| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | ₹20.0 L Quoted ₹20.9 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹27.5 L+₹6.6 L (31.6%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | ₹27.5 L+₹6.6 L (31.6%) | L2 | Rejected-Finance Other than lowest tender |
| 3 | L3₹28.5 L+₹7.6 L (36.5%)Rejected-Finance | ₹28.5 L+₹7.6 L (36.5%) | L3 | Rejected-Finance Other than lowest tender |
| 4 | L4₹28.9 L+₹8.0 L (38.3%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹28.9 L+₹8.0 L (38.3%) | L4 | Rejected-Finance Other than lowest tender |
| 5 | L5₹30.9 L+₹10.0 L (47.9%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹30.9 L+₹10.0 L (47.9%) | L5 | Rejected-Finance Other than lowest tender |
Tender Value
Refer Docs
EMD Value
₹74,420
Closing Date
19 Oct 2020, 6:00 pmClosed
GE (N) DELHI CANTT -10
GE (N) DELHI CANTT -10
REPAIR MAINT OF EXTERNAL ELECTRIC SUPPLY SERVICES SYSTEM LT PANELS SWITCHGEARS UG CABLES STREET SECURITY LIGHTS AND CONNECTED E M WORKS AT DGQA AREA AT ANAND PARBAT UNDER GE NORTH DELHI CANTT 10
2020_MES_378127_1
GE/NORTH-53/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (N) DELHI CANTT -10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT -10
₹74,420
Yes
19 Jan 2021
18 Sept 2020
20 Oct 2020
18 Sept 2020
19 Oct 2020
3 Oct 2020
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5m depth for laying under ground cable/pipes in loose/soft soil all as specified and directed.
All as per above item but Hard/dense soil.
All as per above item but Soft/disintegrated rock.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for sand cushioning for protection of cables with screen wash river sand and punning to proper required cover complete
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx l80mm x 40mm , as specified and directed
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked,size of 300 sqmm 3 core suitable for HT 11 KV(E) system, laid in trenches,fixed to pole/wall incl taking down unsv complete all as specified nd directed. (Note :- Earth work,cable protection,sand fillings,cable joint shall be measured and paid separately)
All as per above item but size 185 sqmm 3 core
All as per above item but size 120 sqmm 3 core
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors 10 sqmm 2 core laid in trenches, fixed to pole/wall incl taking down unsv complete any size,type&core complete all as specified and directed. Note:- Earth work,cable protection,sand fillings,cable joint shall be measured and paid separately.
All as per above item but 16 Sqmm 4 Core.
All as per above item but 25 Sqmm 3.5/4 Core.
All as per above item but 35 Sqmm 3.5 Core.
All as per above item but 50 Sqmm 3.5 Core.
All as per above item but 70 Sqmm 3.5 Core.
All as per above item but 95 Sqmm 3.5 Core.
All as per above item but 150 Sqmm 3.5 Core.
All as per above item but 185 Sqmm 3.5 Core.
All as per above item but 100 Sqmm single Core.
Laying only (Re routing) serviceable any type of cable up to 70 sqmm 2/3/ 3 ½ /4 core size all as specified and directed. (Note:- Excavation, sand, bricks and connected items shell be measured and paid separately).
All as per above item but 95 sqmm to 240 sqmm.
Laying only old bricks over the sand cushioning dry and flat for cable protection. (Note:- Bricks obtained from the removing of UNSV cable and re routing cable)
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) Excavation,earth work,cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (d) Material and labour for emergency maintenance work of HT/LT cable line during breakdown by deploying skilled labour and electricians at faulty site having gang of minimum 4 persons including transportation and other tools and plant required at site for fault rectification.(e) Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. In case the contractor or his rep shall not come to the site of breakdown and start attending breakdown within two hours, a penalty of Rs 600 per fault per hour shall be imposed over contractor and shall be deduct from his dues.
All as per above item but 1100 Volt LT cables
Taking out faulty underground 1100 Volt LT cable of any size by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks/PCC cable cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per above item but 11000 Volt HT cables
S&F, testing and commissioning of air break switch gang operated tripple pole mechanically operated mechanism, switch air break gang operated mounted on 15 Nos insulators and steel frame with operating rod of 25 mm bore GI Pipe and locking arrangements, flat iron clamp 50mm x 6mm incl MS channels of suitable size and length for fixing of gang operatimg device incl bolts,nuts and eashers incl jumper connection with copper flexible strip designed jumper incl taking down unsv complete all as specified and directed. (Make- BHEL,Oblum, ABB)
S&F, testing and commissioning of HT lightening arrester metal oxide type (gap less) for out door use complete with all fittings and fixing arrangements, transmission class discharge capacity 65 kilo amps suitable for 11000 volts including brackets, clamps, nuts, bolts, washers and connecting to earth wire 4mm dia GI with manufacturers test certificate, incl taking down unsv complete all as specified & directed. (Make- BHEL, Crompton Greaves, Scheinder, Oblum )
Material and labour for disconnecting faulty/burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals with suitable size of thimbles and cable glands for Panel Boards for 25 Sqmm 3.5/4 core to 70 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade incl taking down unsv complete all as directed for the following sizes :- Make - Raychem/M-Seal/Denson
16-50 Sqmm x 3.5 core/ 4 core
70-150 Sqmm x 3.5 core
185 -240 Sqmm x 3.5 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 to 300 sqmm XLPE armoured aluminium conductor cable incl taking down unsv complete all as specified and directed (Make - Raychem/M-Seal/Denson)
All as per above item but out door termination complete.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 to 300 sqmm XLPE armoured aluminium conductor cable incl taking down unsv complete all as specified and directed.Make - Raychem/M-Seal/Denson
M&L for painting of transformer of capacity 200 to 500 KVA with synthetic enamel paint (Two coats) of existing colour, with spraying machine, after cleaning, scrabing, preparation of outer surface of transformer including writing of SM No, MES and capacity of transformer complete all as specified and directed.
S&F in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers, capacity upto 200 to 500 KVA complete all as specified and directed.
S&F in repairs for temperature gauge for transformers 0-100 degree celsius complete all as specified and directed.
M&L for ON load centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration achieve dielectric strength 50-60 KV complete all as specified and directed. (Note :- 1. Deficient quantity of Transformer oil required for top up shall be measured and paid separately under relevant items of this Schedule. 2. Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arranged by the contractor)
Supply & filling new transformer oil of having dielectric strenght 60 KV to top up level complete all as specified and directed (Make- Powerlink/Powerzone/HP/apolo/indotech)
S&F in repair LT Porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 500 KVA complete
S&F in repair HT 11 KV porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 500 KVA complete
M & L for Hardcore of gauge n exc. 40 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M & L in repairs for duct cover Mild steel plates, chequered, 5mm thick in Fe 410-W (Gde E-250) quality-A with welding including lifting arengment of duct cover complet all as specified and directed.
Shifing and relocating of transformer in AOR upto 300 KVA capacity pole/plinth mounted indoor/outdoor type incl removing and refixing necessary cable connections complete all as specified and directed. Note: (i) Necesary T&P complete shall be arranged by the contractor. (ii) During shiting process damage any exist infrastructure the same is make good by his own cost.
S&F in repairs for 4 mm dia MS wire 75x75mm mesh, made upto into mattress or cages approx 2.0 mtr height and fixed with flate iron/angle by welding in position and directed complete all as specified and directed. Note:- MS angle, MS flats, Nuts, Bolts and washer will be measured and paid separatly under relevant items.
M & L for two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified.
M&L in repiairs for MS work of angle iron channels and iron flats for post and struts of fencing around transformer plinth etc drilling holes, flat iron for securing wire mesh by welding to angle iron frame and framed work as in door/ gate of angle and wire mesh door to be fixed by 02 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement complete all as specified and directed.
M&L in repairs for Brick work with sub-class 'B' bricks, straight or curved on plane exc 6 m mean radius, built in cement mortar 1:4 complete as specified and directed
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement complete all as specified and directed
Material and labour in repairs for cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) for sub floors, sub-bases, floors, foundation and paving etc complete
Servicing of ACBs by taking out Air circuit breaks of capacity 400-1250 amps from LT panels cleaning all parts internally and externally checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contract, floating contacts, servicing of motor, and charging system and re-fixing it on its original position and testing including testing of control wiring of the respective ACBs by the authorised service engineer and shall submit necessary certificate for the same all as specified.
S&F in repairs of shutter assembly suitable for 3 pole ACB upto 800 amps capacity complete with all accessories
S & F in repairs of arc chute (set of 3) suitble for 3 pole ACB up to 800 Amps capacity complete with all accessories
S & F in repairs of floating isolating contacts (set of 3) suitable for 3 pole ACB upto 800 Amps capacity complete with all accessories all as specified.
Material and labour for servicing /testing of breaker/control panel of VCBs/RMUs including CT, PT and relays in control panel of of capacity 630 Amps and rating 11 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Replace the jaw contacts,If required .(xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish .(xv) Replacement of Dashpot/shock absorbers .(xvi) Replacement of carbon brush of spring charging motor (b) The following test shall be carried out:- (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay : - (i) Over current and earth fault relay (d) Testing of followig Aux relay:- (i) DC Supply supervision relay. (ii) Master trip relay Note:- Spares shall be measured and paid separately as catered in under respective items
Isolate contact assembly
Auxilary switch
Earth contact assembly
Closing push button
Tripping push button
Spring charged indicator
ON/OFF indicator
Plug & socket assembly
Phase barrier (Set of 02 Nos with nuts & bolts)
Flexible copper connector
Support insulator suitable for ABB Vmax model VCB
Manual spring charging handle
Tripping coil assembly
Closing coil assembly
Limit switch
Shutter assembly
Opening lever for circuit breaker racking in/out
Vacuum interrupter suitable for 630 amps 11 KV HT VCB, Make- ABB
S&F in repairs of heater suitable for 11 KV HT panel all as specified. Make: As per sample
S&F in repairs of thermostat suitable for 11 KV HT panel all as specified. Make: As per sample
S & F in repairs of LED Lamp as per colour scheme suitable for 110 volt DC supply for mounting on HT Panel all as specified. Make: As per sample
S & F in repairs of digital electronic three phase earth fault and over current relay panel mounting type, 3 phase,110 V ( L-L ), MC61A model of L&T, including necessary connection/modification with suitable and including copper cable and other connected accessories for mounting on existing HT panel, Cat pt No.MC61ANX2200 of L&T /C&S or Equivalent.
S & F in repairs of power pack unit suitable for 220 volts AC input & 110 volts DC output complete with 12 volts, 7 Ah sealed lead acid batteries and suitable ammeter, voltmeter, switches etc suitable for operation of HT Panel all as specified and directed. Make: MMAXPOWER & Power Pack or equivalent.
S & F in repairs of 2X12V DC battery with Battery charger with suitable burden for motor operation with input voltage of 230 V AC and out put voltage of 24 V DC (make of Battery- Exide/HBL)
S&F in repair of digital Trivector meter for 11 KV HT Panel mounting type incl necessary connection/modification with copper cable and other connected accessories for mounting on existing HT panel (Make Conzerve EM 6400 or equivallant)
S & F in repairs of TNC switch suitable for operation of VCB 630 amp of ABB V max model make installed in HT panel 11 KV all as specified. Make - as per sample
S & F in repairs of 11KV fuse tubular type, 11KV/1A suitable for operation of HT Panel all as specified and directed. Make: as per sample
S & F in repairs of spout insulator/cable boots suitable for 630 amps HT VCB of ABB V max model make installed in 11 KV HT panel all as specified.
S & F in repairs of motor gear assembly, suitable for ABB V max complete with necessary wiring and accessories all as specified and directed.
Disconnection of all electric connection & taking out old/defective Current Transformer (CT) from 11 KV VCB panel and Supply, fixing, installation & testing of Current transformer, indoor, epoxy cast, 11000 Volts, 50 Hz, ratio 200-100/5A suitable for operation of HT Panel all as specified and directed. Make: STI or equivallent
All as per above item but 60-30/5A amps complete.
Checking the existing pressure of SF6 Gas in Gas Chamber of 11 KV , upto 630 Amps RMU before filling and rectifying any leackage and topping up the SF6 gas in the chamber of RMU including supervision of gas filling/topping up process and checking the pressure of gas after filling complete all as directed at site.(Note: SF6 gas will be measured and paid separately.)
Supply and filling SF6 gas cylinder complete all as directed.
Labour for cutting and removing grass, vegetation bushes etc from surrounding HT installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed.
Labour for trimming of tree branches around the street/security light poles (not less than 2 mtrs) to clear the vegetation including cleaning of nest of birds, creepers on poles and stays etc complete removing and disposed off from the site complete
Supply and laying in replacement of synthatic insulating mat of size 2m x 1m x 12 mm complete
All as per above item but size 2m x 1m x 25 mm.
M & L in repair for PCC root indicator made of PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate suitable for mounting on root of HT cable of width 45cm, depth 10cm & height 100cm overall embedded to the depth not less than 45cm below ground level complete
M & L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint as per colour scheme complete
Removal of UNSV danger notice plate and M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size Complete all as specified and directed. .
All as per above but HT, 25x20cm.
Removal of UNSV PCC/Steel pole and M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts, nuts & screw all as specified and directed Type 410 SP 31 (9 Mtr long) with two coat of aluminium paint over a coat of red oxide primer in full length of the pole with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation incl dismantling the unserviceable pole with fittings etc complete.(Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items).Complete all as specified and directed.
Demolition of cement concrete of any description and in any position complete
M&L for PCC (1:4:8) type D2,( using 40 mm graded aggregate) as in foundations, filling and mass concrete complete
M&L for PCC (1:3:6) type C1, (Using 20 mm graded aggregate) as in foundations, for coping, filling and mass concrete with cement plastering finishing complete
M&L for painting of LT electric pole, steel tubular swaged pole (9 mtr long) of any size, any pattern with one coat of aluminium paint over a coat of red oxide primer in full length of the pole and marking the pole with black and yellow strip (upto to 1.50 mtr length, 1.50 mtr height of PCC coping) alternatively including numbering the pole serially all as directed
M&L for painting of LT RCC electric pole, (11 mtr long) of any size pattern with one coat of weather proof acrylic synthetic paint and marking the pole with black and yellow strip (upto to 1.50 mtr length from ground) alternatively including numbering the pole serially all as directed .
M&L for two coats of synthetic enamel paint on plastered surfaces as specified colours complete
M&L for high intensity retro reflective sheet 5cm width length up to 60 cm length as specified colours with heavy duty self adhesive tape for stick on electrical pole complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique with out disturbing top surface of the road and necessary machine including HDPE pipe of 100 mm dia suitable for 0.6 mpa working pressure complete all as specified and directed (Note : Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost)
M & L for Cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate complete
M & L for steel tubes, light grade galvanised 100 mm bore laid in trenches/walls and spreading for cable cushioning/protection all as specified and directed.
All as per above item but 80 mm bore.
All as per above item but 50 mm bore.
All as per above item but 32 mm bore.
M&L for repairs of cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer complete
M&L for street light bracket suitable for street/security light fittings upto 1.5 RM make out of GI pipe of light grade up to 40 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape and designed including taking down old corroded one complete
M&L for repairs in PVC, sheathed copper cable of 2.5 sqmm, 3 core for street light connection including taking down unsv PVC cable any type from steel pole /PCC pole /Jn box complete
S&F in repairs for street lighting timer panel with contactor, analog time switch, MCB rating 40 A suitable for 3 Phase 415 Volts and having over and under voltage protecction relay to protect the contactor coil, with panel locking facility, wall mounted type incl necessary cable lugs complete all as specified and directed. (Make- TL040AB0 Indo Asian or equivallent in Scheinder/Seimens/ Hager)
S&F in repairs for steet lighing timer panel, 1 phase,frame size 1, 6KW with digital 24 Hr.timer,32 Amp TP Contactor, 40 Amps SPN MCB incl necessary cable lugs, glands complete as in repair all as specified and directed. . Make Indo Asian or equivallent in Scheinder/Seimens/Hager)
S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 25 Watt including taking down old unserviceable one all specified and directed. (Make :Halonix/Philips/Wipro)
S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 45 Watt including taking down old unserviceable one all specified and directed (Make :Halonix/Philips/Wipro)
S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 60 Watt including taking down old unserviceable one all specified and directed . (Make :Halonix/Philips/Wipro)
S&F in repairs for large area flood lighting system LED type IP 66, pressure die cast housing, with heat resistant tempered glass for protection with surge protection system, 120 Watt including taking down old unserviceable one all specified and . (Make :Halonix/Philips/Wipro)
S&F in repairs for decorative LED post top fittings 25W Ruby Clear/Coral opal type IP 65 including with all accessories complete along with after taking down old unserviceable one all specified and Make :Halonix/Philips/Wipro) (Note: light grade GI pipe and necessary PCC works shall be measured and paid separately under relevant items)
S&F in repairs for garden light fitting 10 watts, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution including taking down old fitting, demoliton of brick/PCC work all as specified and directed. (Make :Crompton LBLSN 10 CDL or equivallant inHavells/Philips) (Note: Necessary PCC works shall be measured and paid separately under relevant items)
S&F in repairs for LED type IP 66, bush light with die cast aluminium having with toughened glass 9 W incl fixing arrangements complete all as specified and directed. (Make :HLOBVL-02-09-CW of Halonix/Philips/Wipro)
S&F in repairs for loop box out door type made out of Engineering plastic one piece moulding type,Bus bar rating 63 Amps 4 strips aluminium with bus bar mounting colour R,Y,B,N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colour, shock prrof, rust proof, fire retardant size 300x 200x 100mm with 10 Amps Kit kat fuse type, having front, opening and locking arrangement, duly fixed on the pole by MS clamp of suitable sizes, all as specified and directed. (Note:- Incoming and outgoing cables suitable size Lugs,Glands rate deemed to be included)
All as per above item but Single phase system 2 strips aluminium bus bar size of 200x150x100mm
S&F in replacement MCB, DP, 415 volts AC, 40 amps,10kA all as specified and directed. Make : Legrand/Havells/Indo asian
S&F in replacement MCB, DP, 415 volts AC, 63 amps,10kA all as specified and directed. Make : Legrand/Havells/Indo asian
S&F in replacement MCB, FP, 415 volts AC, 40 amps, 10kA all as specified and directed. Make : Legrand/Havells/Indo asian
S&F in replacement MCB, TP, 415 volts AC, 40 amps, 10kA all as specified and directed. Make : Legrand/Havells/Indo asian
S&Fin replacement MCB,SP,240 volts ,AC, 6 to 32 amps, 10kA all as specified and directed. Make : Legrand/Havells/Indo asian
S & F in replacement of MCCB, 4 pole, 415V AC, fixed type of following capacity; Make: Legrand/L & T /Indo asian/Havells
63Amps with breaking capacity 16kA
100 Amps with breaking capacity 16kA
125Amps with breaking capacity 16kA
160 Amps with breaking capacity 25kA
200Amps with breaking capacity 25kA
250 Amps with breaking capacity 35kA
400Amps with breaking capacity 36kA
S & F in replacement of MCCB, three pole, 415V AC, fixed type of following capacity; Make: Legrand/L & T /Indo asian/Havells
100Amps with breaking capacity 16kA
125Amps with breaking capacity 16kA
200Amps with breaking capacity 36kA
300Amps with breaking capacity 36kA
S&F in replacement of onload changeover switch, four pole, 415V AC,of following capacity; Make: HPL/Havells/Standard
M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing feeder piller, removal of complete LT feeder piller with necessary T&P, breaking of plinth, shifting and fixing of same feeder piller at new location including necessary eath work and PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) work as directed and connecting of incoming and outgoing cables, inclusive of two coats synthetic enamel paint of existing colour over one coat of primer, incl testing & commissioning etc., complete all as directed. Note: The cost of Aluminium thimbles/lugs and cable gland etc., as reqd at site is included in quoted rate.
M&L for PVC, sheathed Aluminium conductor cable of 6 sqmm, 2 core for electric poles to bldgs connection including taking down unserviceable PVC insulated aluminium conductor cable from Poles /Jn box all as specified and directed.. (Make – Finolex/Havells/Polycab)
M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing LT feeder piller indoor/out door type, powder coated painting over a cleaning, scrabing with salt paper and removal of dust particles complete with necessary T&P, and refixing the same as incoming and outgoing cables as existing.
S & F in repairs of LT panel Voltmeter digital type for 415 Volts, 3 phase system, rating 0-500 V complete suitable for operation of LT Panel all as specified and directed. Make: AE or equivallant
S & F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-200 A complete suitable for operation of LT Panel all as specified and directed. Make: AE or equivallant
S & F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-400 A complete suitable for operation of LT Panel complete (Make: AE or equivallant)
Supply only earth/ discharge rod suitable for 11 KV, single phase, highly insulated, FRP material, Telescopic type, smooth & glossy surface, push button type locking system, total 3 section, assembled length not less than 15 feet, top section dia not less than 25mm & bottom section dia not less than 45 mm, die cast aluminium earthing instrument for 30 mm dia, incl 6 sqmm copper cable not less than 06 mtr long, crocodile grouting clamp with cover complete
S&F in repairs for informatory/eqpt history sign boards of size not less than 900 x 600 mm rectangular type with 2mm thick MS sheet plain type made out of angle iron channels frame, back ground and epqt history details(i.e. Name, Make, Ser No,Capacity of eqpt, Vintage, SM/MES No etc.,) with high intensity retro reflective sheet letters as specified colours (blue and white) complete
S&F in repair for electrical shock and treatment and other safety charts,laminated and wall hanging type complete
S&F in repair fire Extinguisher CO2 (ABC type) maximum capacity of 4.5 Kg as per IS 2878 complete
S&F in repairs for lead acid batteries of 12 Volts, 150-180 AH, 22-28 plates,maintenance free type including accesories like terminal clamps, copper cable of required size and length, petroleum jelly and baterry initial charging all as specified and as directed. (Make Exide/Amar Raja/Luminious/HBL)
Supply, install, testing and commissioning of factory made LT panel of suitable size for 3 phase 415 Volts outdoor type cubical compartmentalised dust,weather,vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, suitable for including 800 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel and submit test certificate complete with following incoming/out going accessories:- (Make of panel- Adlec/SMS panels&switch gears/Tricolite, Make of ACB/MCCB/MCB- Havells/Indo asian,Make of accessories- L&T/AE) IN COMING - (a) ACB 630 A, 4P, 50 KA - 01 No OUT GOINGS - (a) MCCB 4 Pole, 415 volts, 315 Amps 36 KA - 03 Nos (b) MCCB 4 Pole, 415 volts, 160 Amps 25 KA - 01 Nos (c) MCCB 4 Pole, 415 volts, 100 Amps 25 KA - 02 Nos (d) Suitable rating accessories Digital Volt meter(01 No), Digital Ammeter(01 No),MCB 6 Amps SP 10 KA(03Nos), C.T.s 0-600Amps (03 Nos), R,Y,B Indicating lights(03 Nos) etc. complete
Supply, install, testing and commissioning of factory made APFC panel(2+3+5+5+10+25+25+25) 100 KVAR rating of suitable size for 3 phase 415 Volts intdoor type cubical compartmentalised vermin dust,weather and vermin proof fabricated out of 2 mm thick CRCA sheet powder coated openable doore with locking arrangement, necessary ventilation, suitable for including 200 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing unsv panel and submit test certificate complete with following incoming/out going accessories:- (Make of panel- Adlec/SMS panels&switch gears/Tricolite, Make of MCCB/MCB- Havells/Indo asian,Make of accessories- L&T/AE Make of capacitors - Epicos/L&T)) (a) MCCB 200, 4P, 25 KA - 01 No (b) APFC relays 8 stages- 01 No (c) VAF+ PF meter- 01 No (d) RYB indicating lamps - 03 Nos (e) C.T.s 0-200 Amps- 03 Nos (f) MPPH capacitors 02 KVAR round type -01 No (g) MPPH capacitors 03 KVAR round type -01 No (h) MPPH capacitors 05 KVAR round type -02 Nos (j) MPPH capacitors 10 KVAR round type -01 No (k) MPPH capacitors 25 KVAR round type -03 Nos (l) Capacitor duty contactors 05 KVAR - 04 Nos (m) Capacitor duty contactors 10 KVAR - 01 No (n) Capacitor duty contactors 25 KVAR - 03 Nos (o) MCB 10 A 3P 10 KA-04 Nos (p) MCB 20 A 3P, 10 KA - 01 No (q) MCB 63 A 3p 10 KA - 03 Nos (r) Automanual switches - 08 Nos (s) Red indication lights - 08 Nos etc.,complete all specified and directed.
Supply, install, testing and commissioning of factory made LT panel of suitable size for 3 phase 415 Volts outdoor type cubical compartmentalised dust,weather,vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, suitable for including 200 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel and submit test certificate complete with following incoming/out going accessories:- (Make of panel- Adlec/SMS panels&switch gears/Tricolite, Make of MCCB/MCB- Havells/Indo asian,Make of starter& contactors - L&T/C&S,Make of accessories- L&T/AE) (a) MCCB 100 A, 4P, 25 KA - 01No (b) Phase sequence relay (minilac) - 01 No (c) Power contactor MNX 50 A for reverse/forward - 02 Nos (d) Aux block 02 NO + 02 NC - 02 Nos (e) R,Y,B indicator lights - 03 Nos (f) Meter VAF + PF - 01 No (g) MCB 6 A, SP, 10 KA - 03 Nos (h) C.T.s 0-100 Amps- 03 Nos (j) MCB 16 A,3P,10KA- 03 Nos (k) O/L relay 4.5 to 7.5 Amps for 7.5 HP DOL starter - 03 Nos (l) Contactors MNX -12 type, 3 pole- 03 Nos (m) Aux block 2 NO+2 NC -03 Nos (n) Single phase preventor(minilac)- 03 Nos (o) Red & Green push buttons with elements - 06 Nos (p) Red & Green indicatiing lights - 06 Nos etc., complete all specified and directed.
Supply, install, testing and commissioning of factory made LT panel of suitable size for 3 phase 415 Volts intdoor type cubical compartmentalised dust,weather and vermin proof fabricated out of 2 mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, suitable for including 300 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel and submit test certificate complete with following incoming/out going accessories:- (Make of panel- Adlec/SMS panels&switch gears/Tricolite, Make of MCCB/MCB- Havells/Indo asian,Make of accessories- L&T/AE) Incoming - (a) MCCB 250 A, 4P, 25 KA - 01No Out goings - (b) MCCB 63 A, 4P, 16 KA - 06 Nos (c) MCB 20 A DP, 10 KA - 06 Nos (d) Suitable rating accessories Digital Volt meter(01 No), Digital Ammeter(01 No),MCB 6 Amps SP 10 KA(03Nos), C.T.s 0-250Amps (03 Nos), R,Y,B Indicating lights(03 Nos) etc., complete
Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete
M&L for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire of 4 mm dia as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of size 25 X 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete
S&F earth continuity conuctor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole/any other situation for loop earthing etc as required 4mm dia galvanised iron wire complete
S&F earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 25x4mm GI strip complete
Schdule of Credit - 87864.00)
HANUMAN BUILDERS
sony engineering works
SANJEEV ENTERPRISES
Shiv Enterprises
JM enterprises
Surjit and Sons
m/s VK construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .