Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹19.6 L+₹1.3 L (6.99%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹21.0 L+₹2.7 L (14.8%)Rejected-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹21.2 L+₹2.9 L (16.1%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹22.8 L+₹4.6 L (24.9%)Rejected-AOC 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
16 Sept 2020, 6:00 pmClosed
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS FIXTURES RENEWAL OF EARTHINGS AND OTHER CONNECTED ITEMS IN MD OTM ACCN BUILDINGS OF DEPOT BN TB I MEG RECORDS CICE MDC MEANEE LINE GE NORTH CIW AND PAO ORs MEG UNDER GE N
2020_MES_369692_1
8471
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANGALORE
Class E category b (i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹44,000
Yes
9 Oct 2020
20 Aug 2020
18 Sept 2020
20 Aug 2020
16 Sept 2020
4 Sept 2020
20 Aug 2020 - 3 Sept 2020
Amount
Taking down carefully aluminium / copper wiring / power point wiring (light, fan,call bell socket or power circuits) complete and making good the disturbed surface of walls, ceiling etc including painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories surface type wiring including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed mounted / on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for:- (a) One light point controlled by one switch.
(b) One fan point controlled by one switch/regulator .
(c) One light point controlled by two 2 way switches.
(d) One 3 pin socket out let 5 Amps on independent board.
(e) One bell/buzzer point controlled by bell push.
(f) One 3 pin socket out let 5 Amps on same board.
All as per Sl Item No 1.02 above but concealed wiring drawn through existing conduit:- (a) One light point controlled by one switch.
(b) One fan point controlled by one switch/regulator.
(c) One light point controlled by two 2 way switches.
(d) One 3 pin socket out let 5 Amps on independent board.
(e) one bell/buzzer point controlled by bell push.
(f) one 3 pin socket out let 5 Amps on same board.
Point wiring complete with 2.5 Sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC rigid conduit medium grade, ISI marked with accessories surface type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through existing PVC conduit incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Labour only for re fixing of point wiring by using existing 1.5 sq.mm PVC insulated unsheathed multi stranded copper conductor cable drawn through existing PVC conduit fixed with saddles of suitable size including electrical connection to switches/ sockests / ceiling roses etc and refixing of existing hylem sheet with accessories over MS sheet concealed / surface mounted on walls with new cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc complete all as specified and directed for :- (a) One light point controlled by one switch. NOTE:- The fittings such as switches, sockets, regulators, ceiling roses etc replaced will be mesasued under relevent items of the schedule for the following:-" (a) One light point controlled by one switch. NOTE:- The fittings such as switches, sockets, regulators, ceiling roses etc replaced will be mesasued under relevent items of the schedule
(b) One fan point controlled by one switch/regulator.
(c) One 3 pin socket out let 5 Amps on independent board.
(e) one bell/buzzer point controlled by bell push.
All as per Sl Item No. 1.16 here-in-before but for 16 Amps socket outlet by using 2.5 sq.mm PVC insulated unsheathed multi stranded copper conductor cable on independent board including provn of 2.5 sq.mm PVC insulated solid copper conductor as contineous earth wire. NOTE FOR SL ITEM No 1.02 to 1.20 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED batten suitable for indoor applications 18 Watts, 4 feet with polycarbonate housing and integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj Cat No. 830192 18W CDL or techno commercially eqivalent models specified in PS complete all as specified and directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing and integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj Cat No. 830206 10W CDL or techno commercially eqivalent models specified in PS complete all as specified and directed.
Recess mounted LED Luminaire 36 Watts of size 2' x 2' white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with accessories all as per Bajaj Cat No : BZRSQL 36W GZI WH or techno commercially equivalent makes specified in PS including taking out old fittings all as specified and directed.
Surface mounted LED Luminaire 36 Watts of size 2' x 2' white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with accessories all as per Bajaj Cat No : BZSSQL 36 WH or techno commercially equivalent makes specified in PS including taking out old fittings all as specified and directed.
Replacement of Switch piano flush button single pole two way 5 Amps all as specified and as directed.
Replacement of Angle holder PVC/polycarbonate type all as specified and as directed
Replacement of switch piano, flush type, single pole, one way 5Amps complete all as specified and as directed.
Replacement of switch socket combination 5 pin 2 in 1, 5 Amps, flush type all as specified and as directed.
Replacement of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed.
Replacement of socket outlet 2 in 1, 3 pin 5 Amps all as specified and as directed.
Replacement of bell push, flush type, 5 Amps all as specified and as directed.
Replacement of MCB SPN 240 volts 40 Amps, 'C' curve complete all as specified and as directed.
Replacement of MCB single pole 240 volts 6 to 32 Amps, 'C' curve complete all as specified and as directed.
Replacement of MCB TPN, 415 volts, 32 to 63 Amps, 'C' curve complete all as specified and as directed.
Replacement of MCB DB SPN, 4 ways, double door type, 240 volts with 200 Amps rated busbar as specified and as directed.
Replacement of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
Replacement of MCB DB TPN, 4 ways with double door type, 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed.
Replacement of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed.
Replacement of stepped type electronic fan regulator flush socket type all as specified and as directed
Replacement of stepped type electronic fan regulator flush switch type all as specified and as directed.
Replacement of Ding Dong bell AC 230 volts single pole, all as specified and as directed.
Sub main wiring with two runs of single core FRLS grade 6 sq.mm, 1100 volts grade multi stranded copper conductor cable along with one run of FRLS grade 6 sq.mm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn through and including non metalic rigid PVC conduit medium grade of suitable size including taking down the existing complete all as specified and as directed. NOTE:- Two runs of 6 sq.mm cable, one run of 6 sq.mm earth continuity conductor and one run of PVC conduit shall be measured as one unit for payment purpose.
Sub main wiring with two runs of single core FRLS grade 4 sq.mm, 1100 volts grade multi stranded copper conductor cable along with one run of FRLS grade 4 sq.mm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn through and including non metalic rigid PVC conduit medium grade of suitable size including taking down the existing complete all as specified and as directed. NOTE:- Two runs of 6 sq.mm cable, one run of 4 sq.mm earth continuity conductor and one run of PVC conduit shall be measured as one unit for payment purpose.
Sub main wiring with four runs of single core FRLS grade 6 sq.mm, 1100 volts grade multi stranded copper conductor cable along with one run of FRLS grade 6 sq.mm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn through and including non metalic rigid PVC conduit medium grade of suitable size including taking down the existing complete all as specified and as directed. NOTE:- Four runs of 6 sq.mm cable, one run of 6 sq.mm earth continuity conductor and one run of PVC conduit shall be measured as one unit for payment purpose.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I including excavation and earth work in any type of soil, funnel, 20 mm dia light grade GI watering pipe and 15mm dia light grade GI protection pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
LED Building security light fittings 25 Watts with pressure die cast housing, with secondary optics and IP 65 protection, complete with accessories all as per Bajaj Cat No : BREP 25 W LED WH or techno commercially equivalent makes specified in PS including taking out old fittings all as specified and directed.
Bracket made out of GI tubing medium grade 25 mm bore of approx length 1.5 mtr including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc., applying two coats of aluminum paint over a coat of red oxide primer before fixing including removing the old existing GI bracket from building complete all as specified and as directed.
Replacement of RCBO double pole 30 mA ,240 Volts, 32 Amps 10 KA breaking capacity complete all as specified and all as directed.
Replacement of single pole and neutral enclosure, 20 Amps, 240 volts with two pin earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
Removing of existing wooden meter box, supply and fix 3mm thick GI sheet of suitable size fixed on angle frame fitted to wall including removing and refixing of 4 Nos electric meter and DB with internal wiring beteween DB and meters with FRLS copper cable of existing size, complete with all accessories all as specified and directed.
RAMSON TRADERS
Vasavi Electricals
LITE SYSTEMS INDUS
SREE VINAYAKA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .