Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-Finance UDAIPUR GOMATI GOMATI TRIPURA 799120 | GOMATI | TRIPURA | 799120 | L1 | Accepted-Finance Lowest | |
| 2 | L2₹20.5 L+₹1.2 L (6.23%)Rejected-Finance | L2 | Rejected-Finance Second lowest |
Tender Value
₹19.3 L
EMD Value
₹38,575
Closing Date
10 Feb 2023, 12:00 pmClosed
Executive Engineer (Elect)
Block No. 10 HQ DG BSF CGO Complex New Delhi
Improvement Up-gradation of Offices of PAD at 2nd floor Pushpa Bhawan New Delhi SH Electrification Phase II
2023_BSF_738614_1
10/NIT/ENGG/ELECT/2022-23
Open Tender
Electrical Works
Works
120 days
Executive Engineer (Elect) Block No. 10 HQ DG BSF
As per NIT
8 documents required · 8 mandatory
₹0
₹38,575
11 Apr 2023
3 Feb 2023
13 Feb 2023
3 Feb 2023
10 Feb 2023
3 Feb 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Group C)
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Group C)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make Havells/Finolex/KEI
3 x 1.5 sq. mm
3 x 4 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recess steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of 25 mm size of steel conduit along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Telephone socket outlet
Blanking plate
RJ 45 Computer jack with shutter
32 A DP one way switch
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. Make Anchor Roma/Great White/Legrand
1 or 2 Module (75 mm x 75 mm)
3 module (100 mm x 75 mm)
6 Module (200 mm x 75 mm)
8 Module (125 mm x 125 mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. Make Anchor Roma/Great White/Legrand
1 or 2 Module
8 Module
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin 5 amps ceiling rose on the existing junction box/ wooden block including connection etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
Supplying and fixing 16 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Make Havells/Simens/Legrand/L&T/ABB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make Havells/Standard/C&S/L&T/ABB
Single pole
Double pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams or truss during laying, including painting the exposed portion of loop, all as per standard design complete as required.
Supplying and fixing extra conduit down road 20 cm length G.I. pipe 15 mm dia, heavy guage including painting etc. as required. (Note more than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying, installation, testing and commissioning of 1200 mm sweep ceiling fan including nut, bolts etc. complete as required. Model Pacer Havells make or equivalent to Bajaj/CG/USHA
Providing and fixing of 2' x 2' LED slim light panel square shape along with driver ceilling mounting, recessed type, 34/36 watt 6000 K, complete with connection, testing etc. as required. Model No. Venus Neo 2X2 Havells make or equivalent to Bajaj/CG/Philips
Supplying, installation of 250 mm fresh air/ ventilating fan plastic body with louvers/ shutters complete with frame in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Model No. Ventil Air - DX White Havells make or equivalent to Bajaj/CG/USHA
Dismantling and installation of 2.0/1.5 Ton split/ window air conditioner (AC) including fixing the outdoor unit, indoor unit etc. complete as required.
Gas charging with suitable refrigerant for 1.5/2.0 Ton split/ window type air conditioners of any make.
Supplying and installation of 2.0 Ton inverter cassette air conditioner with copper condenser tube of both outdoor and indoor units including testing etc. complete as required. Model No. FCVF71A Daikin make or it's equivalent to Hitachi/ O-general/Voltas/LG/LLOYD/Bluestar
Supplying and fixing of powder coated M.S. stand suitable for outdoor unit of 1.5/2.0 Ton cassette/ split air conditioner complete with nut, bolts and washers etc. as required.
Providing and fixing inner outer copper tube pipe suitable size including insulation, testing, making connections etc. complete as required.
Providing and fixing of 20 mm PVC drain pipe for indoor unit of air conditioner including testing, connections etc. complete as required.
Supplying and fixing of one number PVC insulated and PVC sheathed/ XLPE, galvanised steel strip armoured aluminium power under ground cable of 1.1 KV grade of 3.5 x 50 sq. mm size on wall/surface/in pole as required. (Havells make or its equivalent to KEI/HPL/Polycab make)
Supplying and fixing 4 pole, 100 Amp, 415 V, 50 Hz, 18 kA braking capacity MCCB suitable for inductive load in the existing vertical type TPN MCB DB complete with connections, testing and commissioning etc. as required. (Model : DU100D, Cat. No. CM90518OOKO of L&T make or its equivalent to Simens/Schnidner/Havells make)
M/s SHAKTI ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .