| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹39.5 L+₹1.7 L (4.48%)Rejected-Finance | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹39.7 L+₹1.9 L (4.96%)Rejected-Finance 23 8 SANJAY COLONY AKHNOOR 181201 JAMMU KASHMIR | AKHNOOR | JAMMU | JAMMU KASHMIR | 181201 | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 4 | L4₹39.9 L+₹2.1 L (5.67%)Rejected-Finance | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 5 | L5₹41.3 L+₹3.5 L (9.19%)Rejected-Finance | L5 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
29 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR, C/O 56APO
ADDN/ALT TO CERTAIN OTM BUILDINGS WITH PRE-PAINTED GALVALUME SHEET IN LIEU OF AC ROOF SHEETING ALONG WITH ALLIED WORKS IN THE AOR OF AGE B/R-I AT AKHNOOR UNDER GE (SOUTH) AKHNOOR.
2023_MES_599498_1
GES/AKH-10/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY a(i)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹87,200
29 Aug 2023
30 May 2023
1 Jul 2023
30 May 2023
29 Jun 2023
16 Jun 2023
Amount
Rendering 15mm thick, on any surface of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-In-Charge. Note: Cost of Water proofing compound shall be deemed included in quoted rate.
M&L for applying two coats of cement base paint on newly plastered surfaces of walls including preparation of new surfaces complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening, preparatory to distempering, after making surface smooth with 3mm thick birla white wall care putty, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
GI wire of 6mm dia including fixing with staining bolts nd nuts with hook and ncessary PCC work in M-10, Nominal Mix type C-1 (1:3:6) using 20mm graded crushed stone aggregate, and necessary form work for mosquito net equal to length of barrack and 04 Nos line in each barrack, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed.
Cutting holes in brick walls , Superficial area n exc 150 sqcm built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, complete all as specified and as directed by Engineer-In-Charge.
Dismantling framed steel truss of size not exceeding 10m in span, complete all as specified and as directed by Engineer-In-Charge.
Dismantling timber scantlings 40 Sqcm and over in section, in any position, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of unframed timber scantling under 40 Sqcm, fixed in any position in fillet rails, posts rafters purlin etc complete all as specified and directed.
Rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, conforming to Fe 410-W (Gde- E- 250) quality-A, complete all as specified and as directed by Engineer-In-Charge.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 22.50cm but not exceeding 30.0cm long, dia of neck 5 to 10mm, complete all as specified and as directed by Engineer-In-Charge.
Mild steel work in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting including securing bolts; and similar work conforming to Fe 410-W (Gde- E- 250) quality-A,, complete all as specified and as directed by Engineer-In-Charge.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-In-Charge.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed by Engineer-In-Charge.
S&F Anodised aluminium snap grid frame work for false ceiling, powder coated, comprising of aluminium Tee (weight of section not less than 280 gms/mtr) and aluminium angle (weight of section not less than 280 gms/mtr), grid size 605x605mm, including Hangers 6.0mm dia, galvanised iron (upto1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3 mm size 60mm long and expansion hold fasteners 12.50mm dia, 40mm long and Providing and fixing non asbestos designer ceiling building board of 4mm thick fixed as per manufacturer’s instructions, fixed with frame work (any type) or on snap grid as in ceiling flat or sloping, complete all as specified and as directed by Engineer-In-Charge.
Reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in Slab supported on walls, lintel, chajja, beams, columns, balconies , canopies, deck slab, landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009) including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-In-Charge.
M&L Cement concrete M-15, type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, Krebs , water troughs and the like including weathering, slightly rounded or chamfered angles and throttling and necessary form work, all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 23.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 23.00 here in before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheeathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination, 2-in-1, 3-pin, 5 and 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 5-pin, 5 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of LED retrofit lamp, capacity 9 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm/ white light, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of 4 feet highly engineered plastic body with polycarbonate housing & integrated electronic driver suitable with fully diffused diffuser for general lighting in areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 20 Watts. The electronic driver used shall have a power factor >0.95 and THD <20% with 4 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make: Havells model No LUMILINE , cat part No- LUMILINEBS20WLED840SPCWH/ Or Equivalent Makes in Crompton/Philips/Wipro
S&F in replacement of Inverter LED Batten with opal diffuser, IP20, battery back-up & functioning as per product TDS, 20 Watt, complete with all accessories with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Havells cat part No- PRIDE PLUS INVERTER BATTEN LHEXACP7FN1W020 or Equivalent Makes in Crompton/Philips
S&F in replacement of SITC of high-quality integrated LED Street Light with a minimum system lumen of 4950 Lm and system wattage not exceeding 45W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70, New generation energy saving and environmental friendly long life LED street light made up of pressure die-cast aluminium housing with high efficiency LED as lighting source and lens with Toughned Glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07. to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified, complete all as specified. Make :Havells Model No ENDURA SUNDOWN TG, cat part No ENDURASUNDOWNSL45WLED765PASYBOTG or Equivalent makes in Wipro/Philips.
Taking down Existing Ceiling Fan of any size, dismantling the fan blades for smooth deposition to MES Store Yard before repair works is undertaken in the building, including taking down old existing ceiling fan hook , down rod and re-fixing/hanging the existing ceiling fan (already deposited in MES store yard) of any sweep and connecting up incl provn of cable from ceiling rose or connector to fan replace with new ceiling fan hook made out of MS flat of size 20x6mm suitable for existing channel for fixing, down rod of 2 Feet long having suitable size of holes both side and nut & bolts with two nos washers and clips, incl taking down of existing ceiling fan, complete all as specified, complete all as specified. Note : (i ) Cost of transporting the fans from building/existing location to MES store yard and taking back for re-fixing shall be deemed to have been included in the unit quoted rates.
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of MCB, Single Pole and Neutral, 6-32 Amps (up to), 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Sub main wiring (concealed conduits to surfaces) in replacement of for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Amount of Schedule of credit of for Rs 2,82,730.00 shall be deducted from quoted amount.
KRISHNA BUILDERS
M/s Sekinder Paul Sharma
M/S Mahajan Construction Co.
M/s Vishwakarma Enterprises
M/s Rajesh Kumar Contractor
RAVI KUMAR
M/s Joginder Lal Malhotra
M/S KARAN SINGH CONTRACTOR
bushan kumar
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .