| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC 02 AB ADGAONKAR PLAZA NEAR ABB CIRCLE MAHATMA NAGAR NASHIK 422 007 MAHARASHTRA | NASHIK | MAHARASHTRA | 422007 | ₹3.2 Cr Quoted ₹3.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹4.1 Cr+₹87.2 L (26.7%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹4.1 Cr+₹87.2 L (26.7%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹4.8 Cr+₹1.5 Cr (46.9%)Rejected-Finance UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | ₹4.8 Cr+₹1.5 Cr (46.9%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹4.9 Cr+₹1.7 Cr (51.2%)Rejected-Finance | ₹4.9 Cr+₹1.7 Cr (51.2%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹5.3 Cr+₹2.0 Cr (60.5%)Rejected-Finance | ₹5.3 Cr+₹2.0 Cr (60.5%) | L5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | JAI CONSTRUCTION CO. L4 | Joy builders L3 | Ishan Constructions L5 | Vishal Builders L2 | P L ADKE L1 |
|---|---|---|---|---|---|---|---|---|
| .10NOTE: Schedule ‘A’ Part I to XII are under Ser No. 1.00 to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | ||||||||
| 1.00 | Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A’ Part I. | 1 | Lumpsum | 3,80,00,000 ₹3,80,00,000 | 3,65,00,000 ₹3,65,00,000 | 3,75,00,000 ₹3,75,00,000 | 3,01,82,000 ₹3,01,82,000 | 2,20,00,000 ₹2,20,00,000 Lowest |
| 2.00 | Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A’ Part II. | 1 | Lumpsum | 3,25,000 ₹3,25,000 Lowest | 3,30,000 ₹3,30,000 | 3,50,000 ₹3,50,000 | 3,25,000 ₹3,25,000 Lowest | 3,50,000 ₹3,50,000 |
| 3.00 | Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A’ Part III. | 1 | Lumpsum | 2,42,000 ₹2,42,000 | 2,50,000 ₹2,50,000 | 3,00,000 ₹3,00,000 | 2,40,000 ₹2,40,000 | 1,50,000 ₹1,50,000 Lowest |
| 4.00 | Lump sum price worked out for INTERNAL ELECTRIFICATION INCLUDING UPGRADATION ITEMS as listed in Sch 'A’ Part IV. | 1 | Lumpsum | 26,50,000 ₹26,50,000 | 25,80,000 ₹25,80,000 | 31,00,000 ₹31,00,000 | 25,30,000 ₹25,30,000 | 25,00,000 ₹25,00,000 Lowest |
| 5.00 | Lump sum price worked out for ROAD/ PATH/ HARDSTANDING as listed in Sch 'A’ Part V. | 1 | Lumpsum | 10,45,000 ₹10,45,000 | 10,40,000 ₹10,40,000 | 11,00,000 ₹11,00,000 | 10,30,000 ₹10,30,000 Lowest | 11,00,000 ₹11,00,000 |
| 6.00 | Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A’ Part VI. | 1 | Lumpsum | 1,70,000 ₹1,70,000 | 1,80,000 ₹1,80,000 | 1,75,000 ₹1,75,000 | 1,72,000 ₹1,72,000 | 1,50,000 ₹1,50,000 Lowest |
| 7.00 | Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A’ Part VII. | 1 | Lumpsum | 2,05,000 ₹2,05,000 | 2,15,000 ₹2,15,000 | 2,50,000 ₹2,50,000 | 2,00,000 ₹2,00,000 Lowest | 2,00,000 ₹2,00,000 Lowest |
| 8.00 | Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A’ Part VIII. | 1 | Lumpsum | 5,15,000 ₹5,15,000 | 5,20,000 ₹5,20,000 | 6,00,000 ₹6,00,000 | 5,00,000 ₹5,00,000 | 3,00,000 ₹3,00,000 Lowest |
| 9.00 | Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A’ Part IX. | 1 | Lumpsum | 3,80,000 ₹3,80,000 | 3,65,000 ₹3,65,000 | 6,50,000 ₹6,50,000 | 3,70,000 ₹3,70,000 | 3,00,000 ₹3,00,000 Lowest |
Tender Value
₹3.0 Cr
EMD Value
₹3.8 L
Closing Date
17 Jul 2025, 6:00 pmClosed
CE (AF) GANDHINAGAR
HQ CE (AF) GANDHINAGAR, Lekhawada Patia, Chiloda, Gandhinagar 382042
DEMOLITION AND RECONSTRUCTION OF AIRMEN MESS, SNCOs BILLETS AND ADDN/ ALTN TO AIRMEN BILLETS AT AIR FORCE STATION MADH ISLAND
2025_MES_691808_3
84202
Open Tender
Civil Works
Lump-sum
365 days
GE (AF) Thane
All as per NIT and Tender Documents
7 documents required · 7 mandatory
₹2,000
GE (AF) Thane
₹3.8 L
Yes
11 Aug 2025
20 Jun 2025
19 Jul 2025
20 Jun 2025
17 Jul 2025
5 Jul 2025
21 Jun 2025 - 26 Jun 2025
Amount
NOTE: Schedule ‘A’ Part I to XII are under Ser No. 1.00 to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A’ Part I.
Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A’ Part II.
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A’ Part III.
Lump sum price worked out for INTERNAL ELECTRIFICATION INCLUDING UPGRADATION ITEMS as listed in Sch 'A’ Part IV.
Lump sum price worked out for ROAD/ PATH/ HARDSTANDING as listed in Sch 'A’ Part V.
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A’ Part VI.
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A’ Part VII.
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A’ Part VIII.
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A’ Part IX.
Lump sum price worked out for UPGRADATION OF B&R WORKS as listed in Sch 'A’ Part X.
Lump sum price worked out for REFRIGERATION as listed in Sch 'A’ Part XI.
Lump sum price worked out for DEMOLITION/ DISMANTLING as listed in Sch 'A’ Part XII.
SCHEDULE `A' PART-XIII MISCELLANEOUS ITEMS OF WORK (Note: The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
DEMOLITION/ DISMANTLING
Taking down unservicable main switches, DBs, metal clad sockets etc. complete all as specified and directed.
Taking down unservicable submain wiring any type/ size complete all as specified and directed.
Taking down unservicable MCBs isolators from existing DBs complete all as specified and directed.
Taking down ceiling fan of 1200 mm sweep from existing place or from any height and depositing in E/M store yard for disposal complete all as specified and directed.
Taking down exhaust fan of 300/ 450 mm sweep from existing place or from any height and depositing in E/M store yard for disposal complete all as specified and directed.
Taking down wall mounting fan of 350 mm sweep from existing place or from any height and depositing in E/M store yard for disposal complete all as specified and directed.
Taking down geyser from existing place or from any height and depositing in E/M store yard for disposal complete all as specified and directed.
Taking down water cooler of capacity 40/ 80 Litre per hour from existing place or from any height and depositing in E/M store yard for disposal complete all as specified and directed.
Taking down GI pipe of any type and size complete all as specified and directed.
Taking down gun metal gat or globe valves of any type and any size complete all as specified and directed.
Taking down XLPE cable of any type and size complete all as specified and directed.
Taking down LT panel of any type and any size with MCCBs and other accessories complete all as specified and directed.
Taking down earthing of any type complete all as specified and directed.
UPGRADATION OF B&R WORKS
Material and labour for removing existing water proofing treatment (except concrete padding) and removing debris/ rubbish materials off the site complete all as specified and as directed.
Supply and fix in repair 75mm dia of outlet PVC (SWR) nahani trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Material and labour for special treatment for sunken portion of WC's bath toilet, kitchen etc. executed in following stages: Stage 1: Providing 15mm thick plaster in CM 1:3 mixed with water proofing chemical for Dr. Fixit or Shalicrete 'R' of STP Ltd in the proportion/ quantity all as per manufacturer's instructions. Stage 2: Primer-mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces. Stage 3: Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) 1 kg/ sqm by brush all as per manufacturer's instructions. Stage 4: Laying fibre glass cloth of weight not less than 50 gms/ sqm over the first coat while the coated surfaces is still sticky. Stage 5: After 6 to 7 hours interval, apply second coat ie. final coat of Tarfelt LM of STP Ltd (without dilution with water) 1 kg/ sqm by brush all as per manufacturer's instructions. Stage 6: Providing 10mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250 Ml/ 50 kg cement all as per manufacturer's instructions. Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. Notes: (i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid. (ii) The above treatment shall be got executed through authorised applicator of manufacturer and necessary authenticated documents on account of above shall also be produced by the contractor.
Supply and fix chromium plated toilet paper holder and fixed over glazed ceramic tiles complete all as specified and directed.
INTERNAL ELECTRIFICATION INCLUDING UPGRADATION ITEMS
Supply and fix in replacement LED study lamp suitable for reading complete all as specified and as directed.
Supply and fix in replacement LED bulb 9 Watt with fiitings , 230 Volts complete all as specified and as directed.
Refixing of geyser to the original position as removed for demolition and making good the disturbed surfaces complete all as specified and as directed.
Supply and fix meter box of size (1 m x 1m x 0.25 m) made of polycarbonate and having transparent cover, weather/ vermin proof, anti-acid, anti-corrosive, UV resistant, fire retardant, thickness 2.25 mm double door, single opening with lock arrangement suitable for fixing 01 electric meter and TPN DB box including taking down existing electric meters, refixing them with two single core PVC copper conductor unsheathed wire multistranded 4 sqmm including properly painting and fixing in wall with suitable cutting, cement and brick work etc. complete all as specified and as directed.
Refixing/ hanging the ceiling fan including electric connection with and including new flexible sheathed copper wire 3 core from ceiling rose/ connector to fan connector, including replacement of new nut bolts, rubber reel, capacitor 2.5mfd, machine screws and split pins etc. including painting the ceiling fan complete body with blades, canopies, down rod etc. with synthetic enamel paint by spray gun in colour as directed after scraping down old paint complete all as specified and as directed.
EXTERNAL WATER SUPPLY
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed for 80 mm bore dia of pipe complete all as specified and as directed
Material and labour for cutting CI pipes of dia 80 mm in position for insertion and including provision of tee branches etc. for 80 mm dia pipe line complete all as specified and as directed
Material and labour for construction of valve chamber of size 1200 mm x 1200 mm x 900 mm internal size including necessary earth work and excavation etc. in any type of soil, PCC (1:3:6) type C2 in foundation, PCC (1:2:4) type B1 in coping, brick wall in CM 1:4, 10 mm thick cement plaster (1:3) internally and provision of MS sheet cover 10 gauge thick with locking arrangement and pad lock of brags 35 mm with triplicate keys, cover fixed to angle iron frame made out of 40mm x 40mm x 6mm with hinges including painting of MS cover frame etc. with two coats of black synthetic enamel paint over a coat of red oxide primer and including taking out unservicable valve pit chamber complete all as specified and as directed
EXTERNAL ELECTRIFICATION
Material and labour for cutting existing road/ hardstanding not exceeding 50 x 60 cm in width and depth and getting out excavated material for laying GI tube for passing through LT cable, returning filling and well ramming, watering and finishing surfaces 10 cm from top using PCC 1:1.5:3 including removal of surplus soil complete all as specified and as directed.
Supply, fabricate and install LT distribution panel (CPRI approved) pedastal type outdoor factory fabricated made out of 3.15 mm thick CRCA sheet, size not less than 2.0 m x 0.9 m x 1.5 m and suitable size to accommodate all accessories/ fittings, compartmentalised in construction to accomodate incoming MCCBs and TPN aluminium bus bars of suitable capacity of 600 Amps. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/ epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have aluminium extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ epoxy insulators having provision for terminaton of incoming and outgoing cables. All extension links/ interconnecion shall be colour coded sleeves. The cubical shall have a bottom channel of size 75 x 40 mm duly coated with zinc metal coating.
A detachable pregrilled gland plate of thickness not less than 3 mm hick zinc metal coated should be used at he bottom for entry of armoured cable of adequate size with glands. The above panel shall be front openable by double door form and shall have louvers and qirvent gasket for natural flow of air adhesive type gasket shall be used to make panel vermin proof and panl shall be cold zinc (for rust proof) sprayed thickness complete all as specified and as directed consisiting and comprising of the following: (a) Busbar aluminium TPN 600 Amps - 01 set (b) MCCB 4 pole 250 Amps 415 Volts 36 KA - 01 No. (incoming) (c) MCCB TP 125 Amp 415 Volts 16 KA - 04 Nos. (outgoing) (d) MCCB TP 100 Amp 415 Volts 16 KA - 03 Nos. (outgoing) (e) Digital voltmeter - 01 No. (f) Digital ammeter - 03 Nos.
REFRIGERATION AND HOT WATER SUPPLY
Supply and fix refrigerator, electric driven (single phase) of capacity 310 Litres, BEE 5 star rated, 230 V, AC single phase complete all as specified and as directed
Supply and fix storage type water heater (geyser) electrical operated 230/ 240 Volts 25 Litre capacity, BEE five star rated complete with all safety equipment and accessories such as safety valve, thermostat, fusible plug, top plug 15 Amp, heating element upto 2 KW rate pressure 6 bar etc. required for proper functionality and including electric/ earth connections and carrying out grounting and complete installation with mounting bolts, nuts including testing after installation complete all as specified and as directed
NOTE : Amount of credit of Rs. 8,40,379.25 for retrieved materials is mentioned in schedule of credit on Srl Page No. 61 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Vishal Builders (BID ID -3353572)
Joy builders (BID ID -3352714)
JAI CONSTRUCTION CO. (BID ID -3352668)
Ishan Constructions (BID ID -3353364)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .