Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 CrAccepted-AOC | ₹11.5 Cr Quoted ₹11.7 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹12.7 CrRejected-Finance | ₹12.7 Cr | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹14.1 CrRejected-Finance | ₹14.1 Cr | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹15.9 CrRejected-Finance | ₹15.9 Cr | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹19.9 CrRejected-Finance | ₹19.9 Cr | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹12.2 Cr
Closing Date
15 Dec 2021, 6:00 pmClosed
Chief Engineer AN Zone Military Engin
Headquarters Chief Engineer AN Zone Military Engineer Services Birchgunj Junglighat Post Port Blair 744 103
Demolition and Re-construction of bldg. No P-18,P-19, P-20, P-27, P-29, P-30, P-35, P-38 and P-43 at Vijay Baugh Junglighat, Port Blair
2021_MES_484572_1
801205/E8
Open Tender
Civil Works
730 days
Port Blair
Refer tender documents.
9 documents required · 9 mandatory
₹3,000
Yes
Exempted
31 Dec 2021
28 Oct 2021
22 Dec 2021
28 Oct 2021
15 Dec 2021
1 Dec 2021
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part - I to XI are prepriced by MES under Ser No. 2.00 to 12.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “BUILDINGS/STRUCTURES” as listed in Schedule ‘A’ Part - I , inserted by MES
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - II , inserted by MES
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - III, inserted by MES
Lumpsum price worked out by the tenderer for "SEWAGE DISPOSAL " as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for "EXCAVATION AND EARTHWORK INCLUDING SITE CLEARANCE" as listed in Schedule ‘A’ Part- V
Lumpsum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part- VI
Lumpsum price worked out by the tenderer for "ROAD / PATH / CULVERT/HARD STANDING" as listed in Schedule ‘A’ Part- VII
Lumpsum price worked out by the tenderer for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part- VIII
Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part- IX
Lumpsum price worked out by the tenderer for "DEMOLITION/DISMANTLING" as listed in Schedule ‘A’ Part- X
Lumpsum price worked out by the tenderer for "PILE FOUNDATION" as listed in Schedule ‘A’ Part- XI
Subtotal
NOTE: Schedule ‘A’ Part - XII (miscellaneous) are not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
INTERNAL ELECTRIFICATION Supply and fix single phase key based BIS marked liberty static energy meter tamper proof electronic AC 240V,50 Hz with LCD display with polycorbonate cover, accuracy class-I, 50 Hz, unit of current rating range 05-30 A measures confirming to IS 13799,IP-54 with parameters to show data, time, current reading, load, PF, voltage and KWH including internal wiring using PVC cable copper conductor of size 2.5 Sqmm and necessary testing, commissioning etc with the following :- (a) Supply and install vending soft wire - Liberty on line with 02 Nos VascoKey. (b) Supply and install tariff designing customer data based defination, Liberty on line. (c) Including maintenance of one year after date of completion of work.
Supply and fix ceiling fan, 5 star rating , energy efficient BLDC (Brushless Direct Current) motor with regulator and smart remote controlled suitable for convert from 230 V AC to 24 V DC, 1200mm sweep,28 W power, down rod and canopy rating and thw colour of milky white including anchor flusher, ceiling hook for fixing of fan on ceiling complete all as specified and as directed.
S&F PVC Exhaust fans 225 mm sweep single phase 230 Volt 50 Hz heavy duty, 1400 rpm, energy efficient smooth functioning with suitable size of louver including fixing arrangement, opening of hole, anchor fasteners, 1.5 sqmm 3 core wire from ceiling rose to fan all as specified and as directed.
S&F PVC Exhaust fans 300 mm sweep for kitchen single phase 230 Volt 50 Hz heavy duty, 1400 rpm, energy efficient smooth functioning with suitable size of louver including fixing arrangement, opening of hole, anchor fasteners, 1.5 sqmm three core wire from ceiling rose to fan all as specified and as directed.
Supply and fix indoor wall mounting mirror light fitting 12 Watt, 2 feet inbuilt electrical protection like overvoltage, short circuit and over loading driver with high efficiency and low power loss with high transmittance efficiency.
Supply and Fix LED type tube light fittings 4 feet long 1x20 W 230V ,decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient tube light life time 40,000 burning Hrs, lumen output 2000lm, color temp-6000K,Surge protection of 2kV with voltage protection 160-360V, power factor >0.9 complete & prewired for LED tube complete fixed to wall / Ceiling by suitable down rods, PVC round blocks and connection by flexible PVC cable with stranded copper conductor from ceiling rose to connector of the fitting including 1x20W LED tube complete all as specified.
Supply and fix LED 18 W, slim design profile surface/ ceiling mounted downlight with options of 700 to 2000 lumen suitable for indoor spaces ( verandah/ passage/ balcony/lobby), energy efficient fitting decorative type complete including housing all pre wired with high efficiency electronic driver complete fixed to wall/ceiling including connection by flexible PVC cable with stranded copper conductor including LED tube complete all as specified and as directed.
Supply and fix LED bulb (Bipin holder type) 10 Watts complete all as specified and as directed.
Supply and fix energy saving and environmental friendly long life LED 19 Watt bldg security light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection including all fixing arrangement, brackets, nut bolts, washer and connected from ceiling rose with tri colour flexible copper cable complete as specified and as directed.
Supply and fix MCCB thermal magnetic TPN (4P) 415 V 40 Amps 25 KA Capacity.
Supply and fix MCCB thermal magnetic TPN (4P) 415 V 40 Amps 25 KA Capacity.
ROAD/FOOT PATH/HARDSTANDING M& L for providing 2.5mm thick road marking strips (reflective) of specified shade/colour using hot thermoplastic material by fully automatic thermoplastic paint applicator machine, fitted with profile shoe, glass beads dispenser, propane tank heaters and profile shoe, heater, driven by skilled operator on road surface including cost of materials labour, T&P, cleaning the road surface of all dirt, scales oil grease and foreign materials etc. strictly in accordance to applicable specifications including scrubbing out old worn out markings etc. complete, all as specified and as directed.
M&L for Aluminium stud two way reflective model No DA 971 of dimension 110 x 128 x 29.5mm Aluminium Alloy body Reflective panel - Amber, Red of White complete all as specified and as directed.Make: Dark Eye / Avery Dimension /Alexis Enterprises
EXTERNAL WATER SUPPLY Taking down existing old CI/DI pipe of size 150mm bore
Taking down existing old GI pipe of size 100mm bore
Taking down existing old GI pipe of size 20 to 40mm bore
Taking down existing Sluice valve of size 80 mm bore
Taking down existing Sluice valve of size 100 mm bore
Taking down existing Sluice valve of size 150 mm bore
M&L for Construction of masonry valve chamber of size 1000 x 1000 x 750 mm internal size, 150 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with precast solid block masonry set in cement mortar 1:4, 15MM thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth without using extra cement , 10 SWG thick MS sheet cover including MS angle frame of size 40 x 40 x 6mm fixed in coping PCC 1:2:4, type B1 with locking arrangements, applying one coat of red oxide primer and two coats of black bituminous paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50m complete all as specified and directed.
M&L for Construction of masonry valve chamber of size 600 x 600 x 750 mm internal size, 150 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with precast solid block masonry set in cement mortar 1:4, 15MM thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth without using extra cement , 10 SWG thick MS sheet cover including MS angle frame of size 40 x 40 x 6mm fixed in coping PCC 1:2:4, type B1 with locking arrangements, applying one coat of red oxide primer and two coats of black bituminous paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50m complete all as specified and directed.
M & L for cutting existing CI/DI pipe line 150mm dia for insertion if CI/DI Tee size of 150 x 150 x 100 mm and specials complete (for termination of new 100mm dia DI pipe line in existing 150mm dia CI/DI pipe) all as specified and as directed.
EXTERNAL ELECTRIFICATION Supply and laying of Telerex DWC ( Double Wall Corrugated) HDPE pipe ISI marked confirming to IS-14930 Part-II of outer dia of 145mm and inner dia 126mm polythylene with smooth internal and profiled external surface for non pressure under ground cable complete including couplers and fittings all as specified and as directed.
Supply and laying of Telerex DWC ( Double Wall Corrugated) HDPE pipe ISI marked confirming to IS-14930 Part-II of outer dia of 77mm and inner dia 63mm polythylene with smooth internal and profiled external surface for non pressure under ground cable complete including couplers and fittings all as specified and as directed.
Supply and laying of Telerex DWC ( Double Wall Corrugated) HDPE pipe ISI marked confirming to IS-14930 Part-II of outer dia of 50mm and inner dia 38mm polythylene with smooth internal and profiled external surface for non pressure under ground cable complete including couplers and fittings all as specified and as directed.
Taking up and removing of existing cable of size up to 16 sqmm 3.5 /4core by excavation from the trenches, ducts complete all as specified and as directed.
Taking up and removing of existing cable of size from 25 sqmm up to 35 Sqmm 3.5 core by excavation from the trenches, ducts complete all as specified and as directed.
Taking down and removal of existing old LT panel consisting of any capacity 04 Nos bus bars and 02 Nos MCCB, 02 Nos MCB including panel wiring etc and foundation frame complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of earth plate not less than 1.5 m below normal ground level, including provision of galvanized strip 32 x 6mm, earth plate surrounded from all sides by with 15cm thick packed layer of charcoal dust and common salt filling in alternate layer and electrode connection by using galvanized earth wire 4 mm connected by means of bolt ,nut, check nut & washer of galvanised iron, provision of 15 mm dia GI pipe light grade for protection of GI wire & 20mm dia. GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel ,wire gauge, 50mm thick RCC 1:2:4 TMT bars on both ways including necessary excavation in any type of soil returning filling in removal of surplus soil to distance n.exc. 50m complete all as shown in electrical plate no 5 of schedule part-1 2009 all as specified and directed.
Supply, install , test and commissioning of LT feeder pillar box double door type made out of 3.15mm thick CRCA sheet after seven tank process and fixed on angle iron frame by means of suitable nut bolts and clamps cubical type as per IS rules with IP43 protection suitable for 3 phase 4 wire 50 Hz 500 V weather proof vermin proof internal connection with copper cable, chromium plated brass cable gland duly painted with two coats of synthetic enamel paint overa coat of redoxide primer, suitable for and consisting of following ( Panel at Txf Main FP Box for new tapping) INCOMER (a) MCCB 200 Amps, 25 KA 4 pole - 01 No BUS BAR CHAMBER (b) Bus bar aluminium of capacity 400 Amps for 3 Phase, 200 Amps for neutral mounted on epoxy insulator and insulation sleeve OUTGOINS (a) MCCB 160 Amps, 25 KA 4 pole - 01 No (b) MCB 32 Amps, 10 KA 4 pole - 01 No (c) Multifunctional Digital Type Meter 0-200 Amps & 0-500V with CTs 200/5 Amps- 3 Nos - 01 No (d) RYB Phase indicators with control fuses.
Supply, install , test and commissioning of LT feeder pillar box double door type made out of 3.15mm thick CRCA sheet after seven tank process and fixed on angle iron frame by means of suitable nut bolts and clamps cubical type as per IS rules with IP43 protection suitable for 3 phase 4 wire 50 Hz 500 V weather proof vermin proof internal connection with copper cable, chromium plated brass cable gland duly painted with two coats of synthetic enamel paint overa coat of redoxide primer, LT danger notice plate 200mm x 150mm made out of mild steel at least 1.6mm thick & vitreous enamelled white on both sides and with inscription in signal red colour with skull & bone on front side 440V grade suitable for and consisting of following INCOMER (a) MCCB 160 Amps, 25 KA 4 pole - 01 No BUS BAR CHAMBER (b) Bus bar aluminium of capacity 400 Amps for 3 Phase, 200 Amps for neutral mounted on epoxy insulator and insulation sleeve OUTGOINS (a) MCCB 63 Amps, 16 KA 3 pole - 03 No (b) MCB TPN 32 Amps, 10 KA - 01 No (c) Multifunctional Digital Type Meter 0-200 Amps & 0-500V with CTs 200/5 Amps- 3 Nos - 01 No (d) RYB Phase indicators with control fuses.
Supply and erect in true vertical position 6m long mild steel 6mm thickness octagonal poles with single arms bracket of appropriate size for mounting of street light fitting without flanges with all accessories, pole cap, base plate including necessary provisions for housing control gear, fixing with bolt, nuts, washers and including three run of copper cable 1.5 sqmm PVC insulated FRLS of approved colour for phase, neutral and earth from junction box to street light fitting etc and necessary excavation and earth work in any type of soil and including foundation for poles in PCC 1:3:6 type C1 using 20mm grade stone aggregate all as specified and as directed. Make - National pole agency/India Tube Co/ Zindal steel or equivalent make as specified.
Supply and fix street light luminaries LED type 48 W of Endura city liner neo new generation energy saving comprising of epoxy powder coated housing enclosed with glass cover suitable for 35/40mm OD pipe, ingress protection IP66 (Model: SL48WLED757PASYTOPC of Havells or its equivalent from the makes as specified)
SEWAGE DISPOSAL Supply and laying double wall corrugated DWC pipe HDPE pipe of outer Dia 175 mm and inner Dia 147 mm of approved make ISI marked polythene with smooth internal wall & profiles external surface for non pressure for sewage complete all as specified
PILE FOUNDATION Drilling /Boring through any type of soil (loose/soft) upto the depth as directed /indicated for 500 mm outer dia bored cast-in-situ vertical piles duly stabilising the sides by drilling fluids(reverse or DMC Method) or by driving 6 mm thick casing pipe upto loose strata or refusal level or any other approved method and disposal of drilled/bored material to a distance exc 50 m and not exc 100 m all as specified and directed.
Drilling /Boring through any type of soft disintegrated rock/hard rock strata upto the depth as directed /indicated for 500 mm outer dia bored cast-in-situ vertical piles duly stabilising the sides by drilling fluids(reverse or DMC Method) or by driving 6 mm thick casing pipe upto loose strata or refusal level or any other approved method and disposal of drilled/bored material to a distance exc 50 m and not exc 100 m all as specified and directed.
Material and labour 500 mm dia for RCC M-35 design mix for cast -in-situ piles using tremie method up to cutt off level NOTE: (i) Reinforcement shall be measured and paid seperatly under relevent item of schedule XI (ii) The boring of piles shall be commenced from original/made up ground level before carriying out site levelling work .The depth of boring of piles shall be measured from top of original /made up ground level to the approved founding level
Carrying out/ conducting testing piles for initial load test all as per of IS -2911 part IV-9185 for Axial load 48.394Ton, lateral load 11.22 Ton and Pull out load test 22.12 Ton on designed safe load of 24.197Ton,05.61Ton and 11.06Ton respectively on test of 500 mm bore including bringing at site all testing equipment making arrangement for testing and removal of the same after completion and recording the test result and preparing the test sheet complete all as specified and as directed. Note:- Rate including for test pile boring ,concrete and reinforcement for two piles (for lateral load purpose also)
Carrying out/ conducting testing piles for routine load test all as per of IS -2911 part IV-9185 for Axial load 36.30Ton, lateral load 8.415 Ton and Pull out load test 16.59 Ton on designed safe load of 24.197Ton,05.61Ton and 11.06Ton respectively on test of 500 mm bore including bringing at site all testing equipment making arrangement for testing and removal of the same after completion and recording the test result and preparing the test sheet complete all as specified and directed
Carrying out/ conducting standerd penitration test all as per of IS -2911 part IV-9185 in the strata where pile is proposed to be rested /terminated including bringing at site all testing equipment making arrangement for testing and removal of the same after completion and recording the test result and preparing the test sheet for 500 mm dia piles complete all as specified and as directed.
Subtotal
CITY CONSTRUCTION COMPANYU
PRASHANTH ERECTOR AND BUILDERS PVT LTD
SACKSON ENTERPRISES
surendra infrastructure pvt ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid