| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹30.9 L+₹2.0 L (7.00%)Rejected-Finance | L2 | Rejected-Finance FOUND OTHER THAN LOWEST | |
| 3 | L3₹30.9 L+₹2.1 L (7.22%)Rejected-Finance | L3 | Rejected-Finance FOUND OTHER THAN LOWEST | |
| 4 | L4₹34.2 L+₹5.4 L (18.6%)Rejected-Finance | L4 | Rejected-Finance FOUND OTHER THAN LOWEST | |
| 5 | L5₹36.4 L+₹7.5 L (26.2%)Rejected-Finance | L5 | Rejected-Finance FOUND OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
3 Jul 2021, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR C/O 56 APO
SPECIAL REPAIR TO BLDG NO P-06 (OTM ACCN), SPECIAL REPAIR TO SECURITY WALLS AND PROVN OF PAVED AREA WITH PAVER BLOCK UNDER AGE BR-I UNDER GE (SOUTH) AKHNOOR.
2021_MES_448360_1
NIT-03
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH AKHNOOR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹80,000
16 Aug 2021
4 Jun 2021
5 Jul 2021
4 Jun 2021
3 Jul 2021
15 Jun 2021
Amount
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Demolition of cement concrete (reinforced) in ground floors and pavings/manholes and the like not exceeding 15 cm thickness (below or above ground level), including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-In-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete Nominal Mix (1:2:4) M-15, type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 50mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.
Glazed ceramic tiles in vertical surface/ dado, size 300x450mm/ 300x200mm, 6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (minimum size shall be 550x550mm), flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (size shall in one length), 18-20mm thick, as in riser of steps, skirting, dado and pillar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or back plastering layer of mortar 15mm thick in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Granite (of any type) work (table rubbed and polished), 15-18mm thick, as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by Engineer-In-Charge.
M&L for repairs to sunken floor/ slab with the following specifications:- (a) Demolition of PCC and taking out old brick bat fillihng and roughening surfaces of old concrete floor and wall by picking, sweeping clean and washing down with water to remove dust etc. (b) PCC 1:2:4,type B-0, using 12.5mm graded stone aggregate averaging 50mm thick as in sunken floor,with proper slope towards GI spout. The dia of GI Spuot pipe shall be 50mm Medium grade. The minimum length of Spout shall be 500mm and if any spout comes above chajja than the length of the spout shall be more than Chajja projection. Ends of Spout shall be tippered and any cutting through brick/ RCC structure shall be done by the Contractor rates are deemed to be included of this aspects. (c) providing 15mm thick cement plaster in cement mortar 1:3 mixed with water proofing compound @ 3% by weight of cement over bottom and vertical surfaces finishing the surface even and smooth without using extra cement. (d) Damp proof course on horizontal / Vertical surfaces with preparation & applying one coat of self priming (33% dilution) and two coats of undiluted material @ 10.67 lts per 10 sqm of Make : smart care Damp proof of M/s asian paint or equivelent for water proofing compound. (e) Graded Brick bats filling under sunken floor. (f) PCC 1:3:6,type C-1,using 20mm graded stone aggregate 75mm thick, over brick bats filling as in subbase to receive tiles. Note:- (i) For payment purpose only floor area shall be measured. (ii) After Coating of Water proofing compound ponding test shall be carried out by filling the sunken surface with water for 72 Hrs and get approved by Engr-in-Charge if any leakage/ seepage noticed the Contractor will re do the whole process without any extra payment.
Cutting holes in brick walls , Superficial area n exc 150 sqcm built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, complete all as specified and as directed by Engineer-In-Charge.
Grubbing up bushes , tree trunks portion not exc 30CM girth including cutting of trees/bushes grown in over wall and roofs digging out roofs and making good disturbed area of walls and roofs with PCC type C-1 , 1:3:6 using 20mm graded crushed stone aggregates and matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Repair to RCC projection chajjas , roof fascias etc by scraping , cutting, chiseling , de-rusting and cleaning of exposed reinforcement surfaces, losse RCC surface with cement concrete in M-20(1:1.5:3), type A-1, (using 12.50mm graded crushed stone aggregate), nominal mix and reinforcement with welded mesh had drawn steel wire fabric of weight exc 2.0Kg/Sqm but not exc 4.0Kg/Sqm cut to length and shape required and tie with and including mild steel wire (annealed) not less than 0.9mm in dia as required, with or without fascia and finished with cement mortar15-20mm thick in 1:3 in patches area not exc 5.0 Sqm and thickness of RCC members n exc 70mm incl necessary form work and applying two coats of finishes to match with the existing surfaces at any height , complete all as specified and as directed by Engineer-In-Charge. Note : 1.0 Cost of steel wire fabric of required weight and size as directed shall deem to have been included in the quoted rates. 2. Cost of necessary saftey arrangements like ladders, saftey harness, scaffolding shall also be deemed to have been included in the quoted rates.
Water proof treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, 2.0mm thick, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing chemical shall be included in quote rate.
Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed.
Tubes, 'medium grade' galvanised, 15mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.
Taking up or down steel tubing of 20mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed.
Tubes, 'medium grade' galvanised, 20mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.
Bib taps, long body, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Wall mixer with bend pipe for overhead shower with built-in non return valve, for hot and cold water, chromium plated, for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cat Part No-F1014402 of Cera/ Jaquar/ Parko/ Hindware.
Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Centre hole basin mixture for hot and cold water, chromium plated, with round sport without pop up waste system for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cat Part No-F1013451 of Cera/ Jaquar/ Parko/ Hindware.
PVC connections 15mm size with brass nuts of length 450mm, complete all as specified and as directed by Engineer-In-Charge.
PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 10.0 litres and making good to dismantled/ damaged surfaces, fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
S&F in repair counter top wash hand basin of size 550mmx425mm flat back, of white colour fixed with Granite/marble stone/ existing wall surface as the case may be and as directed including waste coupling and waste pipe , filling of joints between wash basin and the surface using white cement etc, complete all as specified and as directed by Engineer-In-Charge. Make : Cera Model No CONCORD 1032 or Equivalent makes in Kohler/Jaquar
Brass chromium plated shower rose 125mm size, fancy type, fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Ball valves, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Sheet glass shelf assembly, consisting 5.50mm thick sheet glass, 120mm wide including anti rust screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
CP grating 125mm dia heavy duty with or without hole for waste pipe, complete all as specified and as directed.
Disconnecting existing tank exceeding 250 litres but not exceeding 500 litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in same position after cleaning, mounted on any locations including removal of mud and dirts outside from residential area, including writing date of cleaning on outer surfaces with white synthetic enamel paint, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Contractor will submit duly signed user's completion certificate with building details countersigned by Engineer-In-Charge, for each tank before payments. (ii) Cost of all required tools, plants and labours shall be deemed included in quoted rate.
Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve 20mm dia with iron wheel head, both ends screwed for iron pipe including taking down of old one complete all as specified and directed for following bore of pipes.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to dismantled floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to dismantled floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Tubular towel rail, 20mm dia, D-type, 60cm long between flanges, brass chromium plated, fancy type, including end brackets, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Low density polyethylene (LDPE) pipes of 32mm bore, pressure rating 6.0 Kgf/Sqcm), 900mm long, complete all as specified and directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125x60mm, complete all as specified and as directed by Engineer-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 105x60mm, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified and as directed by Engineer-In-Charge.
Factory made solid panel PVC door shutter with wood free EPS, 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame with three Nos of stainless butt hinges of 100mm size and rust proof screws, at site as per specification and drawing, complete all as specified and as directed by Engineer-In-Charge.
Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and glass sheet 3.0mm thick, incl 4mm thick figured glass, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge.
Factory made, glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed by Engineer-In-Charge.
Factory made, 35mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and as directed by Engineer-In-Charge.
Galvanised mild steel wire cloth in repair, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, , complete all as specified and as directed by Engineer-In-Charge.
Mild steel square bar framed work such as in grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; frame work of water tanks and similar work conforming to Fe-290, Gde-E-165, including cutting and welding, complete all as specified and as directed by Engineer-In-Charge.
Framed work as in doors or gates of angle or other section and as in frame work of cooler stand etc, conforming to Fe-290, Gde-E-165, including cutting and welding, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing of cup board shutter 28 to 30 mm thick (style) factory made PVC incl chowkate frame made out of MS tubes of 19 guage for top and bottom rails M S frame shall be covered with heated molded designer colour PVC channel having PVC sheet strip of 10 MM width stuck inside with solvent cement for styles and plane colour PVC sheets of top rail, lock rail and bottom rail on either side 10 mm (5 mm x 2) thick of 20 mm and 20 mm cross PVC sheets and as gap inserted for top and bottom rail. Paneling for plain colour PVC sheets to be fitted in the MS frame welded /sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement in the frame at site as per drawing held with AGE B/R-I and to the entire specifications. , complete all as specified and as directed by Engineer-In-Charge.
Prelaminated particle board,19mm thick, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, as in cup boards, drawers, shutters, fixed with screws to timber frame work, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed by Engineer-In-Charge.
Aluminium handles, cast type, anodised, size 150mm, complete all as specified and as directed by Engineer-In-Charge.
Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.
Aluminium alloy, anodised, sliding door bolt, size 250mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-In-Charge.
Hasp and staple, safety type, size 100mm, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws, complete all as specified and as directed by Engineer-In-Charge.
Floor door stopper of cover plate 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed by Engineer-In-Charge.
MS 100mm long butt hinges medium weight, complete all as specified and as directed.
Curtain rod, 20mm dia, mild steel, fancy type, any colour coated, pvc layered with fixing and including end knobs, fixing brackets, stops, round rings to hold the curtain, fixing in repairs with wall plugs and screws, complete all as specified and as directed by Engineer-In-Charge.
GI wire of 6mm dia including fixing with staining bolts nd nuts with hook and ncessary PCC work in M-10, Nominal Mix type C-1 (1:3:6) using 20mm graded crushed stone aggregate, and necessary form work for mosquito net equal to length of barrack and 04 Nos line in each barrack, complete all as specified and as directed by Engineer-In-Charge.
Galvanised, 2-strand, steel barbed wire 2.24mm dia barbed with 2.0 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and as directed by Engineer-In-Charge.
Mild steel galvanised concertina coil fencing with punched tape concertina coil 610 mm dia, 10 metre openable length (total length 90 mtrs), having 50 Nos. rounds per 6.0 metre length, spring core wire (2.5 mm dia galvanised wire) of high tensile strength not less than 400-450 gm/ Sqmm with tape (0.52mm thick) and weight 1.35 Kg/metre and fixing the same with existing Y-shaped angle iron placed 2.0mtrs apart and with 6 horizontal R.B.T. (Reinforced Barbed Tape) wire, stud tied with G.I. staple sand, 125 to 127 Nos. of G.I. clips in one coil, to retain horizontal, including necessary nuts and bolts, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 71.00 here-in-before but except bricks .
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engineer-In-Charge.
M&L rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surface finished even and smooth without using extra cement complete all as specified and directed
Rendering 15mm thick, on any surface of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing compound shall deemed to be included in quoted rates.
Rendering 5mm thick on any type of surfaces, on ceiling, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of cement paint, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening, preparatory to distempering, after making surface smooth with 3mm thick birla white wall care putty, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated, un-decorated, plastered or unplastered surfaces of walls including complete removal of existing treatment, making surface even and filling weather proof putty in small holes, cavaties, cracks and applying two coats of distemper oil emulsion over one coat of chalk whiting, preparatory to distempering, complete all as specified and as directed by Engineer-In-Charge.
M&L for applying two coats of cement base paint over a coat of primer on newly plastered surfaces of walls including preparation of new surfaces complete all as specified and directed.
Preparation of old/ decorated, un-decorated, plastered or unplastered surfaces of walls including complete removal of existing treatment, making surface even and filling weather proof putty in small holes, cavaties, cracks and applying two coats of cement paint , complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
M &L for preparation of old surfaces of ceiling, plastered or unplastered including brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on ceiling complete all as specified and directed
Preparation of old/ decorated, un-decorated, plastered or unplastered surfaces of roof fascias and projections, chajjas etc including complete removal of existing treatment and applying two coats of exterior emulsion (Apex paint), complete all as specified and as directed by Engineer-In-Charge.
Dismantling/ taking out of cast iron drain pipes of 100mm bore (of any specifications), as fixed on walls or laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
Dismantling/ taking out of cast iron drain pipes of 75mm bore (of any specifications), as fixed on walls or laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 100mm bore, in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 100mm bore, in any length with or without ears, with cement joints, lfixed on walls, complete all as specified and directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 75mm bore, in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 75mm bore, in any length with or without ears, with cement joints, fixed on walls, complete all as specified and directed by Engineer-In-Charge.
Cast iron bends, 100mm bore pipe (any radius), with duck's foot or heel rest, complete all as specified and as directed by Engineer-In-Charge.
Cast iron bends, 75mm bore pipe (any radius), with duck's foot or heel rest, complete all as specified and as directed by Engineer-In-Charge.
Cast iron branch pieces, 100mm bore pipe, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-In-Charge.
Cast iron branch pieces, 75mm bore pipe, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-In-Charge.
Cast iron bends, 100mm bore pipe (any radius), diminishing pieces or tapers (larger bore measured), fitted with oval access doors, complete all as specified and as directed by Engineer-In-Charge.
Cast iron bends, 75mm bore pipe (any radius), diminishing pieces or tapers (larger bore measured), fitted with oval access doors, complete all as specified and as directed by Engineer-In-Charge.
Cast iron branch pieces, 100mm bore pipe, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-In-Charge.
Cast iron ‘P’ or ‘S’ trap, with grating of 100mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Cast iron floor trap, with grating of 100mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Salt-glazed stoneware gully traps, size 150x100mm, square or round mouthed, type 'P' including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, omplete all as specified and directed.
M&L Hard core of broken stone boulders of gauge n exc 63 mm, deposited spread and leveled in layers n exc 15 cm thick, watered and rammed to true surface complete all as specified and directed. Note :Thickness shall not exceed from 100mm thick.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over and including 30mm thick well rammed sand cushion laid over and including sub base of 100mm thick of plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge.
Chequered cement concrete pre-laminated coloured tiles size 300mmx300mmx20/25mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 20mm thick screed bed or bedding layer in cement mortar 1:6 laid over and including 75mm thick sub base of Nominal Mix PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate, complete all as specified and as directed by Engineer-In-Charge.
Precast reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engineer-In-Charge.
S&F mild steel work as in posts and struts in 'Y' shape in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer-In-Charge.
Excavation in trenches n exc 1.5 metre wide & n. exc 1.5 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n. exc 1.5 metre in depth and getting out in any type of soil, complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
M&L Cement concrete M-15, type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary form work, all as specified.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of 150mm internal dia, set in cement mortar, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.
Salt-glazed stoneware drain pipes, internal 150mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Cleaning of blocked/ choked SGSW/ Cast Iron drain pipes/ sewer lines of any dia and any types, in horizontal or vertical position by rodding, from manholes to manholes and manholes end to septic tanks/ soakage wells, flushing with pressure jet of water/ sewage suction machine after taking out existing manholes covers and putting back manhole covers in original position after cleaning of lines including removing the sludge and other waste materials/ blockage in drain pipes, transport to outside of Unit/ Cantonment area and spreading bleaching powder on top of manholes covers of septic/ soakage pits or in the surrounding areas to make hygienically fit, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of transportation of waste materials shall be deemed included in quoted rates.
Construction of Septic Tank 50 user, excavation in any type of soil, foundation PCC, brick work in CM 1:4 , RCC/CI man hole covers, Vent shaft and sludge chambers etc complete all as specified and shown in drg directed by Engr-in-Charge. Drg No CESZ/TD-01/2015 Sheet 1/3, 2/3
Construction of soakage well of 1.2 mtrs dia and 3.0 mtrs in depth, in any type of soil including plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregates) in foundation and honeycombed brick masonry in cement mortar 1:4 and reinforced cement concrete cover slab, M-25, type A-1 (using 20mm graded crushed stone aggregates), complete all as specified and as shown in drawing. Drawing No- CE/TD/1202/03 sheet 1/2 and 2/2 dated 09.10.03 revised 14.10.14 and 11.05.07.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 124.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 124.00 here in before but for one 3-pin socket outlet 5-Amps on the independent board.
Description all as per serial item No- 124.00 here-in-before but for one light point controlled by two way switches.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheeathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Modular stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Modular switch piano, single pole, one way, 5/10 Amps, 1/2 module complete all as specified and as directed by Engineer-In-Charge.
Modular switch piano, single pole, two way, 5/10 Amps, 1/2 module complete all as specified and as directed by Engineer-In-Charge.
Modular switch 1 way 16A, 1/2 module 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Shuttered Socket outlet modular type, 6A -5 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Shuttered Socket outlet modular type, 6/16A -6 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of LED Bed/night light fitting spot type with reflector 3 watt with driver suitable for wall mounting and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells / Crompton / Bajaj
S&F in replacement of LED retrofit lamp, capacity 9 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm/ white light, complete all as specified and as directed by Engineer-In-Charge. Make: Havells/ Compact/ Philips/ Osram.
S&F in replacement of LED tube light fitting, 18 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp 18 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- E-Lite LED Pride Plus Neo LHEXBTP7IN1W018/ Crompton cat part LCTL-18-CDL/ Bajaj product code-12410, luminaire type- BCLSB 18 NW.
S&F in replacement of MCB, Single Pole and Neutral, 40-63 Amps (up to), 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Sheet metal enclosures for Triple Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged MCCB with new MCCB, triple pole, 415 Volts, adjustable thermal and fixed magnetic setting, 63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA066805R1 or equivalent in in L&T/ Legrand/ Merlin Gerin/ Siemens.
S&F in replacement of LED security/ street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection, including LED lamps of 30 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified. Make: Havells cat part No- Endura Citylite Platinum Plus SL30WLED757SASYBOPC/ Bajaj ordering code No- 169907 (Product Code- BRLEP 30W LED WH)/ Philips ordering code No- 910925452299 (Product Code- 871869632003700).
S&F in replacement of Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Ceiling fan, mettalic, sweep 1200mm, superior rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers and connectig wire of suitable size and length, complete all as specified and as directed. Make: Havells cat part No- FHCES5SWHT48/ Crompton Greaves Entrust 50/ Usha Ergo/ Bajaj Electra 50/ Orient Electric energy star Note: Old Ceiling fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt..
S&F in replacement of Exhaust fan, mettalic, sweep 380mm, double ball bearings, star rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including fixing accessories i.e. long bolts with nuts, rubber pad and washers and connectig wire of suitable size and length, complete all as specified and as directed by Engineer-In-Charge. Make: Havells model No- TURBOFORCE/ Crompton Greaves/ Usha/ Bajaj/ Orient. Note: Old Exhaust fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt..
S&F in replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 4.0-core, from existing pole to bldg or passing through pipes like PVC conduit 25mm dia including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge. Note : Cost of PVC conduit shall deem to be included in the quoted rates.
S&F in replacement of earthing complete as per electrical plate No 5 of MES SSR Part-I with galavanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including galvanised earth lead wire 4.0mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing lead shall be protected by galvanised iron or steel pipe 20mm bore light grade and connected to continuous earth wire on pole/test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcol, salt, funnel PCC pit and RCC cover complete all as specified & tested complete all as specified. Note : 1. Following items deemed to bed included in quoted rate (a) Earth electrode (b) Main earth lead from earth electrode to test point and further to equipment to be earthed upto 7.5 Mtr (c) M&L for connecting earth electrode and earth lead as specified (d) Adequate qty of charcol, dust and common salt as per direction. (e) All labour involved incl testing of earth network (f) Excavation and earth work or drilling hole for electrode (g) PCC pit and CI cover (h) Funnel with wtering pipe, wiremesh and copper lugs etc as specified (j) GI protection pipe of size as specified for protection of earth lead from mechanical injury or tempring. 2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Amount of Schedule of credit of for Rs 80238.00 shall be deducted from quoted amount.
CHOPRA CONSTRUCTIONS
M/S KARAN SINGH CONTRACTOR
M/S Mahajan Construction Co.
M/s Joginder Lal Malhotra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .