Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.5 L
Closing Date
21 Jul 2026, 3:30 pm
Similar tender results from the same govt authority in the past 3 years.
(I) Electrical work in c/w "Construction of 50 bedded running room at Godda." (II) Electrical work in c/w "Proposal for construction of New Crew Lobby building at GODDA"
EL-MLDT-E-TENDER-443
EL-MLDT-E-TENDER-443
Open
6 Months
Godda, Jharkhand
₹0
₹2.5 L
29 Jun 2026
29 Jun 2026
7 Jul 2026
A-Electrical work in c/w "Construction of 50 bedded running room at
B-Electrical work in c/w "Proposal for construction of New Crew Lobby
Item Breakup - A-Electrical work in c/w "Construction of 50 bedded running room at Godda."
Supply, installation, testing & commissioning of Set 500 KVA Outdoor type transformer as per - IS 1180 (Part 1): 2014 or latest Conductor (Winding) material -copper Minimum BEE Star Rating/Energy efficiency level-3 MALDA DIVISION-ELECTRICAL/EASTERN RLY
Provision of Heavy flooring of size 16 feet x 16 Numbers feet x 2 feet with boundary wall for transformer placement ( Size as per site, total volumn of work remain same)
Supply, installation & termination of Heat Numbers Shrinkable 11 Kv outdoor type cable end termination kit suitable for 3 core XLPE HT cable up to 95 sq. mm 11 Kv grade
"Erection of the Rail pole 2no for 'H' pole Set structureof suitable length(Apprx. 9 Mtrs. long) complete with foundation of size 6 ft x 2.5 ft x 2.5 ft depth including transportation of rail pole from different location to proposed site as per IS 1239(Part-1):1990 including supply, fixing, testing and commissionig of follwing items as follows. 1) 11 Kv ,400 A., 50 Hz 3-phase vertically mounted Gang Operated Switch complete with down rod, isolator & other accessory with proper earthing as per site requirements-01 set 2) Supply, fixing, testing and commissioning of lighting arrester ( 9KV- 5KV) ( A set of 3 pcs) with all other accessories suitable for 11 KV HT feeder-1set ( Rail pole to be supplied by Rly.)"
Supply, fixing and commissioning of 11 Kv ,630 Set A., 50 Hz 3-phase vertically mounted Gang Operated Switch complete with down rod, isolator & other accessory with proper earthing as per site requirements
Scraping, Cleaning & painting of Rail/tubular Numbers pole along with cross arm bracket by anti- corrosive red oxide & double coat of alluminium paint & finally black paints up to 1.5 Mtr. above ground level.
Supply, fixing & testing of Guy rod assembly of Set size 5/8 inch X 6' ft. long complete with anchor plate and guy rod of suitable length of size 7/10 SWG stranded GI wire straining insulator etc. including foundation of anchor plate as per IE standard.
Supply & fixing of cross arm bracket made of Set M.S. angle of size 65 mm x 65 mm x 6 mm of length 6.5 ft long with 3 Nos. of 11 Kv pin insulator including supply of all necessary clamps, nuts & bolts etc. & painting.
Supply & fixing of ISI branded M.S. channel of Set size 75 mm x 40 mm x 6 mm of length 3.5 Mtrs. Long including fabrication and binding for Double pole structure & allied accessories as per site requirement.
Supply & fixing of ISI branded M.S. angle of Set size 65 mm x 65 mm x 6 mm of length 3.5 Mtrs. Long including fabrication and binding for Double pole structure & allied accessories as per site requirement.
Supply, fixing, testing and commissioning of 11 Set KV Disc insulator complete with hardware materials.
supply, fixing of 1.1KV LT E - PVC/XLPE/HS.KITS- Set STRAIGHT THROUGH JOINT kit 16-120 sq mm
supply and fixing of 1.1KV LT E - Set PVC/XLPE/HS.KITS-STRAIGHT THROUGH JOINT kit 150-240 sq mm MALDA DIVISION-ELECTRICAL/EASTERN RLY
Construction and laying of 110 mm dia HDPE Metre pipe (PE-80,PN-8) by Micro-tunneling method under the road, footpath, rail track etc. As per required depth to laying and inserting HT XLPE 3 Core X 95 sq.mm./LT cable 120-185 sq mm cable through HDPE pipes. (Including supply of HDPE Pipe)(cable will be supplied by Railway)
Butt welded joint for micro tunnelling work with Numbers laying of 110 mm dia HDPE pipes (one joint for every 6 mtrs length
Laying of LT cable through the HDPE pipe 50- Metre 63 mm Diameter (PE 100, PN-6) as per IS 4984 or Latest for Platform surface cable laying of min 1 feet depth for cable laying including supply of HDPE pipe and LT XLPE 4C x 25 sq mm cable (C2-FR-LSH)
Laying of LT cable through the HDPE pipe 50- Metre 63 mm Diameter (PE-100,PN-6) as per IS 4984 or Latest for underground cable laying of min 1 meter depth including supply of HDPE piper LT XLPE 4C x 25 sq mm cable (C2-FR-LSH) for 25 sq mm cable
Cable trenching, laying through underground Metre as per IS-1255, 1983 or latest.including supply of LT XLPE 4C x 25 sq mm cable (C2-FR-LSH)
Cable laying through pole/wall/floor as per site Metre requirement as per IS-1255, 1983 or latest including supply of LT XLPE 4C x 25 sq mm cable (C2-FR-LSH)
Supply of floor mounted LT distribution Feeder Set pillar 4-way size 36''x30''x20'' made by 50mmx50mmx6mm angle covered with inside & outside anticorrosive painted with MS sheet of 14 SWG(2mm thick) on RCC basement. (300A)
Laying of LT cable through the HDPE pipe 90 Metre mm Diameter (PE 100, PN-6) as per IS 4984 or Latest for underground cable laying of min 1 meter depth including supply of HDPE pipe (Cable will be supplied by Railway) For cable 70-185 sq mm cable
Cable trenching, laying as per IS-1255, 1983 or Metre latest.
Cable laying through pole/wall/floor as per site Metre requirement as per IS-1255, 1983 or latest.
Design, Supply, Lifting, Erection, Installation, Per Unit Testing and Commissioning of Outdoor Units of VRF system with Air-conditioner suitable for operation at ambient temp. upto 56C-(Cap- Split to minimum4 units, each unit having minimum capacity 8HP or as per per requirement mentioned by site in-charge) Unit- "Per Unit" should be read as "per/HP"
Supply, Installation, Testing & Commissioning Set of wall mounted High wall units, 230v / 1ph / 50 Hz, complete with all accessories minimum 1.5 TR capacity
Supply, Installation, Testing & Commissioning Set of wall mounted High wall units,230v / 1ph / 50 Hz, complete with all accessories minimum 2 TR capacity
Supply, Installation, Testing & Commissioning Set of wall mounted High wall units,230v / 1ph / 50 Hz, complete with all accessories minimum 2.3 TR capacity MALDA DIVISION-ELECTRICAL/EASTERN RLY
Supply & erection of Refrigerant (R410a/R- Kg 32)charge to the outdoor unit and connected pipes between outdoor unit and AHU as per site requirement.
Supply refrigerant pipe copper piping work with thickness of (19mm/13 mm thick)closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor & outdoor units & specifications, all piping inside the room shall be properly supported with MS hanger / angle etc. as required size 25.4 mm with 19 mm thick insulation. [RM =Running Meter]
Supply refrigerant pipe copper piping work with thickness of (19mm/13 mm thick)closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor & outdoor units &specifications, all piping inside the room shall be properly supported with MS hanger / angle etc. as required size 19.1 mm with 19 mm thick insulation. [RM =Running Meter]
Supply refrigerant pipe copper piping work with thickness of (19mm/13 mm thick)closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor & outdoor units &specifications, all piping inside the room shall be properly supported with MS hanger / angle etc. as required size 15.9 mm with 13 mm thick insulation. [RM =Running Meter]
Supply refrigerant pipe copper piping work with thickness of (19mm/13 mm thick)closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor & outdoor units &specifications, all piping inside the room shall be properly supported with MS hanger / angle etc. as required size 12.7 mm with 13 mm thick insulation. [RM =Running Meter]
Supply refrigerant pipe copper piping work with thickness of (19mm/13 mm thick)closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor & outdoor units &specifications, all piping inside the room shall be properly supported with MS hanger / angle etc. as required size 9.5 mm with 13 mm thick insulation. [RM =Running Meter]
Supply and erection of Y-Joints/T-Joints/Ref- net Numbers separation refrigeration pipe joints and header shall be in the appropriate orientation to enable correct distribution of refrigerant for IDU as per requirement at site.
Cable tray: Supplying and installing following Metre size of perforated Hot Dipped Galvanised Iron cable tray(Galvanisation thicknessnot less than 50 microns)with perforation not morethan 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I.suspenders including G.I.bolts & nuts, etc. as required. (300 mm width X50 mm depth X thick 1.6 mm). MALDA DIVISION-ELECTRICAL/EASTERN RLY
Cable tray: Supplying and installing following Metre size of perforated Hot Dipped Galvanised Iron cable tray(Galvanisation thicknessnot less than 50 microns)with perforation not morethan 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I.suspenders including G.I.bolts & nuts, etc. as required. (150 mm width X50 mm depth X thick 1.6 mm).
Supply, erection and commisioning of GI sheet Square thickness 18 SWG for covering of top of cable Foot tray including supply of scrow, clamp etc as per site.
Drain Piping: i) Supply and fixing of heavy duty RM rigid 25mm dia PVC piping complete with fittings, supports as per AC unit manufacturer's STD. & specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation as required at site & as relevant IS
Drain Piping: ii) Supply and fixing of heavy duty RM rigid 32mm dia PVC piping complete with fittings, supports as per AC unit manufacturer's STD. & specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation as required at site & as relevant IS.
Supply, laying , wiring and commissioning of 2 RM Core 1.5 sq mm PVC insulated Shielded Screened and multi-stranded Copper Cable suitable size of PVC conduit pipe with 1sq. mm for control cum transmission along with looping between indoor & outdoor VRF system as per direction by site engineering-charge.
"MS FRAME FOR OUTDOOR UNITS Supply, Kg Fabrication and Installation of MS frame using channels/angle iron sections as required for mounting of air cooled remote condensers and air cooled condensing units for VRF outdoor units. "
Supply, Installation, testing & commissioning of Set copper/ aluminium base PCB of multi-layer construction, and house microcontrollers, relays, sensors for compressor/fan control, managing power (IPM for inverter), and communicating across the system of Indoor and outdoor for Hitachi make VRF unit.(Above 20 HP)
Supply, Installation, testing & commissioning of Set copper/ aluminium base PCB of multi-layer construction, and house microcontrollers, relays, sensors for compressor/fan control,managing power (IPM for inverter), and communicating across the system of Indoor and outdoor for Hitachi make VRF unit.(up to 20HP)
SITC of liquid line solinoide valve along with all Set accessories in the connection with refrigerant line for Outdoor isolation
SITC of manually operated on-line valve in Set refrigerant line along with all accessories
Supply, fixing and connection of Timer unit for Set AC outdoor unit Consisting of below materials with CRCA enclosure & complete wiring- 1) MCB 63A 4P -02 set 2) Contactor 63A 4P -2NO 3) Digital Time Switch-01 set 4)2Way Center Off Change over Switch 25A-01set MALDA DIVISION-ELECTRICAL/EASTERN RLY
Supply, installation, testing and commissioning Set of TAA Panel, floor mounted as per IEC 61439-1 & 2 or latest, as per following specification 1)Copper Busbar rating 300Amps - 4 Nos (RYB- N)-1 set 2)250, 4P, 50KA Microprocessor type MCCB (Ics=100%Icu) with LSIG protection- 02 nos.( Incoming) b)250A, 4P, On load Changeover -01 no a) 100A, 4P, 50KA Microprocessor type type MCCB (Ics=100%Icu) with LSIG protection 02 nos (Out going) b) 63A, 4P, 50KA Microprocessor type type MCCB (Ics=100%Icu) with LSIG protection 02 nos ( Out going) c) 25A, 4P, 10KA C type MCB - 2 nos (out going) d) 32A 2P MCB 10KA C type 3 nos ( Out going) e) Digital Timer with 63A, AC3 duty power contactor-2 set f) LT3 lines LCD Display, panel mounted multi-function Energy meter (for V, I, Frequency, Power Factor, Power & energy RS485 compatible) -1 set g) LED Indication Lamp (RYB), ON/Off Indication, Push Button in each feeder - 1set h) Earthing Terminal-02 set. (spreader terminals to be provided in each MCCB)
Wiring of sub-main line 2.5 sq mm Phase & Metre neutral (2 Nos copper wire) with ECC of 1no. 1.5 sq.mm , PVC insulated single core, M/Strand copper wire as per General specification of IE rule
Wiring of sub-main line 4 sq mm Phase & Metre neutral (2 Nos copper wire) with ECC of 1no. 2.5 sq.mm. , PVC insulated single core, M/Strand copper wire as per General specification of IE rule
Wiring of sub-main line 6 sq mm Phase & Metre neutral (2 nos copper wire) with ECC of 1no. 2.9 sq.mm (minimum) , PVC insulated single core, M/Strand copper wire as per General specification of IE rule
Wiring of Main line 3 Phase & neutral (4 wire) Metre copper conductor of size 10 mm sq with ECC as per General specification of IE rule
Extra cost for concealed of Main/sub main Metre line1.5/4/ 6 sq mm
Wiring of light /fan/exhaust/wall fan point Numbers 360.00 (modular)
Wiring of 2 way light /fan point
Extra cost for concealed /fan/exhaust/wall fan point
Supply , fixing and connection of 6A plug Numbers socket-01 nos Switch -6A -01 nos with board and wire connection.(modular)
Supply , fixing and connection of 6/16A plug Numbers socket-01 nos Switch -20A -01 nos with board with wire connection.(modular)
Extra cost for concealed of 6A/6-16A plug point Numbers
supply and fixing of Door Bell- Battery Set Operated Wired Door Bell including supply of battery
Supply , fixing & connection of LED 9W lamp Set with suitable angular batten holder with metal ring .
Supply & fixing of LED tube light fitting Numbers 160.00 complete set 20W (Aluminum housing)Lumen 120Lm/watt MALDA DIVISION-ELECTRICAL/EASTERN RLY
Supply, replacement/new provision and fixing Numbers of BLDC energy efficient (5 star rated) ceiling fan 1200 mm sweep wattage-max 35W with air delivery:-min 230 cu mtr/min (with remote)
Supply, fixing and connection of Exhaust Fan of Numbers 300 mm.
"Supply and fixing of wall light fittings for Numbers reading LED of 3W
Supply , concealed fixing & connection of of Numbers LED Skirting light (Foot light) 3 module (including concealed through GI Box 3M)
"Supply, fixing and connection of 8W Numbers Landscape Luminaire -Bollard with PCC foundation ( L-1 ft x B-1 ft x H-10 inch) "
Supply, fixing and connection of Cable Junction Numbers Boxes IP 66 with terminals and integrated membranes / metric knockouts for cable entry size (L X B X H) mm -104 x 104 x 70 as per hensel cat no-DK 0404 G or similar including supply of all materials.
Laying of LT cable/wire through the HDPE pipe Metre 40 mm Diameter (PE 63, PN-6) as per IS 4984 or Latest for underground cable laying of min 1 feet depth including supply of HDPE pipe and cable/wire 3 core 4 sq mm copper cable including all necessary connection with copper lug.
Supply and fixing of G.I. Pipe heavy gauge size Set 1/1.25 inch dia 2.5 ft. long bended as per site requirement including 2 sets of M.S clamps, nuts & bolts, wiring with flexible PVC Cu. cable through G.I. Pipe.
Supply and fixing and connection of LED Street Set light 70W. System efficasy min-140Lm/w
Design, manufacture, display ofwall /hanging / Square floor mounting typeLED illuminated sign / Foot directionboard as per specification.
Erection and installation of wall /hanging / floor Square mounting type LEDilluminated sign / direction Foot boardsincluding wiring and all.
Supply, fixing and connection of 12W LED Numbers recess mounting( downlight).(3000-5600K)
Supply design, fixing and connection of LED Square Name board Foot
Supply and fixing and testing of occupancy Set sensor for lighting circuit of chambers etc.
Supply, fixing, connection of Busbar Chember 4 Set way of Cap-63A wall mounted including connection of LT cable with proper lugs and and cable gland etc
Supply, fixing & connection three phase Set distribution board provision for incomer 8 pole and single phase outgoings 4 way (8+12) modules including followings items 1) FP MCB (63A)-01 nos 2) DP MCB (16A)-6 nos with necessary connection including earth."
"Supply, Fixing & connection of SPN 6 way (No Numbers of module 6+2) MCB sheet steel Distribution Board with metal door i) Inclding supply of 4 nos SP MCB (6-32A) ii) 01 no RCCB 32/40A (100mA)" MALDA DIVISION-ELECTRICAL/EASTERN RLY
Supply, fixing and connection of modular Set mobile charging board consisting of following... 1) Modular board Cover with base plate-8M -01 n o s 2) Modular Switch 1way 10A-03 nos 3)6/10A multi socket -02 nos 4) Twin USB Charger Upto 2.1 A -1M- 01 nos 5) 8 Module GL metal board-01 nos
Extra cost for concealed DB/mobile charging Numbers board
Supply, installation , commissioning & testing Set of earthing as per IS:3043 or latest amendment.
Supply and laying of GI strip 25 mm X 6 mm or Kg 50 mm X 6 mm for laying from earth pipe to transformer/body/panel board/ switch board earth nutral connection with LT & HT body etc
Supply, Installation, test and commissioning of Set Water Heater Cap-25 Ltrs
Installation & commissioning of Water Cooler Numbers on suitable cc foundation including supply of all material and water drainage system with fixing of all materials at site location.(water cooler will be supplied by Rly)
Supply & fixing of Perforated Cable Tray box Metre type with cover Size 300 mm x 75 mm- Hot dip Galvanized.
Supply and fixing, Installtion testing and Set commissioning of Solar water Heating System with Heat Exchanger cap 500 LPD.
Supply and fixing of of 1 " CPVC pipe
Supply and fixing and fixing of 1 " UPVC pipe
Supply & fixing of 0.75 inch CPVC Brash FTA.
Supply & fixing of 0.75 inch to 0.5 inch CPVC Numbers Brash L bow.
Supply & fixing of 1 nch CPVC Ball Valve.
Supply & fixing of 1inch CPVC Bush.
Supply & fixing of 1 inch x 3/4 inch CPVC to Numbers UPVC Bush.
Supply & fixing of 1inch UPVC L Bow.
Supply & fixing of 1 inch UPVC ( T ).
Supply & fixing of 1 inch UPVC socket.
Supply and fixing of 3/4 " CPVC pipe
Supply and fixing of 1" CPVC union
Supply and fixing of 1" CPVC (T)
Supply and fixing of 1" CPVC socket
Supply and fixing of 1" CPVC L Bow
Supply and fixing of 3/4" CPVC (T)
Supply and fixing of 3/4" CPVC SOCKET
Supply and fixing of 3/4" CPVC L Bow
Supply and fixing of 1/2" STEEL TAP
Sypply of 1" Brash ball valve
Supply and fixing of UPVC Ball Valve
Supply and fixing of 1" UPVC FTA (Brash)
Supply and fixing of 1" UPVC MTA (Brash)
Supply and fixing of 1" CPVC Brash FTA
Supply and fixing of 1" CPVC Brash MTA
Supply and fixing of 1" UPVC UNION
Supply and fixing of 3.4/1/2 CPVC BRASH Numbers SOCKET
Supply and fixing of CPVC GUM 100 grm
Supply and fixing of UPVC GUM 100 gm MALDA DIVISION-ELECTRICAL/EASTERN RLY
Supply and fixing of TAFLON Tape
Supply and fixing of Zink Pest
Supply and fixing of CPVC China Hook 3/4"
Supply and fixing of CPVC China Hook 1/4"
Supply and fixing of CPVC China Hook 1.1/4"
Supply of Tank Nipple set
Supply and fixing of White cement
Supply and fixing of 1" G.I Socket
Supply and fixing of 1" G.I Plug
Supply and fixing of 1/2" , 2" G.I Nipple
Supply and fixing of Steel Cap
Providing and placing on terrace (at all floor Litre levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Civil work including installation of water tank
Supply & fixing of GI Net for covering of solar Square heater Foot
Supply & fixing of 1.1/2x1/2 GI Nut bolt etc.
Supply fixing & connection of GI angle of sizes Kg 1.5 inch x 1.5 inch x 5mm,1.25inch x1.25inch x5mm & GI flat of size 1.0inch x5mm, 1.5 inch x 5mm . including welding, RCC for channel fixing (with RCC of size 8inch x 8inch x12inch for each corner limp, 4 nos. ) and AL painting at welded point with fixing for covering of solar water heater as protection from monkey
Supply, fixing and connection of 32A Double Set Pole RCCB 100mA with enclosure. Total 9340884.46
Item Breakup - B-Electrical work in c/w "Proposal for construction of New Crew Lobby building at GODDA"
Laying of LT cable through the HDPE pipe 50- Metre 63 mm Diameter (PE-100,PN-6) as per IS 4984 or Latest for underground cable laying of min 1 meter depth including supply of HDPE piper LT XLPE 4C x 25 sq mm cable (C2-FR-LSH) for 25 sq mm cable
Cable trenching, laying through underground Metre as per IS-1255, 1983 or latest.including supply of LT XLPE 4C x 25 sq mm cable (C2-FR-LSH)
Cable laying through pole/wall/floor as per site Metre requirement as per IS-1255, 1983 or latest including supply of LT XLPE 4C x 25 sq mm cable (C2-FR-LSH)
Supply of floor mounted LT distribution Feeder Set pillar 4-way size 36''x30''x20'' made by 50mmx50mmx6mm angle covered with inside & outside anticorrosive painted with MS sheet of 14 SWG(2mm thick) on RCC basement. (300A)
Laying of minimum 75 mm dia HDPEpipe (PE- Metre 100, PN-6) or as per site byMicro - tunneling method under theroad, footpath, rail track etc. As perrequired depth to laying and inserting LT4 core cable 70 sq mm cable throughHDPE pipes including supply of HDPEpipe.(cable will be supplied by Railway). MALDA DIVISION-ELECTRICAL/EASTERN RLY
Butt welded joint for micro tunneling work with Numbers laying of 75 mm dia HDPE pipes (one joint for every 6 mtrs length)
Laying of LT cable through the HDPE pipe 90 Metre mm Diameter PE 100, PN-6) as per IS 4984 or Latest for underground cable laying of min 1 meter depth including supply of HDPE pipe (Cable will be supplied by Railway) For cable 70-120 sq mm cable
Cable trenching, laying as per IS-1255, 1983 or Metre latest.
Cable laying through pole/wall/floor as per site Metre requirement as per IS-1255, 1983 or latest.
supply and fixing of 1.1KV LT E - Set PVC/XLPE/HS.KITS-STRAIGHT THROUGH JOINT kit 16-95 sq mm
Supply and fixing of 1.1KV LT E - Set PVC/XLPE/HS.KITS-STRAIGHT THROUGH JOINT kit 120-300 sq mm
Supply, replacement, fixing , testing & Set commissioning of 1.5 ton Split AC 5 Star indoor and outdoor unit (ISEER value from >=5.6 to 6.0) Inverter AC (copper pipe)
Supply Split/window Air conditioner up to 1.5 ton Complete with 4 Module Plate, 20A Starter, 25A Plug & Socket-25A
Supply , fixing and connection of Copper Foot Running Pipe line (Suction-5/8" Dia, discharge- 3/8" Dia) or as per site ,Including insulation, power supply wire etc
"Supply, fixing and connection of AC Control Set DB Consisting of Below materials with Complete wiring 1) 12 way SPN double door DB-01 set 2) RCBO 32A 2P (100mA)-01 set 3) Contactor 25A ,2NO ,1M-02 set 4) Digital Time Switch-01 set 5) 2Way Center Off Change over Switch 25A-01set"
"Supply, commissioning of LT Panel , wall mounted as per following specification 1)Copper Busbar rating 200Amps - 4 Nos (RYB-N)-1set 2) 160A, 4P, 50KA Microprocessor type type MCCB (Ics=100%Icu) with LSIG protection 02 nos with spare (Incoming) a) 63A, 4P, 50KA Microprocessor type type MCCB (Ics=100%Icu) with LSIG protection 02 nos (Out going ) b) 32A, 4P, 50KA Microprocessor type type MCCB (Ics=100%Icu) with LSIG protection 02 nos (Out going) C) Digital Timerfor with 32A, AC3 duty power contactor- 1 set b) LCD Display, panel mounted multi-function Energy meter (for V, I, Frequency, Power Factor, Power & energy RS485 compatible)- 1 set f) LED Indication Lamp (RYB), ON/Off Indication, Push Button in each feeder -1 set g) Earthing Terminal-02 set (spreader terminals to be provided in each MCCB) "
Wiring of sub-main line 2.5 sq mm Phase & Metre neutral (2 Nos copper wire) with ECC of 1no. 1.5 sq.mm , PVC insulated single core, M/Strand copper wire as per General specification of IE rule
Wiring of sub-main line 4 sq mm Phase & Metre neutral (2 Nos copper wire) with ECC of 1no. 2.5 sq.mm. , PVC insulated single core, M/Strand copper wire as per General specification of IE rule MALDA DIVISION-ELECTRICAL/EASTERN RLY
Wiring of sub-main line 6 sq mm Phase & Metre neutral (2 nos copper wire) with ECC of 1no. 2.9 sq.mm (minimum) , PVC insulated single core, M/Strand copper wire as per General specification of IE rule
Wiring of Main line 3 Phase & neutral (4 wire) Metre copper conductor of size 10 mm sq with ECC as per General specification of IE rule
Extra cost for concealed of Main/sub main Metre line1.5/4/ 6 sq mm
Wiring of light /fan/exhaust/wall fan point Numbers 230.00 (modular)
Extra cost for concealed /fan/exhaust/wall fan point
Supply , fixing and connection of 6A plug Numbers socket-01 nos Switch -6A -01 nos with board and wire connection.(modular)
Supply , fixing and connection of 6/16A plug Numbers socket-01 nos Switch -20A -01 nos with board with wire connection.(modular)
Extra cost for concealed of 6A/6-16A plug point Numbers
supply and fixing of Door Bell- Battery Set Operated Wired Door Bell including supply of battery
Supply , fixing & connection of LED 9W lamp Set with suitable angular batten holder with metal ring .
Supply & fixing of LED tube light fitting Numbers 160.00 complete set 20W (Aluminum housing)Lumen 120Lm/watt
Supply, replacement/new provision and fixing Numbers of BLDC energy efficient (5 star rated) ceiling fan 1200 mm sweep wattage-max 35W with air delivery:-min 230 cu mtr/min (with remote)
Supply, fixing and connection of Exhaust Fan of Numbers 300 mm.
"Supply and fixing of wall light fittings for Numbers reading LED of 3W
Supply , concealed fixing & connection of of Numbers LED Skirting light (Foot light) 3 module (including concealed through GI Box 3M)
"Supply, fixing and connection of 8W Numbers Landscape Luminaire -Bollard with PCC foundation ( L-1 ft x B-1 ft x H-10 inch) "
Supply, fixing and connection of Cable Junction Numbers Boxes IP 66 with terminals and integrated membranes / metric knockouts for cable entry size (L X B X H) mm -104 x 104 x 70 as per hensel cat no-DK 0404 G or similar including supply of all materials.
Laying of LT cable/wire through the HDPE pipe Metre 40 mm Diameter (PE 63, PN-6) as per IS 4984 or Latest for underground cable laying of min 1 feet depth including supply of HDPE pipe and cable/wire 3 core 4 sq mm copper cable including all necessary connection with copper lug.
Supply and fixing of G.I. Pipe heavy gauge size Set 1/1.25 inch dia 2.5 ft. long bended as per site requirement including 2 sets of M.S clamps, nuts & bolts, wiring with flexible PVC Cu. cable through G.I. Pipe.
Supply and fixing and connection of LED Street Set light 70W. System efficacy min-140Lm/w. MALDA DIVISION-ELECTRICAL/EASTERN RLY
Design, manufacture, display ofwall /hanging / Square floor mounting typeLED illuminated sign / Foot directionboard as per specification.
Erection and installation of wall /hanging / floor Square mounting type LEDilluminated sign / direction Foot boardsincluding wiring and all.
Supply design, fixing and connection of LED Square Name board Foot
Supply, fixing and connection of 12W LED Numbers recess mounting( downlight).(3000-5600K)
Supply and fixing and testing of occupancy Set sensor for lighting circuit of chambers etc.
Supply, fixing, connection of Busbar Chember 4 Set way of Cap-63A wall mounted including connection of LT cable with proper lugs and and cable gland etc
Supply, fixing & connection three phase Set distribution board provision for incomer 8 pole and single phase outgoings 4 way (8+12) modules including followings items 1) FP MCB (63A)-01 nos 2) DP MCB (16A)-6 nos with necessary connection including earth."
"Supply, Fixing & connection of SPN 6 way (No Set of module 6+2) MCB sheet steel Distribution Board with metal door i) Inclding supply of 4 nos SP MCB (6-32A) ii) 01 no RCCB 32/40A (100mA)"
Supply, fixing and connection of modular Set mobile charging board consisting of following... 1) Modular board Cover with base plate-8M -01 n o s 2) Modular Switch 1way 10A-03 nos 3)6/10A multi socket -02 nos 4) Twin USB Charger Upto 2.1 A -1M- 01 nos 5) 8 Module GL metal board-01 nos
Extra cost for concealed DB/mobile charging Numbers board
Supply, installation , commissioning & testing Set of earthing as per IS:3043 or latest amendment.
Supply and laying of GI strip 25 mm X 6 mm or Kg 50 mm X 6 mm for laying from earth pipe to transformer/body/panel board/ switch board earth nutral connection with LT & HT body etc
Supply, Installation, test and commissioning of Set Water Heater Cap-25 Ltrs
Installation & commissioning of Water Cooler Numbers on suitable cc foundation including supply of all material and water drainage system with fixing of all materials at site location.(water cooler will be supplied by Rly)
Supply & fixing of Perforated Cable Tray box Metre type with cover Size 300 mm x 75 mm- Hot dip Galvanized. Total 2906131.72
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Technicalcompliances.pdf
ATTACHMENT
CommercialCompliances.pdf
ATTACHMENT
Othercompliances.pdf
ATTACHMENT
Transformerspecification.pdf
ATTACHMENT
BISLevelamendment.pdf
ATTACHMENT
443SpecificationofWorksAnnexureA.pdf
ATTACHMENT
443OtherTenderConditionsAnnexure-F.pdf Other conditions Annexure F
ATTACHMENT
Deployment of Qualified Engineer
ATTACHMENT
GCC-2022uptoACS11.pdf
ATTACHMENT
BGFormatforBidSecurity.pdf
ATTACHMENT
TenderDocuments-2022MLDT.pdf
ATTACHMENT
Mandatorydocumentslist.pdf
ATTACHMENT
LetterofcreditformatAnnexure-B.pdf
ATTACHMENT
MandatoryupdationLabourdataAnnexC.pdf Labour Data Annexure C
ATTACHMENT
MandatoryupdationLabourdataAnnexC.pdf
ATTACHMENT
Deploymentofqualifiedengineer-Annexure-_E_.pdf
ATTACHMENT
443OtherTenderConditionsAnnexure-F.pdf
ATTACHMENT
Download all tender documents and submit your bid