| 1 | L1₹7.5 CrAccepted-AOC | ₹7.5 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹8.4 Cr+₹93.6 L (12.5%)Rejected-AOC NO 9 DR SEVALIYE SHIVAJI GANESAN NAGAR 3RD STREET DINDIGUL 624 001 | DINDIGUL | DINDIGUL | TAMIL NADU | 624001 | ₹8.4 Cr+₹93.6 L (12.5%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹9.4 Cr+₹1.9 Cr (25.2%)Rejected-AOC | ₹9.4 Cr+₹1.9 Cr (25.2%) | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹10.0 Cr+₹2.5 Cr (33.7%)Rejected-AOC | ₹10.0 Cr+₹2.5 Cr (33.7%) | L4 | Rejected-AOC NOT BEING LOWEST |
| 5 | L5₹10.8 Cr+₹3.3 Cr (43.9%)Rejected-AOC NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹10.8 Cr+₹3.3 Cr (43.9%) | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹7.4 Cr
EMD Value
₹7.0 L
Closing Date
10 Nov 2023, 6:00 pmClosed
Chief Engineer Chennai Zone
HQ CE Chennai Zone, ISLAND GROUNDS, ANNA SALAI, CHENNAI 600 009
CONSTRUCTION OF 24 DEFENCE CIVILIAN MARRIED ACCN AT GE DSSC WELLINGTON
2023_MES_612122_2
85172/ E8
Open Tender
Civil Works
Lump-sum
731 days
Wellington
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE DSSC Wellington
₹7.0 L
Yes
12 Jan 2024
6 Sept 2023
13 Nov 2023
6 Sept 2023
10 Nov 2023
27 Oct 2023
Amount
Lumpsum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for PROTECTIVE WORKS as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for ROAD / PATH /CULVERT as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for COMPOUND WALL, FENCING AND GATE as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XII
SCHEDULE 'A' PART XIII (HOT WATER SUPPLY) Note: This schedule is not pre-priced by MES and the pre-priced rate left "BLANK" under column 5 signifies this fact only.
Supply installation and testing Vertical type Storage Electrical water heater (Geysers) of 25 Ltrs Capacity Tank made of ultra thick super cold rolled steel Plates with density PUF insulation 2 KW, 230 V, Single phase 50 Hz AC, BEE 5 Star rated all as per Cat No.GHWCBNTWH025, Model: Bianca DX of Havells or Model: Andrix Lux Plus of make Racold or Model:Compagno of Make Bajaj or techno-commercially equivalent of other specified makes including multifunction safety valve rated pressure > 0.8 MPa, standing loss in KWH/ 24Hr/45 C < 0.511 KWH Tank Warranty > 7 years, Body and Electrical components Warranty > 2 yrs Heating Element Warranty > 4 years with and integrated shock safe plug, 2 Nos. of anchor fasteners of size as per manufacturer instructions grouting, fixing and connecting electrical & water supply connection using steel braided hose 450mm long suitable for Hot & cold water supply -02Nos and making good to the disturbed surfaces etc., complete complete all as specified and as ditrected.
SCHEDULE 'A' PART XIV (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES and the pre-priced rate left "BLANK" under column 5 signifies this fact only.
SITE CLEARANCE
Earth work in rough excavation in all kind of soil by mechanical means (Hydraulic excavator) including getting out and disposal of excavated earth lead upto 50m etc., complete all as specified and as directed.
Earth work in rough excavation in hard rock by mechanical means (Hydraulic excavator) including getting out and disposal of excavated earth lead upto 50m etc., complete all as specified and as directed. Note: Hard rock obatined from excavation shall become the property of contractor and a credit of Rs.1000/- (Rupees one thousand only) per cubic meter on stack measurement after deducting 50% quantity for voids shall be deducted from the payment due to the contractor and Blasting of Hard rock is prohibited.
INTERNAL ELECTRIC SUPPLY
Material and labour for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking (for Phase, Neutral and Earth) in and including non metallic PVC rigid conduit medium grade with ISI mark of size 19mm dia and all accessories concealed in wall / ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including factory made branded modular metal flush boxes concealed in walls and modular white plate covers for mounting of modular switches/ sockets/fan regulators etc complete all as specified for the following:
One light point controlled by 1 No. of modular switch one way.
One light point controlled by 2 Nos. of two way modular switches .
One Exhaust fan point controlled by one modular switch.
One three pin modular switch socket 5/6 Amps outlet on same board.
One three pin modular switch socket 5/6 Amps outlet on independent board.
One Bell point controlled by 1 No. of modular bell push one way.
Material and labour for point wiring complete all as specified with 1100 Volts grade 2.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking (for Phase, Neutral and Earth) in and including non metallic PVC rigid conduit medium grade with ISI mark of size 20mm dia and all accessories concealed in wall / ceiling including continuous earth wire 2.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including factory made branded modular metal flush boxes concealed in walls and modular white plate covers for mounting of modular switch socket 6/16Amps outlet on independent board etc complete all as specified and as directed.
Note for Items No.17.00, 17.01 to 17.06 and 18.00: (i) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. (ii) Cost of cutting chases in wall and making good for concealing conduit/ Metal Flush boxes, MCB DB etc., for point wiring/sub main wiring and cutting opening for fixing exhaust fans and making good the disturbed surfaces are included in the lump sum price of Building under Schedule 'A' Part-I
Supply and Fix Telephone socket , Jack type RJ11 with shutter, 01 module all as per Cat No. 5734 26 of Legrand or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
Supply and Fix TV CO-Axial socket outlet modular type, 01 Module all as per Cat No.5734 25 of Legrand or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
Supply and Fix 20W,120 lumen/watt, wall mounted, ultra slim, polycarbonate, LED lighting fixture, (605 x 66 x 76)mm, 6500K, with high lumen output, environmental friendly, energy efficient with electronic driver complete all as per Cat No. STOUT PLUS600BS20WLED857SPCWH of Havells or BN308CLED40S6500120PSDWH OF Philips or OPTIMA-LL24 of Wipro or techno-commercially equivalent of other specified makes including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture with all fixing arrangement etc., complete all as specified and as directed.
Supply and Fix surface / wall mounted LED light fitting 10W or next higher rating (2 FT), 120 lumen/W, IP 20, CRI > 80, CT > 6500K, THD < 10%PF with extruded aluminium channel housing white coloured & integrated electronic driver (SMPS based constant current supply) with output short-circuit protection, surge protection as per IS:15885 Part 2/Sec 18 with all accessories internaly prewired complete all as per Cat No. LUMILINE+BS10WLED865SPCSS of Havells or BN21LED12S6500PSUGR (Model Smart white) of Philips or LL-20-111-XXX-65 NE3- 2FT (Model Trim NEO/LL20) of Wipro or techno-commercially equivalent of other specified makes including electrical connection with twin/3 core flexible conductor cable of appropriate size with flexible hose from ceiling rose to the fixture complete all as specified and as directed.
Supply, fix, commission & testing of Microprocessor based Single Phase, tamper proof, smart bulk energy meter rating with 2 wire 240 Volts, 50Hz of range 5-60Amps onforming to IS 16444 with DLMS protocol, LED/LCD display with inbuilt Default RF recharge facility & RS 485 Port option, compaitble for GPRS communication with inbuilt disconnection & reconnection, Network topology LONG RANGE RF compatible for smart energy billing system both postpaid and prepaid with optional user based disconnection/reconnection through remote software and data export to MES ERP software facility of load and with overload and over voltage protection Electronic & Mechanical tamper proof including wiring chamber compatible for 2 way communication for
disconnection and reconnection option through Elnet Pro EMS & EBS version 5.1 web based software, by secured user password login, linking of each meter with existing Elnet Software for Electricity charging unit with meters and software with lifetime license all as per Cat NO.PE5121S of Elmeasure or technocommercially equivalent of L&T or Bentec or other specified makes complete all as specified and as directed.
Note for item No.23: (i) Design/ Drawing / BOMT / Technical specifications of the energy meter is to be got obtained from the OEM/ Authorised supplier and the same is to be got approved from the Engineer-in-Charge before placing the final order to OEM/Authorised supplier. (ii) The complete work of installation, commissioning and testing & linking of the energy meter to the existing/new software is to be got done from the OEM/Authorised channel partner only. (iii) Quoted rate is deemed to be inclusive of linking each meter with the centralized electricity charging unit software as specified.
(iv) The meter waranty should be 3 years, service waranty should be 5 years and life time service support. (v) The mete should be able to blink and give buzzer warining to indicte low balance. (vi) There should be an option for friendly credit. (vii) Any rejoining of wires/cables shall be done using suitable ferrule/cable connectors after removal of meter.
Supply, install, testing and commissioning of Outdoor DCU (Outdoor LORA Gateway) for long range communication up to 1KM suitable for communicating with pre-paid cum post paid meter with LORA or any other suitable communication protocol all as per Elmeasure Model : ELM LORA GW or equivalent in L&T or other specified makes and the data transfer to the existing Theiox Software complete all as specified and as directed. Note: The cost of pole/fixing/mounting arrangement on which the accumulator to be installed and SMPS power supply with power backup for minimum up to 2 hours is deemed to be included in the unit rate quoted.
Providing, hosting GPRS charges for 2 years warranty period for communication of meter from cloud based software system through any one of the agency like BSNL/Airtel/JIO/ Vodafone etc., complete all as directed.
Supply, fix, connecting and testing factory made, prewired Vertical type distribution board, (MCCB DB) TPN, 4 way, having degree of protection IP 43 with metal double door, 415 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 250 Amps rated copper bus bar all as per Cat No.DHDLVDRWAOFO04 of Havells or 5077 45 of Legrand or 811893 of Indoasian or techno-commercially equivalent of other specified makes with common neutral link earth bar, din bar for mounting MCBs, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: 4P MCCBs and MCBs will be measured and paid separately.
Supply, fix, connecting and testing factory made, distribution board, (MCB DB) SPN, 12 way, having degree of protection IP 43 with metal double door, 240 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link all as per Cat No.DHDPSHODPW12 of Havells or 5076 12 of Legrand or 811808 of INDOASIAN or techno-commercially equivalent of other specified makes with provision for MCB SPN as incomer and SP MCBs as outgoing and total number of modules equal to 2 + 6, complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCBs will be measured and paid separately.
Supply, fix, connecting and testing factory made, distribution board, (MCB DB) SPN, 4 way, having degree of protection IP 43 with metal double door, 240 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link all as per Cat No.DHDPSHODPW04 of Havells or 5076 10 of Legrand or 811805 of INDOASIAN or techno-commercially equivalent of other specified makes with provision for MCB SPN as incomer and SP MCBs as outgoing and total number of modules equal to 2 + 2, complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCBs will be measured and paid separately.
Supply, fix, connecting and testing MCCB, Four Pole, 63 Amps, 415Volts with breaking capacity 36kA, (lcs=50%lcu) with Fixed Thermal setting, conforms to IEC 60947 - II, suitable for isolation, fixed overload and fixed short circuit settingall as per Cat No.830080 of INDOASIAN or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
Suppy and fix MCB SPN, 240 Volts, C - Series of capacity 06-32 Amps with breaking capacity 10 kA all as per Cat No.4086 09 to 4086 17 of Legrand or Cat No.811144 to 811151 of INDOASIAN or DHMGCSNF006-032 of Havells or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
Suppy and fix MCB SP 6 to 32 Amps, 240 Volts, C curve, 10 kA all as per Cat No.4085 87 to 4085 95 of Legrand or Cat No.AU10s 10(06-32) 3C of L&T or DHMGCSPF006-032 of Havells or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
ROAD/PATH/CULVERT/HARDSTANDING
Material and labour for preparing bituminous surfaces of road and marking centre lines, stop lines, dashes, arrows etc. and the like on roads pavements with hot applied thermo plastic compound 2.5mm thick of white, golden, yellow or black colour as required and confirming to BS 3262-1989 including reflectorising glass bead @ 0.25 Kg/Sqm as per IRC:35(1997) and as per Clause 803 of MORTH specification with special applicator machine fitted with profile shoe, glass beads dispenser propane tank heater and profile shoe heater with heating arrangement up to 160°C, driven by experienced operator all as per manufacturers' instruction etc., complete all as specified and as directed.
Supply and Fix stainless steel sections (square/circular/rectangular section/chains etc.) of first quality with the wall thickness of 16 gauge and of grade 304 including necessary fabrication, drilling, fixed to floor with flat iron clamps at bottom and grouted with cement and shall be covered with Stainless steel shoe etc., complete all as specified and as directed.
SEWAGE DISPOSAL
Supply and lay Double Wall Corrugated High-density polyethylene (SN 8) pipe of nominal size 150mm (ID 148.5mm/ OD 172.5mm) conforming to IS 16098-2013), laid in trenches/floors over concrete bed with and including collars, necessary fittings such as bends, sockets and other connected accessories, sealing of joints etc., complete all as specified and directed.
RAIN WATER HARVESTING
Material and labour for High Yield Srength corrossion resistant TMT steel bars in reinforcement of water retaining structures like UG Sump/static tank, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D (CRS) complete all as specified and as directed.
Material and labour for High Yield Srength corrossion resistant TMT bars in reinforcement of water retaining structures like UG Sump/static tank, 5mm dia and over up to and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D (CRS) all as specified and as directed.
EXTERNAL WATER SUPPLY
Supply, lay and testing of Ductile Iron pipes of size 100mm bore with spigot & socket ends, cast special, class K9 conforming to IS 8329 with inside surface of centrifugally cast cement mortar lined suitable for tyton joint (Push-on joint) in any length laid to level or to falls in trenches/ on grounds / on supports including DI specials as required at site and jointing with flexible push-on type gasket of electrometric (EPDM) joining materials conforming to IS:5382 and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and as directed.
Note for item No.37: (i) Excavation and earthwork, Returning, filling in and removal of soil shall be measured and paid separately under relevant items. (ii) Contractor is responsible for repair/replacement of any damages to the existing structures etc., during the course of execution.
Material and labour for for ductile iron fittings confirming to IS 9523 K-12 suitable for spigot and socket pipe class K-7 such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc., including rubber gasket joints & testing complete all as specified and as directed.
Material and Labour for Construction of valve chamber of internal size 900 x 900 x 900mm including necessary earth work excavation, 100mm thick PCC 1:4:8, type D2 using 40mm graded stone aggregate in foundation with 100mm offset, 200mm thick PCC solid block masonry walls built in CM 1:6, PCC 1:2:4 type B1 for coping, 15mm thick rendering in CM 1:4 for internal surfaces and external plaster up to a depth of 15cm below GL, including provision of 3.15mm thick MS sheet cover, double door, welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys(Godrej/Shell), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any kind of soil /any kind of rcok and disposal of surplus soil/material to a distance not exceeding 50 metre complete all as specified and as directed.
Material and Labour for Construction of valve chamber of internal size 1200 x 1200 x 1200mm including necessary earth work excavation, 100mm thick PCC 1:4:8, type D2 using 40mm graded stone aggregate in foundation with 100mm offset, 200mm thick PCC solid block masonry walls built in CM 1:6, PCC 1:2:4 type B1 for coping, 15mm thick rendering in CM 1:4 for internal surfaces and external plaster up to a depth of 15cm below GL, including provision of 3.15mm thick MS sheet cover, double door, welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys(Godrej/Shell), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any kind of soil /any kind of rcok and disposal of surplus soil/material to a distance not exceeding 50 metre complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY
Supply, fix and testing LED Street light fitting of rating 60 Watts, 6000 Lumens output IP-66 protection including driver unit suitable for working voltage 140-270 V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy powder coated grey colour after phospho chromate treatment with all accessories as per Cat No: ENDURAPEARL NEOSL60WLED757PASYTOPCAST of Make Havells or techno commercially equivalent of other specified make including GI pipe bracket made out of 40mm dia light grade GI pipe of length 1.2 Mtrs, bend to shape 120-130 degree, MS clamps made out of 25x3mm flat iron 3 Nos, nut & bolts for fixing the bracket on the pole and painting with two coats of aluminium paint over one coat of primer and connecting up complete all as specified and directed.
Supply and Fix loop in- loop out junction box, maintenance free, tamper and rot proof, Fire retardant- Class FV-0 as per IS:11731 part-II,termite resistant, IP55 with approx internal dimension 200x 140x 95mm (HxWxD) or next higher size made out of FRP sheet,Cable entry from top-1 No and bottom-2 Nos with weather proof canopy including din rail for mounting Single pole MCB, 20 Amps rated 4 Way connectors for 3 phase and neutral incoming/out going, mounted in the box all as per Cat No: GSJB-2014 of Sintex or techno-commercially equivalent of other specified make including fixing on steel tubular poles with necessary aluminium clamps, suitable double compression cable glands, lugs, GI nut and bolts etc., complete all as specified and directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT control panel board 3 Phase, 4 wire system, 415/440 Volts grade, plinth mounted outdoor type of size 1200 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) with suitable neoprene rubber gasket to make it completely dust & vermin proof, degree of protection not less than IP 65, General consrtuction conforming to IS-13947, double door front and back opening type, sloped canopy (Hood) on top extended 100mm all around provided with ventilation facility in the form of louvers for better heat dissipation, separate compartment
for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating, incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15mm thick CRCA sheet for outer portions, 2.00mm thick CRCA sheet for inner portions, duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded
copper conductor of suitable size, not less than 2.5 Sqmm for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of 50x50x6mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded in PCC 1:2:4, type B1, 45 CM below ground level and 15 CM above ground level over PCC 1:3:6, type C2 foundation including testing and commissioning complete all as specified and directed and consisting the following :- (For Distribution LT Panel of Block 1 to 4 of Type II MD Accn.)
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 200 Amps rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 100-125A all as per Cat No. CM90642OOLO of Make L&T or techno-commercially equivalent of other specified makes - 01 No. OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 32-40 A all as per Cat No.CM91712OOFOOG of Make L&T or techno-commercially equivalent of other specified makes - 05 Nos (4W+1S)
P Natesan and Co
M Mohan Babu
K S MUTHU CONSTRUCTTIONS
Phoenix Infra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .