Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 6 1ST CROSS 1ST MAIN OLD POLICE STATION ROAD LAKKASANDRA BANGALORE 560 030 | BENGALURU URBAN | KARNATAKA | 560030 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹13.0 L+₹2.9 L (28.3%)Rejected-Finance | L2 | Rejected-Finance Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
26 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
WELCOME MAINTENANCE OF OFFICERS MARRIED ACCOMMADATION AT NGV KORMANGALA UNDER GE CENTRAL BANGALORE
2021_MES_439003_1
8105E
Open Tender
Civil Works
Item Rate
270 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹20,000
Yes
6 Jul 2021
28 Apr 2021
28 May 2021
28 Apr 2021
26 May 2021
12 May 2021
28 Apr 2021 - 11 May 2021
60 days
Amount
B/R PORTION:- Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegetation including roots all as specified.
M&L Rendering 10mm thick on fair faces of brick or concrete surfaces of wall in CM (1:4) finished even & smooth without using extra cement.
M&L Rendering 5mm thick on fair faces of brick or concrete surfaces of ceiling in CM (1:3) finished even & smooth without using extra cement.
M & L for preparing plastered surfaces of walls and applying two coats of distemper-oil-emulsion over a coat of primer over a coat of wall care putty (Two coats in minimum 1mm thick) complete all as specified and directed.
M & L for preparing plastered surfaces of ceilings and applying two coats of distemper-oil-emulsion over a coat of primer over a coat of wall care putty (Two coats in minimum 1mm thick) complete all as specified and directed.
M & L Preparation of Old decorated surface and applying one coat of distemper oil bound on surface of Wall complete all as specified and as directed.
All as per Item No. 6 above/here - in - before but for Ceilling.
M&L complete removal of existing treatment and applying two coats of distemper oil emulsion over a coat of primer to plastered and other surfaces including providing wall care putty two coats in minimum 1mm thick on plastered surface complete all as specified.
All as per Item No. 8 above/here - in - before but for Ceillings.
M & L Preparation of Old decorated surface and applying two coats of distemper oil bound on surface of Wall complete all as specified and as directed.
Preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M & L for grinding of existing mosaic floor surface of any type or description with admixture as directed after complete removal of stain, greasy spot etc, washing with caustic soda and finally finished the surface with wax polish by using machine complete all as directed by Eng-in-charge. Note :- (i) The grinding & polishing work shall be carried out upto seventh and further floors including skirting, staircase treads & rises. (ii) Floor/rooms for grinding or polishing will not be given in full at a time. It may be partly any number of time as and when required/ordered for which contractor shall make necessary arrangement and no extra claim on this account will be admissible. (iii) Cost elements for the above factors shall deemed to included in the item.
M & L for cleaning of existing ceramic tiles in floor & wall using acid of suitable concentration so that the tiles joints not damage, filling joints of tiles with white cement mixed with pigment to match with existing shade of tiles including at junction of wall and floor, around gratings, door frame etc and finally cleaning with dry cloth the entire area including water supply/ sanitary fitting complete all as directed and entire satisfaction of Eng-in-charge.
Preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
E/M PORTION : Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring surface type, with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC conduit (Medium grade) with all fittings and accessories (like Tee, bend etc.) complete in walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point and earth dolly including MS terminal box with 3mm thick masonic laminated sheet top cover fixed on wall with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.
All as per item No 17 above but for one 3 pin socket outlet, 5 Amps on Independent board complete all as specified and directed.
All as per item No 17 above but for one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and directed.
All as per item No. 17 here in before but wiring with cables of size 4.0 sqmm for wiring & cables of size 4.0 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed.
M & L for Point wiring surface type, with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories (like Tee, bend etc.) complete in walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point and earth dolly including PVC terminal box with 3mm thick masonic laminated sheet top cover fixed on wall with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.
All as per item No 21 above but for one 3 pin socket outlet, 5 Amps on Independent board complete all as specified and directed.
All as per item No 21 above but for one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and directed.
All as per item No. 21 here in before but wiring with cables of size 4.0 sqmm for wiring & cables of size 4.0 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed.
S & F modular switch 6 Amp, 1 module, flush type one way 230 volts complete all as specified and as directed.
S & F in repair modular switch 6 Amp, 1 module, flush type one way 230 volts complete all as specified and as directed.
S & F modular switch 16 Amp, 1 module, flush type one way 230 volts complete all as specified and as directed.
S & F in repair modular switch 16 Amp, 1 module, flush type one way 230 volts complete all as specified and as directed.
S & F modular bell push, 6 Amp, 1 module, flush type one way 230 volts complete all as specified and as directed.
S & F calling bell/door bell, electronic musical type, AC 230 volts, single pole complete all as directed.
S & F modular socket, 2/3 pin combination, 6 Amp, 2 module, flush type one way 230 volts complete all as specified and as directed.
S & F in repair modular socket, 2/3 pin combination, 6 Amp, 2 module, flush type one way 230 volts complete all as specified and as directed.
S & F modular socket 5/6 pin combination, 6/16 Amp, 2 module, flush type one way 230 volts complete all as specified and as directed.
S & F in repair modular socket 5/6 pin combination, 6/16 Amp, 2 module, flush type one way 230 volts complete all as specified and as directed.
S & F modular fan regulator 5 step high speed, 120 Watt and above, 2 module, 230 volts, ergonomically designed directional knob with 360 degree rotation , ISI marked complete all as specified and as directed.
S & F in repair modular fan regulator 5 step high speed, 120 Watt and above, 2 module, 230 volts, ergonomically designed directional knob with 360 degree rotation , ISI marked complete all as specified and as directed.
S & F in repair fan capacitor 2.5/3.15 mfd suitable for 1200/1400mm sweep ceiling fan complete all as specified and as directed.
S&F in repair LED tube light fitting of 10 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton Greaves/Bajaj
S&F in repair LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton Greaves/Bajaj
S & F in replacement/repair MCB, 'C' Series, SP, 240 Vlots, 6 to 32 Amps, 'C' Series, 10KA breaking capacity complete all as specified and directed.
S & F in replacement MCB, SPN, 240 Volts, 40/63 Amps, 'C' Series, 10KA breaking capacity complete all as specified and directed.
Supply and fix in replacement Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit (Medium grade) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note:- Two runs wiring cable with one run earth wire and PVC conduit shall be measured as one unit length/RM.
Omkar Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .