Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.0 LAccepted-AOC 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L1 | Accepted-AOC LOWEST RATE | |
| 2 | L2₹65.3 L+₹1.3 L (2.01%)Rejected-Finance 6 KRIPANATH DUTTA ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹65.7 L+₹1.7 L (2.66%)Rejected-Finance 1 1 NORTH ROAD JADAVPUR KOLKATA | KOLKATA | WEST BENGAL | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹66.1 L+₹2.1 L (3.25%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
20 Jun 2022, 4:00 pmClosed
Executive Engineer, Eastern Mech. Divn., PHED
P 16 INDIA EXCHANGE PLACE EXTN CIT ANNEXE BLDG KOL 73
Providing Electro Mechanical Work for Safety Equipment at Panihati Hospital complex, Panihati under Eastern Mechanical Division, P.H.E. Dte
2022_PHED_383255_1
WBPHED/EE/EMD/NIET/04/2022-23
Open Tender
Miscellaneous Works
Item Rate
30 days
P 16 INDIA EXCHANGE PLACE EXTN CIT ANNEXE BLDG KO
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.3 L
8 Jul 2022
3 Jun 2022
22 Jun 2022
3 Jun 2022
20 Jun 2022
4 Jun 2022
Amount
PART - A
Supply ,Delivery & Storage at site of Horizontal End Suction Centrifugal Fire Pump directly coupled with suitable rated Squirrel Cage Induction Motor (IE 3) complete with Base Plate, Flexible Coupling, Coupling Guard, Companion Flange Foundation Bolt etc. having following speciification and as per Technical Specification of NIT Discharge - 2850 LPM Generated Head - 70 MWC H-Q-P curve of Pump after testing in test bed has to be supplied during delivery.
Supply ,Delivery & Storage at site of Horizontal End Suction Centrifugal Fire Pump directly coupled with suitable rated Diesel Engine complete with Base Plate, Flexible Coupling, Coupling Guard, Companion Flange, Foundation Bolt, Start/Stop Push Button, 12/24 V Battery , Fuel Tank etc. having following speciification and as per Technical Specification of NIT Discharge - 2850 LPM Generated Head - 70 MWC H-Q-P curve of Pump after testing in test bed has to be supplied during delivery.
Supply ,Delivery & Storage at site of Horizontal Centrifugal Jockey Pump directly coupled with suitable rated Squirrel Cage Induction Motor (IE 3) complete with Base Plate, Flexible Coupling, Coupling Guard, Companion Flange Foundation Bolt etc. having following speciification and as per Technical Specification of NIT Discharge - 180 LPM Generated Head - 70 MWC H-Q-P curve of Pump after testing in test bed has to be supplied during delivery.
Supply,Delivery and Storage at site 1.5 HP Monoblock Pump set (1 Working +Standby) coupled with suitable rated Motor for dewatering of Fire Pump House including supply of hose pipe, foot valve, bend, elbow required.
Supply,Delivery and Storage at site of MS Black Pipe, Heavy class ‘C’ conforming to IS : 1239/3589 including all fittings viz. elbows, tees, flanges, e.t.c. Encentric Reducer, Concentric Enlarger, Belmouth clamps, etc. as required and as per NIT
200 mm NB ( 6.35 mm thick ,Heavy Duty) - For Suction and Commom header
150 mm NB ( 5.4 mm thick,Heavy Duty ) for Delivery line
100 mm NB ( 5.4 mm thick,Heavy Duty ) for by pass line
65 mm dia ( 4.5 mm thick,Heavy Duty ) for Suction & Delivery of Jocky pump
Supply, delivery and storage at site Double Flanged Cast Iron Manually operated Rising Spindle Sluice Valve generally conforming to IS:14846 PN-1.6.and as per detail given in NIT. Test Certificate to be produced for each valve.
200 mm dia
150 mm dia
100 mm dia
65 mm dia
Supply, Delivery and Storage at site of CI doble flanged Single Door Swing Check N.R.V as per IS : 5312, Part-I, PN-1.6 and as per detail given in NIT. N.B. : Test Certificate to be produced for each valve.
150 mm dia
65 mm dia
Supply, Delivery and Storage at site Bourdon type pressure & compound gauges, 100 mm dia cast Aluminium Dial with , SS internal, DN 15 GI impulse line with three way cock.
Pressure Guages (0 - 15 kg/cm2)
Compound Guages ( +1 to -1 KSCG)
Supply delivery and storage of Anti-corrosive tape (4mm thick ).
Supply, Delivery and Storage at site 80 mm dia Cast Iron Knetic Double Orifice Air Release Valve as per relevant IS, PN-1.6.and as per detail given in NIT. :-N.B. : Test Certificate to be produced for each valve. (AT COMMON DELIVERY HEADER )
Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted 415 Volt MCC Panel having required Feeders as per specification given in NIT.
Installation of all item as mentioned in part-A including supply of all erection materials, pipe support, valve support, joint kits, clamps, cable tray etc as per IE rules to the entire satisfaction of EIC.
Supply, Delivery, Laying and Connection of Cable including supply of socket and gland as per requirement of following Al./ Cu Ar. cable in under ground trench and partly in wall(As per requirement at site) properly(GI pipe protection in concrete if required) and with brick protection on the top of the cable including filling the trench with shifted soil, leveling up and restoring surface duly rammed as per direction of EIC.
1.1 Grade, 3.5 C X 185 sq. mm XLPE Insulated Aluminium Armoured Power Cable (For Sub-station to fire pump panel).
Control cable 1.1 KV Grade 4 C X 1.5 sq mm Armoured Copper Control Cable (From PHE control Room to Fire Pump Panel).
Supply, Delivery and storage at site 1.1 KV Grade 3/31/2 core XLPE insulated Aluminium/Copper Armoured Cable as per technical specification of NIT. (For panel to fire pump motor ).
3 Core 70 Sq. mm Al. Armoured (From Panel to Fire Pump)
Power Cable 4 C X 6 sq. mm Ar,Copper (For Panel to Jocky pump ).
Power cable 3 C X 2.5 sq. mm Ar,Cu cable (For panel to dewatering pump ).
Supply, Delivery and Storage at site 1.1 KV Grade XLPE insulated Copper Control Cable as per technical specification of NIT.
2 C X 1.5 sq. mm Copper Cable (For panel to pressure switch ).
12 C X 1.5 sq. mm ,Ar. Copper Cable (For panel to Diesel Engine ).
Supply, Delivery and Storage of Pressure Switch for Auto Operation of Fire/Jockety Pump as per Technical Specification of NIT
Supply and delivery and storage of 250A MCCB,50KA fixed thermal and megnetic trip unit witrh SS enclosure
Making internal electrification of pump house consisting of 2nos. Bracket, 4 nos. light /fan pts. (1 no.T/L, bulk head 2nos. 1no. 5A plug pt. and 5* rating fan) with running earthing with 14 SWG GI wire & controlling swith of 10A 'B' series DP MCB (Havell's/L&T) with outside 2 nos. 40w LED fittings (Make - approved) incl. supply & fitting of necessary materials for work & complete connection inclu. supply of T/L set bulb etc. as per IE rules & direction.
Supply, delivery & Storage of wall mounted exhaust fan 225 mm dia 3 blade make -crompton greves
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necessary length of PVC insulated wire and making connection for exhaust of 23 cm (9")
Earthing arrangement in compliance with IE rules by GI pipe electrodes (50mm dia X 3mtr. long X 2sets) in ground & inter conection with 50 X 6 mm. GI strip with earth busbar to electrodes ramming of surface & testing compl. as per direction including connection of electrical equipments(Double) to earth busbar to be done with 25x6 mm GI strips up to the satiesfaction of EIC.
Supply & delivery of following portable fire extinguisher as per Technical Specification of NIT
ABC Powder Type Fire Extinguishers (Stored Pressure) Capacity – 4 Kgs.
Co2 Type Fire Extinguishers (Capacity – 3 Kgs.)
Commissioning of the entire installation with MCC Panel earthing etc. as per direction and entire satisfaction of EIC.
PART - B
Supply, delivery Installation, Testing & Commissioning of Microprocessor based 4 Loop fire alarm control panel (VDS & FN 54 approved) fully networkable with each loop capable of taking 125 devices display character alpha- numeric liquid crystal display the panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, provision for external & internal printer (if required), Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having 200 event memory, integral SMF lead acid batteries with sealed cells of 24Vcapable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification.
Supply, delivery, installation testing and commissioning of PA CONSOLE complete with amplifier (capacity 300 watts) microphone, 6 Hours battery backup and battery charger MS battery box & support as per direction of the Engineer-in-charge.
Supply, delivery, Installation, testing & Commissioning of Analog Addressable intelligent multisensory detector (VDS & EN 54 approved) as well as additional heat detector sensor with decentralize intelligence, soft addressable Photo thermal type as per NFPA style 7 wiring complete with base as required.
Supply, delivery, installation, Testing & Commissioning of Analogue Addressable Intelligent heat Detector (VDS & EN 54 approved) with fixed & rate of rise temperature function with decentralize intelligence, soft addressable type as per NFPA style 7 wiring complete with base as required.
Supply, delivery, Installation, Testing & Commissioning of Addressable Manual Call Point (VDS & EN 54 approved) soft addressable type as per NFPA style 7 wiring complete as required.
Supply, Installation, Testing & Commissioning of addressable Hooter (sound output of minimum 90 db) cum strobe (VDS & EN 54 approved) (Strength of light 10 cd) complete with base and as required.
Supply, Installation, testing and commissioning of SPEAKER (6w) complete with base, mounting box, gland, lugs, etc. as required completing in all respect.
Supply, Installation, Testing & Commissioning of Analogue addressable intelligent Response Indicator will all accessories complete of approved band and complete with base as required.
Supply, Installation, Testing & Commissioning of 1KVA offline UPS, pure sine wave out put on UPS (inverter) mode with 15 min battery backup back up at rated load.
Supply, delivery and laying of 20 mm PVC conduit.on wall for smoke detector wiring
Supply, erection, testing & commissioning of 2C x 1.5 mm2 Cu Control Cable.
Add: GST @ 12%
Add: LW Cess @ 1%
B T PROJECTS PRIVATE LIMITED
MACHINE SUPPLIERS SYNDICATE PVT LTD
T N BANERJEE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .