Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.6 L+₹2.3 L (6.27%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.5 L+₹3.2 L (8.78%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest | |
| 4 | L3₹41.7 L+₹5.4 L (14.8%)Rejected-Finance FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹41.0 L
EMD Value
₹82,000
Closing Date
16 Nov 2022, 6:00 pmClosed
GE NORTH DELHI CANTT-10
GE NORTH DELHI CANTT-10
REPAIR MAINT OF EXTERNAL ELECTRIC SUPPLY SYSTEM INCL STREET SECURITY LIGHTS WITH CONNECTED ITEMS WORKS AND REPAIR MAINT OF EXTERNAL WATER SUPPLY SERVICES INCL REPAIR REPLACEMENT OF UNSV PIPE LINES VALVES VARIOUS MOTOR PUMP SETS CLEANING OF SUMPS A
2022_MES_558564_1
GE/NORTH-44/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE NORTH DELHI CANTT-10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT-10
₹82,000
Yes
22 Dec 2022
19 Oct 2022
18 Nov 2022
19 Oct 2022
16 Nov 2022
2 Nov 2022
Amount
M&L for painting of steel tubular poles 9 mtr to 11 mtr length with applying two coats of aluminium paint including cross arms and clamps except embedded portion of pole in ground and concrete after removing old painted surfaces by scraping of poles complete and two coat for making colour band/strip 30 CM with synthetic enamel paint of approved/yellow & black colour up to 1.2 mtr from coping level including numbering of poles complete all as directed
M&L for painting of RCC poles 8.5 mtr to 11 mtr long with two coat of cement based paint and two coat of synthetic enamelled paint in yellow & black stip 30cm up to 1.5 mtr above the ground level including preparation of surfaces complete and painting of connected cross arms, clamps with aluminium paint all as specified and directed.
M&L for spray painting of old/existing LT panel/feeder piller box any size/type with powder coated paint withsmoke grey paint in outer/inner side of complete panel after cleaning and preparing surface complete all as specified & directed
M&L for repair/overhauling of old LT panel board of any size/type incl cleaning with compressed air, tightening of all electric connections to bus bar & switchgears, re-fixing of door (front & backside) with proper fixing & locking arrangement, replacement of wornout lugs, nut, bolts, proper connection to main earth lead, glands to be provided/replaced as required at cable entries, fixing of door front & back side with proper locking arrangement, repair to PCC foundation as required at site and spray painting with powder coated paint with smoke grey paint in outer/inner side of panel after cleaning andpreparing surface incl sign writing complete all as specified and directed
Dismantling & taking out HT/LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/ in trenches/ along pole/ panel/ feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all as specified and directed
Dismantling & taking out defective LT PVC/XLPE cable from trenches including excavation and earth work, cutting and removing defective parts and supply and fixing straight through joint heat shrink kit complete including jointing material and making connection of LT cables for the following sizes :-
25 sqmm 3.5 core to 50 sqmm, 3.5 core
70 sqmm 3.5 core to 95 sqmm, 3.5 core
120 sqmm 3.5 core to 240 sqmm 3.5 core
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out in loose/soft soil for laying of cable complete all as specified & directed
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed
Sub class ‘B bricks, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and as directed
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
M&L for boring/ making hole under road by drilling machine or hand drill without damaging of road for laying U/G cable for size 40/50/80 mm bore of GI pipe complete all as specified & directed
M&L (in replacement) for GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete for following sizes :-
40 mm bore
50 mm bore
80 mm bore
Cutting/pruning of tree branches along/around over head line at places within a radius of 2 mtr from fasted conductor and removing from site complete all as directed
Servicing & overhauling of Air Circuit Breaker (ACB) of any capacity by taking out from existing LT panel, cleaning all parts internally and externally, checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contact, floating contacts, servicing of motor & charging system incl replacement of faulty parts/spares and re-fixing it on its original position and testing complete all as directed
Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size (Note :- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately) :-
10 Sqmm 2 core
16 Sqmm 4 core
35 Sqmm 4 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
300 sqmm 3.5 core
S&F in repair of 1100 volt grade, heavy duty cable PVC insulated aluminium stranded conductor, size 10 sqmm twin core flat or circular, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended complete all as directed
Checking all incoming & outgoing connections and Mechanism, cleaning, servicing, overhauling, testing it for proper tripping system complete of 11 KV VCB of of Make Crompton Greaves, installed at sub-station bldg, Inspecting, servicing and testing all the connections of control wiring availability of proper DC supply and AC supply, cleaning of contacts, & terminals, using the blower for dusting, servicing of gears, including replacement of faulty control fuses, faulty wiring & faulty indication lamp, checking & closing of tripping system, taking out relay (over current relay and earth fault relay) from the 11 KV VCB and calibrating the relay and proper setting of relay and refixing back in existing position & testing for proper tripping/functioning system complete all as specified & directed (Note : Necessary certificate for calibration of relay with setting detail shall be submitted by the contractor)
Disconnection of all electric connection & taking out old/ defective/ unsv Current Transformer (CT) from 11 KV VCB panel and Supply, fixing, installation & testing of Current transformer, indoor, comprising of 3 Nos single phase resin cast CTs of 100-50/5+5 amps ratio, Class 5P-10 with suitable VA burden and accuracy suitable for protection & metering incl making suitable arrangement for fixing in existing VCB panel and connection incl disconnection & taking out old/faulty current transformers (CTs) from 11 KV VCB panel complete all as specified & directed (Make-ABB/Crompton/Schneider/Siemens/Pactil/AE)
Disconnection of all electric connection and taking down defective/unsv 11 KV PT and Supply, fixing, installation & testing of Potential transformer (PT) 3 phase, dry and draw out type 11 KV/110 Volt, with suitable VA burden per phase, accuracy class 1.0 complete with HT & LT HRC fuses for primary & secondary in VCB complete all as specified & directed (Make-ABB/Crompton/Schneider/Siemens/Pactil/AE)
S&F in repair heater, 230 Volt, as per existing wattage suitable for 11 KV HT VCB panel including electric connection complete all as specified & directed (Make - As per sample) Note for item No. 17 to 21 :- (i) All the instruments and T&P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (ii) The all above checking, inspection, installation & testing work shall be performed by HT expert/engineer.
M&L for on line Dehydration of HV/EHV grade transformer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 50 to 60 KV breaking capacity by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as directed Note- (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arranged by the contractor. (ii) Oil required for topping up the transformer will be measured & paid separately
M&L in replacement of Silica Gel (Blue colour) in breather of transformer after cleaning of breather complete
M&L in replacement of breather of transformer of any make/capacity upto 400 KVA with exising size complete
Supply & filling new transformer oil of having dielectric strenght 60 KV to top up level complete all as specified and directed (Make- Savita/apar/Powerlink/Powerzone/HP/arihant//zebron/apolo/indotech)
S&F in repair LT Porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 400 KVA complete
S&F in repair HT 11 KV porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 400 KVA complete
M&L (in repair) cable jointing kit for 11 KV cable for end termination heat shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size:-
Size 70 sqmm to 120 sqmm, Indoor type
Size 70 sqmm to 120 sqmm, outdoor type
M&L (in repair) cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified & directed of size Size 70 sqmm to 95 sqmm
Supply & laying in trenches/through pipes/ducts or on poles XLPE armoured cable of following sizes with aluminum conductor, 11 KV `E’ complete all as specified & directed of follwing sizes Note :-Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately
95 Sqmm 3 core
120 Sqmm 3 core
S&F hand charging handle rod suitable for existing 11 KV VCB of make Crompton Greaves complete all as specofied & directed
Checking & locating of fault in underground HT/LT cable of any size by cable fault locator machine complete all as directed
Taking out and repairing/overhauling of 11 KV air break gang operated switch tripple pole, mechanically operated mounted on insulators and steel frame installed vertically / horizontally, repairing defective copper strap, knife rod, movable post, insulator 200 amps capcity, ON/OFF handle, replacement of broken/worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after repair complete all as directed
Supply, installation, testing & commissioning (in replacement) of Gang operated air break switch with drop out fuse unit complete with 12 insulator set, HT 11 KV triple pole, 200 amps current rating complete with drop out fibre glass tube fuse, mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore medium grade GI pipe of suitable length with locking arrengment, flat iron clamp 50mm x 6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers incl jumper connection with copper flexible designed jumper complete all as specified and directed
Supply, installation and connecting to electrical system, LT distribution switch board panel cubical type for out door use, double door, with rigid hinges, door handles locking arrangement back side openable, compartmentalized design, mounted on suitable PCC blocks, fabricated out of CRCA sheet 3 mm thick, suitably spaced, totally enclosed in chamber for reception of 3 phase, 440 V, 50 HZ, AC supply including all connection with aluminum strips, internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire with lugs. Panel shall be effectively PVC gasketed and sealed, glands to be provided at cable entries, powder coated painting and sign writing for in/out going connections all as specified & directed and comprising of following as under Note :- (i) All incoming and outgoing cables connected with old/ unsv indoor panel is to be dismantled/ taken out from the bldgs/ wall after re-routing and these cabled are to be connected with new outdoor LT panel using lugs & glands of suitable sizes complete all as directed. (ii) Disturbed/ damaged surface of wall/ location after dismantling of old/ unsv indoor panel is to make good properly as directed. (iii) Make of MCCBs - Schneider/ABB/L&T/Legrand (iv) Cost for all items/ works as above are deemed to be included in the quoted rate
(a) 4 Nos bus bars of high conductivity aluminium alloy, 3 Nos for phase (R,Y,B) rating 600 amp rating and 1 No for neutral rating 300 amp, mounted on DMC support with heat shrink sleeve - 01 set.
(b) MCCB 4 pole, 315 amp, 415 volts, 36 KA - 01 No ( Incoming)
(c) MCCB 4 pole 160 amp, 415 volts, 36 KA - 01 Nos. (outgoing)
(d) MCCB 4 pole 125 amp, 415 volts, 16 KA - 02 Nos. (outgoing)
(e) MCCB 4 pole 100 amp, 415 volts,,16 KA - 01 Nos. (outgoing)
(f) Voltmeter (0-500V) digital type -01 No
(g) Ammeter (0-400 amps) digital type with CT's - 01 No
(h) Indication lamp (R,Y,B), LED type - One set of three
(j) Grouting of panel including PCC work
M&L for repair/ overhauling of existing APFC panel of 80 KVAR rating incl cleaning with compressed air, tightening of all electric connections, replacement of wornout/unserviceable parts such as automatic power factor controller relays, capacitors, contactors, CTs, cable of suitable capacity/rating with supply & replacement of lugs, nut, bolts, internal wiring with suitable size of PVC copper conductor wire, lugs/ thimbles of required size, incl any work not included above but considered necessary for efficient performance of APFC panel and testing on completion complete all as specified & directed. Note :- Spare parts such as capacitors, relay, MCBs, contactor & indiacator lamps will be measured and paid separately
Supply only following item/ spares for APFC Panel :-
Capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 volts & 50 Hz system for permissible non- linear load 15% of 10 KVAR capacity (Make-Schneider/L&T/Havells)
S&F (in replacement) lightning arrester, metal oxide type (gap less) for out door use complete with all fittings and fixing arrangements, transmission class, discharge capacity 65 kilo amps, suitable for 11000 volts including brackets, clamps, nuts, bolts, washers and connecting to earth wire 4mm dia GI with manufacturers test certificate complete all as specified & directed
M&L in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size for HT/LT 20 x 15 cm size complete all as directed
S&F (in replacement) following items in the existing panel / location and connection with using aluminum lugs including making necessary alteration in panel/door as required for proper fixing & connection complete all as specified and directed Note :- MCCB should be properly fited in existing compartment and operating handle of MCCB should be proper in opening existing cover/door of compartment of LT panel board
MCCB 3 pole 63 amps, 16 KA breaking capacity, 415 Volt, fixed type
MCCB 4 pole 63 amps, 16 KA breaking capacity, 415 Volt, fixed type
MCCB 4 Pole 100 amps, 16 KA breaking capacity, 415 Volt
MCCB 4 Pole 125 amps, 16 KA breaking capacity, 415 Volt
MCCB 4 Pole 200 amps, 25 KA breaking capacity, 415 Volt
MCCB 4 Pole 250 amps, 25 KA breaking capacity, 415 Volt
MCCB 4 Pole 350 amps, 35 KA breaking capacity, 415 Volt
Volt meter (0 to 500 volts) digital type, three phase of size 96mm x 96mm
Amp meter (0 to 500 amps) digital type, three phase of size 96mm x 96mm with suitable CTs
Indicator lamp, LED type
S&F steel tubular electric pole, swaged type (single swan neck), type 410 SP-31 (9 metre long) complete with CI base plate, bolts, nuts & screws all as specified including the following:-
(a) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in soft loose soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 metres.
(b) M&L for Providing PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) in foundation 600mm x 600mm x 1500 mm (planting depth) for concrete encasing the pole upto GL
© M&L for Providing PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia
(d) M&L for painting of pole externally with one coats of black bituminous paint (upto planting depth) and above plinth block/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide black bands/strip 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above coping level complete all as directed
Dismantling and taking out unsv / damaged PCC pole any size/type complete
S&F (in replacement) bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent to shape fixed on pole/wall with and including 50x6mm FI clamps - 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete
M&L in repair for loop junction box, outdoor type, size 30cmx20cmX15cm, made out of engineering plastic one piece moulding type, bus bar rating 63 amps 4 strips aluminium with bus bar mounting colour R, Y, B, N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colout, shock proof, rust proof, fire retardant, having front opening and locking arrangement with MCB SP 10 amps - 01 No, box duly fixed on the pole with flat iron clamp of size 25 mmX3mm with nuts & bolts complete all as specified and directed (Note : Cost of incoming& outgoing cable lugs & glands of suitable size deemed to be included in the quoted rate) (Make : Unilac / Universal Switch Gear Control / Sintex / Tricolite)
M&L (in replacement) for LED street/security light fittings 45 watt, made up of of pressure die cast aluminium housing with toughned glass and individual high power LEDs with secondary optics, IP 66 protection, to be mounted on existing/ new GI bracket and connecting the street light fitting using 1.5 Sqmm PVC insulated copper cable complete all as directed. (Note - New GI bracket with clamp shall be measured & paid seperately) (Make of LED light fitting :- Havells/Philips/Wipro/GE)
All as per the description of srl item No 45 above but LED light fitting 60 watt
All as per the description of srl item No 45 above but LED light fitting 90 watt
M&L for LED Flood Light luminaire, energy saving & enviornmental friendly, long life diecast aluminium, IP65, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connection using 1.5 Sqmm PVC insulated copper cable complete all as directed for following wattage :-
S&F (in replacement) LED Post top lantern luminaire 40 Watt, 5700 K, energy saving, environmental friendly, long life aesthetically designes with symmetrical light distribution, spun aluminium landscape luminaire with high power LED as light source, clear acrylic cover, IP-65 incl connection using 1.5 Sqmm PVC insulated copper cable complete complete all as directed (Make: Havells/Philips/Wipro/GE)
Repair of earth pit including required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed
M&L for earthing complete with galvanised steel earth plate electrode 600cm x 600cm x 6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI earth wire 4mm dia by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing wire PCC chamber 1:3:6 (type C-1) using 20mm graded crushed stone aggregate, watering pipe 20mm bore light grade, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point/equipment and testing complete
All as per above but with GI strip 32 x 6mm as earthing lead (earth strip will be protected by using 50mm bore GI pipe 'light grade')
M&L for servicing of DG set capacity 10 KVA, 3 phase, 415 Volt, 50 Hz including carrying out maintenance and check alongwith following repairs including replacement of worn out parts :- (a) Replacement of lubricating oil (b) Replacement of Engine Oil filter cartridge with New one. (c) Cleaning /Descaling /Callibration of Deisel fuel tank and writing date of cleaning complete (d) Renew fuel filter cartridge with New one. (e) Check tightness of all nuts and bolts. (f) Check adjustment of V belt for driving engine water pump and alternator. (g) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction. (h) Servicing of radiator (j) Cleaning of air cleaner filter and renew after period of hrs run as specified by manufacture. (k) Checking complete exhaust system including examining puncture in the mufler and redoing the complete insulation for adequate noise and pollution reduction complete (m) Testing of DG set after repair & servicing for smooth running of DG Set as per Manufacturers Instructions as directed . Note:- Any minor parts as required at site shall be supplied by the contractor. Cost for the same shall be deemed to be included in the unit rate quoted.
S&F copper stranded cable PVC insulated three core PVC insulated for motor to starter of following sizes for various capacities of motors.
(a) 6 Sq mm
(b) 10 Sq mm
M&L for Disconnection electrical and water connection of the centrifugal pump and motor 10 HP with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt fixing the require new parts (parts such as shaft, impellor, coupling & bearing shall be supplied under relevant item of schedule) and complete re-fixing its in original position and making out all electrical and water connection and testing complete Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation, testing & commisioning
Supply only shaft suitable for centrifugal pumps for 10 HP
Supply only GM impellor suitable for centrifugal pumps for 10 HP
Supply only MS coupling suitable for centrifugal pumps for 10 HP
Supply only bearing suitable for centrifugal pumps for 10 HP
M&L for rewinding of electrical motor with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding complete with all insulation material such as colton top varnish etc of centrifugal pump set motor 10 HP complete
M&L for Disconnection electrical and water connection of the induction motor with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt including two coat of synthetic enameled paint over a coat of red oxide primer fixing the require new parts (parts such as shaft impeller and coupling bearing shall be supplied under relevant item of schedule) and complete re-fixing its in original position and making out all electrical and water connection and testing complete for the following size/ capacity of motors Note :- Rate includes transportation of motor from the place of installation for repairing and re-installing the same on existing foundation, testing & commisioning :-
Supply only shaft suitable for induction motor pumps for the following sizes :-
Supply only bearing suitable for induction motor pumps for the following sizes :-
M&L for rewinding of electrical motor with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding with all insulation material such as colton top varnish etc of centrifugal pump set motor complete all as specified and directed for the following sizes :-
S&F fully automatic star delta starter appx full load with necessary relay and air break contactor complete with incoming and outgoing connection complete including taking down existing complete all as directed of size/rating MN 16F of make L&T at load of 9-15 Amps. (Make : L&T or equivalent as approved)
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying pipes in loose/soft soil all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Supply, laying, jointing & testing of GI Pipe, medium grade, including all fittings in old/new position, laid in trenches/ wall including taking down the old/unsv pipe line complete all as specified & directed of following sizes :-
(a) 80 mm dia
(b) 50 mm dia
(c) 40 mm dia
(d) 25 mm dia
(e) 20 mm dia
(f) 15 mm dia (Note : Excavation and earth work shall be measured and paid separately under respective items of schedule)
S&F in repair gun metal, globe or gate valve, screwed down high pressure with iron wheel head, screwed both ends complete for the following sizes of pipes :-
(a) 50 mm dia
(b) 40 mm dia
(c ) 25 mm dia
(d) 20 mm dia
(e) 15 mm dia
Supply, laying, jointing and testing of Cast Iron Pipe with spigot & socketed end, centrifugally cast, Class LA push on joint laid in trenches in old/ new route as required at site including taking down the old/unsv pipe line complete all as specified & directed of following sizes:-
(a) 100 mm dia
(b) 150 mm dia [Note for item No.6 :- Contractor will make his own all necessary arrangement for execution / laying of pipe line work incl liasion with civil / local authority at civil area / road, as & where applicable/ required]
M&L for run lead joint in spigot and socketted pipe of size 80mm including spun yarn complete all as specified and directed for following sizes of pipes :-
(a) 100mm dia
(b) 150mm dia
M& L for cast iron bends (any type, radius and angle) tapers any type (straight, bend, increasing decreasing or double socket etc) tee piees, single branch, 'Y' junction, double branch cross (all sockets or socket & spigot) collars, caps and plugs for spigot socketed pipes upto 150 mm bore complete.
M&L for cast iron sluice valve of pressure class PN-1.6 type flanged and drilled at both ends, conforming to ISI mark and having gun metal spindle and rings including wheel for operating all as specified including two numbers flanged socket and jointing materials such as bolts, nuts, washers, rubbers/ fibre board gasket including taking down old unserviceable valve from pipe line of both ends complete of following sizes:-
(a) 100 mm dia
(b) 80 mm dia
Supply and fixing of non return valve of size 80mm dia, class PN-1.6, cast iron body, single door, both ends flanged type including all necessary fittings ie rubber gasket, nut & bolts, washers complete all as specified and directed.
M&L for bailing out the water from the semi underground/UG sump capacity upto 10,000 GLNS with out causing any interruption to regular water supply system and cleaning the same walls, roof and floor thoroughly by using wire brush/scrapper for removal of deposited scales/sludge/silt etc and removing the materials out of site cleaning thoroughly with water and bleaching powder and then by chlorine solution for complete anti bacterial disinfections with applying one coat of white wash inner and outer side including writing date of cleaning on the black board with white paint all as specified and directed (Note:- Rates quoted deemed to be inclusive of all T&Ps and safety equipments required at site)
M&L for bailing out the water from the semi underground/UG sump capacity 20,000 GLNS with out causing any interruption to regular water supply system and cleaning the same walls, roof and floor thoroughly by using wire brush/scrapper for removal of deposited scales/sludge/silt etc and removing the materials out of site cleaning thoroughly with water and bleaching powder and then by chlorine solution for complete anti bacterial disinfections with applying one coat of white wash inner and outer side including writing date of cleaning on the black board with white paint all as specified and directed (Note:- Rates quoted deemed to be inclusive of all T&Ps and safety equipments required at site)
M&L for PVC ball valves high pressure of PTMT with epoxy coated Aluminium rod & highd ensity plastic ball complete assembly screwed for iron pipe and fixed and taking out UNSV complete for the following sizes :-
S&F MS chequred plate of 6mm thick including provision of lifting handle for each plate on existing trenches/ manhole covers for semi under ground sumps according to site condition complete all as directed
M&L for construction of brick masonary valve pit chamber of size 1050mm x 1050mm x 1050mm (internal dimension) including necessary excavation and earthwork, PCC, brick work,12 mm thick rendering in cement mortar 1:4 on internal surface of valve pit and mild steel sheet cover 3mm thick and mild steel angle iorn frame size 40 x 40 x 5 mm around of valve pit, locking arrangement with pad lock of size 50 mm brass, 6 leavers and key (Make : Godrej) complete including two coat of synthetic enamel over a coat red oxide primer on steel surface with preparation of surface and including dismantling of existing valve pit complete all as specified & directed.
All as per the description of srl item No 80 above item but size 900mm x 900mm x 900mm
M&L for spray painting of complete water Pumpset of any type up to 10 HP capacity with two coats of synthetic enameled paint of specified colour after preparation of surface complete
M&L for painting of water supply pipes net works consisting of valves of any type and size at various pump houses inlcuding duly scrapping thoroughly the existing corroded paint / dirt/ dust / rust and preparing the surface and applying two coats of synthetic enamel paint over a coat of red oxide primer as per the colour code and marking the water flow directions on pipe lines as directed.
(a) 80 mm bore
(b) 100 mm bore
Supply only bleaching powder stable of 33% chlorine all as specified (Make : DCM/RMCO/Rayalaseema or equivalent)
M&L for earthing with Galvanised Steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI strip of size 25 X 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete
Supply only gland packing with wire rope 1/4 " 1/2"
Supply only rubber insertion sheet 4mm thick
S&F 3 pole power contactor ML-1.5 for starter incl taking down old one complete (Make : L&T or equivalent as approved)
S&F 3 pole power contactor MNX 9 having 1 NO of rating 9-25 Amps complete. (Make : L&T or equivalent as approved)
S&F single phase preventor for 3 phase motors fixed for star delta starters complete. (Make : L&T or equivalent as approved)
S&F Electronic Timers type ST 100, 415 V for 3-30 secs complete. (Make : L&T or equivalent as approved)
S&F Volt meter (0-500 volt) square/round digital type incl taking down old one complete
S&F Amp meter (0-100) square/round digital type incl taking down old one complete
M&L for preparation of old painted steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enameled paint of approved shade complete
S&F MCCB 4 Pole, 415 volt, 36 KA of following capacity on existing panel including removing old one complete (Make : Legrand/ L&T/ Havells/ Schneider) :-
(a) 200 amps, 36 KA, adjustible type
(b ) 100 Amps, 25 KA, fixed type
(c) 63 Amps, 25 KA, fixed type
S&F in repair battery brass terminal complete
Chemical, Boilogical, Potability Testing of water sample at Govt recognised/approved institute/Lab for potability and chemical analysis complete all as specified & directed.
Supply only Calcium Hypo Chlorite 65% to 70% granules as specified (Make : Aquafit or equivalent as approved)
S&F in replacement of water pressure gauge with black steel case, copper alloy wetted parts, snap-in- acrylic window with white plastic dial and plastic pointer having 0-21 kg/cm2 pressure range complete all as specified & directed (Make-Cummins/Kirloskar/WIKA)
Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as directed
Supply only Chlorination testing kit incl solution, glass vessels tubular type etc complete all as specified and directed
M&L for total hardness test (5-1000 mg/L) kit with coloured sample complete with all testing fitment and OT solution in rexine finish box. (Make- Aquafit/ Aquasol)
S&F (in repair) foot valves, without bypass arrangement, vertical installation, flanged type for iron pipe of 80 mm bore as per IS 4038 including taking out old unserviceable valve complete all as directed.
All as per the description of srl item No 103 here-in-before but for 50 mm bore size.
M&L PCC 1:4:8 type D-2, using 40 mm graded crushed stone aggregate including demolishing the existing damaged foundation complete all as directed
S&F in repair fully reflective sign board made of 18mm gauge stainless steel sheet frame of size 1200 mm x900 mm sorrounded by 25mm stainless steel square pipe all around ,applying two coats of synthetic enemal paint ( blue colour) over a coat of red oxide including writing letters of height not exc 30 cm each (approx letters exc 30 and not exc 60 in numbers of any kind like block, Roman, Italic, Indian, Stop, Commas, Short line, dashes, hypens, brackets etc as directed by Engr-in Charge) with using retro reflective tape using HIP grade one, entire frame welded to post of 3.0 M long MS pipe of 50mm bore light grade( 2.60 Mtr above Ground level and 0.40Mtr below Ground level), embeded on ground with PCC 1:2:4 type B1 using 20mm grade crushed stone aggregate including necessary earth work of 30cm x 30cm x 40cm post holes complete all as specified and as directed
Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc including making good the disturbed surfaces to match with the existing complete
M&L for point wiring with single core FRLS, PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) drawing through existing conduit pipe including replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete for the following :-
(a) One light point controlled by one switch
(b) One ceiling/exhaust fan point controlled by one switch
(c) One socket outlet 5 Amps controlled by one switch on same board
(d) One socket outlet 5 amps controlled by one switch on independent board
(e) One bell point controlled by one bell push switch
All as per the description of srl item No 108 above but wiring with 2.5 sqmm copper wire and 1.5 sqmm earth wire for socket out let 16 Amps on independent board
M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick suitable for modular/conventional switches/sockets/fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :-
(a) One light point controlled by one switch
(b) One ceiling/exhaust fan point controlled by one switch
(c) One socket outlet 5 Amps controlled by one switch on same board
(d) One socket outlet 5 amps controlled by one switch on independent board
(e) One bell point controlled by one bell push switch
All as per the description of srl item No 110 above but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 2.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire.
S&F Switch piano flush type 5/6 Amps single pole one way 230 Volts complete
S&F Switch piano flush type 15/16 A single pole one way 230 Volts complete
S&F Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volt complete
S&F Socket Outlet 2 in 1, 3/6 pin 5 and 15 Amp flush type 230 Volts complete
S/F Bell push, flush type 5 Amps 230 Volts complete
S&F electronic fan step regulator fiush type 120 watt, 230 Volt complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F lamp holder, 230 volt AC, PVC / Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb inverter type upto 4 Hrs back up 6500 K complete all as specified & directed
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
S&F modular switch 6 Amps, one way, one module 240 volts complete
S&F modular socket, 3 pin 6 Amps, 240 volts, 2 module complete
S&F modular switch 16 A, 1 module, 240 volts complete
S&F modular socket 6/16 A, 5 pin, 2 module, 240 volts complete
S&F modular Bell push 6 Amps, one module 240 volts complete
S&F fan regulator, step type, 120 W, humfree, AC, 230 volts, 2 module, modular complete
M&L in repair for submain wiring with two single core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete
All as per the description of srl item No 127 above but with 6 sqmm and 6 sqmm as earth wire
S&F sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 'C' curve, 240 Volt complete
S&F MCB DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete for the following no of way :-
S&F loadline distribution box 4 way, AC, TP & neutral metal enclosure, Glazed double dooor, 415 V, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable for MCCB 63/100 Amps as incomer and MCB SP as out going complete all as directed
S&F MCB, DP/SPN, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete of following rating :-
(a) 63 Amps
(b) 40 Amps
S&F MCB SP, 240 Volts, AC, 6 to 32 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete
S&F MCCB 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line DB & connection complete of following rating :-
(a) 63 amps rating
(b) 100 amps rating
Supplying and laying in replacement or fixing or passing through pipe, 1100 volts grade PVC insulated aluminium stranded conductor cable, unarmoured, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circuler for the following size of cables :-
(a) 6 Sqmm
(b) 10 Sqmm
S&F in repair LED Bulkhead luminaire 10 watt of polycarbonate housing and enclosed with acrylic diffuser IP-65 protection incl connection complete
S&F in repair wall mounted LED batten with aluminium housing and initigrated electronic drive 18/20 watt fixture 4 feet provided for efficient heat dissipation with polycorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete
S&F in repair surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive, pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete
S&F in repair surface/ceiling mounted LED panel type of size 2ft x 2ft, 36W, 230V, 5700K complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete
S&F energy saving LED security light fitting of 45 watts with pressure die-cast aluminium IP 66 luminaire with high power LED as light source comprising with electronic driver and all accessories prewired incl connecting up with PVC insulated copper conductor cable 1.5 sqmm, 3 core for connections and incl suitable GI tube bracket for mounting of light fitting, bend to shape at required degree and fixed to wall by means of suitable flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
S&F in repair LED Post top lantern luminaire with die cast aluminium spigot, lid cover and clear acrylic cover 40 watt, 5700 K with IP-65 protection incl connection complete (Make: Crompton cat Pt No LPTO-40-CDL or equivalent in Havells/Philips/Wipro)
S&F in repair fresh air ventilating Fan 230/250 mm sweep, 230V, AC, plastic body with louver shutter etc complete and connection from ceiling rose to fan terminal incl cutting of hole at wall of required size and making good disturbed surface complete
Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 10 sqmm 2 core nominal cross section complete
S&F in repair PVC flexible twin twisted copper conductor cable multi strand of size 0.5 sqmm nominal cross section complete
S&F electronic energy meter, current rating 10-60 amps, 240 Volt, AC, single phase, 2 Wire, accuracy Class 1.0, with LCD display incl/ fitted with temper proof meter box, weather proof, transparent, made out of FR polycarbonate, dust proof, good mechanical strength conforming to IS: 14772/2000,IP-65, size not less than 260 mm x 190 mm x 120 mm incl connection and depositing old meter to MES store complete all as directed (Make of meter - Secure/Schneider/L&T/Havells)
M&L for earthing with Galvanised Steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI wire of size 4mm dia as earthing lead (upto the body of the equipment) by means of GI bolts, nuts, check nuts and washers and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete
S&F switch piano, flush type, 5/6 Amp, single pole, one way, 230 volts (in replacement) complete
S&F socket outlet 2 in 1, 3 pin, 5/6 Amp, flush type, 230 volts (in replacement) complete
S&F switch piano flush type 15/16 Amp, single pole, one way, 230 volts (in replacement) complete
S&F socket outlet 2 in 1, 3/6 pin 5 and 15 Amp, flush type, 230 volts (in replacement) complete
S&F Bell Push, flush type, 6 Amp, 230 Volts (in replacement) complete
S&F modular switch 6/10 amps single pole one module, 230 volts (in replacement) complete
S&F universal modular socket, 6/10 Amps, 5 pin, 2 module, 230 volt (in replacement) complete
S&F modular switch 16/20 amps single pole one module, 230 volt (in replacement) complete
S&F modular socket 16/20 amps, 2 module, 230 volt (in replacement) complete
S&F modular bell push with indicator 6 amps, one module (in replacement) complete
S&F fan step regulator 120 watt 2 module , 230 volt (in replacement) modular complete
M&L for dismantling of unsv C/Fan of any make/model/sweep, cutting and removing the old defective/burnt winding, cleaning the core of fan motor and rewinding the fan motor with super enamelled copper winding wire of same gauge with insulating material and varnishing the core assembly, drying the moisture content to get appropricate speed and re-assemble the same complete all as directed (Note :- The cost of copper winding wire is deemed to be included in the quoted rate)
All as per the description of srl item No 158 above but for exhaust fan upto 300mm sweep size
All as per the description of srl item No 158 above but for exhaust fan of 380/450mm sweep size
S&F in repair capacitor 2.5/3.15 MFD, ISI marked for C/fan incl connection complete
M&L in repair ball bearing suitable for any type/size/make of fan complete (Make-NBC/SKF)
S&F wall mounting fan 400 mm sweep, adjustable, plastic blade grill for protection, pull cord control for speed and oscillation on-off, ABS body incl connection and depositing old/ unsv fan in MES store yard complete all as directed (Make- Havells/Khaitan/Usha)
Taking down carefully electric geyser of any type and capacity by disconnecting electric and water supply connection, opening nut, bolt, washer and replacing the defective parts and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed. Note: Spare items shall be measured and paid seperately as supply only under relevant items
Supply only geyser inner water tank 35/50Ltrs capacity steel body as per sample, duly tested complete all as specified and directed.
All as per the description of srl item No 165 above item but 25 Ltrs capacity
Supply only of Heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample) complete (Make : as per sample/ make as per existing geyser)
All as per the description of srl item No 167 above item but capacity 2 KW
Supply only thermostat suitable for 50/35/25 ltrs capacity geyser (Make :- as per sample/ make)
Supply only heavy duty hot water connection, SS rope threaded type with brass unions at both ends, 45cm long 15mm bore complete.
Supply only indicator lamp suitable for geyser of any type/capacity (Make as per sample)
Supply only geyser base plate assembly of any capacity any model complete (Make as per sample)
S&F in replacement of outer cover MS sheet/ABS body of geysers 25 to 50 Ltrs capacity complete all as directed
S&F in repair Plug top, 3 pin, 05 amps, 230 volt incl connection complete
S&F in repair Plug top, 3 pin, 15 amps, 230 volt incl connection complete
S&F in repair PVC insulated and sheathed flexible cable 3 core Multi-stranded copper conductor size 2.5 Sqmm 1100 volt grade after taking out old unserviceable one including electric connection complete
M&L for taking down carefully window/split type Air conditioner 2/1.5 Ton capacity of any type/make from window/wall and removing front grills, air filters and cleaning, removing dust, washing and servicing with chemical wash of cooling and condenser coil and re-assembling the dismantled components and fixing to its original position complete all as specified & directed
M&L for servicing of water cooler 40/80 ltr capacity any type/make including disconnection of electric /water supply connectin and servicing with washing, removing dirt and fixing its original position including electric and water connection complete
M&L for charging of refrigerant R-22 / R-410 or any other recommended refrigerant gas in 1.5/2 Ton window/split Air conditioner/ Refrigerator/ Water Cooler any cap including detecting leakage and rectify the leakage with proper brazing and testing on full load complete
S&F in repair starting relay suitable for air conditioner 1.5/2 Ton/ Water cooler/ Refrigerator any cap
S&F in repair fan motor assembly of water cooler any cap of cooling capacity 40 to 60 ltr per hour including all accessories complete
M&L in repair copper tubing 1/2" dia with existing gauge for suction/discharge line of split air conditioner of 1.5 Ton/2Ton capacity including high quality puf insulation complete
All as per the description of srl item No 182 above but size 3/8" dia
S&F in repair outdoor unit suitable for 1.5 Ton split AC including rotary type compressor, high EER, copper material condenser unit, eco friendly refrigerent etc with all accessories complete in all respect all as directed (Make : Hitachi/LG/Voltas/Blue Star)
S&F in repair of cromium plated brass push cock 15mm dia, ISI Marked, for water cooler complete
S&F in repair plastic submersible pump suitable for desert cooler any size complete
S&F desert cooler pad (set of three) made out of wood wool etc for desert cooler any size.
S&F desert/Air cooler of body size 25"x25"x32", made out of corrosion resistant, 18 SWG GI sheet duly powder coated paint with 500mm sweep copper wound fan motor kit of not less than 145 watt with metallic blade, ISI marked, 1400 RPM, 230 volt AC, tank capacity not less than 100 ltr, incl plastic submersible pumps, electronis fan regulator with P/switch and old/unsv desert cooler depositing in E/M Store yard complete all as directed (Make : JK Classic/Decool/Supreme/Kapsun/ Crompton/ Supercool)
S&F in replacement motor single phase, 1/5 HP capacity for split type AC 1.5/2.0 ton capacity complete (Make : As per sample/make)
S&F in replacement hermetically sealed rotary type compressor unit of capacity 1.5/2 T for split/window type AC and charging of adequate quantity of refrigerant gas and testing on completion complete (Make : Blue Star/Carrier/Kirloskar/Hitachi/ Mitsubishi/Dakin)
All as per the description of srl item No 190 above but for water cooler of any capacity/make
S&F in repair Power Circuit Board (PCB) suitable for split type AC of capacity 1.5 / 2.0 TR complete
S&F in repair indoor unit suitable for 1.5 Ton split AC with PCB, LCD with temperature remote controller, noise level not less than 50 db etc with all accessories complete in all respect all as directed (Make : Hitachi/LG/Voltas/Blue Star)
S&F in repair electronic voltage stabilizer, single phase suitable for 1.5/2 Ton air conditioner having I/O correction range of 160-280 volt complete all as directed (Make : Microtech/Blue Bird/V-Guard/Zenith/Sinetrac)
S&F in repair ceramic porcelain heating element suitable for geysers of 25 ltr cap/ make as per sample
S&F in repair fan motor kit assembly of 450 mm sweep, single phase, not less than 145 watt, AC, 50 Hz, copper wound with blade for desert cooler complete all as directed
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - 1,61,989.00
J.P. Enterprises
Shiv Enterprises
NEERU ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .