Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-Finance | L1 | Accepted-Finance Found OK | |
| 2 | L2₹30.6 L+₹3,630 (0.12%)Accepted-Finance | L2 | Accepted-Finance Found OK | |
| 3 | L3₹31.9 L+₹1.3 L (4.29%)Accepted-Finance | L3 | Accepted-Finance Found OK | |
| 4 | L4₹37.3 L+₹6.7 L (21.9%)Accepted-Finance SHAHDARA | DELHI | 110095 | L4 | Accepted-Finance Found OK | |
| 5 | L5₹38.8 L+₹8.2 L (27.0%)Accepted-Finance | L5 | Accepted-Finance Found OK |
Tender Value
₹50.5 L
EMD Value
₹1.0 L
Closing Date
3 Aug 2022, 3:00 pmClosed
Executive Engineer (E)
O_o Executive Engineer E DTTDC Ltd Lajpat Nagar Site Office Near Cambridge School Ring Road Sriniwaspuri New Delhi 110065
Repair or replacing faulty light fixtures fans LV item and SITC of Highmast poles and Air conditioning etc. as required at SV CoEd School Id 1719105 Moti Bagh II Nanakpura New Delhi
2022_DTTDC_226584_1
03/DTTDC/Engg./EE(E)/2022-23
Open Tender
Composite Works
Item Rate
60 days
Moti Bagh Nanakpura
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.0 L
6 Aug 2022
22 Jul 2022
3 Aug 2022
22 Jul 2022
3 Aug 2022
22 Jul 2022
Amount
Supplying, installation, testing & commissioning of 16 mtrs. height High Mast Tower having in two sections, hot dip galvanized and suitable for wind velocity as per IS 875, bottom dia 450 mm and top 150 mm in polygon structure, comprising of winch (Double drum, SWL 750 Kg.) for raising/lowering, integral motor push button station, pulleys, head frame, lightning protection finial & buffers, resting on the foundation bolts duly provided with stiffeners, double locking arrangement for the door and pole installed on the existing RCC foundation complete as per specifications attached i/c supply and fixing following. a) Hot dipped galvanised steel high mast having 20 side polygonal structures in two sections with flanges provided with strengthening gussets between bolt holes for stiffening complete with raising/ lowering mechanism, double drum winch, motor push button station, pulleys, head frame, lightening protection finial and buffers, The sections shall be stress / slip fitted without any circumferential weld in between. - 1 No.
b) Galvanized Lantern carriage with 12 nos. arms secured tightly with suitable arrangement for fixing of 12 Nos. luminaires & other accessories complete etc. as required - 1 No. c) It shall include 3 point suspension system with accessories for high mast including steel wire rope of 8 mm dia (7/19 construction SS316), EPR trailing cable, double drum winch, suitable for 8 luminaires symmetrically & its control gear boxes and lightning finial. - 1 Set. d) Motor suitable to operate on 230V/400V, 50Hz, 960 RPM detachable type for lowering and lifting mechanism - 1 No. e) Supplying and drawing multicore, copper conductor flexible power trailing cables of appropriate rating for energizing the luminaries complete as per specifications attached - 1 Lot. f) Supply of Foundation bolts 12 nos. of PCD of Foundation bolts 750 mm type TS 600 of dia 32 mm dia and length of foundation bolts 850 mm long manufactured from special for steel along with nuts, washers, anchor plates & templates complete etc. as required.(For 16 mtr high mast foundation.) as approved by engineer in charge.
Designing & casting of suitable open raft type RCC shallow foundation for the erection of above High Mast as per the manufacturer design, adopting the safe soil bearing capacity of site at 10 T/Sq.Mtr at 2 Mtr below FGL including positioning of suitable foundation bolts, nuts, washers, pdg. straightening cutting and bending rings strictly as per design approved by engineer in charge and laying HDPE pipe of 100 mm (Inner) dia for cable entry at desired level complete with finishing plastering etc as reqd. a) For 16 Mtrs high masts.
Supplying, installation, testing and commissioning of Flood light orion with LED (Light Emitting Diode) system power: 150W, luminous flux of luminaire 15500lm, 5700K, cool white, CRI>70, 230V constant current driver, Pf>0.95, THD<10%, 70% of luminous flux after 50,000 operating hours, energy efficient LEDs, direct light emission, clear glass, housing in die-cast aluminium, polyester powder coated applied over a 5-stage pre-treatment, electronic control gear, Protection class I, IP66 L = 425mm, B = 320mm, H = 200mm etc as required. Make: Crompton LFLN-150-CDL/60-M or equivalent in Philips / Havellls
Supplying and fixing following sizes of PVC Insulated and PVC Round Sheathed un armoured Multi Core Flexible Copper Conductor Heavy Duty Industrial Cables for Voltage Grade 1100 Volts as per IS: 694:1990. on surface with suirtable clamps etc as required. - 3 x 4.0 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. - Upto 35sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. - Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. - Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. - Above 35 sq. mm and upto 95 sq. mm
Supply of one number PVC insulated and PVC sheathed/XLPE Al. UG Armoured Conductor power cable of 1.1 KV grade of following sizes in the existing RCC/HUME/METAL pipe/Duct/Surface of Flyover as per instructions of The Engineer-in-Charge as reqd. - 4 x 25 Sq.mm
Supply of one number PVC insulated and PVC sheathed/XLPE Al. UG Armoured Conductor power cable of 1.1 KV grade of following sizes in the existing RCC/HUME/METAL pipe/Duct/Surface of Flyover as per instructions of The Engineer-in-Charge as reqd. - 3.5 x 50 Sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
4 X 25 sq. mm (28mm)
3½ X 50 sq. mm (35mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. - 63 mm dia (OD-63 mm & ID-51 mm nominal)
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
6 x 2.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
3 x 6 sq. mm
6 x 6 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. - Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. - Group C
Supply installation testing and commissiong of 500 LPH drinking water plant with inbuilt RO, UV, Mineral, including providing suitable concrete foundation, raw water lifting pump, PSF, suitable water piping including providing the input and out put connections and food grade storage tanks 02 nos. up to 500 Litre connections inter connections etc as required. Make: Eureka Forbes / ION Exchange / Thermax
SITC of 2 TR split type AC units with suitable BTU/hr and copper condernser coil star rating not less than 3 star with refrigerent pipes suitable to work on 230 V 50 Hz supply etc as required. Make : Daikin / Lloyd / Ogeneral
Providing and fixing addition Refrigerant copper pipes for cool and hot refrigerent with insulation proper clamping on surfae/ recess etc as required.
SITC of 2 TR Low static Concealed type Duct Air coditioning unit linar flow 3 side suction indoor with high throw and copper condenser out door unit non inverter R-32 refrigerent suitable to work on 230 V 50 Hz AC etc as required. Make: Daikin / Lloyd / Ogeneral
Supplying, Installation, Testing & Commissioning of wall mount type 5 KVA Voltage Stabilizer with input 160-300 volt and output 200-240 Volt with under voltage and highvoltage cutt-off and with TDR etc. complete as reqd. Make: V-Guard / Microtek / Bluebird
Repair/replacement of recess type 2 x 2 LED fixture of system wattage of not less than 36W and the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: CRCA Powder Coated. IP20 , Optics: PMMA/Polysterene Diffuser. The operating CCT shall be not less than 5700K with CRI of ≥80 including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing suitable to work on 230 V, 50 Hz AC supply etc. as required. (including removing the old fittings handver to client). Make: PHILIPS RC380B LED42S -6500 G4 L60 W60 PSU OD or equivalent in Crompton / Havells
Repair/replacement of recess mount downlight Round Led Downlighter consuming a system wattage of 15W and the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: CRCA Powder Coated. IP20 , Optics: PMMA/Polysterene Diffuser. The operating CCT shall be not less than 5700K with CRI of ≥80 including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing suitable to work on 230 V, 50 Hz AC supply etc. as required. (including removing the old fittings and hand over to client). Make: PHILIPS DN193B LED12S-6500 PSU WH S2 or equivalent in Crompton / Havells
Repair/replacement of of surface mounted LED downlighter, the power consumption of fixture is 15-18W and producing a lumen output of 1100 lumen. The fixture has Mid Power LED's integrated with an efficient optical system to provide high DLOR. Construction of fixture is High Efficiency White Reflector along with High Transitive in Diffuser and CRI > 70 complete with all accessories etc. as reqd. Make: PHILIPS SM251C LED20S- 6500 PSU WH or equivalent in Crompton / Havells
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply of ceiling fans up to 1200 mm sweep including wiring canopy connections interconnection by removing the exising fan suitable to work on 230V 50 Hz AC supply etc as required. Make: Havells / Crompton / Orient
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Servicing of the existing water cooler of capacity not less than 80 L including changing the filters, membrane, cleaning the storage tank replacing the faulty parts and making good for checking the water testing etc as required.
SITC of 5 KVA single phase in signgle phase out online UPS with 30 min back up including batteries, rack and stands etc. as required. Make: Vertiv / Rittal / Gutor / Tmeic
SUNNY A/C CENTRE HUF
BHARDWAJ ENTERPRISES
RAMESH ELECTRIC WORKS
Ashok Kumar Gupta & Co
Vasu Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .