Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.3 L+₹2.4 L (7.87%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹33.1 L+₹3.1 L (10.4%)Rejected-AOC NEAR NATRAJ MANDIR NEW INDIA COLONY PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹34.5 L+₹4.5 L (15.0%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹34.8 L+₹4.8 L (15.9%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
4 Dec 2023, 6:00 pmClosed
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
PROVN OF ROAD ALONGWITH STREET LIGTHING FROM BLDG NO P-26 TO FISH PT SENTRY POST UNDER AGE B/R-II OF GE(N) MAMUN
2023_MES_628210_1
GE(N)/M-55/2023-24
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹86,000
3 Jan 2024
14 Nov 2023
6 Dec 2023
14 Nov 2023
4 Dec 2023
28 Nov 2023
Amount
Surface excavation in hard/dence soil not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of Soil complete all as specified and directed.
Excavation in trenches, n.exc. 1.5 m wide and n.exc 1.5m in depth for foundation, laying of cable, etc, or for shafts, wells, drain pipes n.exc 10 sqm on plan and n.exc 1.5m depth and getting out in any type of soil complete all as specified.
All as per Srl item No 02 above but depth exceeding 1.5m and not exceeding 3.00m
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for rolling and consolidating formation surfaces in cutting by hand roller of 02 to 0.5 tonnes complete all as specified and directed.
M&L for 100 mm thick PCC, type C2, 1:3:6 (40mm graded crushed stone aggregate) in Sub-base, floor and pavings etc complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 ( using 20 mm graded stone aggregate) as seismic, plinth and similar bands, coping, kerbs, cills, steps, parapets, apex stones, bed plates, kerbs, railings up to 60 cm in height, water troughs and the like rounded or chamfered on edges including necessary form work complete all as specified & directed.
M&L for cement concrete (1:3:6) type C1 ( using 20 mm graded stone aggregate) as seismic, plinth and similar bands, coping, kerbs, cills, steps, parapets, apex stones, bed plates, kerbs, railings up to 60 cm in height, water troughs and the like rounded or chamfered on edges including necessary form work complete all as specified & directed.
S&F of machine pressed precast conctete coloured interlocking paver block of any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade including joint filling with gray cement and pigment to match the shade complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1(using 20mm graded stone aggregate) as in surface channel and drains including necessary formwork complete all as specified and directed
M&L for forming fair finished drain or channel any inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for Brick work with fly ash bricks (Old Size bricks) straight or curved on plan exc 6 mtr mean radius built in CM (1:6) complete all as specified and directed.
M&L for 600 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1(using 20mm graded crushed stone aggregate) as in foundations, filling and mass concrete including necessary formwork complete all as specified and directed
M&L for 15mm thick cement plaster in CM 1:4 in on brick work surfaces finishing the surfaces even and smooth without using extra cement all as specified and directed.
M&L for preparing newly plastered surfaces and applying two coats of cement base paint over one coat of primer on walls complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc 40mm to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
M&L for raised pointing in CM 1:4 to random or polygonal rubble, uncoursed or brought upto courses complete all as specified and directed.
M&L for Precast RCC type B, 1:2:4 (using 20mm graded crushed stone aggregate) Bond stone, set in CM 1:4 complete all as specified and directed.
S&F TMT bars (Fe 500),10 mm dia and over in reinforcement cut to length, bent to shape required including bending spirally cranking, hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F Mild steel TMT bars, 5mm dia and over upto including 10 mm dia as in stirrups, spacers etc, bending spirally or hooping for columns, hooking ends and binding with and including mild sleel wire not less than 0.90mm dia complete all as specified and directed.
M&L for dry boulder filling, hand packed highly as in back filling of wall complete all as specified.
Excavation over an area n.exc 1.5m deep and getting out in hard & dense soil complete all as specified and directed.
M&L for Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base in hard & dense soil complete all as specified and directed.
M&L for hardcore of gauge n exc. 63mm, broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed as weep hopes to wall complete all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, excavation in any type of soil for laying upto 25cm depth and removal of soil complete all as specified and directed.
M&L for applying Two coats of premium acrylic emulsion paint and UV resistance, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives over and including priming coat of exterior primer applied over new surfaces including kerb stones etc complete all as specified and directed.
M&L for steel tubular swaged pole 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, duly applied a coat of red oxide primer (internally and externally). The pole shall be painted (above coping) with 05 numbers circular strips each of 30 cm (of colour combination as directed) with synthetic enamel paint duly marked pole number in approved pattern. The remaining pole shall be painted with two coats of aluminium paint complete all as spfd and directed. Note: The pole shall be erected in true verticle polition. Earth work i.e excavation, returning filling in, removal PCC and other related work shall be measured and paid separetly.
Supply, laying, connecting and testing XLPE insulated armoured heavy duty electric cable with PVC insulated aluminium multistranded conductor 1100 Volt grade cross sectional area 10 Sqmm 4 core with aluminium termination lugs, laid in trench/cable duct/through wall/pole, making good disturbed surface/ flooring/tilling to match with existing specification complete all as specified and directed.
S&F in replacement of GI tubing, light grade 40 mm bore with fittings laid for protection of cable under road crossing/ fixed to walls or pole complete all as specified and as directed. Note : Clamps of size 25x4mm for fixing pipe, nuts, bolts washers etc if required is deemed to be included in quoted rates.
S&F high power LED street light light 60 W, 230 volts with surge protection not less than 4 KV in built driver ( potted antivibration type), LM-79 and LM-80 FOR 50000 burning hrs, CRI >70, CCT of fixtures shall be 57000K ± 300K, system lumen efficacy >100 Lm/W & minimum 10 KV separate in the light housing, powder coated pressure die cast aluminimum housing, IP 65 protection with heat resistent toughened glass, suitable size service bracket fixed with clamps, nut, bolt washers etc and making electric connections complete all as specified and directed. Notes:- (a) 10 KV separate Surge Protection shall be provided as a part of fitting. (b) PCB shall be MC PCB type. (c) Fitting shall have arrangement so that maintenance, if required can be carried out form top cover. (d) Name of manufacturer shall be embessed on fitting.
S&F junction box water proof outdoor type made out of SMC of external dimensions 250 x 250 x 105 mm single door type hinged with locking arrangement front operated with one MCB 06 Amps, capacity for housing 3 phase and neutral busbar, connecting incoming/outgoing cables including necessary cable glands and fixed to the existing poles with mild steel clamp made of MS flat iron 25x4 mm (as per sample) with nut , bolts complete all as specified and directed.
M&L for 1.5 sqmm 3 core PVC insulated PVC sheathed multicore flexible copper conductor cable, 1100 Volts grade confirming to IS-694/2010 of size including drawn into the pole from junction box to light fitting after necessary drilling in the pole complete all as specified and as directed.
Supply and laying bricks sub class 'B', laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed.
M&L for sand cushioning to under groudnd cables in layers of sand of 23cm thick (8cm before laying the cable and 15cm thick after laying cable) in trenches complete as specified and directed. Note: Only punned thickness of 18cm shall be measured and paid.
kewal builders
D R CONTRACTORS
PARVINDER BHARDWAJ
JAGDISH SINGH ASSOCIATES
WALIA ENTERPRISES
M/S CANTILEVER ENGINEERS
new hi tech engineers and contractors
KUMAR TRADING CO
RD Engineers
A R ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .