Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.2 LAccepted-AOC | 1 | Accepted-AOC 1 | |
| 2 | 2₹6.0 L+₹76,455 (14.7%)Rejected-AOC BEHIND ANAJ MANDI SHASTRI NAGAR GALI NO 4 BHIWANI 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | 2 | Rejected-AOC 2 | |
| 3 | 3₹6.4 L+₹1.2 L (22.4%)Rejected-AOC | 3 | Rejected-AOC 3 | |
| 4 | 4₹6.6 L+₹1.4 L (27.1%)Rejected-AOC | 4 | Rejected-AOC 4 |
Tender Value
₹7.7 L
EMD Value
₹16,000
Closing Date
11 Jun 2020, 5:00 pmClosed
Vishal Garg
O/o EE5
Drilling, Boring and installation of 01 No Tube well with (DTH) at Village Wazirabad Dhani Ward No. 31 under MCG.
2020_HRY_130565_1
EE-V/MCG/2020/15231 Dt.03.06.2020
Open Tender
Civil Works
Works
60 days
work
EMD TENDER FEE ENLISTMENT
2 documents required · 2 mandatory
₹1,000
Commissioner, MCG
₹16,000
25 Feb 2022
3 Jun 2020
12 Jun 2020
3 Jun 2020
11 Jun 2020
3 Jun 2020
Amount
Drilling, Boring and installation of 01 No Tube well with (DTH) at Village Wazirabad Dhani Ward No. 31 under MCG.
Drilling of 300mm dia bore by DTH Machine or other suitable machine as per ISI specification No.2800-1991 (Part-I) as amended upto date and modified to extent of the specification attached with this schedule of items of work in all kinds of soils and boulders upto 125mm dia except rocky strata including the cost of all consumable stores, fuel, oil, soil stabilizing material and transportation of rig and other accessories to the site proposed bore and back (including cost of lowering of all sizes of casing pipe while boring and extracting the same against earth frictions etc.) Compete to the satisfaction of the Engineer-in-Charge.
Supplying and lowering 219.10mm outer dia ERW steel plain pipes as per IS 4270-1992 as amended pipe in 4 to 7meters random length with 88.90mm of threaded ends(8 threads to an inch or 25.40mm) manufactured out of 6.35mm thick M.S. plates with required number of M.S. socket 152.40mm length with inside thread to match the pipe threads and made out of M.S. plate in to borehole in vertical position including cost of all scaffolding, derricks, Jim, poles, tools and plants, ropes, gays M.S. clamp embedded in foundation etc. complete in all respects to the satisfaction of the Engineer-in charge 90x1=90mtr
Supply and lowering slotted pipe of size 219.10mm outer dia, ERW conforming to IS 3589-1991 (With latest amended) duly ISI marked made out of the 6.35mm thick steel sheet in rembom length of 4 to 7 mtr inside and outside coated with anticorrosive black mastic paint with butt-joint as per IS 3589-1991 (With latest amended) including cost of cutting, jointing, welding lowering in bore hole in vertical position including cost of all T&P accessories required for the job as per site condition complete in all respect. up to a depth of 0 to 60mtr depth BGLX1= 30x1=600mtr
Supplying & packing graded gravel of size as per ISI 4097/1988, as amended upto date and specification attached with this schedule of item of work. The gravel should be free from dust, dirt or vegetable matters. Packing to be done from the housing pipe to the bottom of liner all around on the bore and will be placed other liner and housing pipes have been lowered and suitably clamped. Thickness and size of the gravel packing will be as directed by the Engineer-in-charge 6x1=6cum
Supplying and fixing well threaded M.S. cap for 273.10mm outer dia M.S. pipe as per ISI 226/1975 as amended upto date to the satisfaction of the Engineer-in-charge. 1x1=01 Nos
Supplying and fixing 219.10 mm M.S. clamp as per IS : 226/ 1975 as amended up to date for supporting the housing pipe supported on two girders not less than 100mm x 150mm and two meters long each embedded in suitable foundation as approved by the Engineer-in-Charge. 1x1=01 Nos
Supplying, erection testing and commissioning of submersible pumping sets as per BIS Specification No.8034-1989 (as amended upto date for pumps) and IS. 9283-1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having Characteristics as specified in Clause-4 of IS. 8034/1989 and Clause 4.1 of IS 9283/1979. 230 LPM/ 135 M. Head (10 H.P- 18 Stage ) -For T/Well B.S Make, CRI, Texmo, KSB Etc. 1x1=01 Nos
Supplying erection, testing of electric control panel board for T/wells in pump chamber consisting of MS sheet of thickness 18 gauge duly painted box type floor mounted made of Angle frame containing 1 Nos. fully automatic air brake Starter 15 HP , Main switch of suitable range with HRC fuse, 1 No. Volt meter (0 to 500 Volts), 1 No. Amp. Meter of 0 to 32 Amp. , 3 sets of indicating lamp, Capacitor of suitable capacity & 1 No. single phase preventers with the timer switch including wiring in panel board & suitable Electric energy meter wiring from to Electric control panel board complete in all respect as per Specification given in Schedule No. I. 1x1=01 Nos
Supplying and fixing following C.I. D/F pipe, CI specials, sluice valves with wheel, non return valves with G.M. Flap including cost of jointing materials, excavation, laying refilling including making adequate supports of masonry/concrete/steel for delivery pipe from submersible pump set up to 1.5 meter outside the outer wall of pump chamber as per plan shown as per specification given in Schedule No-II. A) Detail of pipe and specials a) CI D/F bends reducers, tapers, tees, tail piece, and blank flange. 80mm dia 30x1=30Kg
b) GI/DF pipe 80mm dia 1x2.75=2.75mtr
Providing and fixing 16mm 3 core PVC aluminum cable 1x60=60mtr
Bidder Name
Amount
RNK Infra Private Limited(GSTN-NA)
Virender Singh(GSTN-NA)
Sunil Kumar Contractor(GSTN-NA)
Vikas Contractor(GSTN-NA)
Sunil Kumar Contractor
Virender Singh
RNK Infra Private Limited
Sunil Kumar Contractor
Virender Singh
RNK Infra Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .