Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC 8 6TH CROSS MATHRU SHREE NILAYA OPP MAHARISHI RESIDENCE KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹50.0 L+₹32,020 (0.64%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹50.0 L+₹32,338 (0.65%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹50.2 L+₹53,484 (1.08%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹52.9 L+₹3.2 L (6.41%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
16 Sept 2021, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
COMPREHENSIVE MAINT OF EM SERVICE CELL SEWAGE LINE LIFT AND REPAIR MAINTENANCE OF BUILDINGS POST TOP LATTERN LT CABLING WORKS AND OTHER EM WORKS IN VARIOUS DIVISION AT DFRL MYSORE
2021_MES_470802_1
8145
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE I R AND D East Bangalore
D b (i) d (v)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹92,000
Yes
27 Oct 2021
26 Aug 2021
18 Sept 2021
26 Aug 2021
16 Sept 2021
11 Sept 2021
27 Aug 2021 - 1 Sept 2021
Amount
Manning of E/M service cell including attending day to day electrical complaints in DFRL Area, Residential area and MES Office and residential area complete all as specified and directed
(a) Nature of work to be carried out/attended as under:-
(i) Registering and attending all day to day complaints for DFRL Residential area MES Office and MES residential area including street lights and as directed by Engineer-in-Charge.
(ii) Replacement of electrical items such as switches, socket holders, bulb/tubes chokes etc including attending the power failure complaint and rectifying the same.
(iii) Maintenance of complaint register and complaint slip
(iv) Repairing of street light/boundary light as and when reqd in DFRL tech area, residential area and MES complex complete all as directed.
(v) Pruning of trees obstructing LT distribution line in DFRL residential area as and when required.
(vii) Rate quoted shall include for replacement of worn out / blown HT DO fuses as and when required on 4 pole structure in Tech area
(vii) Rate quoted shall include for printing necessary complaint register and complaint slip.
Note:- (i) All stores required to carryout the work will be supplied by the department.
(ii) Tools required for electrician and cutting tools for pruning trees shall be provided by the contractor.
(iii) Aluminium ladder for repairing street light shall be provided by the contractor.
(iv) The cost of providing additional labours to carry mobile type step ladders and repairs of street light and pruning trees once in a week is deemed to have been included in the rate quoted.
Shift timing: 0600 Hrs to 1400 hrs- 01 No Electrician and 01 No Helper 1400 Hrs to 2200 HRS-01 No Electrician and 01 No Helper
Maintenance of external sewage lines, manholes, gully traps and removal of waste materials etc at DFRL as under:-
(a) Clearing blockages in external sewage lines between bldgs and manholes and manholes to manholes etc as required and as directed by the Engineer-in-charge.
(b) Checking all manholes once in a week and attending the overflow complaint noticed if any.
© Clearing blockage and removal of waste materials from gully traps, connecting first manholes and sewage lines all as directed.
(d) Clearing of grass shrubs surrounding the manholes and sewage lines periodically and placing the manholes cover in position including cleaning of building roof surfaces twice during the contract period all as directed.
(e) Clearing the blockages in Nahani traps, IWC,s EWS,s WHB,s urinals to the vertical stack pipe lines etc by opening the nahani trap cover cleaning eyes of the cast iron pipes PVC pipes etc including rodding etc. as required and refixing of CI/PVC grating and cover to match with existing surfaces etc. complete all as directed.
(f) The Cleaning of man holes, sewage lines, septic tanks etc will be done in accordance with the provision of employment as manual scavengers and their rehabilitation act 2013.
Minimum number of labour required:-
Sweeper/scavanger-02 Nos per day during general shift of eight hours duration 0800 to 1700 hours including one hour lunch break.
Providing services for operation of passenger/goods lift Capacity 544 Kg/8 person capacity 01 no on all days except Sunday and holidays and including daily maintenance of lift Make: KONE ,all as specified and as directed by Engineer in Charge. Minimum no of Labour Required: Operator 01 No per day during general shift of eight hours duration 0800 to 1700 Hrs including one hour lunch break.
Supply and fixing in replacement suspended linear in sleck design is suitable for all commerical spaces capacity 36 watts, 4 feet Cat No LCLP54-36-CDL Make Crompton Greaves
Supply and fixing in replacement TERRAIN Post top lanteen is a water proof indirect lighting solution having inproved. Horizontal unformity,with reduced glare and improved lighting contist 40 watts Cat No LPTC-40-COL Make Crompton Greaves
Supply and fixing in replacement SUPRA NEO 1 well glass in PDC Aluminium Housing with finless desgin and excellent thumal Mangemennt affering high duralility and superior peformance with energy saving and having efficacy of 110/LM/W Ingress protection of 1P.66 40 walts Cat No LWV12-40 CDL Make Cropton Greaves.
Supply and fixing in replacementn Replacement Neptune ultra- 11 high Eifficacy under canopy which consumes lesser Energy and maintains high lighting levels. Luminaire efficacy of 125 LM/Watt 1P66 80 watts Cat No LCNP-80-CD60HPM Make Crompton Greaves.
Supply and fix in repair Moulded Case Circuit Breakers for Distribution Network with thermal magnetic release type DPX 250 4 pole 100 Amps capacity 25 KA rupturing capacity in existing panel board including modification on existing panel if required, necessary connectioning with copper strips/suitable size of copper conductor wire from bus bar, provison of suitable size of copper lugs as per the out going cable including taking down unserviceable MCCB complete all as directed Make : L & T / ABB / Schneider / Legrand/ Strandard
Supply and fix in repair Moulded Case Circuit Breakers for Distribution Network with thermal magnetic release type DPX250 4 pole 63Amps capacity 25 KA rupturing capacity in existing panel board including modification on existing panel if required, necessary connectioning with copper strips/suitable size of copper conductor wire from bus bar, provison of suitable size of copper lugs as per the out going cable including taking down unserviceable MCCB complete all as directed Make :L & T / ABB / Schneider / Legrand/ STRANDAD
Supply and fix in repair Moulded Case Circuit Breakers for Distribution Network With d shine thermal magnetic release type DPX-250 4 pole 125 Amps capacity 25 KA rupturing capacity in existing panel board including modification on existing panel if required, necessary connectioning with copper strips/suitable size of copper conductor wire from bus bar, provison of suitable size of copper lugs as per the out going cable including taking down unserviceable MCCB complete all as directed Make :L & T / ABB / Schneider / Legrand/strandad
Supply and fix in repair Moulded Case Circuit Breakers for Distribution Network With d shine thermal magnetic release type DPX-250 4 pole 250 Amps capacity 25 KA rupturing capacity in existing panel board including modification on existing panel if required, necessary connectioning with copper strips/suitable size of copper conductor wire from bus bar, provison of suitable size of copper lugs as per the out going cable including taking down unserviceable MCCB complete all as directed Make :L & T / ABB / Schneider / Legrand/Strandad
Supply, laying and testing cable XLPE insulated, screened,pvc bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor 0f size 95 sqmm 3 1/2 Core including gland and lugs for incoming and outgoing cables.
Supply, laying and testing cable XLPE insulated, screened,pvc bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor 0f size 25 sqmm 4 Core.including gland and lugs for incoming and outgoing cables.
Supply, laying and testing cable XLPE insulated, screened,pvc bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor 0f size 10 sqmm 4 Core.including gland and lugs for incoming and outgoing cables.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in hard / dense soil all as directed by Engs-in -charge.
Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting point all as directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified all as directed by Engs-in -charge.
Supply and spread dry river sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming all as specified and directed.
Supply and lay burnt brick sub class 'B' of standard size laid in trenches for cable protection all as specified and directed.
Supply and fix analog time switch 250 volts single phase 20 amps rating with contractor fittings inside steel enclosure. Make L&T
S & F on load change over switch 415 volts in sheet metal encloser of thickness 2.5 mm ,4 pole of capacity 400 Amps.
S & F on load change over switch 415 volts in sheet metal encloser of thickness 2.5 mm ,4 pole of capacity 160 Amps.
Supply and fixing in replacement of Push button switch for LT panel board
Supply and fixing in replacement of Digital Panel meter for Amps, Voltsand WH ,Power Factor and other parament flush mounting of size 96x96 mm
Supply and fixing in replacement of Voit meter 0-500 V flush mounting of size 96x96 mm
Supply and fixing in replacement of Ammeter 0-400 Amps flush mounting of size 96x96 mm
Taking down carefully existing copper / aluminium point wiring (Concealed / surface) light/fan, socket or power complete including fittings and fixtures such as switches sockets ceiling roses pendants regulators light fittings etc removing to store for safe custody or for taking credit and making good disturbed surfaces to match with the existing surfaces complete all as specified and as directed.
Material and labour for point wiring wih PVC insulated copper stranded FRLS conductor single core cable of 1.5 sqmm size drawn throug rigid non metalic PVC conduit fixed on wall/ceiling with replacement of existing steel metal boxes with new modular metal flush boxes modular white cover plate with frame for mounting of modular switches/socket regulator and including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continious contuinity conductor and connected to earth dolly for followings
(a) one light point controlled by one 6 amps switch
(b) one Fan/Exhaust point controlled by one 6 amps switch
(c) one three pin 5Amps sockets outlets on the same board
(d) one three pin 5Amps sockets outlets on the Independent board
All as per item No 31 here-in-before but for one socket out let , 2 in I 5 and 15 Amps with 4 Sqmm PVC Copper conductor and Prrovn of 2.5 sqmm PVC insulated single core copper cable green incolour as earth dolly continuity conductor
Supply and fix modular switch 1 way 6A 230 Volts single pole one way complete all as specified and as directed.
Supply and fix modular switch 1 way 16A 230 Volts single pole one way complete all as specified and as directed.
Supply and fix modular socketoutlets 6A 230 Volts 2/3 Pin complete all as specified and as directed.
Supply and fix modular socketoutlets 16A 230 Volts 2/3 Pin complete all as specified and as directed.
Supply and fix modular Fan Regulators electronic 120W complete all as specified and as directed.
M&L Aluminium strip 25x3.15 MM with saddles and fixing screws etc for roof condutors and down conductors above ground
M&L Air termination single pointed aluminium rod 12mm dia and 300 mm long
M&L test terminals block made of gun metal or phosphorous bronze size 75x75x25MM drilled and srewed incl 3 nos 8mm dia 25MM long Hex head screw
Supply and fixing MS Box of size 150mmx100mm and 75mm deep with door and locking arrangement made out of2mm thick CRCA Sheet duly painted with one coat of rex oxide primer and two coats of synthetic enemelled paint for housing test termina block
supply and fixing Epoxy insulators of suitable size under the aluminium strip at roof/on wall
M&L GI strip 32x6MM on Wall/Burried in Ground
RAMESH BABU CO
ANAND REFRIGERATION
Mandhara Associates
Lucky Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .