Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 CrAccepted-AOC | ₹12.0 Cr | L1 | Accepted-AOC Proposal accepted by the Government |
| 2 | L2₹12.2 CrRejected-Finance | ₹12.2 Cr | L2 | Rejected-Finance Since 2nd lowest |
Tender Value
₹10.0 Cr
EMD Value
₹20.0 L
Closing Date
18 Dec 2021, 5:30 pmClosed
Chief Electrical Engineer, Vidyut Bhavan, Panaji
Chief Electrical Engineer, Vidyut Bhavan, Panaji, North-Goa
Work of conversion of 11KV overhead network of Borim feeder to 11 KV underground system along road side from 33/11 KV Shiroda Sub Station in Shiroda Constituency.
2021_ED_1250_1
Tender No 52(21-22)
Open Tender
Electrical Works
365 days
33/11 KV Shiroda Sub Station
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,500
₹20.0 L
20 Jan 2023
15 Nov 2021
20 Dec 2021
18 Nov 2021
18 Dec 2021
18 Nov 2021
Amount
COST OF MATERIAL
RCC Hume Pipe 100mm dia with required no. of collars, for road crossing
GI Pipe 100mm, class B for nalla crossing and for cable rising on D.P. of DTC
Sand for cushioning of HT underground cables. (Dimesions 0.15x0.45x24000)
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.
Supply and erection of straight through joint for 300sq.mm cable
Supply and laying of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth sand upto depth of 0.15mts. Confirming to IS 1255 1967 at non road crossing.
Warning tape.
Providing and laying in position cement concrete 1 is to 2 is to 4 (1 cement is to 2 coarse sandis to 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations.
12mm cement plaster 1 is to4 (1 cementis to 4 fine sand) for foundations.
11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker .
11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches.
11KV, 3 core, 95sq.mm, Al conductor, XLPE, insulated, armoured cable (from the RMU to the transformer)
11KV 3 phase indoor terminating kit to be used with cables 300sq.mm.
11KV 3 phase outdoor terminating kit to be used with cables 300sq.mm.
11KV 3 phase indoor terminating kit to be used with cables 95sq.mm.
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per 95sq.mm.
Cable Route marker
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
HDGI flat of size 25mm x 5mm for earthing.
COST OF ERECTION
Earthwork in excavation by mechanical means (hydraulic excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in Hard Soil (Dimensions is to 0.9x0.45x24000) for TRENCH AND RMU
RCC Hume Pipe 100mm dia with required no. of collars, for road crossing
GI Pipe 100mm, class B for nalla crossing and for cable rising on D.P. of DTC
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.
Supply and erection of straight through joint for 300sq.mm cable
Refilling the pipeline foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions is to 0.75*.45*24000)
Disposal of earth at a distance of 3000 mts (Dimesions 01.15x 0.45 x24000)
Centering and shuttering including struttings, propping etc and removal of formwork .
11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker .
11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches.
11KV, 3 core, 95sq.mm, Al conductor, XLPE, insulated, armoured cable (from the RMU to the transformer)
11KV 3 phase indoor terminating kit to be used with cables 300sq.mm.
11KV 3 phase outdoor terminating kit to be used with cables 300sq.mm.
11KV 3 phase indoor terminating kit to be used with cables 95sq.mm.
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per 95sq.mm.
Cable Route marker
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
HDGI flat of size 25mm x 5mm for earthing.
DISMATLING OF (ALL THE DISMANTLED/ REMOVED MATERIALS TO BE HANDED OVER TO THE CONCERN SUB DIVISIONAL OFFICE.
Removal of 9mtr long RCC pole
Removal of M.S. Rail Poles 90 lb yd 13 mts
Removal of 11KV Pin Insulator with GI Pin
Removal of 11KV HDGI 11 KV V-shape X arm
Removal of HDGI X arm clamps for RCC Pole 11.00 mtr L.A SA
Removal of HDGI X arm clamps for RCC Pole 9.00 mtr L.ASA
Removal of HDGI X arm clamps for 90 lb Rail Pole LA
Removal of Top Fitting cross arm ISMC channel, 75 x 40mm, 0.7mts long.
Removal of 45KN Disc Insulators with Metal parts
Removal of Cut point Channel 1.3 Mtr long
Removal of Guard Channel 1.5 Mtr Long
Removal of ACSR conductor WEASEL
Removal of GNAT Conductor
Removal of Stay set of 9mtr long RCC pole
Aravinda Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid