Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 CrAccepted-AOC | ₹11.1 Cr | L1 | Accepted-AOC LOWEST RATE QUOTED BIDDER |
| 2 | L2₹11.4 CrRejected-Finance | ₹11.4 Cr | L2 | Rejected-Finance 2nd lowest rated quoted bidder |
Tender Value
Refer Docs
EMD Value
₹5.3 L
Closing Date
17 May 2023, 5:30 pmClosed
Superintending Engineer PMGSY Konkan Region Thane
1st floor in PWD compound, Near Talavpali, Opp. Zilla Parishad, Station road, Thane (W) 400601
ADBRAT(II)08 Three Roads in Block and Dist Ratnagiri
2023_MMGSY_899295_8
08/2023-24/ADB/KON/RATNAGIRI
Open Tender
Civil Works - Roads
547 days
RATNAGIRI
Please refer Tender documents.
7 documents required · 7 mandatory
₹29,500
₹5.3 L
17 Feb 2024
2 May 2023
18 May 2023
2 May 2023
17 May 2023
10 May 2023
2 May 2023 - 9 May 2023
Amount
1.00 Upgradation and Maintenance of Road Lajul to Boudhwadi Narabe-Govalkarwadi Road. Km. 0.00 to 6.70 Km. Tal-Ratnagiri, Dist - Ratnagiri.
Site Clearance and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leads as per Technical Specification MORD 2014 Clause 302.3.5
Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Scarifying the existing Bituminous surface to a depth of 150 mm and disposal of scarified material with a lift up to 3 m and lead upto 1000 m as per technical specificationa Clause 301.4
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading II material by mix in Place Method
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density WBM Grading 2 as per Technical Specification Clause 405. For - By Mechanical Means
Modified Penetration Macadam- Providing and laying bitiminous macadam using crushed agrregates of Grading 2, premix with bituminous binder, transported to site with VTS, Laid over a previously prepared surface, finished to the required grade, level, alighnment, and rolling to achieve the desired compaction for 5075mm compacted thickness with 3.3% VG30 bitumen. USING 80TPH Batch mix type hot mix plant with SCADA, Sensor paver Item rate as per DSR 17-18 Pag.no-23
Tack Coat -Providing and applying tack coat with Bitumen emulsion (Rapid Setting-1) using emulsion distributor at the rate of 0.20 to 0.25 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503
20mm thick Open-Graded Premix Carpet using S 65 (penetration grade/modified bitumen) Binder Bitumen(S-65) 60/70- (VG 30)-Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. as per Technical Specification Clause 508.SOR ITEM NO. 5.9(2) Case - II By Mechanical Means, Bitumen(S-65) - (VG 30)
Seal Coat- Providing and laying liquid seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, as per Technical Specification Clause 510 (SOR ITEM NO.5.12 / B / Case I / ( i ) By Mechanical Means, Bitumen(S-65) - (VG 30)
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to 900mm dia. Hume pipe
Laying Reinforced Cement Concrete Pipe NP2 as per design in single row 600 MM to 900 MM Dia- Reusable 600 to 900mm dia. Hume pipe
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil By Mechanical means
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.(SOR ITEM NO. 11.1 ) Hard rock (blasting prohibited)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)
Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5)
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1200 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)"
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Providing dry rubble latrite stone masonary with available material. (lead 50 mt)
Providing dry rubble latrite stone masonary ( including royalty ) (lead 50 mt)
Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade 5 th kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 5th Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)
Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and washing complete Spec. No.: MORTH 807
Providing and fixing Retro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A
(Village Name Board) Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting 900 x 600 milimeter reclangular
MMGSY/PMGSY Citizen's information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed
Providing and laying reinforced cement concrete pipe NP2 for wasti approches on bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, PWD Spec. NP2 - NP-2 - 450 mm For Irrigation pipe crossing
Providing and laying reinforced cement concrete pipe NP2 for wasti approches on bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, PWD Spec. NP2 - 600 mm For Wasti Approch
Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42
Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade
Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and painting existing board etc. complete
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.
Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.
Construction of Rounded Hump Type Speed Breaker as per IRC : 99 (1988) for general traffic as per specification, including painting, fixing cautionery boards etc. complete and as directed by Engineer-in-Charge.
Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.
2.00 Upgradation and Maintenance of Road Gavkhadi to Musalmanwadi -Nankarwadiwadi -Pawarwadi Road. Km. 0.00 to 7.400 Km. Tal-Ratnagiri, Dist - Ratnagiri.
Site Clearance and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leads as per Technical Specification MORD 2014 Clause 302.3.5
Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Scarifying the existing Bituminous surface to a depth of 150 mm and disposal of scarified material with a lift up to 3 m and lead upto 1000 m as per technical specificationa Clause 301.4
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading II material by mix in Place Method
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density WBM Grading 2 as per Technical Specification Clause 405. For - By Mechanical Means
Modified Penetration Macadam- Providing and laying bitiminous macadam using crushed agrregates of Grading 2, premix with bituminous binder, transported to site with VTS, Laid over a previously prepared surface, finished to the required grade, level, alighnment, and rolling to achieve the desired compaction for 5075mm compacted thickness with 3.3% VG30 bitumen. USING 80TPH Batch mix type hot mix plant with SCADA, Sensor paver Item rate as per DSR 17-18 Pag.no-23
Tack Coat -Providing and applying tack coat with Bitumen emulsion (Rapid Setting-1) using emulsion distributor at the rate of 0.20 to 0.25 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503
20mm thick Open-Graded Premix Carpet using S 65 (penetration grade/modified bitumen) Binder Bitumen(S-65) 60/70- (VG 30)-Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. as per Technical Specification Clause 508.SOR ITEM NO. 5.9(2) Case - II By Mechanical Means, Bitumen(S-65) - (VG 30)
Seal Coat- Providing and laying liquid seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, as per Technical Specification Clause 510 (SOR ITEM NO.5.12 / B / Case I / ( i ) By Mechanical Means, Bitumen(S-65) - (VG 30)
Thin White Topping -White topping or concrete overlay for urban roads: Construction of Thin White Topping plain cement concrete pavement of M-40 grade over a prepared sub base with 43 grade cement, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, replacing cement by fly ash to the extent of 15 per cent and sand by 10 per cent, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, construction and longitudinal joints with panel size of 1m X 1m, joint filler, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, polypropylene fiber as approved, curing compound, finishing to lines and grades as per drawing
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to 900mm dia. Hume pipe
Laying Reinforced Cement Concrete Pipe NP2 as per design in single row 600 MM to 900 MM Dia- Reusable 600 to 900mm dia. Hume pipe
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil By Mechanical means
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.(SOR ITEM NO. 11.1 ) Hard rock (blasting prohibited)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)
Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5)
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)"
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Providing dry rubble stone masonary with available material.
Providing dry rubble latrite stone masonary (with new material)
Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding
Backfilling behind abutment, wing wall and return wall with Granular Material complete as per drawings & technical specification Clause 1204.3.8
Providing and laying cement concrete wearing course M 30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Dewatering including diversion of streame providing coffer dam bunds etc as may be necessary for foundation and other parts of the work and bailling out water during and after excavation required- for abutment
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. II. P.C.C. grade M 20 (i) Nominal mix (1:1:5:3)
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. II. R.C.C M 25
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing Tar paper bearing of approved quality in proper size etc. complete (Rate as per PWD CSR 2020-21) BR Item no.13.02 Pg no 118
Expansion joint with 25 mm thich bitumenous pad / Compressible Rubber Pad (Rate as per PWD CSR for 2018-19) BR 43B Item no.14.33 pg no.123
Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete.
Drainage spouts complete as per drawing and technical specifications Clause 1209
Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x50) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2
Diversion for bridge
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade 5 th kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 5th Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)
Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and washing complete Spec. No.: MORTH 807
Providing and fixing Retro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A
(Village Name Board) Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting 900 x 600 milimeter reclangular
MMGSY/PMGSY Citizen's information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed
Providing and laying reinforced cement concrete pipe NP2 for wasti approches on bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, PWD Spec. NP2 - NP-2 - 450 mm For Irrigation pipe crossing
Providing and laying reinforced cement concrete pipe NP2 for wasti approches on bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, PWD Spec. NP2 - 600 mm For Wasti Approch
Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42
Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade
Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and painting existing board etc. complete
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.
Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.
Construction of Rounded Hump Type Speed Breaker as per IRC : 99 (1988) for general traffic as per specification, including painting, fixing cautionery boards etc. complete and as directed by Engineer-in-Charge.
Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.
3.00 Upgradation and Maintenance of Road From Kolambe School No.1 to Madhala Wathar-Warcha Vathar-Mandavkarwadi Road. Km. 0.00 to 4.300Km. Tal-Ratnagiri, Dist - Ratnagiri.
Site Clearance and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leads as per Technical Specification MORD 2014 Clause 302.3.5
Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Scarifying the existing Bituminous surface to a depth of 150 mm and disposal of scarified material with a lift up to 3 m and lead upto 1000 m as per technical specificationa Clause 301.4
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading II material by mix in Place Method
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density WBM Grading 2 as per Technical Specification Clause 405. For - By Mechanical Means
Modified Penetration Macadam- Providing and laying bitiminous macadam using crushed agrregates of Grading 2, premix with bituminous binder, transported to site with VTS, Laid over a previously prepared surface, finished to the required grade, level, alighnment, and rolling to achieve the desired compaction for 5075mm compacted thickness with 3.3% VG30 bitumen. USING 80TPH Batch mix type hot mix plant with SCADA, Sensor paver Item rate as per DSR 17-18 Pag.no-23
Tack Coat -Providing and applying tack coat with Bitumen emulsion (Rapid Setting-1) using emulsion distributor at the rate of 0.20 to 0.25 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503
20mm thick Open-Graded Premix Carpet using S 65 (penetration grade/modified bitumen) Binder Bitumen(S-65) 60/70- (VG 30)-Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. as per Technical Specification Clause 508.SOR ITEM NO. 5.9(2) Case - II By Mechanical Means, Bitumen(S-65) - (VG 30)
Seal Coat- Providing and laying liquid seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, as per Technical Specification Clause 510 (SOR ITEM NO.5.12 / B / Case I / ( i ) By Mechanical Means, Bitumen(S-65) - (VG 30)
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to 900mm dia. Hume pipe
Laying Reinforced Cement Concrete Pipe NP2 as per design in single row 600 MM to 900 MM Dia- Reusable 600 to 900mm dia. Hume pipe
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil By Mechanical means
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.(SOR ITEM NO. 11.1 ) Hard rock (blasting prohibited)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)
Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5)
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)"
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Providing dry rubble stone masonary with available material.
Providing dry rubble latrite stone masonary (with new material)
Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)
Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and washing complete Spec. No.: MORTH 807
Providing and fixing Retro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A
(Village Name Board) Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting 900 x 600 milimeter reclangular
MMGSY/PMGSY Citizen's information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed
Providing and laying reinforced cement concrete pipe NP2 for wasti approches on bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, PWD Spec. NP2 - NP-2 - 450 mm For Irrigation pipe crossing
Providing and laying reinforced cement concrete pipe NP2 for wasti approches on bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, PWD Spec. NP2 - 600 mm For Wasti Approch
Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42
Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade
Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and painting existing board etc. complete
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.
Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.
Construction of Rounded Hump Type Speed Breaker as per IRC : 99 (1988) for general traffic as per specification, including painting, fixing cautionery boards etc. complete and as directed by Engineer-in-Charge.
Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.
A.M.SWAMY CONSTRUCTIONS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid