| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.6 LAccepted-AOC 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹87.6 L Quoted ₹87.8 L | L1 | Accepted-AOC BEING LOWEST REASONABLE BIDDER |
| 2 | L2₹89.9 L+₹2.2 L (2.46%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | ₹89.9 L+₹2.2 L (2.46%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹97.3 L+₹9.5 L (10.9%)Rejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | ₹97.3 L+₹9.5 L (10.9%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹1.0 Cr+₹12.5 L (14.3%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | ₹1.0 Cr+₹12.5 L (14.3%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S SHIVA TRADERS L2 | Vijaypower Generators Limited L1 | Roy and Sons Infrastructures L3 | Sachdeva Enterprises L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing old Extg unserviceable LT UG/service cable of any description and size complete all as specified and as directed. | 200 | RM | 20 ₹4,000 Lowest | 90 ₹18,000 | 30 ₹6,000 | 20 ₹4,000 Lowest |
| 2.00 | Supplied, laying & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with staranded aluminium conductor, 11000 volts, grade, of size 3 Core 95 Sq mm complete all as specified & directed. | 100 | RM | 1,200 ₹1,20,000 | 1,422 ₹1,42,200 | 960 ₹96,000 Lowest | 1,100 ₹1,10,000 |
| 3.00 | Supplied, laying & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with staranded aluminium conductor, of size 3.50 core 150 Sq mm complete all as specified & directed. | 100 | RM | 1,200 ₹1,20,000 | 1,302 ₹1,30,200 | 862 ₹86,200 Lowest | 1,100 ₹1,10,000 |
| 4.00 | S&F cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete all as specified & directed. | 3 | Each | 15,000 ₹45,000 | 16,500 ₹49,500 | 9,000 ₹27,000 Lowest | 12,000 ₹36,000 |
| 5.00 | Supply install , testing and commisioning of Compact Sub – Station (CSS) comprising 11KV, 630 Amp LBS, 200 KVA Copper Wound Oil Cooled Off-Circuit
Transformer & LT Panel
HT Section :- 11KV, 630A, Indoor Type 26.3 KA Load Break Switch (LBS) with fuse trip, earth switch, dynamic MIMIC arrangement, 230 V AC shunt trip coil and 2no+2nc aux. contacts - 01 No 11Kv HTHRC Fuses Rating: 50A - 03 Nos Indication Lamps - 3 Nos.
LBS off / On Indication Transformer Section :- 200 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down “BIS Marked” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position
Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box
Transformer as per IS-1180:2014 EEL- 2 with amendment no.- 4
Formerly EEL- 3 (till 30.3.2022)
Losses @50% Load - 670W
Losses @100% Load - 2100W | 3 | Each | 28,50,000 ₹85,50,000 | 27,42,000 ₹82,26,000 Lowest | 31,00,000 ₹93,00,000 | 32,00,000 ₹96,00,000 |
| 5.01LT Section :- LT Panel comprising of following switchgear on LV Side; Incomer - 01 no.- 320A 4P 415V 25KA MCCB with thermal magnetic based release with O/L & S/C protection. - RYB Indication Lamp,Ammeter -320A/5A LTCT Cl:1.0 -Voltmeter APFC Section :- 60kVAR APFC Panel having main incomer 200 A MCCB, min. 8 stage APFC relay, capacitor bank (1x20 kVAR + 3x10 kVAR + 2x5 kVAR) with suitable MCB/MCCB & capacitor duty contactors. | |||||||
| 5.02Enclosure :-Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control - 01 set MS Steel Sheet enclosure (2.0 mm) suitable for Outdoor Installation with MS base channel through Bus bar to Trf panel, Excluding Termination Kit & Glands 01 set Provision for receiving Incoming through bus duct by bus bar and Outgoing thro cable box bottom entry Excluding Termination Kit & Glands Bus Bar – Aluminum - 01 set Earth Bus – Aluminum - 01 set Paint shade: Grey ( RAL 7032) - 01 set, | |||||||
| 5.03Notes: (a) The rate quoted is deemed to be including the cost of Erection, Commissioning of Compact Substation and Civil work such as Construction of foundation with Concrete / Brick masonry with plastering for the installation of Compact Substation of required size including trench for the cabling work etc. complete in all respect as directed by the GE. However the bidder shall furnish the foundation details for approval of GE before executing the work. [b] Compact Substation shall be complete with the internal interconnections Copper Busbar & GI Earthing on HT side and Aluminium Busbar on LT side and Aluminium Earthing for complete PSS including TF Neutral for connecting to the earth pits. | |||||||
| 5.04[c] The bidder shall assemble the Compact substation at factory and no assembly of the same shall be allowed at site. Bidder shall be responsible for Installation & commissioning Compact substation. Technical data sheet of the Transformer, HV / LV Switchgear, Relay etc. shall be submitted to GE for approval before placing the supply order. [d] All testing shall be conducted as per IS -2026 [e] The bidder shall supply suitable & required no. of HT & LT Cable termination kits along with Compact Substation for HT & LT Cable terminations. [f] The Design for Internal Arc Fault shall be tested for 20KA for 1 Second as per IEC 1330/62271-202. [g] Pre-Dispatch Inspection: Bidder shall offer for pre-dispatch inspection at OEM works. Only after the equipments are cleared by the department in writing, the bidder can dispatch the equipment. Routine tests shall be conducted and original test certificates shall be submitted at the time of Pre-Dispatch Inspection. [h] Suppressors or other protection devices shall be provided, if required as per schedule of quantities, wherever the sub-station installation is likely to interfere during the operation with any other electric or electronic equipment. | |||||||
| 5.05(j) Construction of plinth for CSS : Excavation of pit of size suitable for CSS with Minimum height of 1000mm, filling with sand for 150mm depth, laying bed concrete with CC(1:4:8) Using 40mm HBG metal for 150mm, construction of plinth as per drawing (2 supports) with RR Masanory of size 0.837 cum and plastering all around the outer side with CM(1:5) 12 mm Thick and White washing 2 coats including cost and transport of all material and labour charges for all operation incidental charges etc, completes directed by the Engineer in Charge | |||||||
Tender Value
₹99.2 L
EMD Value
₹1.7 L
Closing Date
2 Jun 2026, 6:00 pmClosed
CWE JABALPUR
HQ COMMANDER WORKS ENGINEER, SUPPLY MARG, P B NO. 54, JABALPUR - 482001
SPECIAL REPAIR/REPLACEMENT OF 03 X DISTRIBUTION TRANSFORMER AGAINST BER OF ZONE B WITH COMPACT SUBSTATION UNDER GE (EAST) JABALPUR
2026_MES_763288_1
82756/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JABALPUR
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (EAST) JABALPUR
₹1.7 L
Yes
10 Sept 2026
4 May 2026
9 Jun 2026
4 May 2026
2 Jun 2026
26 May 2026
4 May 2026 - 25 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down existing old Extg unserviceable LT UG/service cable of any description and size complete all as specified and as directed. | 200 | RM | - | - |
| 2 | Supplied, laying & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with staranded aluminium conductor, 11000 volts, grade, of size 3 Core 95 Sq mm complete all as specified & directed. | 100 | RM | - | - |
| 3 | Supplied, laying & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with staranded aluminium conductor, of size 3.50 core 150 Sq mm complete all as specified & directed. | 100 | RM | - | - |
| 4 | S&F cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete all as specified & directed. | 3 | Each | - | - |
| 5 | Supply install , testing and commisioning of Compact Sub – Station (CSS) comprising 11KV, 630 Amp LBS, 200 KVA Copper Wound Oil Cooled Off-Circuit
Transformer & LT Pane l
HT Section :- 11KV, 630A, Indoor Type 26.3 KA Load Break Switch
(LBS) with fuse trip, earth switch, dynamic MIMIC arrangement, 230 V AC shunt trip coil and 2no+2nc aux. contacts - 01 No 11Kv HTHRC Fuses Rating: 50A - 03 Nos Indication Lamps - 3 Nos.
LBS off / On Indication Transformer Section :- 200 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down “BIS Marked” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position
Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box
Transformer as per IS-1180:2014 EEL- 2 with amendment no.- 4
Formerly EEL- 3 (till 30.3.2022)
Losses @50% Load - 670W
Losses @100% Load - 2100W | 3 | Each | - | - |
| 5.01 | LT Section :- LT Panel comprising of following switchgear on LV Side;
Incomer - 01 no.- 320A 4P 415V 25KA MCCB with thermal magnetic based release with O/L & S/C protection. - RYB Indication Lamp,Ammeter -320A/5A LTCT Cl:1.0 -Voltmeter APFC Section :- 60kVAR APFC Panel having main incomer 200 A MCCB, min. 8 stage APFC relay, capacitor bank (1x20 kVAR + 3x10 kVAR + 2x5 kVAR) with suitable MCB/MCCB & capacitor duty contactors. | - | - | - | - |
| 5.02 | Enclosure :-Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket,
LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control - 01 set
MS Steel Sheet enclosure (2.0 mm) suitable for Outdoor Installation with MS base
channel through Bus bar to Trf panel, Excluding Termination Kit & Glands 01 set Provision for receiving Incoming through bus duct by bus bar and Outgoing thro
cable box bottom entry Excluding Termination Kit & Glands
Bus Bar – Aluminum - 01 set
Earth Bus – Aluminum - 01 set
Paint shade: Grey ( RAL 7032) - 01 set, | - | - | - | - |
| 6 | M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 mtrs as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR par - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for LT Panels).
Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor. | 18 | Each | - | - |
| 7 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed. | 27 | Per Cum | - | - |
| 8 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. | 17.82 | Per Cum | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.63 MB
TENDER_82756.pdf
Tender Documents • 2.13 MB
BOQ_854974.xls
BOQ • 0.30 MB
Corr_8.pdf
PDF • 0.27 MB
CorrD_7.pdf
PDF • 0.27 MB
Corr_6.pdf
PDF • 0.27 MB
CorrD_5.pdf
PDF • 0.27 MB
CorrD_3.pdf
PDF • 0.32 MB
CorrD_2.pdf
PDF • 0.32 MB
CorrigendumD82756.pdf
PDF • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .