Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.9 CrAccepted-AOC 48 19 6 2ND FLR MVR COMPLEX DWARAKANAGAR OPP RTC COMPLEX VISAKHAPATNAM 530003 | VISAKHAPATANAM | ANDHRA PRADESH | 530003 | ₹50.9 Cr | L1 | Accepted-AOC Being L1 and reasonable tender |
| 2 | L2₹61.3 CrRejected-Finance | ₹61.3 Cr | L2 | Rejected-Finance Not being the lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not fulfilling Pre qualification criteria as per NIT |
| 4 | Rejected-Technical PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | - | - | Rejected-Technical Not fulfilling Pre qualification criteria as per NIT |
Tender Value
₹51.2 Cr
EMD Value
₹15 L
Closing Date
23 Mar 2020, 6:00 pmClosed
CE NAVY MUMBAI
26, ASSSAYE BUILDING, COLABA, MUMBAI, PIN-400005
PROVISION OF ADMIN CUM TRAINING BLOCK AND ANCILLARY FACILITIES AT INS MANDOVI
2019_MES_293613_2
87781/E8
Open Tender
Civil Works
540 days
VASCO
As per Tender documents
9 documents required · 9 mandatory
₹3,000
Yes
GE(P) VASCO
₹15 L
Yes
16 Oct 2020
7 Feb 2020
25 Mar 2020
7 Feb 2020
23 Mar 2020
9 Mar 2020
7 Feb 2020 - 17 Feb 2020
Amount
SCH 'A' PART-I "BUILDINGS & STRUCTURES" Total of Sch-'A' Part-I B/F to BOQ(Schedule ‘A’) Serial Page No. 42(R)
SCH 'A' PART- II "SITE CLEARANCE, EXCAVATION & EARTH WORK. Total of Sch "A" Part-II B/F to BOQ at Sl page No 44-A
SCH 'A' PART-III "INTERNAL WATER SUPPLY" Total of Sch "A" Part-III B/F to BOQ at Sl page No 45 (R)
SCH 'A' PART-IV "INTERNAL ELECTRIFICATION" Total of Sch "A" Part-IV B/F to BOQ (Schedule 'A') on Serial Page No 49
SCH 'A' PART-V "ROAD/ PATH / CULVERTS" Total of Sch "A" Part-V B/F to BOQ on Serial Page No 51
SCH 'A' PART-VI "CHAIN LINK FENCING & GATE " Total of Sch "A" Part-V B/F to BOQ on Serial Page No 52 (R) -A
SCH 'A' PART-VII "RETAINING WALL" Total of Sch "A" Part-VI B/F to BOQ (Schedule 'A') on Serial Page No 54 (R)
SCH 'A' PART- VIII "AREA DRAINAGE" Total of Sch "A" Part-VIl B/F to BOQ (Schedule 'A') on Serial Page No 55
SCH 'A' PART-IX "SEWAGE DISPOSAL" Total of Sch "A" Part-VIII B/F to BOQ (Schedule 'A') on Serial Page No 57(R)
SCH 'A' PART-X "LIGHTIENING PROTECTION" Total of Sch "A" Part-XI B/F to BOQ (Schedule 'A') on Serial Page No 59
SCH 'A' PART-XI "FIRE FIGHTING" Total of Sch "A" Part-X B/F to BOQ (Sch 'A') on Serial Page No 64 (R)
SCH 'A' PART-XII "LIFT" Total of Sch "A" Part-XI B/F to BOQ (Schedule 'A') on Serial Page No 66 (R)
SCH 'A' PART-XIII "DG SET" Total of Sch "A" Part-XII B/F to BOQ (Schedule 'A') on Serial Page No 67
SCH 'A' PART-XIV "EXTERNAL WATER SUPPLY" Total of Sch "A" Part-XIII B/F to BOQ on Serial Page No 70
SCH 'A' PART-XV "EXTERNAL ELECTRIC SUPPLY" Total of Sch "A" Part-XIV B/F to BOQ (Sch 'A') on Serial Page No 78 (R)
SCH 'A' PART-XVI "RAIN WATER HARVESTING TANK & STP" Total of Sch "A" Part-XV B/F to BOQ (Schedule 'A') on Serial Page No 80 (R)
SCH 'A' PART-XVII "COOLING APPLIANCES" Total of Sch "A" Part-XVI B/F to BOQ (Schedule 'A') on Serial Page No 81 (R)
SCH 'A' PART-XVIII "AIR CONDITIONING" Total of Sch "A" Part-XVII B/F to BOQ (Sch 'A') on Serial Page No 86
SCH 'A' PART-XIX "DEMOLITION" Total of Sch "A" Part-XVIII B/F to BOQ (Schedule 'A') on Serial Page No 89
SCH 'A' PART- XX" MISCELLANEOUS ITEMS"
"INTERNAL WATER SUPPLY"
S&F of continental 2way bore bib taps (wall mount installation type) of brass,knob controlled,with chrome finish Make - Jaquar Model No Con-041KN.
S&F Angular stop cock quarter turn(wall mount) with 1/2 inch hole diameter made of brass Make - Jaquar Model No ARI-CHR-39053.
S&F for Stainless steel concealed stop cock, Regular body with adjustable wall flange, size 1/2inch dia, Make - Jaquar Model no CON-CHR-083KN.
S& F overhead shower round shape single flow (ABS body crome plated with gray face plate) with rubit cleaning system Make - Jaquar Model No OHS-18736
** S&F Florentine Pillar cock with extended liver(medi series) of brass, knob controlled, Make - Jaquar Model No. CHR -031
S&F Health faucet (ABS body) with 01 meter long PVC tube & wall hook. Make - Jaquar Model No ALD-CHR- 583 or equivalent in Crab Tree/Kohler brand.
S&F PVC connections 1m long of size 1/2 inch with end fiiting brass(drinking water pipe) jaquar brand.
S&F Brass Urinal flush valve of 1/2 inch diameter (installation type :wall mount) jaguar model-snr-chr-51097
S&F jaguar plastic concealed cistern tank with kit(item part no: JCS -WHT-2400S, Primary material : Plastic,Capaciy: 2x3)
S & F Brass LONG NECK BIB TAP, handle controlled,wall mount installation type, Make - Jaquar Model No. CON -021KN
S & F Mixerof brass has a long pipe to connect shower. jaguar model-CON-273KNUPR
"INTERNAL ELECTRIFICATION"
S & F Lamp holder insulated body with back plate and Including LED lamp 9 watt for angle holder all as per specified
S & F LED light fittings decorative 36/34 Watt Recess/surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED light fittings decorative 36/34 Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make-WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x8/9 Watt ( for mirror light) ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED Security/Street light fittings 15 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Fabricate,supply & fix GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 15w ssecurity light fitting
MCCB DB VERTICAL TYPE suitable for 250 amps MCCB as incommer made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTH004DD/ LEGRAND / schneider/ ABB ( main DB for
MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913/ / schneider/ ABB
MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 100 Amps
MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps
MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps
MCB SP 40 Amps 'C' series, breaking capacity 10 KA of rating
MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98603OOOO /Legrand cat no-420013/schneider cat no-LV510315
MCCB TPN 100 Amps , 415Volts, 25KA ,4 POLE L&T CAT NO-CM91198OOLO/ LEGRAND CAT NO-420055 / / schneider/ ABB
MCCB TPN 250 Amps , 415Volts, 25KA ,4 POLE L&T CAT NO-CM90634OOPO/ LEGRAND / schneider/ ABB
S&F Exhaust fan heavy duty of size 230 mm sweep metal body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make Make , - Havells/Crompton Greaves/Bajaj
S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. ( for Tech Building & Adm Building ) -Make : Crompton Greaves/ Bajaj/Orient
Supply & fixing wall mounted fan 450 mm sweep high speed, thermally protected motor, heavy duty gear box, 90 degree oscillation for wide coverage conforming to IS-2997-1964 all as specified and directed by Engineer-in-Charge. , Make-Havells/Crompton Greaves/Bajaj/Orient
M&L for non metalic PVC rigid conduit of size 25 mm dia including bend ,tee,elbow reducer fixing accessorries
M&L for PVC junction box up to 4 Way
M&L for telephone jak with Modular metal flushed including flushed Box cover plate Box for 2 Way module
M&L for TV SOCKET with Modular metal flushed including flushed Box cover plate Box for 2 Way module
S &F enclosure flush mounting type SUITABLE FOR MCB TPN 2 WAY with MCB Spn 6 Amps ( Aviation light )
AVIATION LIGHT type,LED TYPE IP 65 protection cat no -SLE AL 54 -LDR-SEN IP65 of SURYA /BAJAJ cat no -BGAV 302 LED/PHILIPS
Hand Dryer
S &F modular AC Box sheet metal with socket 3 pin, suitable for 20 Amps flush type universal including 20 amp c series MCB protected.
S&F cat's eye reflective type plastic body 100 x 100 x 26mm Complete all as specified and Dierected Make:- 3M / AUTOMATE
M&L 80mm thick grass concrete paver M-35 over 50mm thick sand cushion , over 100mm thick WBM, over 150mm thick hardcore ,Then fill the layer of sand , compact the same and then lay a leyer of top soil and then plant the grass.
"CHAIN LINK FENCING & GATE FOR T / F"
Precasted RCC post of 150x150mm along with chamfer
Precasted RCC post of 150x150mm at corner post
FIRE FIGHTINING"
S & F Gun metal one way fire hydrant valve of size 63 mm dia flange type complete with instantaneous coupling complete.
Construction of brick masonary valve chamber of size 900x900x750 mm (internal diamension) above ground level 40 mm suitable for 100 mm dia sluice valve, 40 cm thick foundation using FCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) over 15 cm thick hardcore, 23 cm thick brick wall butts in cement and sand motor 1:4, 15 cm thick internal and external plaster including top floor in cement and sand motor 1:3, finished even and smooth, without using extra cement, 10 mm thick mild steel plate cover on 50 mm x 50 mm x 6 mm MS angle iron frame embeded in PCC 1:2:4 type 6-1 (using 20 mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangement & handle made out of 25 cm dia MS round bar, hold fast etc, applying one coats od red oxide primer and two coats of synthetic enemelted paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not ex 50 mtr complete.
supply and fix flowswitch (Switzer/Oanfoss) on pipes with welded socket including stainless steel paddle suitable to pipe dia. 150 mm testing and commissioning etc. complete.
supply and fix suitable Air release single valve (Zoloto/ZIP) of 150mm dia including. necessary support and painting with two coats of enamel paint over a coat of primer etc. complete, for wet riser termination.
Supply & fix alarm check valve for sprinkler system size 150mm dia ,cast iron body complete all as specified.MAKE : TYCO TYPE
Supply & fix control valve for sprinkler system size 100mm dia ,flanged end B16.5 class complete all as specified.MAKE: FLANGED END AS PER ASME B:16.5, MODEL NO: DMCV 01
Supply &fix control valve for sprinkler system size 50mm dia ,flanged end B16.5 class complete all as specified.MAKE: FLANGED END AS PER ASME B:16.5, MODEL NO: DMCV 01
Fire Extinguisher water type 9 Ltr capacity. Ceasefire 9Ltr Water type Fire Extinguisher, Stored pressure Type, Pressure Gauge,Gross Weight 14.6 Kg, empty Weight 5.6 Kg, Can Height 611MM, Diameter 175MM,Discharge Time less than 120 Secs, Controllable discharge mechanisum, Range minimum 6 mtrs applicable on class a fire a rating 13A, can construction : deep drawn & CO2 Mig welded, valve construction : Forging & machining internal coating of Can : Epoxy p[owder coating, External coating of Can : Epoxy polyster powder coating sheet meta thickness : 2.0MM, ISI and EN Approved, Hileum Leak Detection tested, 1 year warranty. Make Cease Fire Water-9 Ltr Stored Pressure - 1CO02CF.
Fire Extinguisher DryChemical powder[ABC] type 9 Kg capacity. Ceasefire 9kg fire extinguisher mono Ammonium phosphate powder 50, stored pressure type, pressure Guage, Gross weight 15.6 Kg, empty weight 5.6 KG, can height 611 MM, Diameter 175 MM, discharge time less than 18 secs, controllable discharge mechanism, Range minimum 4 mtrs, applicable on class A,B,C & electrically started fire A rating 27A, B rating 558, can construction deep down & CO2 Mig welded, Valve construction : Forging & Machining internal coating of can : Epoxy powder coating external coating of Can : Epoxy polyster powder coating, Sheet metal thickness : 1.80MM, ISI and EN approved, 5 years warranty.Make Cease Fire ABC Powder Map 10 5Kg - 1AB06CF
Fire Extinguisher Carbin Dioxide type of 4.5Kg capacity.Ceasefire 4.5kg CO2 Gas typre fire Extinguisher, Trolly mounted, Easy weight management Used Unused Mechanism Squeeze Grip, Gross weight 9.1kg empty weight 14.6kg, Can height 857MM, Diameter 140MM, Discharge timeless than 10secs controllable discharge mechanism Applicable on class B&C fire, B rating 21B, Can Construction : Hot Spinning/ Forging, Valve Construction : Forging & Machining, Internal coating of Can : Not Applicable, External Coating of Can : Spray painting sheet metal thickness 4.5MM, ISI Approved 1 year warranty. Make Cease Fire CO2-4.5Kg - Squeeze Grip - 1CO11CF
Fire Extinguisher Carbin Dioxide type of 3kg capacity.Ceasefire 3 kg CO2 Gas typre fire Extinguisher, SQUEEZE TYPE, Easy weight management Used Unused Mechanism Squeeze Grip, Gross weight 9.1kg empty weight 14.6kg, Can height 857MM, Diameter 140MM, Discharge timeless than 10secs controllable discharge mechanism Applicable on class B&C fire, B rating 21B, Can Construction : Hot Spinning/ Forging, Valve Construction : Forging & Machining, Internal coating of Can : Not Applicable, External Coating of Can : Spray painting sheet metal thickness 4.5MM, ISI Approved 1 year warranty. Make Cease Fire CO2-4.5Kg - Squeeze Grip - 1CO11CF
Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity.Ceasefire 9litrs fire Extinguisher AFFF Foam type , External Cartridge type, Pressure Guage Gross weight 14.6 Kg , empty weight 5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge timeless than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A,B,Can construction deep deawn & CO2 Mig welded Valve Constyruction : Forging & Machining, Internal coating of can : Epoxy powder coating, External coating of can : Epoxy poyster powder coating sheet metal thickness 2.0MM ,1 year warranty. Make Cease Fire AFFF - Foam 9 Ltr - 1FM02CF
Fire Extinguisher dry chemical powder trolly moutnted of 9Kg capacity. Ceasefire 50Kg Fire Extinguisher MONO Ammonium Phosphate powder 90, Gross weight 125Kg, Empty weight 75KG, Can height 1190MM, Diameter Discharge Time leass than 50 Secs controllable discharge mechanism range minimum 8Mtrs, Applicable on class A,B,C & electrically started fire, Can Construction deep drawn and CO2 Mig welded valve construction Forging & machining internal coating of Can, Epoxy powder coating External coating of Can Epoxy Polyster powder coating sheet metal thickness 5.00MM 1 year warranty. Make Cease Fire.Make Cease Fire ABC Powder map 90 50Kg - 1MP50CF
Fire Extinguisher clean agent of 4Kg capacity. Ceasefire 4Kg Fire Extinguisher MONO Ammonium Phosphate powder 90, Gross weight 125Kg, Empty weight 75KG, Can height 1190MM, Diameter Discharge Time leass than 50 Secs controllable discharge mechanism range minimum 8Mtrs, Applicable on class A,B,C & electrically started fire, Can Construction deep drawn and CO2 Mig welded valve construction Forging & machining internal coating of Can, Epoxy powder coating External coating of Can Epoxy Polyster powder coating sheet metal thickness 5.00MM 1 year warranty. Make Cease Fire.Make Cease Fire ABC Powder map 90 50Kg - 1MP50CF
FIRE Bucket
Supply &Fix First aid Hose reel with shut OFF valve 30mtr long and 20mm dia
Supply and fix CI foot valve, flanged end and drilled of size 150 mm dia ISI MARKED , FLANGED TYPE
Supply and fix CI foot valve, flanged end and drilled of size 100 mm dia ISI MARKED, FLANGED TYPE
Supply and fix CI foot valve, flanged end and drilled of size 50 mm dia ISI MARKED, FLANGED TYPE
"DG SET"
(a) Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 160 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following.
(b)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make: Kirloskar/ashok leyland/cummins
(a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator.
(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump.
(v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 24V Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop
(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-24 volts(02x12vBattery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.
(c) Alternator: Suitable rated 160 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) Make: stampford/crompten/kirloskar
(d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 160 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-
(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton.
(e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(f) AMF control circuit with 4 pole MCCB 250 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.
(g) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.
(h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
Supplying, installing , testing and commissiong, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 40 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire , 415 volts 50 Hz ± 1% supply, 150 RPM< directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following
Deisel Engine: Liquid cooled turbo charged with after cooler to delilver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 1002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories. Diesel engine of rated speed at full load electric start developing with system with radiator and including elctronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make: Kirloskar/ashok leyland/cummins (a) Raditor with blower fan or heat exchanger with guard (b) Pipe coupling for engine cooling system piping (c) Corrosion inhibator coolant (d) Paper element fillters (i) fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator (g) Shut off coil with safaries for LLOP/HWT/over speed (h) Dry type air cleaners and vaccum indicators. (j) Stainless steel exhaust flexible bellows. (k) Motor driven priming pump (l) Battery charging alternator (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control.
(r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump. (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 24V Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-24 volts(02x12vBattery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed .
(c) Alternator: Suitable rated 40 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) Make: stampford/crompten/kirloskar
(d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 40 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton.
(e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(f) AMF control circuit with 4 pole MCCB 63 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.
(g) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.
(h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
Supply, Installation, test and Commissioning CPRI approved factory fabricated, outdoor type, LT Pannel Board made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (location - near transformer) for D.G Set 160 KVA Pannel.
(a) MCCB 400 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM94105OOR1OG / Legrand cat no-025538 / schneider cat no-LV540309 - 1 no
OUTGOINGS:-
(a) MCCB TP 160 Amps , 415Volts, 35KA ,3 POLE, L&T CAT NO-CM92008OOM1OG/ LEGRAND CAT NO-420087 / equivalent of ABB- 1 NO (O/G) for fire fighting main panel
(b) MCCB 250 A 35 KA, 3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no-CM92009OOP1OG /Legrand cat no-420239/schneider cat no-LV525333 -02 No ( for DG main DB TPN 4 way.)
(c) MCCB TP 40 Amps , 415Volts, 35KA ,3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98602OOOO /Legrand cat no-420013/schneider cat no-LV510316 - 8 nos (for main water supply pump panel 7.5 hp , Lift 4 nos , building pump panel 5 hp & st. light)
(d) Aluminum TPN bus bar 600 Amps - 01 Set
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(h) Astronomical, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T cat no- T2 DD T7/MDS/GIC - 1 no
(j )Power contactor ML-3 , 3 pole rating not less than 40 A with 230 coil make L&T/SEIMENS - 1 no.
(k ) mcb spn 6 amps-1 no.
"EXTERNAL WATER SUPPLY"
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 550 LPM discharge at 30 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building)
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 550LPM discharge at 120 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete ,complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for UGsump & fire sump).
Supply install test and commissiong of monoblock pump set , electric driven complete with all accessories suitable for pumping water 90LPM discharge at 30 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete ,complete all as specified and directed.Note 1 : Suction and delivery pipes shall be measured and paid under appropriate items ( rain water harvesting) Note 2 :-( MS Shed for RWH pumps of required size will be provided as per specified and Deirected by Engg-in-Charge However MS Shed made of MS Angle 50 x 50 x 6 mm & 45 cm Height and Covered with GI Sheet with Powder Coating , Rate of item is included in this item.
Note for item no 27.01 to 27.03 - Energy Efficient Motors-Motors shall comply with following a. All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors b. Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64% c. Motor horse power rating shall not exceed 20% of the calculated maximum load being served,d. Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor e. Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices f. Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Taking down and Refixing CI pipe including fitting/fixture & connection including cleaning CI iron pipes with spigot and socket ends centrifugally cast, any class, in any length laid in trenches of size 200 mm dia complete all as specified and directed
Taking down and Refixing CI pipe including fitting/fixture & connection including cleaning CI iron pipes with spigot and socket ends centrifugally cast, any class, in any length laid in trenches of size 150 mm dia complete all as specified and directed
Taking down and Refixing CI/GI pipe including fitting/fixture & connection including cleaning CI/GI iron pipes any class/GRADE, in any length laid in trenches of size 100 mm dia complete all as specified and directed
Taking down and Refixing CI/GI pipe including fitting/fixture & connection including cleaning CI/GI iron pipes any class/GRADE, in any length laid in trenches of size 80 mm dia complete all as specified and directed
Supply and laying Ductile iron pipes with spigot and socket ends centrifugally cast, Class K-9, in any length laid in trenches of size 200 mm dia Incuding rubbur Tytan joint
Supply and fix CI sluice valve Kirloskar/Upadhyay/L&T MAKE both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of sizes :-200 mm dia
Supply and laid spigot/flanged/ socketed DI fittings. Such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc of size 80mm to 300mm dia.
Supply and fix CI sluice valve Kirloskar/Upadhyay/L&T MAKE both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed of sizes :-100 mm dia
Supply and fix CI sluice valve Kirloskar/Upadhyay/L&T MAKE both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed of sizes :-80 mm dia
Supply and fix CI double end flanged and drilled non return valve of size 200 mm dia PN-1.6 ISI MARKED Kirloskar/Upadhyay/L&T MAKE
Supply and fix gunmetal non return valve of size 50 mm PN-1.6 dia ISI MARKED Kirloskar/Upadhyay/L&T MAKE
Supply and fix CI foot valve, flanged end and drilled of size 100 mm dia ISI MARKED
Supply and fix CI foot valve, flanged end and drilled of size 50 mm dia ISI MARKED
Supply and fix CI 'Y ' Strainer screwed end or flanged type conforming to IS, size 100 mm dia.
Supply and fix CI 'Y ' Strainer screwed end or flanged type conforming to IS, size 50 mm dia.
Construction of brick masonry valve chamber of size 1200x 1200x1200 mm (internal dia) suitable for 150 mm dia sluice valve with necessary earth work excavation plain cement concrete 1:4:8 using 40 mm graded stone aggregate 75 mm thick in cement mortar 1:6 15 mm thick plastering 1:6 inter nally including flooring and externally rep to 15 mm below ground level plain cement concrete 1:4:8 type B1 using 20 mm graded stone aggregate in coping MS sheet cover made out of 3 mm thick MS sheet flat iron frame and bracing with locking arrangement applying two coat of synthetic enamel paint including dismantling removing the existing damage chamber completely removal of debris to a distance not exce eding 50 mtr distance depositing where as directed by Engr –
Supply and fix Cast Iron Air Valves 50 mm dia with single air Outlets, conforming to IS 14845 for Cast Iron Water supply mains of size 200 mm dia.
Supply and fix gunmetal non return valve of size 80 mm PN-1.0 dia ISI MARKED Kirloskar/Upadhyay/L&T
EXTERNAL ELETRIFICATION:
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, in door type, LT panel board ,made out of 2 mm thick CRCA Sheet with Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands, Aluminium Busbar TPN 400 Amps, PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( main water supply pump House at Tapping point )
INCOMING:-
(a) Incoming MCCB 200 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98605OOOO /Legrand cat no-420055/schneider cat no-LV510317-01 No
OUTGOINGS:-
(a) MCCB TP 63 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos (For main pump)
(b)Automatic Starter delta starter for 35 HP pump -02 Nos( For main pump)
(c) MCCB TP 100 Amps, 50 Hz, 415 Volts, 25 KA -01 Nos (For Exsisting pump pannel)
(f) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(g) Single phasing preventer -02 No
(h) MCCB TP 32 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos (For capacitor & light load)
(j) power capacitor bank , Utra heavy duty, BOX type Oil filled, LTXL OF L&T or equvalant of APCOS/siemens/momaya suitable for 480V,12.5 KVAR- 1 no
(k) Space for Electric energy meter
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, LT panel board ,made out of 2 mm thick CRCA Sheet Aluminium Busbar TPN 100 Amps Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( For building pump )
INCOMING:-
(a) Incoming MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98603OOOO /Legrand cat no-420013/schneider cat no-LV510315-01 No
OUTGOINGS:-
(b) Outgoing MCB, TP 32 Amp, 25 ka, 415 volts -02 Nos
(c)Automatic Starter delta starter for 7.5 HP pump -02 Nos( For main pump of building )
(d) single Phase Preventer -2 nos
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(h) msb spn 6-32 amps-02 No
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX ,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and Cable Glands & Aluminium Busbar TPN 50 Amps PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( for Rain water harvesting and STP)
INCOMING:-
(a) Incoming MCCB 32 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider-01 No
OUTGOINGS:-
(b) Outgoing MCB, TP 16 Amp, 415 volts -02 Nos ( for Rain water harvesting)
(C) DOL starter suitanble for 5 HP motor- 2 nos
(d) single Phase Preventer -2 nos
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(g) msb spn 6-32 amps-02 No
Taking down unservisable U/G LT cable from trenches, wall, floor etc and removing to store for safe custody Note:- Excavation for taking will not paid for separatly, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables
Taking up of under ground HT Cable of any size along with protection cover/ bricks and removing from site all as directed by Engr-in-Charge.
Disconnecting the existing HT/LT cable from transformer terminal and taking down Transformer of 50KVA TO 500 KVA capacity from position and shift to new location on pole/ PCC platform including reconnection of existing HT/LT cable connection incl transportation distance not Exc 2500 meters of capacity up to 500 KVA complete all as specified and directed
Taking down partly unserviceable / unserviceable ,SECURITY/STREET/GATE/FLOOD light fittings from pole/tower for necessary repair , all as specified and directed Engr-in-Charge
supply & fix battary bank with AGM VRLA batteris 2 volt, 100 AH for operation of VCB including connectors
Battary charger 0- 50 amps floating type
Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, LT Pannel Board made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (location - near transformer)
INCOMING:-
OUTGOINGS:-
(b) MCCB 630 A 35 KA, 3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM94104OOT1OG /Legrand cat no-025540/schneider cat no-LV540310- 1 no APFC PANNAL (1)
(d)MCCB 400 A 35 KA,3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no-CM98401OOROOG /Legrand cat no-4220 60/schneider cat no-LV540309 -2NO (O/G) For ( for AMF panel& Spare)
(c)MCCB 250 A 35 KA, 3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no-CM92009OOP1OG /Legrand cat no-420239/schneider cat no-LV525333 -03 No. (Building main DB 250 amps as incommer-2 nos & Spare)
(m) Aluminum TPN bus bar 2000 Amps - 01 Set
(p) Space for Electric energy meter
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
Supply and fix LED street light fitting 45 Watts complete with bracket made out of 40mm dia GI light grade tubing not less than 1.5mtr long bent to shape 120 deg including pole clamps (2no), clamp for fixing GI conduit pipe bracket made out of 50x6mm flat and nut bolts and 15mm GI LG for controle cable from top of SMC box to bottam of light fitting bracket, washers etc all as directed
Area lighting LED 90/100 Watts, energy saving environmental friendly, long life exclusive innovatiive die cast aluminium IP 66 flood light with high power LED as light source suitable for high lighting architectural features or retail spaces Make : WIPRO /HAVELLS JETA linear/JAQUAR /PHILLIPS
S & F LED Bolard light fittings 6 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Supply & fix PVC junction box IP 65 Protection of size 0.200 x 0.250 x 0.115 complete with 1 Nos of MCB SP 2.5 Amps & 4 way industrial connector including Clamp made out of MS flat 30X5 mm, connection from junction box to street light fitting with three single core PVC insulated , PVC sheathed wire 2.5 Sqmm copper & PVC coduit 20 mm dia. Make of Box- SPELS BERG/RITTAL/HENSEL CAT NO K8350
Supply and fix cable route indicator made of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B1 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
AVIATION LIGHT type,LED TYPE IP 65 protection cat no -SLE AL 54 -LDR-SEN IP65 of SURYA /BAJAJ cat no -BGAV 302 LED/PHILIPS
S &F enclosure flush mounting type SUITABLE FOR MCB SPN 2 WAY with MCB Spn 6 Amps ( for Aviation light )
Supply only electric rubber hand gloves 11 KV
Disconnecting the existing HT/LT cable from Lt pannel of any size from position and shift to new location on PCC platform including reconnection of existing HT/LT cable connection incl transportation distance not Exc 2500 meters complete all as specified and directed
Supply and fix LT bus duct air insulated type made out of 3mm thick CRCA sheet flanged type of suitable cross section with copper bus bars three phase and half neutral of 2000A capacity including fitting and fixture ie. End flexible joint, bend 90 degree, Tee, adoptor box Endcover, hanging/support arrangment for horizontal, spring hanger for vertical installation duly supported on DMC /FRP insulators including provision of suitable supports from ground for outdoor portion of bus duct with canopy &from roof for indoor portion of bus duct, painting the bus duct with two coats of synthetic enamelled paint over a coat of red oxide primer and connection with flexible laminated copper strips of same capacity at both transformer and LT panel complete all as directed and specified Makes : L&T/schneider/ABB.
(a)Supply & Fix elecronic energy trivactor meter,suitable for 3 phase 4 wire CT operated ,temper proof,operated on 240v AC ,three phase, 5 amps to 10 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-0.5, MD recording, revenue protection ( in case of wrong electric connection),capability to disply & communicate ( in case of absence of main supply), with optical port,deficiency metering with either phase/netral current, IP 51 protection, as per IS13779,, L&T model no- ER300P & Cat no-WR300BC5200 of L&T or equivalant of secure
current trasformer (CT) 1600x 5 amps
current trasformer (CT) 150x 5 amps
APFC PANEL
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, outdoor type, APFC capacitor bank Panel Board of size as recommended by manufactrer 200 KVAR with 8 steps ( 50 + 25 + 25 + 25 +25+25+12.5 + 12.5) WITH MD-XL CAPACITOR AND MCCB AS INCOMER Automatic Power Factor Correction panel ,outdoor type, double door, made out of 3.15 mm thick CRCA Sheet Dust and Vermin Proof, with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System,The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified .The panel shall be factory fabricated comprosing of following. Make of pannel L&T/ SCHNEIDER/ABB
(A) INCOMER
MCCB 630 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM94104OOT1OG /Legrand cat no-025540/schneider cat no-LV540310- 1 no (Thermal Magnetic Release)
ROM+SPDR - 1 no
Auxiliary 1 c/o +TAC 1 c/o- 1 no
(B) OUTGOING CAPACITOR FEEDERS : -
I.) 50KVAr Capacitor feeder comprising of:- ( 1No. )
160A, BUSSMANN FUSE type 160EET - 3 nos
Thyristor switching module 50kVAR, 440V,TSM,LTTSM- 1
7% Detuned Aluminium Reactor 50KVAr 440V,LTAL,CAT NO-0750B2 -1
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 30 kVAr,sutable for 480V ,LTXL - 2 nos
Push Button ON/OFF -2 nos
Indicating lamps 2 nos
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage, MX-0 type -1
6A DP MCB ,C-CURVE-1
II.) 25 KVAr Capacitor feeder comprising of:- ( 5 Nos. )
80A, BUSSMANN FUSE 80ET,-15 nos
Thyristor switching module 25kVAR, 440V , TSM,LTTSM-5 nos
7% Detuned Aluminium Reactor 25KVAr 440V
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 30 kVAr,sutable for 480V , LTXL - 5 NOS
Push Button ON/OFF -10nos
Indicating lamps 10 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 5
6A DP MCB , C CURVE 5 NOS
III.) 12.5 KVAr Capacitor feeder comprising of:- ( 2 Nos. )
40A, BUSSMANN FUSE- 6 NOS
Thyristor switching module 25kVAR, 440V,TSM,LTTSM - 2 NOS
7% Detuned Aluminium Reactor 12.5KVAr 440V LTAL,CAT NO-0712B2- 2 NOS
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 15 kVAr,sutable for 480V
Push Button ON/OFF -4nos
Indicating lamps 4 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
6A DP MCB , C CURVE 2 NOS
Precasted RCC post of 150x150mm along with chamfer .
APFC PANNEL INCOMER METERING APFC relay 8 stage {BLR CM - 06T MB} - 1 NO [ 230/110 V , 1/5A , 50Hz} [Transistor output + Single CT sensing + RS 485 MODBUS]
Digital Voltmeter (3Ph, Class 1) -1 NO
Digital Ameter (3Ph, Class 1, 5A) -1 NO
Metering CT --/5A, Class-1- 3 NOS
SMPS 5A, Input 230V AC Output 24V DC -1 NO
ON Delay Timer 0-10 Sec.,Coil 24V DC -1 NO
Auxiliary Contractor { 4 NO} with 24 V DC} - 3 NOS
Indicating Lamp (R,Y,B) - 3 NOS
6A SP MCB-3 NOS
6A DP MCB
6A FP MCB -1 NO
8" {EBM NADI} Fan -1 NO
SOLAR PANEL 100KW
Supply , erecting, installing , testing and commisioning of grid connecting Solar Photovoltaic power plant of 100KWp capacity including solar grade copper cable upto UPS, array junction boxes including mounting structure with single axis self powered tracking system as per conditions prevailing at Goa comprising of following sub components / sub system and meeting the specifications as given subdsequently all as specified and dierected by Engineer-in-Charge. Note : The design of Solar power plant to be vetted by National Institute of solar energy (NISE) or independent agency approved by MNRE. a) To obtain 100 KWp minimum Poly crystalline silicon solar PV modules of 325 Wp each having high efficiency , fill factor more than 0.74 plant performance ratio more than or equivalent to 75 % and made of high transmissivity glass front surface shall give high encapsulation gain, (Transmittance above 90 % and bending less than 0.3 % ) Electrical parameters of 325 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum and temperature 250o C will be as under .( Connected items are mentioned below).
(i) Rated output of modules shall have positive tolerance of 3-5 % and no negative tolerance is allowed.(ii) It shall perform satisfactory in relatively humidity 100 % with temperature 0 to 10 C to (+) 85 C (cell) and should withstand wind pressure 185 km/Hr on the surfaceof the panel. (iii) PV modules must be warranted for their output peak watt capacity , which shall not be less than 90 % of the initial value at the end of 10 Years and 80 % of the initial value at the end of 25 years. of (iv) Each module shall have radio frequency identication ( RFID) tag bearing the following details. RFID reader will be provided by contractor. (a) Name of manufacturer of PV module (b) Name of manufacturer of solar cell (c) Month and year of manufacture (Separated for cell & module) (d) Country origin (separately of solar cell & module) (e) Peak wattage, Im, Vm and fill factor of the module. (f) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (g) Unique Serial No. and Model No. of Module. (h) I-V curve of module (v) The temperature co-efficient for the module shall notbe more than 0.50%/C. (vi) Every odule must have by pass diode of suitable capacity. (vii) PV module must confirm o latest edition of IEC 61215/IS : 14286. IN addition the modules must conform to IEC 61730 Part - I & II for construction and testing & safety qualification.
(viii) It shall also be in conformity of atest minimum technical specifications issued by MNRE from time to time. (ix) Provision of earthing & earth strip/ cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor onthis account. (x) RFID reader to be provided by contractor.
(b) Junction boxes : Supply and fix 4 (Min) Numbers of dustvermin and waterproof Array Junction Boxes and 4 Nos main junction boxes madeof FRP/Thermo Plates with IP 65 protection in complince with IEC62208 and shall be sunlight/UV resistance and well of ire retardant including over voltage protection, surge protection and manintenance free earthing as per relevant standard. The junctionboxes shall have suitable arrangements of followings: (i) Strings are required to be connected to the busbar through individual fuses with provision of arrangement for disconnection for each of the groups. (ii) Provision of a testpoint for each subgroup for quick fault loaction and to provide group array isolation. (iii) Each array junction box will have suitable by pass and reverse blocking diodes for maximum DC blocking voltage of 1000V with suitable arrangements for its connection. reverse blocking and by-pass diodes shall work for temperature extremes and shall have efficiency of 99.98% conformed by appropriate IEC standard.
(c) cables : Suitable size of XLPE insulated copper cable of solar grade, 1100 volt & UV resistance and flame retardant for outdoor installations conforming IEC 60227/15694 & 60502/IS 1554 (Pt I &II). All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment condition including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 Years and volatge as per latest IEC/IS n standards. All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. Size of cable shall be such that maximum voltage drop at full power from PV modules to invertor shall be less than 1.5% including diode voltage drop. cable Batch No./drum No. IS code and size make should be printed/ embossed at every one metre. The wiring of modules interconnection shall be in suitable size GI/HD pipe. Note: Cost of interconnection copper cables along with cable trays (floor/wall mounted) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor.
Supply , fixing and commissioning of 50 KW - 02Nos, crystalline silicon normal string type grid tie power inverter outdoor type 3 phase 415 Volts 50+ 3 Hz, suitable to convert DC power of solar PV module/ array to AC for further feeding to grid confirming to IEC- 61683 for efficiency, IEC- 62109 (1&2) or equivalent for safety and IEC - 62093 for reliability with reverse polarity protection complete all as specified. The inverter shall include appropriate self protection and self diagnostic feature to protect iteself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal and external causes.Inverter shall have protected arrangements against ground leakage faults, over voltage (SPD) & over current. Inverter shall have arrangements for adjusting DC input current and shall strip against sustainable fault down stream and shall not restart till fault is rectified.The inverter should hav the provisions of Galvanic isolation, Anti-islanding protection (IEEE 1547/UL 1741) equivalent BIS stranded and lightening.
Lightning Protection for PV Array Design, supply & fix Lightning Arrestor-02 Nos, of required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning Arrestors/ surge arrestors shall conform to IEC 600994 or IS:3070 except to the extent modified in the specifications.Arrestors shall be hermitically sealed units, self supporting constructions, suitable for mounting on lattice type support structures. The air terminal is Early Steamer Emission (E.S.E) type which shall be fixed at the top of a GI elevation pole with base so as be at leasr 2 meters above structure to be protected. Its height above roof level would be dependent on the level of protection radii required. The air terminal should be working on the principles of early steamer emission using non- radioactive technology, needing no external power source. The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lighting rod. The air terminal is of stainless steel and it has qualified diameter to resist high values of lighting currents. Roof connecting pipe should be capable of withstand in lightinf strikes havind dimension 50 mm ID and 60 mm OD. The terminal adaptor having inner dia 60mm OD. Note : Cost of all equipments, copper strip unto earth test point etc are included n this item. However cost of earthing will be paid searately to the Contractor under relevant item.
Supply, lay and fix along the poles for passig through pipe, in trenches or under floor et. XLPE insulated armoured heavy duty cable 1100 Volts grade with aluminium conductor of cross sectional area 3.5 core x 95 Sqmm from Inverter to LT panel.(Length as required)
Supply, laying and fixing along the poles or passing through pipes or laid under floor of through walls etc. jointing and testing (XLPE insulated) galvnised steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with Copper conductor and overall served with an outer sheated of PVC, of cross sectional area 70 Sqmm with required number of runs/phase single core and 1 run for neutral suitabe for 3 phase systewm to lead ealectric supply from inverter to main panel.(Length as required) Note-I : One run of 70 sqmm cable will measured as one unit complete all as directed Note -II : Excavation, earth work, Sand cushioning, Cable covers, Pipe for cable protection are included)
supply, installation, testing and commissioning of factory made LT cubical panel - 01No, outdoor type suitable to accommodate the following accessories made out of CRCA sheet 3.15mm thick duly power coated with Siemens grey shade RAL 7032, totally enclosed, dust and vermin proof with working voltage of 450V, 50 Hz, 3 phase 4 wire ,fully compartmentalized, for each control gear having back side of panel openable, and shall be provided with suitable louvers for ventilation including suitable size of MS medium channel of size 75 mm and necessary foundation work providing PCC 1:2:4 B1 with 20 mm graded aggregate. Bus Bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitable colour coded with heat shrinkable sleeve for phase indiction. The standard phase arrangement when facing the switch gear shall be R-Y-B from left ro right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon themin ordinary working due to fixing, vibration, fluctuations in temp, short-circuit
or other causes. The bus bar will be supported on DMC. provisionshall be made for expansion and contraction of the bus bars and connections woth variation on temp. Inteernal wiring should be done 2.5sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeve etc. The bottom of the panel shoud contain detachable plate having provisionof entry of armoured cable of adequate size with glands. Threaded earthing studs -02 Nos shall be shall be provided at the bottom and lifting lugs of suitable size at top of lift the panel safety shall be made .The cubicle incomer MCCBs as well as outgoing shall have copper 4 pole / TP extenison links of current rating not less than 1.5 times the rated capacity of individual feeders. The cubicle should be inclusive of following (male : ABB/ Siemens/ Adlec legrand/L&T )(Note : Due to space constraint in enterance door of substation panel should be detahable type to enter the substation in two/three parts as required at site):-
Incoming (a)MCCB 125 Amps 25 KA , 415 volt 4 pole, thermal magnetic release 50 HZ Make:Legrand/ Siemens/ Schneider -2 nos (B) Mulitfunctional meter having LCD display , AC Make L&T/ System Control & switchgear/ Schneider Electric (c)LED indicator lamp showing Red,Yellow ,Blue (d)Copper bus bar of capacity 400 Amps for phases and neutral Outgoing (a)MCCB with microprocessor release 4 pole 50 KA. 250 Amps electrically motor operated draw out type make : Legrand / Schnider /L&T
M &L for maintenance free UL approved copper bonded Earth Rod of 10 feet length, 17.2mm dia made out of high tensile low carbon steel rod, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness -250 microns and lenght of 3 meters). with exothermically jointed copper bus bar of 50 x 6 x 200mm for connection. the rod and exothermic joint successfully tested (Short time withstand current at 20 KA rms for 1.0 & 50 KA peak) by CPRI.With 50 Kg /Electrode Eco friendly Earth enhancing compound with each rod. The compound should comply to IEC - 6256-7 having passed TCLP (toxic test), resistivity test (0.2 Ohm M), leaching, corrosion,sulphur & resistivity test as per IEC 62651 -7 by NABI accredit Lab with FRP inspection pit cover. The rate shall include excavation of earth, filling with black filled compound, and earth pit making, The complete installation shall be as per the drawing and technical specifications. Make: JMV LPS Ltd/ OBO/ ENNOV Infra Solutions Pvt Ltd/ERICO/Power Bolt
Suply and fixing Gross Metering system along with CT,PT including structural work complete all as specified and dierected.(01 Unit) NOTE:- i)All necessary permissions of integrating the 100 KW solar plant with the existing GSEB / local agencies. The rate / amount quoted is deemed to be inclusive of this aspect and no claim whatsoever shall be entertained at later stage. ii) Outsourcing of services for Comprehensive maintenance , operation and repair including spares required till defect liability period is deemed included in the contract sum quoted by the contractor and nothing extra shall be paid for the maintenance, operation and repair of solar power plant till the completion of defect liability period. iii) The employment of manpower and other details for maintenance, operation and repair during defect liability period shall be strictly as specified for Ph-II of the work
Supply and layinf PVC insulated flexible copper cable of size 1 x 70 Sqmm for connection from earthing to lighting terminal complete all as specified.(Length as required)
Supply, laying and testing of RS-485 copper cable of size not less than 0.5 Sqmm, 2 pair , metal screened, armoured, PVC insulated copper conductor cable complete with round type lugs and coppper glands all as specifeied and directed.(Length as required) Make: Polycab, Havells, Glostar or equivalent from the list of makes.
Supply and installation of LT outdopor type panel 02No of suitable size, factory manufactured CPRI approved made out of 03mm thick CRCA sheet duly powder coated paint IP-65, with 200 A rated bus bar and 125 Amps MCB isolator 4 pole and with appropriate ventiliation complete all as apecified and directed.
M&L for installation of weather station and monitoring system covering temperature sensors, pyronometer wind velocity sensor etc complete all as specified and directed. Make : JAS (Jambekar Automation System), AERON ( Pune) , or equivalent consisting of equipments of makes specified in PS.
Supply and installtion of data logging kit for all inverters and monitoring the same remotely complete all as specified and directed.
Supply and installation of PC with 17" LED screenwith 2TB HDD, 8GB RAM, 8GB graphics card etc. for monitoring system complete all as specified and directed.Make: HP/DELL/ACER/HCL
Supply and fix copper eart strip 20x 3mm size complete all as specified and directed.(Length as required)
COOLING APPLIANCES
Supply & Fix Voltage Stabilizer for Automatic Operation Single Phase naturally air cooled indoor type & design for input variation between 170V to 250V with Output Voltage Stabilizer at 230V with accuracy of +/- 2.5 % and of Capacity 1.0 KVA.
AIR CONDITIONING
Supply, installation, testing and commissioning of water cooled SCREW twin compressor chilling machines 3 Nos Each of 100 TR (minimum) capacity, (2 Nos working and 1No Stand by) at below mentioned parameters with R-134a refrigerant multi-hermetically sealed SCREW compressor driven by suitable KW squirrel cage induction motor, Star/Delta Starter with water cooled shell & tube condenser, insulated shell and tube flooded chiller should be designed for 12 deg C/6 deg C, flow switch at chiller and condenser outlet, suction and discharge refrigerant piping with heat exchanger globe, strainer, expansion valve, solenoid valve and antifreeze thermostat, first charge of refrigerant gas and oil, microprocessor based control panel all mounted on MS frame, vibration isolators and other accessories etc, including necessary foundation. The compressor motor shall be suitable for 400 V +/- 10%, 50 HZ +/- 1% 3 Phase AC supply. The Chiller performance should be as per ECBC Publication for COP and IPLV. Typical Noise level (Sound Pressure) at 1 Meter distance from the Chiller and 1.5 Meter height 75 decibel (i) The chiller shall have an ARI certification label at no extra cost. Test certificate from ARI shall include capacity (TR/KW), Power (KW/TR), Pressure drop (ft of water), Integrated Part Load Value (IPLV) and shall be submitted. Note:(i) AC plant has to maintain temp 21+/-2⁰C & RH 55+/-5%.
All purchase Certificates and Test certificates shall be produced. Proof of Purchase from OEM be provided No Foreign Exchange or import licence will be provided by Department. Condenser: CDW in 90 Deg F CDW out 99.5 Deg F Fouling factor 0.001(hr-sq-ft-deg F)/Btu Chiller: CDW in 52 Deg F CDW out 43 Deg F Fouling factor 0.0005 (hr-sq-ft-deg F)/Btu (ii) Micro processor type panel board with compressor starter. Chiller should have been minimum COP 3.00 as per E-in-C policy and IPLV-6.43 (minimum) (The chiller software should have open protocol (BAC-net/Modbus) to connect with BMS system) (2 W + 1 SB)
Supply, installation, testing and commissioning of CENTRIFUGAL horizontal pumping sets for chilled water circulation system. The pump shall be suitable for the given duty points - 3 Nos Each (Out of Three pumps 10HP, Two will be working and one will be standby) (i) Water Quantity - 240 USGPM (ii) Static Head - 30M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - Hig Tensile steel (vi) Pump/motor body - CI (vii) Seal - Mechanical (viii) Motor - Suitable HP TEFC (ix) Starter - Star-Delta (x) Base frame - Fabricated MS Note:- One set consist of Three Pumps
Supply, installation, testing and commissioning of CENTRIFUGAL pump set for condenser, Horizontal directly coupled pump of suitable discharge and head for condenser circulation system. The pumps shall be suitable for the given duty points operation - 3 Nos.(Out of Three pumps 15hp, Two will be working and one will be standby). All parameters as per Condenser pump as under (i) Water Quantity - 400 US GPM (ii) Static Head - 25 M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - High Tensile steel (vi) Pump/motor body - CI (vii) Seal - Mechanical (viii) Motor - Suitable HP, Squirrel Cage SPDP (ix) Starter - Star-Delta (x) Base frame - Fabricated MS Note (i) Condenser and Primary chilled water pumps flow should match with chiller requirement. (ii) No price adjustment will be done due to variation in flow of pumps. (III) One set consist of Three Pumps
Supply install testing and commissioning of following items :-
(a) Supply, laying, fixing, testing and commissioning of Pot Strainers 150 mm dia
(b) Supply, laying, fixing, testing and commissioning of Needle Valve 25 mm dia
(c) Supply, laying, fixing, testing and commissioning of Pressure Gauge
(d) Supply, laying, fixing, testing and commissioning of Thermometer
Supply, laying, fixing, testing and commissioning of Balancing Valve Heavy duty with insulation (conforming to ISS-1239-1958 and 3589-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, of following sizes :-
(a) 150 mm dia
(b) 100 mm dia
Supply installation testing and commissioning low density polyethylene drain pipes size 50 mm dia (LDPE) of pressure rating 4 Kg/cm² on walls/ceiling or laying in floors including fixing with pipe fittings and material as per site requirement and all as directed
Supply, laying, fixing, testing and commissioning of 'Y' Strainer with MS class ' C' (Heavy conforming to ISS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, decaling valves of 150 mm dia.
Supply, laying, fixing, testing and commissioning of 3 way pressure Independent Balancing cum control valve along with actuator and step down transformer with temperature sensor with 3C x 1.5 sqmm control cable from AHU panel to 02 way valve assembly and controller. (The valve should close 100% on stopping of AHU) of suitable capacity
Supply, laying, fixing, testing and commissioning of Purge Valve
Supply, laying, fixing, testing and commissioning of Expansion bellow 150 mm dia
Supply, Constructing, Installation, testing and commissioning PVC make-up water tank for cooling tower feed/makeup water 10000 liters. The job includes for make-up water connection from existing pipe line tapping etc. and staging for the tank, head adequate to feed the cooling Tower basin
Supply, laying, fixing, testing and commissioning of closed Expansion Tank 1000 liter with insulation complete air separator, pressurization units having two pumps, sediment separator, pressure switch, piping, valves, fittings & control panel. (at plant room)
Supply, installation, testing of Supply Air Diffusers of extruded Aluminium sections duly powder coated with black volume control Damper complete all as specified and directed by Engineer in Charge.
Supply, installation, testing of Return Air Diffusers of extruded Aluminium sections duly powder coated with black volume control Damper complete all as specified and directed by Engineer in Charge.
Supply, installation, testing of supply Air Grilles of extruded Aluminium sections duly powder coated with black volume control Damper complete all as specified and directed by Engineer in Charge.
Supply, installation, testing of Return Air Grilles of extruded Aluminium sections duly powder coated with black volume control Damper complete all as specified and directed by Engineer in Charge.
Supply, installation, testing and commissioning of automatic Fire damper as required for operation, including necessary control wiring complete all as specified and directed by Engineer in Charge.
Humidifier :- Supply install testing and commissioning of pan humidifier for winter season with connecting pipe with all accessories, valves etc. from tank with necessary heaters and connection wiring complete with humidistat all as directed for the following.
i) 5 KW (for AHU1,4,5&3)
ii) 2.5 KW (for AHU2)
Supply, Install, Testing and Commissioning of thermostats, humidistat and Air stat for monsoon/winter condition (1 SET each bank)
Supply, Install, Testing and Commissioning of thermostats, humidistat and Air stat for monsoon/winter condition (1 SET each bank)
Supply and fixing, Install, Testing and Commissioning of Insulation as per Technical Specification for the following :-
(a) Supply, Installation, Testing and Commissioning of Thermal Insulation for outside Supply air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3 " wide aluminium foil faced self adesive tape at all joints as per the specifications and approved drawings.
(b) Supply, Installation, Testing and Commissioning of ACCOUSTICl inside Insulation for Supply air ducting with 13 mm thick OPEN cell elastrometric Nitrile rubber and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade.
(c) Supply, Installation, Testing and Commissioning of Thermal Insulation for outside return air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3 " wide aluminium foil faced self adesive tape at all joints as per the specifications and approved drawings.
supply, laying , fixing , testing & commisining of heater banks as per specification and in multi bank of following sizes
(i) Heater bank as per specs. in multi bank 50 KW (in 5banks)
(i) Heater bank as per specs. in multi bank 40 KW (in 4banks)
(i) Heater bank as per specs. in multi bank 25 KW (in 2 banks)
Non-chemical type on-line scale preventor of suitable capacity of the following size of Make : Scale Ban / Scale-X / Scale Off / Scale Guard.
M&L for Lockable Push button for cooling tower
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor mounting, dust and vermin proof cubical type, CPRI approved, LT panel fabricated from 2.0 mm Indoor type thick CRCA sheet duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket, voltmeter, ammeter, APFC Relay, Frequency meter. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade suitable for 600 amps with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm throughout the length of bus bars , including suitable aluminum earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper copper/ aluminum lugs. The cubical incomer MCCB as well as outgoing shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 500 mm long supported on suitable size `F` class insulator to be provided for termination on incomer and outgoing cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on bottom channel of suitable size with proper mounting arrangement as directed by Engr-in-Charge leaving min 500 mm all around the panel board for movements all as specified with supply and fixing the following:-
Supply, installation , testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing , floor/wall mounting , dust and vermin proof cubical type , CPRI tested, LT panel fabricated from 2.00 mm thick CRCA sheet , duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening ) , locking arrangement with chromium plated 19mm dia fancy locks ( min 2 Nos in each compartment ) , lifting lugs of suitable size on top louvers and air vent gasket for natural air, 'U' shape rubber gasket. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemen Grey shade (RAL-7032) , Protection class IP 43 , fully compartmentalized design with 4 Nos of bus bars made of copper of ETP garde with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mountedon suitable size 'F' class insulators made of non hygroscopic , non combustible, track resistance , high strength FRP / SMC/ DMC material at an interval not more than 500mm through out the length of bus bars including suitable aluminium earth strip , with danger notice plate , necessary cable glands, cable connection with proper aluminium / copper lugs , The cubical incomer MCCB as well as out goint shall have copper TPN extension link of current carrying capacity not les than 1.5 times the rated capacity of indiviual feeders. The extension link of min 200 mm long supported on suitable side `F` class insulator to be provided for termination on incomer and out going cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on angle iron frame of size 1X0.75X0.40m and further mounted on PCC foundation and pedestal having min 300 mm all around the feeder pillar board for movements all as specified with supply and fixing the following(for AHU 2).
Note : (i) Drawing of LT panel and make of items to be got approved from Eng-in-Charge before ordering the panel. (ii) Cost of lugs for cables and cable gland etc also included in unit rate of panel.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor/wall mounting, dust and vermin proof cubical type, CPRI tested, LT panel fabricated from 2.00 mm thick CRCA sheet , duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia fancy locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of bus bars including suitable aluminum earth strips, with danger notice plate, necessary cable glands, cable connection with proper aluminum/ copper lugs, The cubical incomer MCCB as well as out going shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 200 mm long supported on suitable side `F` class insulator to be provided for termination on incomer and out going cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on angle iron frame of size 1X0.75X0.40m and further mounted on PCC foundation and pedestal having min 300 mm all around the feeder pillar board for movements all as specified with supply and fixing the following(for AHU3).
Note : (i) Drawing of LT panel and make of items to be got approved from Eng-in-Charge before ordering the panel. (ii) Cost of lugs for cables and cable gland etc also included in unit rate of panel.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor/wall mounting, dust and vermin proof cubical type, CPRI tested, LT panel fabricated from 2.00 mm thick CRCA sheet , duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia fancy locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of bus bars including suitable aluminum earth strips, with danger notice plate, necessary cable glands, cable connection with proper aluminum/ copper lugs, The cubical incomer MCCB as well as out going shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 200 mm long supported on suitable side `F` class insulator to be provided for termination on incomer and out going cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on angle iron frame of size 1X0.75X0.40m and further mounted on PCC foundation and pedestal having min 300 mm all around the feeder pillar board for movements all as specified with supply and fixing the following(for AHU 1,4 &5 ).
Note : (i) Drawing of LT panel and make of items to be got approved from Eng-in-Charge before ordering the panel. (ii) Cost of lugs for cables and cable gland etc also included in unit rate of panel.
Cooling Appliances supply and fix refrigerator electric driven (single phase) , capacity 165 liter BEE 5 star rated
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilizer at 230V with accuracy of +/- 2.5 % and of capacity 0.5 KVA.
Smart Metering Supply and fix smart energy meter GSM based, 3 phase 4-wire 0.5 class , tamper Proof features, with isolated communication for RS 232, Rs 485 and Optical ports , time of day metering (8 TOD slots) , built in LI-ion Battery , built in Zigbee Module for 865 MHZ or 2.4 Ghz for down stream , rugged power supply with wide range of operation from 80 to 500 v AC line voltage , top cover open and Magnetic tamper sensor and fraud detection , any make of CMRI can be used to read meter data , self diagnostic capability , display type pc monitoring , security password protected user login and parameter setting all as specified including sets of CTs (Model no - CT2M)
Supply & fix electronic energy trivactor meter , suitable for 3 phase 4 wire CT operated , temper proof , operated on 240v AC , three phase , 5 Mps to 10 Amps , base mounting meter , backlit LCD display with user friendlylegend, accuracy class-0.5, MD recording , revenue protection (in case of wrong electric connection ) , capability to display & communicate (in case of absence of main supply ), with optical port 485 , deficiency metering with either phase / neutral current , IP 51 protection , as per IS 13779 including sets of CTs of suitable size , make of meter - L & T model no - ER300P & Cat no - WR300BC5200 of L & T or equivalent of secure
Supply and Fix Btu meter (digital) for chilled water consumption all as specified .(for each AHU return supply side) MODEL NO (-BTU6430)
M & O of Lifts Comprehensive maintenance and repairsof fully automatic electrically operated passenger lifts of any make and installed capacity with a carrying capacity of 08/13 Passenger to serve (G+4,G+4,G+3 Floors) with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories , simplex collective automatic & manual dual controlled operation with / without attendant , automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system , 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each car , Machine room & Near Ground floor Landing door ) comprising of all devices and accessories through 60 months for all days including holidays etc after expiry of defect liability period as shown below and all as specified and dierected by Engr-in-Charge Note:- Contractor shall carryout comprehensive maintenance ( routine, daily , weekly ,monthly, quarterly , half yearly ,yearly ) as per attached Performa and maintain all the lifts in serviceable condition 24 hrs x 365 Days without any extra cost.
1st Year after expiry of defect liability period.
2nd Year after expiry of defect liability period.
3rd Year after expiry of defect liability period.
First (11 Months after completion)
Second (11 Months after completion of Phase 2(a) above )
Third (11 Months after completion of Phase 2(b) above)
Fourth (11 Months after completion of Phase 2(c) above)
Fifth (11 Months after completion of Phase 2(d) above)
Sixth (05 Months after completion of Phase 2(e) above)
Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of chilled water type central air conditioning plant of capacity 300 TR installed, comprising of all devices and accessories through out 12 months on all days including sundays & holidays for a period of 03 years after expiry of defects liability period (i.e. 24 months after completion of all Phase II tests) all as specified and directed and as shown below:-
(a) 1st year after expiry of defect liability period.
(b) 2nd year after expiry of defect liability period.
(c) 3rd year after expiry of defect liability period.
Manning & operation of chilled water type central AC plants for a period of 60( sixty) months[ for two shifts of eight hours duration (0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs)] for all days in a week including sundays & holidays with all instruments and controls complete as specified as under and as directed by Engineer-in-charge.
(a) First (11 Months after completion
(b) Second(11 Months after completion of Phase 2(a) above
(c) Third(11 Months after completion of Phase 2(b) above
(d) Fourth (11 Months after completion of Phase 2( c) above
(e) Fifth (11 Months after completion of Phase 2(d) above
(f) Sixth (05 Months after completion of Phase 2(e) above
NOTE:- (a) The contractor shall be responsible for periodical maintenance, as per maintenance schedule attached and specified including renewal / replacement of parts, fittings / fixtures filling of refrigerant gas etc required for smooth functioning of the plant as per manufacturers instructions. (b) The Contractor shall Employ Refrigeration mechanichaving minimum ITI qualification from Govt Recognised institute with adequate knowledge & minimum 2 years experience in maint/operation of AC plants. The operator must competent to carry out the minor maint all as directed. (TOTAL number of operators required per day are 02 nos.). (c) Contractor shall pay the wages to the employees through e-payment i.e Adhaar linked bank accounts (credit to their bank account). Engineer-in-charge shall ensure that e-payment made to employees and their wages shall not be less than minimum wages fixed by state Govt or Central Govt whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Engr-in-charge and the same shall be kept in record duly verified.
Som Projects Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.07 MB
Download all tender documents and submit your bid