Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.2 L+₹1.8 L (8.89%)Rejected-Finance | L2 | Rejected-Finance Not being L1 |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
22 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (MES) Faizabad
Garrison Engineer Military Engineer Services Faizabad PIN-224001
PROVN OF CERTAIN SANCTIONED WORKS INCLUDING MINOR WORKS AT FAIZABAD CANTT UNDER GE FAIZABAD
2022_MES_547639_1
8330/E8
Open Tender
Civil Works
Item Rate
180 days
Faizabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Faizabad
₹49,000
Yes
7 Nov 2022
25 Aug 2022
24 Sept 2022
26 Aug 2022
22 Sept 2022
9 Sept 2022
Amount
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, trenches for laying of cables or pipes, foundation for poles, stays and the like and getting out in soft/loose soil complete as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregsate) as in foundation, filling and mass concrete complete all as speicicfed and directed.
Use & waste form work to sides of concrete foundations, footings, plinth beams, bases of columns etc, vertical or to batter for rough finished flat concrete surfaces complete all as specified and directed.
Use & waste form work to sides and soffit of floor or roof beam, beam haunchings, girders, bressummers lintels, cantilevers, shellves including supports, overhangings etc, also splays between floor and beam for fair finished flat concrete surfaces complete all as specified and directed.
S&F TMT steel bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends etc and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F TMT steel bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends etc and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for RCC (1:2:4) type B1 (using 20mm graded graded crushed stone aggregate) as in slabs supported on walls, beams and colums in floors, roofs, landings, deck slabs and shelves and the like complete all as specified and directed.
M&L for brick work with old size sub class 'B' bricks in cement mortar (1:6), straight or curved on plan to any radius complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20 - 25 mm thick, laid over and including 15mm thick cement screed base in cement mortar (1:6) in flooring, set and jointed with grey cement slurry and pointed in neat grey cement mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 18-20 mm thick, laid over and including 10mm thick screed base in cement mortar (1:4) in vertical surfaces as in risers of steps, skirting, dado and pillar, set and jointed in neat grey cement slurry and pointed in grey cement mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed.
S&F mild steel work as in framed brackets of angles or tees with web and flanges cut to shape, drilled & countersunk for screw including bending & welding angles as necessary, gusket plates, riveting etc, brackets n.exc 10 Kg each (brackets over 10 Kg each to be measured under 'structural steel') conforming to Fe.290Gde-E-165 complete complete all as specified and directed.
S&F rolled steel sections as in main & cross beams, hip & jack rafters, purlins where connected to common rafters & running rails & guides for sliding doors, fixed with angles cleats or other connecting plates conforming to Fe-410-W (Gde E-250) Quality A complete all as specified and directed.
M&L for rolled steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, Tee, Angle, Channel or Flat section) including distance pieces, cleats etc,conforming to Fe 410-W-(Gde-E-250) Quality A complete all as specified and directed.
S&F mild steel work as in hand rails, half round or other steel section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc.and similar works conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F mild steel framed work as in such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks & similar work con-forming to Fe.290.Gde-E-165 complete complete all as specified and directed.
S&F mild steel wiork as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed
S&F mild steel screw bolts 5 to 10mm dia and length of shank exc 5 cm but n.exc 10 cm (machine made) with hexagonal screw heads at one end & screwed the other or screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa, fixed with self tapping screws as in roof covering /cladding to wall, complete all as specified and directed.
M&L for preparation of new steel & iron surfaces of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer over complete as specified and directed.
M&L for hardcore of broken bricks or boulders of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surfaces complete as specified and directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection / hard standing etc, laid in panels, finishing the cement concrete surface even and smooth without using extra cement complete as specified and directed.
M&L for forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade A complete all as specified and directed.
M&L for brick work with old size fly ash bricks in cement mortar (1:6), straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for non - skid ceramiccoloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, laid over and including 15mm thick screed bed or bedding layyer in cement mortar (1:6) as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles all as specified and directed.
M&L for glazed ceremic coloured tiles of size 350x250x7mm/ 450x350x7mm thick, laid over and including 10mm thick rendering coat/ screed bed in vertical surfaces as in dado, skirting and the like, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
S&F in repair, 125mm size brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-Charge
S&F 15 mm dia boe GI tubing, medium grade with all fittings, laid in floors or fixed to walls complete all as specified and directed.
S&F 20 mm dia boe GI tubing, medium grade with all fittings, laid in floors or fixed to walls complete all as specified and directed.
S&F 15mm dia bore bib taps, cromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F 15mm dia bore angle stop valve, cast copper alloy, screwed down high pressure with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F 15mm dia bore pillar tap with long screwed shank and fly nut, fancy type, cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered hot or cold screwed for iron pipe and fixed complete all as specified and directed.
S&F PVC connection 15mm bore 450mm long hexagonal brass chromium plated nuts and washers on both sides complete as specified and directed
S&F for 10 Ltrs PVC valveless, syphonic action type low level flushing cistern, white with inlet, ball valve, float, handle, flush pipe including brackets complete all as specified and directed.
S&F 20mm bore Gun- metal globe or gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F brass chromium plated tubular towel rail with hook, 20 mm dia, D type, 60 cm long between flanges and fixed to wall complete all as specified and directed.
S&F in repair, glass shelf / corner glass diplomat assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
S&F vitreous china urinal, half stall type, white with and including urine spreader and 32/40mm dia 90cm long PVC waste down pipe complete all as specified and directed.
S&F in repair, vitreous china wash down water closet pan 'pedestal pattern', white (excluding fixing bolts, flushing cisterned and flush pipe) complete all as specified.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and the like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for preparation of old plastered, decorated or undecorated surfaces of walls and applying two or more coats of textured exterior paint of approved shade @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm complete all as specified and directed.
M&L for preparation of old plastered, decorated or undecorated surfaces of ceiling and applying two or more coats of textured exterior paint of approved shade @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm complete all as specified and directed.
S&F in repair, 15mm dia bore chromium plated, fancy type, single Lever basin mixer without popup waste with 450mm long braided hoses of standard quality for mixing hot & cold water with all fittings etc complete all as specified and directed. Make : Jaguar ORP-10011BPM or equivalent as approved by GE
S&F in repair, 15mm dia bore chromium plated, fancy type, single lever wall mixture 3 in 1 System with provision for both Hand shower and Overhead shower with 115mm long bend pipe, connecting legs & wall flange (without Hand & Overhead Shower) of standard quality including all necessary fittings etc complete all as specified and directed. Make: Jaguar ORP-10125PM or equivalent as approved by GE
S&F 180 mm dia round shape chromium plated over head shower (OHS) single flow (ABC body, chromium plated with grey face plate) with rubit cleaning system shower including all necessary fittings as per manufacturer's instructions complete all as specified and directed. Make : Jaguar OHS -1759 or equivalent as approved by GE
S&F in repair, Rimless Single piece WC with UF soft close seat cover, hinges, fixing accessories set and cistern fittings, size 390 x 710x720 mm, including connection to trap and drain complete all as specified. Make : Jaguar Model No. VGS-WHT-81853S300UF or equivalent as approved by GE
S&F for wash hand basin with PVC VANITY 24" including waste pipe, waste cupling with all fittings complete all as specified and directed . Make : Somany or equivalent as approved by GE
S&F glass encloser Cat No. JSE- CHR 81000680F22X DOOR WITH WALL GLASS HINGES with all accessories as required complete all as specified and directed by Engineer-in-Charge. Make : Jaguar OHS-CHR-1649 or equivalent as approved by GE
S&F in repair, 15 mm dia bore CP fancy type Bib Cock with wall flange, scewed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. Make : Jaguar ORP-10037PM or equivalent as approved by GE
S&F in repair, 15 mm dia bore angular stop cock with wall flange, screwed down both ends for iron pipe complete all as specified and directed. Make: Jaguar ORP-10053PM or equivalent as approved by GE
Demolition of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles from site and removing rubbish off the premises complete all as specified and directed.
M&L for joint free coloured glazed ceramic tiles of size 300 x 600 x 8mm thick in vertical surfaces as in dado/vertical services, laid over and including 10mm thick rendering/ screed bed in cement mortar (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match the surface complete all as specified.
M&L for Virified double charged light shade tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, laid over & including 15mm thick screed bed or bedding layer in cement mortar (1:6) as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
S&F in repair, stainless steel toilet paper holder fixed with wooden gutties or PVC rawl plugs and screws to wall surfaces complete all as specified and directed. Make: Prayag Cat No BA 88 or equivalent as approved by GE
S&F in repair, 15mm size PVC connection 450mm long with PTMT nuts & washers at both ends and fixed complete all as specified and directed.
S&F in repair, Health faucet with1 mtr long flexible tube including wall hook and fixed in position complete all as specified and directed. Make: Cat No BEA 85 or equivalent as approved by GE
S&F in repair, brass chromium plated towel rack and fixed to wall complete all as specified and directed. Make: Prayag Cat No. BA 02 or equivalent as approved by GE
S&F in repair, stainless steel grating 100mm, square/round with or without hole and fixed in position complete all as specified and directed.
Supplying and laying of 16 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings, laid in trenches complete all as specified and directed.
S&F in repair, 19/20 mm dia stainless steel, fancy type drapery curtain rod including fixing arrangements complete all as specified and directed by Engineer-in-Charge..
S&F in repair, set of two nos stainless steel finials (Latto) to be fixed with 19/20 mm drappery/curtain rod complete all as specified and directed.
M&L for construction of sokage well of 2.40 m dia and 3.00 m effective depth with and including excavation in any type of soil, PCC in foundation, walls of honey combed mansonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick mansonry in cement mortar, RCC cover slab in M25 /SFRC cover, interconnecting pipes of RCC/DWC complete, filled with brick bats complete all as specified, shown on drawings and directed by Engineer-in-Charge.
S&F 150mm bore reinforced concrete pipes, class NP-2, laid and jointed with collar complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) as in bed to drain pipes of 150 mm dia bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated materials (soil) at a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Removing excavated material to a distance exc 50 mtr but n.exc 250 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L precast reinforced cement concrete (1:2:4) type B-1, (using 20mm graded crushed stone aggregate) as in landing, cover slabs (for man holes) and similar articles and set in cement mortar (1:6) with joints to match complete all as specified and directed. Note:- Reinforcement shall be measured and paid for separately under respective item of Schedlue 'A'/BOQ.
S&F air cooled split unit cooling and heating type air conditioner electric driven, single phase of capacity of 2 TR, 3 star rated with connection including installation, testing and commissioning complete all as specified and directed.
S&F 4 KVA capacity Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% including installation, testing and commissioning complete all as specified and directed.
Supply, laying and testing 16 sq mm 2 core XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed.
M&L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness shall be measured & paid.
Supply & Laying old size sub class 'B' bricks locally available best quality, laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure MCB SPN DB 4 way double door, suitable for 240 Volt, fixed flush on wall including necessary cutting in walls of any description and making good disturbed surfaces to match the existing surfaces complete all as specified and directed.
S&F MCB SPN, 6 to 32 A, 230 V, 'C' curve, 10 kA, miniature circuit breaker (MCB), fixed in DB including necessary connection, testing and commissioning, complete all as specified.
S&F MCB SP, 6 to 32 A, 230 V, 'C' curve, 10 kA, miniature circuit breaker (MCB), fixed in DB including necessary connection, testing and commissioning, complete all as specified.
M&L for submain wiring of any description and M&L for sub main wiring with two runs of 4.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 Volts grade multistranded copper conductor single core cable drawn through and including PVC concealed conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4.0 Sqmm green in colour as earth continuity conductor connected to common earth dolly from main DB to Sub DB including cutting chases and making good in cement mortar (1:4) etc to match the existing surfaces complete all as specified. Note:- (i) Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs and MCBs shall be deemed included in quoted rates. (iii) Earth wire shall run inside the conduit pipe.
S&F single pole and neutral enclouser with two pin and earth plug and socket including one single pole MCB 20 Amps, 240 Volts complete all as specified and directed.
M&L for earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earthing wire 4mm dia size by means of GI bolts, nuts, check nuts and washers, earthing wire protected by GI pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) type C1 in chamber of size not less than 300x300x300mm (internal diamentions) with cover made of RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm C/C both ways and angle iron 40X40X5mm frame etc duly painted with two coats of synthetic enamel paint over a coat of red oxided primer on exposed surfaces complete all as specified and directed by Engineer-in-Charge. Note: The unit rate includes earthing wire and protection pipe upto maximum 7.5 metre from earth plate, earth point / test point.
Supply, installation, testing and commissioning of Metal Top Deep Freezer of 210 Ltrs capacity, single phase 240 Volt, 50 Hz including electric connection complete all as specified and directed.
Supply, installation, testing and commissioning ofrefrigerators, electric driven (single phase), capacity more than 320 Litres .BEE 5 star rated including electric connection complete all as specified and directed.
M&L for concealed type point wiring for 16 Amps power point on independent board with PVC insulated PVC unsheathed electric (FRLS) cable of size 2.5 Sqmm nominal cross sectional area, 1100 Volt grade, single core having multi stranded copper conductor with 1.5 Sqmm green colour PVC insulated unsheathed electric (FRLS) cable having multistranded copper conductor as earth wire connected to earth dolly by providing lugs including non-modular type GI sunken boxes suitable for non-modular switches/sockets etc with 3mm thick hylam sheet with glossy finish including necessary cutting for fixing switches, sockets, regulators etc, drawn through and including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm dia with all conduit accessories in concealed wiring system complete all as specified for the following:-
S&F switch piano flush type polycarbonate single pole one way 16 Amps complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 5 pin 6/16 Amps flush type complete all as specified and directed.
His And Her Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .