| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹20.4 L+₹17,004 (0.84%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹22.7 L+₹2.5 L (12.2%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹22.8 L+₹2.5 L (12.5%)Rejected-Finance PULGAON | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹22.9 L+₹2.7 L (13.2%)Rejected-Finance BHAWANI KRUPA GANDHI CHOWK PULGAON | PULGAON | WARDHA | MAHARASHTRA | L5 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
25 Jan 2020, 5:00 pmClosed
GE PULGAON
GE PULGAON
REPAIRS REPLACEMENT OF OLD VINTAGE WIRING AND EARTHING IN DEPOT AREA AT CAD PULGAON
2020_MES_312286_1
8789/PUL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE PULGAON
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE PULGAON
₹40,000
Yes
19 Feb 2020
6 Jan 2020
27 Jan 2020
6 Jan 2020
25 Jan 2020
20 Jan 2020
6 Jan 2020 - 25 Jan 2020
Amount
Taking down carefully conceled / casing caping point wiring copper / aluminum (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling rose, pendents, regulators, sockets light fittings, casing caping / batten / conduit and making good disturbed sufaces wall, floor as per existing surfaces complete all as specified and as directed.
Material and labour for point wiring complete with 1.5 sqmm single core sheathed PVC insulated FRLS cable 1100 V grade multistranded copper conductor of code red for phase, black for neutral and green for earth of ISI marked drawn through and including non metallic rigid PVC Conduit of suitable size with accessories ISI marked concealed in wall/ceiling including PVC insulated copper cable for earth continuity conductor of same type and size and connected to earth dolly including provision of sunken cast iron/pressed steel terminal boxes of suitable size with 3mm thick plastic laminated sheet cover for mounting switches/sockets and regulators complete all as specified and as directed. One light point controlled by one switch one way. Note:- Cutting chases for laying conduct and sunken boxes and making good to walls, floor will be included in the above quoted rates.
All as per item No 2…….. but for One ceiling fan /exhaust fan / wall mounting fan point controlled by one switch one way.
All as per item No 2…….. but for one socket outlet three pin 5/6 amps controlled by one switch on the same board
All as per item No 2…….. but for one socket outlet three pin 5/6 amps controlled by one switch on independent board.
Material and labour for point wiring complete with stranded copper conductor 2.5 sqmm (normal area ) single core , multistranded, FRLS, PVC insulated and unsheathed cable FRLS 1100 volts grade multi stranded for earth . ISI marked drawn in and including PVC casing caping of suitable size with accessories ISI marked including PVC insulated copper cable for earth of same type and size connected to erth dolly including provision of PVC box of suitable size for mounting complete all as specified and as directed. One light point controlled by one switch one way.
Material and labour switch piano type single pole , one way , 5 Amps , 240 Volt complete all as specified and as directed
Supply and fixing socket outlet 5/6 pin type , 5 Amps , 240 volt complete all as specified and as directed
Supply and fixing switch flush type 15/16 Amp complete all as specified and as directed
Supply and fixing socket outlet (Multipurpose type) but 5 Amp/15 Amp flush type complete all as specified and as directed
Supply and fixing ceiling rose surface type 3 terminals including taking down old unserviceable one complete all as specified and as directed
Supply and fixing fan regulator electonic step type AC 240 volts, 50 Hz complete including taking down complete all as specified and as directed
Supply and fixing in repair lamp holder PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed
Supply and fixing LED tube light lamp 1 x 18/20 watt including suitable size of batten complete (01 set) including taking down old unserviceable any type of LT fitting complete all as specified and as directed .
S and F LED lamp 1 x 18/20 watt retrofit in existing tube light fitting batten complete (single / double side connection) including taking down old unserviceable one complete all as specified and as directed.
S and F tube light fitting 1 x 9/10 watt complete set (LED lamp and batten) including taking down old unserviceable any type of TL fitting complete all as specified and as directed.
Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall, ceiling and making good surfaces to match with existing surfaces all as specified and as directed.
M and L sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in PVC Casing caping 20 mm / PVC conduit pipe complete all as specified and as directed. 2 run of 1.5sqmm PVC FRLS copper cable and one run of1.5sqmm PVC FRLS copper cable for earth wire multistranded. Note :- (i) 2 runs of wire and 1 run of earth wire will be measured as one unit. (ii). Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted rate.wiring 2 run of wire and1 run of earth wire
All as per item No 18……… but for 2 run of 2.5sqmm PVC FRLS copper cable and 1run of 2.5sqmm PVC FRLS copper cable for earth wire multistranded
All as per item No 18……… but for 2 run of 4sqmm PVC FRLS copper cable and 1run of 4 sqmm PVC FRLS copper cable for earth wire multistranded
All as per item No 18……… but for 2 run of 6sqmm PVC FRLS copper cable and one run of 6 sqmm PVC FRLS copper cable for earth wire multistranded
S and F in repairs of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 4 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete including. blanking plates as required and making good the disturbed surfaces.
S and F in repairs of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 8 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete including. blanking plates as required and making good the disturbed surfaces.
S and F in repairs of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 12 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete including. blanking plates as required and making good the disturbed surfaces.
S and F in repairs of sheet steel enclosure with Double door flush TPN 4 ways 440 volt factory fitted rated bus bars,earth bar,neutral links complete including blanking plates as required and making good the disturbed surfaces.
S and F in repairs sheet metal enclosure Single pole and neutral 240 V with a two pin and earth plug and socket complete with one single pole MCB of 20 to 32 Amp complete all as specified and as directed.
S and F in repairs sheet metal enclosure Double pole 240 V with a two pin and earth plug and socket complete with two pole MCB of 20 to 32 Amp complete all as specified and as directed.
S and F in replacement of MCB TPN 63 Amps 415V ,50 Hz ,breaking capacity 10 KA," C " series all as directed.
S and F in replacement of MCB SPN 40 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series all as directed.
S and F in replacement of MCB SPN 20 to 32 Amps 240V ,50 Hz, breaking capacity 10 KA," C " series all as directed.
S and F in replacement of MCB SP 6-32 Amps 240V ,50 Hz, breaking capacity 10 KA," C " series all as directed.
Taking down bldg security light of any capacity / size / wattage / make including bracket, nut , bolt washer complete all as specified and as directed.
Supply and Fix to wall / pole of any height LED bldg security light 25 watt IP 65 including GI pipe suitable size bracket not less than 1 metre bend to shape with 2 clamps, nuts, bolts, washers and PVC 3 core ISI mark flexible wire from ceiling rose to fitting complete all as specified and as directed.
S and F in replacement energy efficient LED bulb, B22 9 Watt complete all as specified and as directed.
Supply and fix in replacement of old unservicable MH/HPSV light fitting with LED flame proof light fitting 60 watt IP 65 including fixed to roof or wall of any height with suitable size of nut, bolt and washer etc Note :- Any T&P required at site deemend to included in above rate
M/s MM TRADERS
Paragon Electrotechnics
M/S Maa Durga Constructions,Pulgaon
M/S JAI BHAWANI CONSTRUCTIONS
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
Bidder Name
Paragon Electrotechnics
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
MAHARASHTRA ENTERPRISES
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .