Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-Finance | ₹49.4 L | L1 | Accepted-Finance Being lowest bidder |
| 2 | L2₹50.5 LRejected-Finance | ₹50.5 L | L2 | Rejected-Finance Not become lowest bidder |
| 3 | L3₹52.0 LRejected-Finance 1 9820 GALI NO 01 WEST GORAKH PARK SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | ₹52.0 L | L3 | Rejected-Finance Not become lowest bidder |
| 4 | L4₹54.5 LRejected-Finance | ₹54.5 L | L4 | Rejected-Finance Not become lowest bidder |
| 5 | L5₹55.2 LRejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | ₹55.2 L | L5 | Rejected-Finance Not become lowest bidder |
| Sl No | Description | Qty | Unit | M/S Kumar Contractors L2 | ROHIT ENTERPRISES L5 | NAVEEN TRADERS L3 | M/s Sohanil Construction L1 | V K Engineers and Associates L7 | M/s BRIJ KUMAR RAI L4 | ADARSH ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L in replacement of Power Cables, Aluminum Stranded Conductor 400 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion all as specified and directed by Engineer-in-Charge
Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ. | 60 | RM | 1,750 ₹1.1 L | 1,818 ₹1.1 L | 1,698 ₹1.0 L | 1,695 ₹1.0 L | 1,900 ₹1.1 L | 1,800 ₹1.1 L | 1,850 ₹1.1 L |
| 2.00 | All as per item No. 1.00 here-in-before but of size 300 sqmm, 3.5 core. | 100 | RM | 1,600 ₹1.6 L | 1,638 ₹1.6 L | 1,498 ₹1.5 L | 1,495 ₹1.5 L | 1,750 ₹1.8 L | 1,700 ₹1.7 L | 1,700 ₹1.7 L |
| 3.00 | All as per item No. 1.00 here-in-before but of size 240 sqmm, 3.5 core. | 150 | RM | 1,340 ₹2.0 L | 123 ₹18,450 | 1,295 ₹1.9 L | 1,295 ₹1.9 L | 1,550 ₹2.3 L | 1,500 ₹2.3 L | 1,500 ₹2.3 L |
| 4.00 | All as per item No. 1.00 here-in-before but of size 185 sqmm, 3.5 core. | 300 | RM | 1,300 ₹3.9 L | 1,363 ₹4.1 L | 1,195 ₹3.6 L | 1,195 ₹3.6 L | 1,650 ₹5.0 L | 1,600 ₹4.8 L | 1,600 ₹4.8 L |
| 5.00 | All as per item No. 1.00 here-in-before but of size 150 sqmm, 3.5 core. | 300 | RM | 900 ₹2.7 L | 959 ₹2.9 L | 788 ₹2.4 L | 795 ₹2.4 L | 900 ₹2.7 L | 850 ₹2.5 L | 890 ₹2.7 L |
| 6.00 | All as per item No. 1.00 here-in-before but of size 120 sqmm, 3.5 core. | 410 | RM | 800 ₹3.3 L | 1,019 ₹4.2 L | 698 ₹2.9 L | 695 ₹2.8 L | 1,000 ₹4.1 L | 950 ₹3.9 L | 980 ₹4.0 L |
| 7.00 | All as per item No. 1.00 here-in-before but of size 95 sqmm, 3.5 core. | 400 | RM | 800 ₹3.2 L | 1,288 ₹5.2 L | 785 ₹3.1 L | 785 ₹3.1 L | 1,150 ₹4.6 L | 1,100 ₹4.4 L | 1,100 ₹4.4 L |
| 8.00 | All as per item No. 1.00 here-in-before but of size 70 sqmm, 3.5 core. | 200 | RM | 295 ₹59,000 | 296 ₹59,200 | 285 ₹57,000 | 285 ₹57,000 | 340 ₹68,000 | 350 ₹70,000 | 350 ₹70,000 |
| 9.00 | All as per item No. 1.00 here-in-before but of size 50 sqmm, 3.5 core. | 300 | RM | 195 ₹58,500 | 218 ₹65,400 | 190 ₹57,000 | 195 ₹58,500 | 225 ₹67,500 | 230 ₹69,000 | 220 ₹66,000 |
| 10.00 | All as per item No. 1.00 here-in-before but of size 35 sqmm, 3.5 core. | 200 | RM | 185 ₹37,000 | 182 ₹36,400 | 178 ₹35,600 | 185 ₹37,000 | 300 ₹60,000 | 250 ₹50,000 | 290 ₹58,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
16 Apr 2026, 6:00 pmClosed
Maj Rajesh Rathore
Garrison Engineer Jhansi
REPAIR, MAINTENANCE AND RENEWALS TO VARIOUS LT OH LINES, LT UG CABLES ALONG WITH LT PANELS AND CONNECTED WORKS AT C ZONE UNDER AGE E/M AT GE JHANSI
2026_MES_757786_1
GE/JHA/TOK/111 OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE Jhansi
AS per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Jhansi
₹1 L
Yes
9 Jun 2026
26 Mar 2026
18 Apr 2026
26 Mar 2026
16 Apr 2026
9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
M&L in replacement of Power Cables, Aluminum Stranded Conductor 400 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion all as specified and directed by Engineer-in-Charge
Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ. | - | RM | - | - | |
All as per item No. 1.00 here-in-before but of size 300 sqmm, 3.5 core. | - | RM | - | - | |
All as per item No. 1.00 here-in-before but of size 240 sqmm, 3.5 core. | - | RM | - | - | |
All as per item No. 1.00 here-in-before but of size 185 sqmm, 3.5 core. | - | RM | - | - | |
All as per item No. 1.00 here-in-before but of size 150 sqmm, 3.5 core. | - | RM | - | - | |
All as per item No. 1.00 here-in-before but of size 120 sqmm, 3.5 core. | - | RM | - | - | |
All as per item No. 1.00 here-in-before but of size 95 sqmm, 3.5 core. | - | RM | - | - | |
All as per item No. 1.00 here-in-before but of size 70 sqmm, 3.5 core. | - | RM | - | - | |
All as per item No. 1.00 here-in-before but of size 50 sqmm, 3.5 core. | - | RM | - | - | |
All as per item No. 1.00 here-in-before but of size 35 sqmm, 3.5 core. | - | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
TenderDocuments111.pdf
Tender Documents • 1.27 MB
BOQ_848810.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid