-PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for therma expansion.(SW) 0.00
e 12.79.4.1 Single tee without door 75x75x75 mm 60.000 5.000 65.00 Each 124.20 8073.00
f 12.79.4.2 Single tee without door 110x110x110mm 90.000 10.000 100.00 Each 190.70 19070.00
136 12.80 Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete 0.00
137 12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 110 mm diameter 8.000 8.00 Each 47.90 383.00
138 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 0.00
(i) 18.7.4 32 mm nominal outer dia Pipes 457.310 60.000 517.31 meter 395.20 204441.00
(ii) 18.7.5 40 mm nominal outer dia Pipes 457.310 45.000 502.31 meter 538.40 270444.00
139 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 0.00
(i) 18.8.1 15mm nominal outer dia pipes 600.00 609.756 45.000 1,254.76 metre 278.20 349073.00
(ii) 18.8.2 20mm nominal outer dia pipes 500.00 182.920 30.000 712.92 metre 350.80 250092.00
(iii) 18.8.3 25 mm nominal outer dia Pipes 182.920 182.92 metre 463.10 84710.00
140 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 0.00
(i) 18.12.4 32mm dia nominal bore 150.00 150.00 metre 381.70 57255.00
(ii) 18.12.5 40mm dia nominal bore 200.00 200.00 metre 476.80 95360.00
(iii) 18.12.8 80 mm dia nominal bore 5.000 5.00 metre 818.20 4091.00
141 18.16 Providing and fixing brass stop cock of approved quality : 0.00
142 18.13.1 Making connection of G.I distribution branch with G.I main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete. 25 to 40mm nominal bore 25.00 25.00 Each 446.70 11168.00
143 18.17 Providing and fixing gun metal gate valve with C.I wheel of approved quality (screwed end). 0.00
(i) 18.17.1A 20 mm nominal bore 20.00 20.00 Each 465.40 9308.00
(ii) 18.17.2 32 mm nominal bore 10.00 10.00 Each 589.90 5899.00
(iii) 18.17.3 40 mm nominal bore 10.00 10.00 Each 707.30 7073.00
144 18.19.2.2 Providing and fixing gun metal non-return valve of approved quality (screwed end). 32 mm nominal bore Vertical 1.00 1.00 Each 777.90 778.00
145 18.21 Providing and fixing uplasticised PVC connection pipe with brass ions : 0.00
a 18.21.1.1 30 cm length15 mm nominal bore 36.000 4.000 40.00 Each 74.80 2992.00
b 18.21.2.1 45 cm length15 mm nominal bore 31.000 4.000 35.00 Each 85.20 2982.00
146 18.22.2 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter 1.000 1.00 Each 190.10 190.00
147 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, wi th cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 10000.00 3000.000 2000.000 15,000.00 Ltr 9.70 145500.00
148 18.58.2.1 Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid. 150mm nominal size square 100mm diameter of the inner hinged round grating. 150.00 150.00 Each 169.70 25455.00
149 18.62.4 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy aluminium rod with L.P / H.P.H.D plastic ball. 40mm nominal bore, 206mm long. Weighing not less than 690 gms 1.00 1.00 Each 653.40 653.00
150 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore 54.00 72.000 8.000 134.00 each 434.20 58183.00
151 18.50.1 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore 24.00 36.000 8.000 68.00 each 715.10 48627.00
152 18.52.1 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore 20.000 8.000 28.00 Each 594.80 16654.00
153 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS : 8931 15 mm nominal bore 117.00 117.000 16.000 250.00 each 500.40 125100.00
154 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. 45.00 36.000 8.000 89.00 each 96.80 8615.00
155 18.74.2 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length 117.00 36.000 16.000 169.00 each 108.00 18252.00
156 18.75.3 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms 2.000 2.000 4.00 Each 100.60 402.00
157 2.13.1.2 Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc.And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil. Ordinary rock : Pipes, cables etc, exceeding 80mm dia but not exceeding 300 mm dia 300.00 250.000 30.000 580.00 Metre 863.70 500946.00
158 19.6.2 Providing, laying Non pressure NP2 class (light duty) RCC Pipes with collars jointed with stiff mixture of cement mortar in the propoertion of 1:2 (1 cement : 2 fine sand) including testing and jointing etc complete. 150mm dia RCC pipe 300.00 250.000 30.000 580.00 Metre 410.70 238206.00
159 19.2.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design 150mm dia pipe 300.00 250.000 30.000 580.00 Metre 494.40 286752.00
160 19.7.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 0.00
(i) 19.7.1.1 With F.P.S. bricks (For Storm water) 40.00 20.000 4.000 64.00 each 7914.70 506541.00
161 19.8.1 Extra for depth for manholes Size 90 x 80 cm 0.00
(i) 19.8.1.1 F.P.S. bricks (For Storm water) 10.00 8.000 4.000 22.00 Metre 5660.00 124520.00
162 19.18.3 Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg 4.000 4.00 Each 6918.30 27673.00
Septic Tank 0.00
163 2.8.1 Earth work in excavation in foundation trenches or drains(not vexceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All Kinds of soil 81.90 81.900 81.900 1051.830 49.056 60.62 667.624 2,074.83 cum 360.70 748391.00
164 2.27.1 Extra for every additional lift of 1.5 m or part thereof in :Ali kinds of soil. 23.40 23.400 23.400 258.143 16.352 344.70 cum 49.40 17028.00
165 2.18.2 Close timbering over areas including strutting, shoring and packing, cavities (wherever required) etc. complete. (Measurement to be taken of the face area timbered):Depth exceeding 1.5m but not exceeding 3m. 81.90 81.900 81.900 245.70 cum 116.50 28624.00
166 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 2.93 2.926 2.926 74.457 83.24 cum 287.30 23913.00
167 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 39.00 39.000 39.000 560.580 677.58 sqm 283.30 191958.00
168 4.1.3 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) 5.85 5.850 5.850 42.044 59.59 cum 3998.10 238263.00
169 6.1.12 C Brick work with bricks with fly ash bricks as per IS 12894(2002) & 3495 in foundation and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) 20.96 20.962 20.962 6.006 68.89 cum 5116.30 352472.00
170 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) 9.19 9.188 9.188 7.87 35.44 cum 4688.30 166135.00
171 5.9 Centring and shuttering including strutting,propping etc. and removal of form for. 0.00
172 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. 0.00
a 5.22.7A Thermo-Mechanically Treated bars TMTC-500-8mm dia. 367.52 367.520 367.520 1,102.56 kg 94.50 104192.00
b 5.22.7B Thermo-Mechanically Treated bars TMTC-500-10mm dia. 551.28 551.280 551.280 1,653.84 kg 92.60 153146.00
173 13.18 + 13.36.3 15 mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall.Extra for providing and mixing water proofing material in proportion recommended by the manufacturers:15 mm cement plaster 1:3(1 cement :3 sand) 139.20 139.200 139.200 417.60 sqm 239.60 100057.00
174 19.19.4.1 Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. EHD-35 Circular shape 560 mm internal diameter 6.00 6.000 6.000 18.00 Each 1393.20 25078.00
175 19.15.2 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal\ size) as per standard designWith 20 mm diameter round bar 6.00 6.000 6.000 12.000 30.00 Each 296.30 8889.00
176 19.32.1 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 2.00 2.000 2.000 6.00 Each 33603.40 201620.00
177 Carriage of Material 0.00 0.00
178 Add Extra Cost of Cement PSC 55709.46 162.000 162.000 56,033.46 bags 8.41 471241.00
179 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres 1623.567 1,623.57 sqm 90.70 147258.00
180 16.78.2 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 243.535 243.54 sqm 1,239.40 301837.00
181 16.80. Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer- incharge. 121.768 121.77 cum 2054.3 250148.00
182 16.42 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete 324.713 324.71 cum 4,649.00 1509591.00
183 11.79 Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge: 80 mm thick c.c. paver block of M-35 grade with approved colour design and pattern. 339.878 339.88 sqm 956.40 325059.00
184 2.32 Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 13771.472 13,771.47 100 sqm 697.40 96042.00
185 2.25A Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead. 13771.472 13,771.47 cum 441.70 6082859.00
186 23.1 Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of/and manure before and after flooding trench with water (including cost of imported earth,sludge or manure). 2861.633 2,861.63 cum 44.70 127915.00
187 23.2 Supplying and stacking of good earth at site including royalty but excluding carriage (earth measusred in stacks will be reduced by 20% for payment). 5837.720 5,837.72 cum 143.50 837713.00
188 23.3 Supplying and stacking Sludge at site including royalty and carriage (Sludge measusred in stacks will be reduced by 8% for payment) 1144.653 1,144.65 cum 282.60 323479.00
189 23.4.3 Supplying and stacking a' site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment). Screened through sieve of l.S. designation 4.75 mm 1144.653 1,144.65 cum 315.80 361481.00
190 23.5 Rough dressing the trenched ground including breaking clods. 19077.557 19,077.56 100 sqm 85.90 16388.00
191 23.6 Uprooting weeds form the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. 19077.557 19,077.56 100 sqm 283.2 54028.00
192 23.7 Fine dressing the ground 19077.557 19,077.56 100 sqm 208.80 39834.00
193 23.8 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately). 8127.027 8,127.03 cum 30.10 244624.00
194 23.9 Mixing earth and sjudge or manure in porportion specified or directed. 5837.720 5,837.72 cum 20.90 122008.00
195 23.10.3 Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more tili the grass forms a thick lawn free form weeds and fit for mowing including supplying good earth if needed. In rows 5 cm apart in either direction. 19077.557 19,077.56 100 sqm 1027.4 196003.00
196 23.14 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately) 0.00 0.00
ii 23.14.2 Holes 60 cm dia And 60 cm deep 250.000 250.00 each 69.3 17325.00
197 24.1.1.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia in ordinary soil 360.000 360.00 Metre 486.8 175248.00
198 24.3.2 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc.all complete, for all depths,as per direction of Engineer -incharge. 150 mm nominal size dia 240.000 240.00 Metre 660.10 158424.00
199 24.4.2 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-incharge. 240.000 240.00 Metre 673.5 161640.00
200 24.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 19.072 19.07 cum 1343.2 25618.00
201 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 48.000 48.00 hours 916.8 44006.00
202 24.13.2 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for150 mm dia 4.000 4.00 Each 210.7 843.00
203 24.14.2 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 4.000 4.00 Each 1531.4 6126.00
204 24.15.2 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia 4.000 4.00 Each 281.80 1127.00
205 Rate Approve by SE Supplying of 2 H.P Crompton greaves or equivalent ISI mark submersible pump etc all complete job as per specification and diraction of E/I. 4.000 4.00 Each 32086 128344.00
206 18.9.5 Providing and fixing CPVC Pipe and with fitting accessories etc all complete job as per specification and diraction of E/I. 40 mm nominal outer dia Pipes 360.000 360.00 Metre 477.6 171936.00
Fire Fighting 0.00 0.00
207 1.3 a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 2850 lpm at 56 m Head 2.000 2.00 set 401826 803652.00
208 2.3 a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Drive Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with c) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 56 m Head 1.000 1.00 set 613,809.00 613809.00
209 3.3 a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 2.000 2.00 set 80,063.00 160126.00
210 4.1 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head 4.000 4.00 set 100010 400040.00
211 5.5 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Incomings 630A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0- 500V with selector switch Ammeter (0-630 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A Outgoings (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) 0.00 0.00
Main Fire Pump 200 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets Jockey Pump 100 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for 0.00 0.00
Diesel Engine Control Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons,start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine 0.00 0.00
System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 2.000 2.00 set 453,828.00 907656.00
212 6.0 Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 0.00 0.00
(i) 6.1 200 mm. dia (wall thickness = 6.3 mm) Suction header, Delivery Header, UG tank to Suction header= 5x1.5 15.000 15.00 Metre 3115.00 46725.00
(ii) 6.2 150 mm. Dia From suction header to Pump= 5x2.00, From pump to Deliver header= 5x2.5 22.500 22.50 Metre 2314.0 52065.00
213 7.0 Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 0.00 0.00
214 9.1 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal 50.000 50.00 set 7245.00 362250.00
215 10.1 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/ Stainless Steel cap and chain as required : Single headed Gunmetal 6.000 6.00 set 7245.00 43470.00
216 10.2 Supplying and fixing single headed, stainless steel ISI marked oblique pattern hydrant landing valve with 80mm dia flanged outlet complete with ABS blank cap and chain, twist release type plug and all accessories as per IS : 5290-1983 (Type-'A'). (Make : Safeguard, Kalpex, Safe Fire, S.D. Fire) 27.000 27.00 Each 5722.00 154494.00
217 11.0 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 0.00 0.00
218 12.0 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 0.00 0.00
219 14.0 Providing and fixing cast iron double flanged wafer type Non- return valve PN 1.6 of approved quality conforming to IS:5312 with C.I. wheel, bolts, nuts, washers, 3 mm thick inserion rubber gaskets complete. 0.00 0.00
220 15.1 Providing and fixing cast iron double flanged wafer type Non- return valve PN 1.6 of approved quality conforming to IS:5312 with C.I. wheel, bolts, nuts, washers, 3 mm thick inserion rubber gaskets complete. 80 mm dia 56.000 56.00 each 4325.00 242200.00
221 16.2 Providing and placing in proper position Non-percolating flexible hose (RRl type-'A' ISI marked (IS: 636) 63mm dia x 15m long complete with instantaneous type stainless steel 63mm dia. IS marked male and female coupings (IS : 903) 56.000 56.00 each 4445.00 248920.00
222 17.1 Providing , fixing, testing and commissioning of First Aid Fire Hose Reel wall mounting , swinging type complete with drum, bracket, stop valve 20 m dia. 30M long hosereel tubing with shutoof nozzle conforming to IS:8090-1976 with 5mm orifice 27.000 27.00 each 7920.00 213840.00
223 18.2 Providing and placing in proper position stainless steel 63mm dia short size branch pipes with 20mm dia nozzles wfith 63mm instantaneous coupling ISI marked (IS : 903). 27.000 27.00 each 1631.00 44037.00
224 19.3 Suppling and fixing 150mm dia way fire brigade connection of cast iron body with 3 nos SS male instantaneous inlet couplings complete with cap and chain as required for 150mm dia MS pipe connection, conforming to IS 904 as required as per specifications. 4.000 4.00 each 9071.00 36284.00
225 20.0 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 1.000 1.00 Each 17707.00 17707.00
226 21.2 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler 400.000 400.00 Each 408.00 163200.00
227 22.0 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. 9.000 9.00 Each 1442.00 12978.00
228 25.1 Supplying, installation, testing & commissioning of sprinkler flexible pipe(UL Listed) of stainless steel complete with 15 NPT on reducer threadwith maximum working pressure of 175 PSI test pressure of 875 PSI(Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head(Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete as required. 700 mm 400.000 400.00 Each 1274.00 509600.00
229 NS-1 Providing and Fixing proof cabinet of size not less than 20 x 20 x 10 Inches made out of M.S. sheet not less than 1 mm thick having central opening and 4 mm thick glazed glass doors suitable marked on the outside 'with the letters "Fire HOSE" includng necessary locking arrangement and painting in red colour. suitable to accommodate, 15 mtr long hose pipe nozzle. It shall be mounted on wall complete as required. 27.000 27.00 Each 3550.00 95850.00
230 NS-2 Providing and fixing ISI marked ABC type multipurpose Fire Extinguishers 6 Kg. Capacity, fitted with pressure guage complete in all respects, ready to use, complete installation kit. 30.000 30.00 Each 9878.40 296352.00
231 NS-3 Providing and fixing ISI marked ABC type multipurpose Fire Extinguishers 1 Kg. Capacity, fitted with pressure guage complete in all respects, ready to use, complete installation kit 40.000 40.00 Each 4166.40 166656.00
232 NS-4 Providing and fixing ISI marked CO2 type multipurpose Fire Extinguishers 4.5 Kg. Capacity, fitted with pressure guage complete in all respects, ready to use, complete installation kit. 52.000 52.00 Each 17920.00 931840.00
233 NS-5 Providing and fixing ISI marked Water type multipurpose Fire Extinguishers 9 Lt. Capacity, fitted with pressure guage complete in all respects, ready to use, complete installation kit. 16.000 16.00 Each 7056.00 112896.00
234 NS-6 Smoke Detectors 129.000 129.00 Each 3073.00 396417.00
235 NS-7 Supply, Installation , Testing and commisoning Cable 2 x 1.5 mm dia as per necessary fitting. 1000.000 1,000.00 Each 125.00 125000.00
236 NS-8 Supply , Installation , Testing and commisoning conveincionel Fire Alarm Loop Panel 2 zone as per necessary fitting . 2.000 2.00 Each 61000.00 122000.00
237 NS-9 Supply, Installation , Testing and commisoning conveincionel Fire Alarm Hooter as per necessary fitting . 16.000 16.00 Each 3800.00 60800.00
238 NS-10 Supply, Installation , Testing and commisoning conveincionel Fire Alarm Manual Call Point as per necessary fitting . 16.000 16.00 Each 5580.00 89280.00
Furniture 0.00 0.00
239 T-1 TABLE The Main table shall be of size 2400wmmx1050dmmx750hmm . Top surface of the table shall made up of MDF board duly finished with veneer and final coating of pu. The Main desk should contain in built keyboard of computer. 10.000 10.00 Each 177805.27 1778053.00
240 T-1 TABLE The Main table shall be of size 1800 wmmx900dmmx750hmm . Top surface of the table shall made up of MDF board duly finished with veneer and final coating of pu. The Main desk should contain in built keyboard of omputer.The size of back unit shall be 2215mmWx410mmDx2000mmH.The Backunit shall be made up of MDF board duly finished with veneer & final finish by PU coating. 10.000 10.00 Each 239021.74 2390217.00
241 C-1 CHAIR Dimensions W x H x D (cm) 77 x 128-137 x 77. Upholstery Material. Leather. Finish Color. Camel. Seat Height (cm) 49.9-58.9. Net Weight (kg) 32.81. 12.000 12.00 Each 97727.22 1172727.00
242 C-1 CHAIR The Cushioned seat should be made of Injection molded Plastic outer & inner. Plastic Inner should be upholstered with leatherette and moulded High Resilience (HR) Polyurethane foam of Density 45±2 kg/m3,and hardness load 16 ± 2 kgf as per IScompression.*Seat SIZE : 47.0 cm. (W) x 48.0 cm. (D) BACK ASSEMBLY: The Cushioned back should be made of PU Foam with insitu molded MS E.R.W Round Tube of size 1.9±0.03cm x 0.16 ±0.0128cm. It upholstered with Leatherette. 10.000 10.00 Each 27913.81 279138.00
243 T-2 TABLE Finnesse Table- 5026 size shall be 1500Wx750Dx750H. Table top shall be 25 mm thick plain particle board (PPB) clad with 0.6 mm thick post formed laminate and 1 mm thick backing laminated. Finnesse ERU -3616 LHS size shall be 1050Wx450Dx705H. The top of Finnesse ERU -3616 LHS shall be 25 mm thick plain particle board (PPB) clad with 0.60mm thick post formed laminated and 1 mm thick backing laminated (BDL). 10.000 10.00 Each 68462.90 684629.00
244 T-2 TABLE size shall be 1665wx900dx750h . The top panels shall be made from 25+/- 0.5 mm thick pre laminated boards as per with 20mm thick PVC edge banding on all sides. 10.000 10.00 Each 40837.94 408379.00
245 T-4 TABLE Dimensions W x H x D (cm)(1200x600x750) . The top shall be made from 25mm thick pre -laminated board.All the edges are sealed with 2 mm thick PVC edge band all round. Side panels shall be made from 25 mm thick pre- laminated paticle board . 25.000 25.00 Each 26854.33 671358.00
246 S-1 SOFA Dimensions : 206Wx90.5Dx85.5Hx45SH (Seat Height) in cm Option Available : Fabric or Leatherette PU Foam Density : 28kg per Cu.M Understructure : 1.2cm Thick hot pressed plywood which is moisture and termite proof with zig zag spring assembly. SS 202 U/S 20.000 20.00 Each 54267.83 1085357.00
247 S-2 SOFA The seat is made up of PU foam in Density 28 ±2 kg/cu.mtr with an additional top layer of supersoft PU foam in Density 32 ± 2 kg/cu, upholstered with fabric or leatherette. 2)BACK FOAM : The back is made up of PU foam in Density 28 ± 2 kg/cu. mtr with two additional top layer of supersoft foam of density 32±2 kg/cu. mtr, upholstered with fabric or leatherette. 12.000 12.00 Each 44332.48 531990.00
248 CT- TABLE Overall Size : Width : 100cm Depth : 65cm Height : 45cm TABLE LEGS METERIALS:Color :cherry, TABLE TOP MATERIALS & SIZE : (tempered Glass/ 10mm), L X W X T : 1000x650x10mm Color : clear 12.000 12.00 Each 22464.90 269579.00
249 ST-TABLE Brand Style Modern Room Type Living Room, Bedroom Finish Type Powder Coated Base Type Legs Pattern Solid Frame Material Metal Model Name Top Corner Table 10.000 10.00 Each 12676.70 126767.00
250 STR- ALMIRAH Storewel Plain shall have an overall Size-916mmWx486mmDx1980mmH with welded construction , it should have the shelf thickness of 0.7mm, back thickness of 0.8mm, Door thickness of 0.8mm. Load capacity maximum 40 kg. 24.000 24.00 Each 31494.46 755867.00
251 BOOKCASE Overall Dimensions of Book Case=914mm(W)x320mm(D)x1742mm(H) From a small library in the break room at work to a library containing technical knowledge of a domain, the 4 Door Bookcase is a multipurpose addition to your workspace. Generous in storage capacity, it effortlessly houses many books at once. It also features a cam lock to keep the contents secure and keep them well-maintain for a longer duration. The compact structure is built using CRCA steel while the doors are made of glass so one can view the title from the spine of the book without opening the case. Additionally, the bookcase has a well-protected exterior which is coated by Epoxy Polyester Powder. Moving or restructuring the layout will no be a challenge thanks to the knockdown construction of the 4 Door Bookcase. 23.000 23.00 Each 40126.27 922904.00
252 TABLE Insight 1800 W size : 1800 W x 900 D x 740 H The top shall be 25 mm thick PLB with 2 mm thick PVC Edge Beading plus the Understructure shall be having C - Frames 1.6 mm thick MS supporting the top . The Legs shall be of dia. 38.1 x 1.6 mm thick MS ERW tube . 2.000 2.00 Each 19708.29 39417.00
253 CONFERENCE TABLE Vace of 25mm thick Pre -laminated twin board of E1 P2 grade and approved shade confoming to IS-12823 :1990, Edge banded with matching 2mm thick PVC lipping .plastic ABS access flap is provided for eassy access to wires and cables . Work top is available in various shapes as shown above . It consists os 18 mm Thick Pre-laminated twin board of E1-P2 grade and approved shade. 1.000 1.00 Each 334523.18 334523.00
254 T-3 WORKSTATION Table wooden top with steel structure withwire manager pin up or white board Penta Workstation 45mm Thick Main Partition, 25mm Thick Edge Banding Table Top, 18mm Thcik Gable End 59.000 59.00 Each 107991.75 6371513.00
255 C-2 CHAIR You often set high standard for your business, why not for office chairs? Presenting the state-of-the-art chair “Kareena” from Godrej for all office needs. Now, every time when someone takes the seat for those important discussions let the chair do the talking unknowingly. Features Synchronous mechanism with multi position locking Size -66.5 CM x 58.0 CM x 88.5 CM x 45.0 CM. 200.000 200.00 Each 13913.85 2782770.00
256 C-2 CHAIR The seat and back should be made from seasoned wood and plywood. The same should be upholstered with black synthetic leather and polyurethane foam. BACK SIZE: 46.0cm. (W) X 27.0cm. (H) SEAT SIZE: 46.0cm. (W) X 40.0cm. (D)2)ARMREST TUBE: The armrest tube should be made of 0 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. M.S. E.R.W. tube and powder coated (DFT 40-60 microns). 592.000 592.00 Each 6429.91 3806507.00
257 OPTIMIZER Overall Dimension of SS1 Single Static 1 bay plus pill type (U/C + Fittings) Shall be 1200mm(W)x400mm(D)x2047mm(H). The construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS:513. Each body shall have main unit add on units (1,2,3,4,5). Finish shall be epoxy polyester powder coated thicknees of 40 microns .Shelf Contruction shall be made from CRAc steel 0/8mm thick IS:513. 4.000 4.00 Each 430141.25 1720565.00
258 NS TABLE -1 (For Canteen and lowyer's Library) Insight 1800 W size : 1800 W x 900 D x 740 H The top shall be 25 mm thick PLB with 2 mm thick PVC Edge Beading plus the Understructure shall be having C - Frames 1.6 mm thick MS supporting the top . The Legs shall be of dia. 38.1 x 1.6 mm thick MS ERW tube . 19.000 19.00 Each 19708.29 374458.00
259 NS T-3 TABLE Dimensions W x H x D (cm)1350x 750 x 750 Mayfair is an elegant and compact all-wood desk, ideal for todays performance-oriented managers. It creates value with minimalist design and is easily . 18.000 18.00 Each 24578.41 442411.00
260 NS C-1 CHAIR The seat and back should be made from seasoned wood and plywood. The same should be upholstered with black synthetic leather and polyurethane foam. BACK SIZE: 46.0cm. (W) X 27.0cm. (H) SEAT SIZE: 46.0cm. (W) X 40.0cm. (D)2)ARMREST TUBE: The armrest tube should be made of 0 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. M.S. E.R.W. tube and powder coated (DFT 40-60 microns). 257.000 257.00 Each 6429.91 1652487.00
261 NS C-2 CHAIR The seat is made of 1.2 +/- 0.1 cm thick hot pressed plywood upholstered with synthetic leather. KTS Mech 4 Position Locking, Soft touch PU Arms, Chrome-Plated arms & Pedestal, Adj Backrest. Knee tilt synchro mechanism with seat depth adjustment mechanism. 4 position locking with anti shock feature . Overall Dimensions of Chair Seat Height - min 47.5 to max 57.5cm. Height - min 103.5 to max 120.5cm. Overall Width & Depth of Chair as measured from pedestal - Width-76.0 cm and Depth-70.7 cm. 32.000 32.00 Each 23726.03 759233.00
262 NS WORKSTATION Size- 1800x3=5400x600.PARTIAL SCREENS: 18mm thk DL marker screen of 300mm ht., mounted on Studs. LEGS: Providing metal powder coated Cello leg. Dual color can be offered with Cello leg. Legs are for standard workstation height of 750mm.Modestyconsider.UNDERSTRUCTURE: Comprising of metal powder coated cross connectors between legs and legs. Made up of metal powder coated finish and the entire assemply is fixed to the worktop.WIRE MANAGEMENT: For 750 high workstations- For vertical wiremenagement, Shared legs & wire risers with cover are considere. For horizontal wiremanagement - Wire Tray with integrated power box . Access flap cover will be provided. Switch plate of (8+3 Anchor Roma) module is considered for Power and Data points. Pedestals with legs - Nova pedestal flat metal front, full ht free standing central locking of size 390 mm w x 435 mm d x 646 mm ht 3dr = 2box+1file. CPU trolley - with castors KBPT with mousetray - metal. 2.000 2.00 Each 167596.22 335192.00
263 NS BED + MATTRESS Overall Sizes: (L)2230 mm X ( W)900 mm X (H) 614 mm Description: Sheet Bed should be a plain bed used in the recovery ward. Material Specifications: Under Structure has a Higher diameter tube which should provide a sturdy understructure. Finish Specifications: Powder coating should be Bacteriostatic and thermosetting epoxy Polyester, formulated to fulfill the requirements for bacterial protection.All powder coated parts in RAL white Performance Specifications: Maximum patient load should be 135 kgThickness-Mattress: 3"+ SANDWITCH CONSTRUCTION: Round corners - YES Hitlon thickness ( MM): 60 Hitlon density (Gm/dcm3): 23 Coir(Both side) Thickness MM: 20 Density (Gm/dcm3): 70, DRC (%): 22 QUILTING - COMBINATION / LAYERS: Pilled Foam – Quilting (One Side) Thickness MM - 14 Pilled Foam Density Gm/dcm3 - 18 PU foam / EPE sheet side walling Thickness MM - 3 TOTAL MATTRESS THICKNESS-MM - 87 8.000 8.00 Each 23815.41 190523.00
264 NS TROLLY + MATTRESS Baby Crib on Trolley with Castors Overall Size L - 892 mm x W - 536 mm x H - 1008 mm Material Specification MS E.R.W. Tube Castors High endurance Plastic injection moulded castors Mattress for Crib 50mm thick. FOAM Density: 40±2 kg/m3 & Hardness in Kg: 45±2 as per IS:7888 for 25% Compression. UPHOLSTRY Stitched Upholstry Cover Material: Helium Heavy A/F F/R SM Color: Navy Blue (350 GSM, 0.45 THK) with Fire Retardent and Antimicrobial Properties 10.000 10.00 Each 20228.22 202282.00
265 NS ALMIRAH KD Plain shall have an overall size of 900mm(W)x450mm(D)x1830mm(H) . The construction shall be rigid knock down construction and Material used shall be prime quality CRCA steel - panels from 0.6 mm thick & front frame . Shelf shall be 0.8 mm thick .Configuration (Door) shall be full height steel hinged door . Locking shall be Plastic Recessed Handle cum Cam lock with 3 way locking mechanism with shooting bolt arrangement . Height wise adjustable shelf mounting , Uniformly distributed load capacity per each full shelf shall be 80 Kg maximum . For Plain 4 Nos. of adjustable full shelves . The top shall be metal and Epoxy Powder coated finish to the thickness of 50 microns . 107.000 107.00 Each 24673.24 2640037.00
266 NS TABLE -T-4 WORKSTATION Penta Workstation 45mm Thick Main Partition, 25mm Thick Edge Banding Table Top, 18mm Thcik Gable End Table wooden top with steel structure withwire manager pin up or white board 10.000 10.00 Each 107991.75 1079918.00
267 Carriage of Material 0.00 0.00
Total amt sechudle item ₹ 261,137,053.00
Apply Correction Factor @ 0.982(B) ₹ 256,436,586.00
Electrification work
PART 'A':- 10 Court Building
269 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I. box etc as required.
Batten Holder Point = 187
Tube Light Point =256
Led Suspended Light= 172
Down Light Point = 353
Ceiling Fan Point (BLDC Fan)= 149
Wall Fan Point = 68
Bulk Head Point = 18
Call Bell Point = 20
Exhaust Fan Point = 49
270 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 190 190 Each 414.00 ₹ 78,660.00
271 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 116 116 Each 531.00 ₹ 61,596.00
272 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 2088 2088 Meter 309.00 ₹ 645,192.00
273 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire for CKT 3816 3816 Meter 201.00 ₹ 767,016.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (for Comp + 2 no 5A Socket) 3528 3528 Meter 246.00 ₹ 867,888.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (for Street Light) 240 240 Meter 246.00 ₹ 59,040.00
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire for AC Wiring 1170 1170 Meter 309.00 ₹ 361,530.00
1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (for SPN DB) 24 24 Meter 422.00 ₹ 10,128.00
1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire (Light DB) 658 658 Meter 660.00 ₹ 434,280.00
1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire (Power DB) 310 310 Meter 925.00 ₹ 286,750.00
1.7.13 4 X 16 sq. mm + 1 X 16 sq. mm earth wire (for Each Light & Power panel)( Gr to 1st ,2nd,3rd, 4th,5th) 159 159 Meter 1,312.00 ₹ 208,608.00
1.7.12 4 X 10 sq. mm + 1 X 10 sq. mm earth wire (For Main to 5th Floor Power Panel) 31 31 Meter 925.00 ₹ 28,675.00
274 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 732 732 Each 64.00 ₹ 46,848.00
275 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. 187 187 Each 80.00 ₹ 14,960.00
276 1.25 Supplying and fixing stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 149 149 Each 358.00 ₹ 53,342.00
277 1.38 Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required. 20 20 Each 351.00 ₹ 7,020.00
278 1.57 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required. 126 126 Each 1,064.00 ₹ 134,064.00
279 1.56 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 nos. 5 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. 70 70 Each 778.00 ₹ 54,460.00
280 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 74 74 Each 683.00 ₹ 50,542.00
281 5.3 Supplying and fixing 4'X20 watt LED batten with minimum efficacy 100 lm/w in aluminium housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. (For Non-residential building) 256 256 Each 762.00 ₹ 195,072.00
282 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
283 5.10 Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. 18 18 Each 1,275.00 ₹ 22,950.00
284 5.6 Supplying and fixing following types aluminium extruded suspended type LED luminaire with minimum efficacy 100 lm/w ensuring uniform and continuous illumination including suspension system complete with electronic driver etc and connection with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
285 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
286 DSR 9.2 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 149 149 Each 2,695.00 ₹ 401,555.00
287 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep 49 49 Each 2,572.00 ₹ 126,028.00
288 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.6 8 way, Double door (for Building Light +Bulkhead Light) 2 2 Each 2,591.00 ₹ 5,182.00
289 8.19 Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required. 68 68 Each 3,670.00 ₹ 249,560.00
290 2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.1 4 way ( 4 + 12 ), double door, horizontal type 55 55 Each 4,184.00 ₹ 230,120.00
291 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
292 8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) 192 192 Sq.ft 1,809.00 ₹ 347,328.00
293 AR S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. 120 120 P/Kg 871.00 ₹ 104,520.00
294 2318 Supply of Pilot lamp for indicator 42 42 Each 121.00 ₹ 5,082.00
295 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 14 14 Each 6,536.00 ₹ 91,504.00
296 2.4 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
2.4.2 125 A, 36 KA, FPMCCB (for Light Panel) 5 5 Each 8,676.00 ₹ 43,380.00
2.4.3 160 A, 36 KA, FPMCCB (For Power) 9 9 Each 13,698.00 ₹ 123,282.00
2.4.3 160 A, 36 KA, FPMCCB (For Light) 6 6 Each 13,698.00 ₹ 82,188.00
2.4.7 400 A, 50 KA, FPMCCB (For Main, Power & Light Panel) 4 4 Each 45,651.00 ₹ 182,604.00
297 2.7 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
2.7.9 400 A (for Light Panel) 1 1 Each 34,409.00 ₹ 34,409.00
298 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.8 40 A to 63 A, TP&N (Including Spare) 68 68 Each 2,329.00 ₹ 158,372.00
299 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.15 240 sq. mm, 3.5 core (Main Panel to Power +Light Panel) 24 24 p/mtr. 2,228.00 ₹ 53,472.00
300 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.4 Above 185 sq. mm and upto 400 sq. mm 120 120 Metre 368.00 ₹ 44,160.00
301 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
302 5.15 Supplying and fixing following types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
303 8.4 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
304 3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 3 3 Set 16,675.00 ₹ 50,025.00
305 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 3 3 Set 13,721.00 ₹ 41,163.00
306 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.(for Ground to Each Floor Panel) 195 195 Metre 144.00 ₹ 28,080.00
LIGHTINING ARRESTER
307 4.1 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong on top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. 6 6 Each 1,056.00 ₹ 6,336.00
308 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 30 30 Each 81.00 ₹ 2,430.00
309 4.5 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) 120 120 Metre 516.00 ₹ 61,920.00
310 4.6 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 140 140 Metre 559.00 ₹ 78,260.00
311 4.11 Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuk nuts and spring washers etc. complete as required. 24 24 Each 274.00 ₹ 6,576.00
312 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 12 12 Set 13,721.00 ₹ 164,652.00
313 3.9 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) 120 120 Meter 133.00 ₹ 15,960.00
314 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Battan Holder 6 6
Tube Light Point 3 3
Bulk-Head point 15 15
Exhaust fan point 3 3
315 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 3 3 Each 414.00 ₹ 1,242.00
316 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 3 3 Each 531.00 ₹ 1,593.00
317 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 27 27 Meter 309.00 ₹ 8,343.00
318 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 54 54 Meter 201.00 ₹ 10,854.00
1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire 5 5 Meter 925.00 ₹ 4,625.00
319 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.7 12 way, Double door 3 3 Each 2,314.00 ₹ 6,942.00
320 2.12 S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for including loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
2.12.1 6/32 amps, single pole 9 9 EACH 237.00 ₹ 2,133.00
321 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 6 6 Each 64.00 ₹ 384.00
322 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. 6 6 Each 80.00 ₹ 480.00
323 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.4 9/10 watt LED lamp 6 6 EACH 161.00 ₹ 966.00
324 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
325 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 3 3 Each 521.00 ₹ 1,563.00
326 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
327 5.10 Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. 15 15 Each 1275.00 ₹ 19,125.00
328 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 6 6 Set 13,721.00 ₹ 82,326.00
329 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 150 150 Meter 144.00 ₹ 21,600.00
330 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
331 7.4 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
7.4.1 Upto 35 sq. mm (Clamped with 1 mm thick saddle) 180 180 Meter 43.00 ₹ 7,740.00
332 AR Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD). All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis. Conforming to NBC/statutory norms and fulfilling following requirements
(i) Type : Passenger Lift
(ii) Load : As Specified
(iii) (iii) Speed: 1.00 metre/sec.
(iv) (iv) Control: ACV3F, 32bit microprocessor integrated serial communication control system with RMS (remote monitoring system) /BMS (building monitoring system) supporting software.
(v) Motor/machine: Permanent magnetic synchronous gearless motor.
(vi) Operation: Simplex collective selective with/without lift attendant.
(vii) Total rise: About 3 mtrs. (approx) between two stops.
(viii) Landings: All floors on same side.
(ix) Floors served: As Specified
(x) Signal : Digital Car position indicator, car travel direction indicator inside car & at all landings, voice annunciator with suitable music shall be provided in the lift car.
(xi) Shaft size: As per manufacturer's design and as per CPWD specification (Part III LIFTS), Shaft to be constructed separately.
(xii) Guide rail: As per manufacturer's specification. (xiii) Lift & car size: As per manufacturer's design and as per CPWD specification
(xiii) Lift & car size: As per manufacturer's design and as per CPWD specification (Part III LIFTS )
(xiv) Car entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xv) Landing entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xvi) Car door: S.S. (stainless steel) hairline finish centre /telescopic opening door.
(xvii) Landing door: S.S. (stainless steel) hairline finish centre/telescopic opening door.
(xviii) Door operation: Automatic electric power operated door, full height infrared curtain with multiple criss/cross light beams.
(xix) Car interior: S.S. (stainless steel) panel with hair line finish on all sides.
(xx) Car floor: Anti skid PVC flooring on heavy duty M S (mild steel) platform.
(xxi) Car ceiling & lighting: S. S. (stainless steel) finish with aesthetic appearance with LED ceiling lights
(xxii) Carventilation: Pressure fan/blower fan (car fan with automatic sleep timer shall be provided)
(xxiii) Emergency lighting in car: Battery operated emergency lighting in the lift car.
(xxiv) Intercom system: Battery operated intercom system in lift car, machine room and ground floor/control room
(xxv) Emergencyalarm: Battery operated alarm bell system in lift car & control room ground floor
(xxvi) Position of machine room: Directly above the hoistway.
(xxvii) Electric power supply: AC 415 V, 3 phases 50 Hz & AC 230 V Iphase 50Hz terminated in machine room.
(xxviii) Fire man switch: Fire man switch at machine room/terminal landing
(xxix) All car panel buttons and all floor switches must be with Braille language as per lift act.
(xxx) Audio visual indication in the lift car showing overloading shall be provided such that doors keep open till excess load is removed.
(xxxi) Spring buffer/hydraulic buffer shall be provided
(xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided.
(xxxii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc.
(xxxiv) In the hoist way fascia plate shall be provided.
(xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the department, machine room or at desired level.
(xxxvi) Car top safety barricade shall be provided.
(xxxvii) ARD (automatic rescue device): Solid state inbuilt automatic rescue device (ARD) automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure, capable of moving the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure.
(Make:- OTIS/ KONE/ SCHINDLER/MITSHUBISHI/JOHNSON/ THYSSENKRUPP) with 3 years free maintenance during DLP Period.
333 Operation of Lift for 1st year including 3rd party inspection charge. 3 3 Year 194,100.00 ₹ 582,300.00
334 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
335 1.27.1 Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required 55 55 Each 234.00 ₹ 12,870.00
336 1.24.6 Supply and Fixing Modular type 2 Pin Telephone Socket for Speaker Outlet on the existing modular plate & box including making connection, excluding modular plate etc as required 55 55 Each 131.00 ₹ 7,205.00
337 1.16.2 Supplying and Drawing 2 pair 0.5 sq mm. FR PVC insulated copper conductor telephone cable through existing PVC concult including connection etc as required. 2500 2500 P/Mtr. 31.00 ₹ 77,500.00
Computer Networking (LAN)
338 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
339 1.27.1 Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell ) 140 140 Each 234.00 ₹ 32,760.00
340 DSR 39.13 Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
39.13.1 Copper Patch Cords of length 1m (3ft) 140 140 Each 173.00 ₹ 24,220.00
39.13.2 Copper Patch Cords of length 3m (10ft) 140 140 Each 405.00 ₹ 56,700.00
341 DSR 39.23.1 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
342 DSR 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 8 8 Each 5,278.00 ₹ 42,224.00
343 NS Supply, Installation, Testing & Commissioning of Ethernet Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP) 8 8 Each 20,758.00 ₹ 166,064.00
344 NS Supply installation testing & commissioning of Ethernet Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link) 8 8 Each 19,070.00 ₹ 152,560.00
345 1.58 Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
346 NS Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. ) 140 140 Each 545.00 ₹ 76,300.00
( SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM)
347 DSR 17.1 Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required 50 50 KWP 54,280.00 ₹ 2,714,000.00
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase,4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.
c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and otheraccessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Meta OxideVaristors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.
f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required.
AUTOMATIC FIRE ALARM & DETECTION SYSTEM
348 DSR 28.2 Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
DSR 28.2.1.2 Two Loop Panel 1 1 Each 250,420.00 ₹ 250,420.00
DSR 28.2.3 Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 2 2 Each 113,734.00 ₹ 227,468.00
DSR 28.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 220 220 Each 3,004.00 ₹ 660,880.00
DSR 28.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 50 50 Each 306.00 ₹ 15,300.00
DSR 28.2.6 Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. 22 22 Each 2,787.00 ₹ 61,314.00
DSR 28.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required 22 22 Each 3,434.00 ₹ 75,548.00
DSR 28.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required 22 22 Each 3,156.00 ₹ 69,432.00
DSR 28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 22 22 Each 4,063.00 ₹ 89,386.00
Part A Total Total Rs. ₹ 23,020,508.00
PART 'B':- Hazat Building (G+1)
349 1.31 Wiring for light point/fan point /exhaust fan point/call bell point with 1.5sq mm FR PVC insulated copper conductor S/C cable in surface/recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I box etc. as required.
light point- 56
Ceiling Fan-20 (BLDC Fan)
350 1.31 Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As required. 8 8 EACH 414.00 ₹ 3,312.00
351 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd. 2 2 EACH 531.00 ₹ 1,062.00
352 1.17 Wiring for circuit/submain wiring along with earth wire with the following size of FR PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
2 X 4.0 sqmm + 1 X 4 sqmm earthwire 30 30 P/M 309.00 ₹ 9,270.00
2 X 6sqmm + 1 X 6 sqmm earthwire 40 40 P/M 422.00 ₹ 16,880.00
353 2.8 S/F following way single pole & neutral, sheet-steel, MCB DB - 240 V on surface / recessed, complete with tinned copper busbar, neutral busbar, earthbar, dinbar, interconnections, powder-painted including earthing etc as required.(But without MCB/RCCB/Isolator)
2.8.6 2+8 way, double door 2 2 EACH 2591.00 ₹ 5,182.00
354 2.15 S/F following rating, double pole, 240 volts, isolator in the existing MCB DB omplete with connections testing and commissioning etc as required.
355 2.12 S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for including loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
2.12.1 6/32 amps, single pole 12 12 EACH 237.00 ₹ 2,844.00
356 1.33 Supplying and fixing 2 pin, 6 amps ceiling rose on the existing junction box / wooden block including connection etc as required. 14 14 EACH 64.00 ₹ 896.00
357 1.25 Supplying and fixing stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. As required. 20 20 EACH 358.00 ₹ 7,160.00
358 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
359 5.9 Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 20 20 Each 2,663.00 ₹ 53,260.00
360 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
2.1.3 63 Amp, double pole 1 1 Each 4463.00 ₹ 4,463.00
361 2.5 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
362 2.6 Providing and fixing following capacity double pole/ four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required.
363 DSR 9.2 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 20 20 Each 2,695.00 ₹ 53,900.00
364 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep 8 8 Each 2,572.00 ₹ 20,576.00
365 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
366 7.1 Laying of one number pvc insulated and pvc sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, and refiling the trench etc. as reqd.
367 3.2 Earthing with G.I earth pipe 4.5 mtr. Long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal /coke and salt as required. 1 1 P/SET 6323.00 ₹ 6,323.00
368 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 20 20 P/M 144.00 ₹ 2,880.00
369 5.13.1 Supplying & fixing 40/45 watt LED type flood light with die cast 0 aluminium housing for ingress protection of IP65 and complete with all accessories etc. and connection with FR pvc insulated copper conductor cable and earthing the body etc. As reqd. 6 6 EACH 3382.00 ₹ 20,292.00
370 8.4 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/foundation (during casting )for cable entry including bending the pipe to the required shape complete as required.
Part B Rs. Total ₹ 456,558.00
PART 'C':- Aminity Building (G+4)
371 1.3 Wiring for light point/fan point /exhaust fan point/call bell point with 1.5sq mm FR PVC insulated copper conductor S/C cable in surface/recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I box etc. as required.
2'x2' LED Light 179 179
Down Light Point 108 108
Bulk Head Point 12 12
Ceiling Fan Point (BLDC Fan) 126 126
120 watt LED Street Light 8 8
Exhaust Fan Point 18 18
372 1.31 Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As required. 74 74 Each 414.00 ₹ 30,636.00
373 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd. 64 64 Each 531.00 ₹ 33,984.00
374 1.57 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required. 28 28 Each 1,064.00 ₹ 29,792.00
375 1.56 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 nos. 5 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. 12 12 Each 778.00 ₹ 9,336.00
376 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 37 37 Each 683.00 ₹ 25,271.00
377 1.7 Wiring for circuit/submain wiring along with earth wire with the following size of FR PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
1.7.2 2 X 2.5 sqmm + 1 X 2.5 sqmm (for st / lt & bulk head) 245 245 P/Mtr. 246.00 ₹ 60,270.00
1.7.3 2 X 4 sqmm + 1 X 4 sqmm earthwire ( power & A.C) 1830 1830 P/Mtr. 309.00 ₹ 565,470.00
1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (for SPN DB) 30 30 Meter 422.00 ₹ 12,660.00
1.7.13 4 X 16 sq mm + 1 X 6 sq mm (for VTPN to Main panel) 100 100 P/Mtr. 1,312.00 ₹ 131,200.00
378 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
379 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.6 8 way, Double door (for Building Light +Bulkhead Light) 2 2 Each 2,591.00 ₹ 5,182.00
380 2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required .(but without MCB/RCCB/Isolator)
2.9.1 4 way(4+12) double door horizontal type 20 20 Each 4,184.00 ₹ 83,680.00
381 2.16 supplying and fixing four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing commissioning etc. As reqd.
382 2.12 S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for including loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
2.12.6 40 amps, single pole & neutral (for st/lt, bulk head) 2 2 Each 1,233.00 ₹ 2,466.00
383 2.33 Supplying and fixing following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as Incomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBs)
2.33.2 6 way, Double door, I/C 160A, MCCB 4 4 Each 13,710.00 ₹ 54,840.00
384 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
385 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole (for Building Light +Bulkhead Light) one Spare 3 3 Each 1,198.00 ₹ 3,594.00
386 2.4 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. As reqd.
2.4.6 250 A, 50 KA, FPMCCB (for Light + Power Panel) 4 4 Each 19,613.00 ₹ 78,452.00
2.4.3 160 A, 36 KA, FPMCCB (One Spare) 3 3 Each 13,698.00 ₹ 41,094.00
2.4.2 125 A, 36 KA, FPMCCB (One Spare) 3 3 Each 8,676.00 ₹ 26,028.00
2.4.1 100 amp, 30 KA for Lift (One Spare)) 2 2 Each 8,172.00 ₹ 16,344.00
387 2.7 P/F following capacity 4 pole on load/panel mounted changeover switches inside the existing cubical pannel board including drilling holes in cubical panel, making connections etc as required.
2.7.8 320 A 4 pole ( In Main panel) 1 1 Each 30,787.00 ₹ 30,787.00
2.7.7 250 A 4 pole ( In Main panel) 1 1 Each 21,415.00 ₹ 21,415.00
388 A/R S/F 50 mm x 5mm copper strip (2.30 kg /mtr) for busbar as required. 30 30 p/kg 871.00 ₹ 26,130.00
389 2318 Supply of Pilot lamp for indicator 6 6 Each 121.00 ₹ 726.00
390 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 3 3 Each 6,536.00 ₹ 19,608.00
391 8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) 45 45 Sq.ft 1,809.00 ₹ 81,405.00
392 3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 2 2 Set 16,675.00 ₹ 33,350.00
393 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 2 2 Set 13,721.00 ₹ 27,442.00
394 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 80 80 Metre 144.00 ₹ 11,520.00
395 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.12 120 sq. mm, 3.5 core (for Main to Sub-Panel) 20 20 Metre 1,186.00 ₹ 23,720.00
7.7.14 185 sq. mm, 3.5 core for Main Panel 150 150 P/Mtr. 1,763.00 ₹ 264,450.00
396 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.3 Above 95 sq. mm and upto 185 sq. mm 125 125 Metre 336.00 ₹ 42,000.00
397 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
398 5.9 Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 179 179 Each 2,663.00 ₹ 476,677.00
399 DSR 9.2 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 126 126 Each 2,695.00 ₹ 339,570.00
400 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep 18 18 Each 2,572.00 ₹ 46,296.00
401 5.10 Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. 12 12 Each 1,275.00 ₹ 15,300.00
402 1.25 Supplying and fixing stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 126 126 Each 358.00 ₹ 45,108.00
403 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/ w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/ building including connection earthing the body etc as required. (120 watt) 8 8 Each 6,654.00 ₹ 53,232.00
404 8.4 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/foundation (during casting )for cable entry including bending the pipe to the required shape complete as required.
405 8.7 Supplying and fixing of light class G.I. Pipe of 80 mm dia. (nominal) 3 meters length along with pole for protection of under ground cable as required. 2 2 Each 3,658.00 ₹ 7,316.00
406 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 30 30 Meter 144.00 ₹ 4,320.00
407 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 m long etc. with charcoal /coke and salt as required. 2 2 Each 13,721.00 ₹ 27,442.00
LIGHTINING ARRESTER
408 4.1 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong on top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. 4 4 Each 1,056.00 ₹ 4,224.00
409 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 20 20 Each 81.00 ₹ 1,620.00
410 4.5 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) 100 100 Metre 516.00 ₹ 51,600.00
411 4.6 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 80 80 Metre 559.00 ₹ 44,720.00
412 4.11 Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuk nuts and spring washers etc. complete as required. 16 16 Each 274.00 ₹ 4,384.00
413 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 8 8 Set 13,721.00 ₹ 109,768.00
414 3.9 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) 120 120 Metre 133.00 ₹ 15,960.00
415 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Battan Holder 2 2
Tube Light Point 2 2
Bulk-Head point 5 5
Exhaust fan point 1 1
416 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 1 1 Each 414.00 ₹ 414.00
417 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 1 1 Each 531.00 ₹ 531.00
418 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 15 15 Meter 309.00 ₹ 4,635.00
419 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 25 25 Meter 201.00 ₹ 5,025.00
1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire 5 5 Meter 925.00 ₹ 4,625.00
420 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.7 12 way, Double door 1 1 Each 2,314.00 ₹ 2,314.00
421 2.12 S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for including loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
2.12.1 6/32 amps, single pole 3 3 EACH 237.00 ₹ 711.00
422 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 3 3 Each 64.00 ₹ 192.00
423 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. 2 2 Each 80.00 ₹ 160.00
424 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.4 9/10 watt LED lamp 2 2 EACH 161.00 ₹ 322.00
425 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 2 2 Each 521.00 ₹ 1,042.00
426 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
427 5.10 Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. 5 5 Each 1275.00 ₹ 6,375.00
428 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 2 2 Set 13,721.00 ₹ 27,442.00
429 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 60 60 Meter 144.00 ₹ 8,640.00
430 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
431 7.4 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
7.4.1 Upto 35 sq. mm (Clamped with 1 mm thick saddle) 60 60 Meter 43.00 ₹ 2,580.00
432 AR Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD). All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis. Conforming to NBC/statutory norms and fulfilling following requirements
(i) Type : Passenger Lift
(ii) Load : As Specified
(iii) (iii) Speed: 1.00 metre/sec.
(iv) (iv) Control: ACV3F, 32bit microprocessor integrated serial communication control system with RMS (remote monitoring system)/BMS (building monitoring system) supporting software.
(v) Motor/machine: Permanent magnetic synchronous gearless motor.
(vi) Operation: Simplex collective selective with/without lift attendant.
(vii) Total rise: About 3 mtrs. (approx) between two stops.
(viii) Landings: All floors on same side.
(ix) Floors served: As Specified
(x) Signal : Digital Car position indicator, car travel direction indicator inside car & at all landings, voice annunciator with suitable music shall be provided in the lift car.
(xi) Shaft size: As per manufacturer's design and as per CPWD specification (Part III LIFTS), Shaft to be constructed separately.
(xii) Guide rail: As per manufacturer's specification. (xiii) Lift & car size: As per manufacturer's design and as per CPWD specification
(xiii) Lift & car size: As per manufacturer's design and as per CPWD specification (Part III LIFTS )
(xiv) Car entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xv) Landing entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xvi) Car door: S.S. (stainless steel) hairline finish centre /telescopic opening door.
(xvii) Landing door: S.S. (stainless steel) hairline finish centre/telescopic opening door with.
(xviii) Door operation: Automatic electric power operated door, full height infrared curtain with multiple criss/cross light beams.
(xix) Car interior: S.S. (stainless steel) panel with hair line finish on all sides.
(xx) Car floor: Anti skid PVC flooring on heavy duty M S (mild steel) platform.
(xxi) Car ceiling & lighting: S. S. (stainless steel) finish with aesthetic appearance with LED ceiling lights
(xxii) Carventilation: Pressure fan/blower fan (car fan with automatic sleep timer shall be provided)
(xxiii) Emergency lighting in car: Battery operated emergency lighting in the lift car.
(xxiv) Intercom system: Battery operated intercom system in lift car, machine room and ground floor/control room
(xxv) Emergencyalarm: Battery operated alarm bell system in lift car & control room ground floor
(xxvi) Position of machine room: Directly above the hoistway.
(xxvii) Electric power supply: AC 415 V, 3 phases 50 Hz & AC 230 V Iphase 50Hz terminated in machine room.
(xxviii) Fire man switch: Fire man switch at machine room/terminal landing
(xxix) All car panel buttons and all floor switches must be with Braille language as per lift act.
(xxx) Audio visual indication in the lift car showing overloading shall be provided such that doors keep open till excess load is removed.
(xxxi) Spring buffer/hydraulic buffer shall be provided
(xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided.
(xxxii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc.
(xxxiv) In the hoist way fascia plate shall be provided.
(xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the department, machine room or at desired level.
(xxxvi) Car top safety barricade shall be provided.
(xxxvii) ARD (automatic rescue device): Solid state inbuilt automatic rescue device (ARD) automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure, capable of moving the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure.
(Make:- OTIS/ KONE/ SCHINDLER/MITSHUBISHI/ THYSSENKRUPP) with 3 years free maintenance during DLP Period.
433 Operation of Lift for 1st year including 3rd party inspection charge. 1 1 Year 194,100.00 ₹ 194,100.00
434 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
435 1.27.1 Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required 40 40 Each 234.00 ₹ 9,360.00
436 1.24.6 Supply and Fixing Modular type 2 Pin Telephone Socket for Speaker Outlet on the existing modular plate & box including making connection, excluding modular plate etc as required 40 40 Each 131.00 ₹ 5,240.00
437 1.16.2 Supplying and Drawing 2 pair 0.5 sq mm. FR PVC insulated copper conductor telephone cable through existing PVC concult including connection etc as required. 1800 1800 P/Mtr. 31.00 ₹ 55,800.00
Computer Networking (LAN)
438 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
439 1.27.1 Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell ) 90 90 Each 234.00 ₹ 21,060.00
440 DSR 39.13 Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
39.13.1 Copper Patch Cords of length 1m (3ft) 90 90 Each 173.00 ₹ 15,570.00
39.13.2 Copper Patch Cords of length 3m (10ft) 90 90 Each 405.00 ₹ 36,450.00
441 DSR 39.23.1 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
442 DSR 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 4 4 Each 5,278.00 ₹ 21,112.00
443 NS Supply, Installation, Testing & Commissioning of Ethernet Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP) 4 4 Each 20,758.00 ₹ 83,032.00
444 NS Supply installation testing & commissioning of Ethernet Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link) 4 4 Each 19,070.00 ₹ 76,280.00
445 1.58 Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
446 NS Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. ) 90 90 Each 545.00 ₹ 49,050.00
( SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM)
447 DSR 17.1 Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required 20 20 KWP 54,280.00 ₹ 1,085,600.00
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase,4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.
c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and otheraccessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Meta OxideVaristors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.
f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required.
AUTOMATIC FIRE ALARM & DETECTION SYSTEM
448 DSR 28.2 Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
DSR 28.2.1.2 Two Loop Panel 1 1 Each 250,420.00 ₹ 250,420.00
DSR 28.2.3 Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 2 2 Each 113,734.00 ₹ 227,468.00
DSR 28.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 90 90 Each 3,004.00 ₹ 270,360.00
DSR 28.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 32 32 Each 306.00 ₹ 9,792.00
DSR 28.2.6 Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. 12 12 Each 2,787.00 ₹ 33,444.00
DSR 28.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required 12 12 Each 3,434.00 ₹ 41,208.00
DSR 28.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required 12 12 Each 3,156.00 ₹ 37,872.00
DSR 28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 12 12 Each 4,063.00 ₹ 48,756.00
Part C Total Total Rs. ₹ 9,548,565.00
Total Electrification work (PartA+PartB+PartC) Total ₹ 33,025,631.00
Total Amount of Civil + Electric ₹ 339,541,452.00
Executive Engineer
Building Division, Siwan
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
NIT • 1.01 MB
paper cutting.pdf
NIT • 0.40 MB
suddhi.pdf
NIT • 0.38 MB
20417_Check list forwarding.pdf
NIT • 1.76 MB
20452_JointVentureGuidelines.pdf
NIT • 2.48 MB
58144_Letter No 3183 Dated 3-6-2020.pdf
NIT • 1.08 MB
54865_Letter no 7291 E-in-C bcd.pdf
NIT • 0.55 MB
55685_Letter no 7292 E-in- C bcd.pdf
NIT • 0.64 MB
5768 10.pdf
NIT • 6.90 MB
7974 UDIN.pdf
NIT • 2.18 MB
9417 10 Below.pdf
NIT • 3.35 MB
Evaluation Sheet Group-1.xls
NIT • 0.04 MB
letter 7461_62.pdf
NIT • 0.17 MB
SBD Document.doc
NIT • 0.68 MB
Engineer in chief letter 9803 for 10% below.pdf
NIT • 0.83 MB
BOQ Construction of 10 Court Building, Aminity Building, Hazat Bhawan, Boundary wall including electrification in Sub Divisional Court Maharajganj District-Siwan (1).xlsx
NIT • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .