Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.6 L+₹51,537.45 (10.2%)Rejected-Finance 93 4 16A BLOCK NO 3 JAWAHAR CHOWK PACHMARHI MP 461881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L2 | Rejected-Finance Not Admitted | |
| 3 | L3₹5.6 L+₹56,730.95 (11.2%)Rejected-Finance SURVEY NO 93 392 PACHMARHI NEAR MILITARY HOSPITAL PAHMARHI HOSHANGABAD M P 461 881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L3 | Rejected-Finance Not Admitted | |
| 4 | L4₹5.9 L+₹84,531.85 (16.7%)Rejected-Finance NEAR BUS STAND PACHMARHI MP PIN 461881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L4 | Rejected-Finance Not Admitted | |
| 5 | L5₹10.1 L+₹5.0 L (99.3%)Rejected-Finance | L5 | Rejected-Finance Not Admitted |
Tender Value
Refer Docs
EMD Value
₹14,800
Closing Date
7 Oct 2021, 6:00 pmClosed
AGE Indpt Pachmarhi
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
SPL REPAIR TO BLDG NO P-139 IN CHUSUL COY AT AEC TRG COLLEGE AND CENTRE PACHMARHI
2021_MES_473622_1
CA No. AGE(I)/PACH/ of 2021-22(8422/E8)
Open Tender
Civil Works
Item Rate
180 days
Pachmarhi MP
Class E Caregory a(i)
8 documents required · 8 mandatory
₹500
AGE Indpt Pachmarhi
₹14,800
Yes
22 Apr 2022
8 Sept 2021
11 Oct 2021
8 Sept 2021
7 Oct 2021
23 Sept 2021
Amount
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of 250 to 500 ltr capcity (Cleaning repairing, etc. measured separately)
Taking up or down steel water tubing and connections of 15mm bore complete all as specified and as directed.
Taking up or down steel water tubing and connections of 20 mm bore complete all as specified and as directed.
Fixing only 15mm bore galvanised steel water tubing (GI pipe), medium grade with all fittings and fixed to wall, floor and ceiling of following bore complete all as specified and as directed
Fixing only 20 mm bore galvanised steel water tubing (GI pipe), medium grade with all fittings and fixed to wall, floor and ceiling of following bore complete all as specified and as directed
Removing/taking down of old water proofing treatment from roof/concrete surface removal to distance exc 250mtr and not exxc 500mtr from the site & cleaning of the roof surface with wire brush to make it free from dust, dirt etc all as directed by EIC.
M&L for bedding layer of mortar 10 mm thick finished fair and even in CM 1:4 mixed with water proofing compound (liquid WPC shall be measured seperatly).
M&L for water proofing treatment with APP modified membrane 3mm thick consisting of the following for Unapproachable RCC roof:- (a) Cleaning plastered roof surface and applying a coat of Oxidised bitumen based solvented primer @ 0.3 kg/Sqm of approved make on top of dry surface of RCC roof complete all as specified and directed. (b) M&L for APP modified polymeric waterproofing membrane weight not less than 3.00 kg/sqm with centre core as100 micron HMHDPE film. The centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point. The polymeric mix is protected on both sides with 20 microne HMHDPE film with lap of 100mm and the overlap shall be selaed by flame complete all as per manufacturer instructions and as directed by Engr-in-charge. (c) M&L for applying a tack coat of industrial bitumen 85/25 at the rate of 1.2Kg per sqm including cleaning surface. (d) M&L for applying protective coating with bituminous based aluminium paint @ 0.2kg per sqm in two coats compete all as specified and directed.
Supply only integral water proofing compound.
Demolition of PCC in ground floor and pavings not exc 15 cm thickness below or above ground level complete all as specified and directed.
M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.complete all as specified and directed.
M & L 100 mm thick for cement concrete type 1:4:8 type D2 (40 mm graded aggregate) in sub base complete.complete all as specified and directed.
M & L 100 mm thick for PCC type 1:2:4 type B2 (40 mm graded aggregate) as in floor surface finished even & smooth without using extra cement.complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection surface finished fair and even without using extra cement complete all as specified and directed.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
Point wiring with 1100 volts grade PVC insulated FR -LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete for the following :-
One light point controlled by one switch.
One fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on indepdendent board.
Point wiring with 1100 volts grade PVC insulated FR LSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for one 16 amp socket outlet controlled by one switch on independent board complete.
S&F angle holder, insulated polycabonate body with back plate complete.
S&F switch piano flush button single pole one way 6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
S&F MCB distribution board SPN, 240 volts, 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FR-LSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including rigid non metallic PVC conduit, medium grade, ISI marked ivory colour 20 mm dia along with accessories of nominal sizes 2x6 sqmm + 1x4 sqmm earth continuity conductor complete.
S&F LED batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make : Philips cat ref no. ENDURALED BATTEN "BN 108C LED 20S PSU CDL WH" or equivalent in Havells or GE Lighting as approved.
S&F LED bulkhead fitting 9 watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired for connection with flexible multi stranded copper conductor cable as required all as per Philips cat ref no. WT202W LED6S CW PSU S1 PC or equivalent in Havells or GE Lighting as approved.
S&F energy efficient recessed/surface mounted LED luminaire 36 Watt suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required. Make - Philips cat ref no. RC365B LED33-5000PSU OD WH or equivalent in Wipro / Havells STRATO2x2 or C&S as approved.
S&F LED 20 Watt streetlight made up of prressure die cast housing with prismatic polycarbonate diffuser and individual LED's with secondary optics and IP 65 protection complete with fixing arrangement and connection as directed as per Bajaj cat ref No. BCLST 20W LED I code 169829 or equivalent in Havells or GE Lighting as approved.
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
Single pole 6 to 16 amp. Make : Legrand/Hager/ Indoasian
Double pole 32 amp. Make : Legrand/Hager/ Indoasian
Taking down Ceiling Fan of any make, type and sweep by disconnecting Electric Connection and keeping in safe castody for repair.
Dismantling of ceiling fan from existing location any sweep of any make, cleaning throughly, servicing of fan motor & parts fitted there in, oiling, greasing to bush / bearings, replacement of unserviceable parts required, applying two coat of white synthetic enamel paint over one coat of primer on fan blades and body, re- assembling, testing hanging at site as directed.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Taking down carefully aluminium or copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete.
M&L earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x6.0mm thick buried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5m below ground level connected to and including galvanized iron wire 4.0mm not exceeding 7.5meters for each earth without protection pipe, including test point by means of bolts, nuts, check nuts, and washers made out of GI all as shown on plate No 5 of SSR Part I to the extent applicable to this item including necessary making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia MS bars 3 Nos both ways with lifting hook made out of 6 mm dia bar and testing on completion to achieve value complete all as specified and directed.
DEEPAK JAISWAL
Dev Enterprises
SUBIR KUMAR ROY
ESS AAR AND CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .