| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC VILL BUNGDAL DADHANI P O BADHANI DISTT PATHANKOT PIN 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Bid accepted being lowest tendrer | |
| 2 | L2₹26.1 L+₹15,375 (0.59%)Rejected-AOC | L2 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 3 | L3₹26.1 L+₹21,304.50 (0.82%)Rejected-AOC | L3 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 4 | L4₹27.5 L+₹1.6 L (6.18%)Rejected-AOC | L4 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 5 | L5₹28.0 L+₹2.0 L (7.90%)Rejected-AOC | L5 | Rejected-AOC Other than lowest tendrer hence rejected |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
31 Dec 2019, 6:00 pmClosed
CWE Mamun
HQ CWE Mamun Pathankot 145001
SPECIAL REPAIR TO BAFFLE RANGE, BLDG NO P-52 TO P-54 , P-56 TO P-58, P-60 AND P-62 TO 65, UNDER GE (SOUTH) MAMUN AT MAMUN MIL STATION
2019_MES_304432_1
CWE/M-37/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE South Mamun
Class D Category a i
5 documents required · 5 mandatory
₹500
GE South Mamun
₹75,000
Yes
13 Feb 2020
6 Dec 2019
1 Jan 2020
6 Dec 2019
31 Dec 2019
26 Dec 2019
Amount
Taking down chowkats or frames of any description not exc 1.50 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware , complete all as specified and directed.
Taking down chowkats or frames of any description exc. 1.50 Sqm and n.exc 4.00 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware , complete all as specified and directed.
Taking down shutter of any description exceeding 1 sqm and not exceeding 2 sqm each and refixing the same after the adjustment the shutter including builders hardware etc, complete all as specified and directed.
M&L for Box type Steel windows and ventilators comprised of tubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side hung wire gauged shutter & glass/glazed shutter (wire cloth and glass panes only shall be measured and paid separately) with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg, welded to F I frame work, including other fittings; hinges, handles, tarred hold fasts fixed in PCC blocks all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated, fitted to chowkhats complete all as specified and directed.
S&F in repair Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, orstainless steel wire staples complete all as specified and directed.
Hacking out old broken glass ( any thickness , size, quality, or description) from metal frame glazed with putty or fixed with beads/ clips complete all as specified and directed.
M&L for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain pre-painted PVC sheet ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain pre-painted PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain pre-painted PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
M & L for preparation of new wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of old wood or wood based surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws, supply and fixing in opening as per specification & drawing complete all as specified and directed. [Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life]
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane complete all as specified and directed.
M&L for 3 mm thick Figured glass, pin head type & glazing with oil putty in squares n exc 0.5 sq.m in each panecomplete all as specified and directed.
M&L for 300mm aluminium alloy sliding door bolt with hasp & staple (bolt type) and fixing clip of sheets cast or extruded section and fixing sliding bolt of extruded section complete all as specified and directed.
M&L for Aluminium anodised barrel tower bolt, extruded section 150mm long , complete all as specified and directed.
M&L for Aluminium anodised barrel tower bolt, extruded section 100mm long , complete all as specified and directed.
M&L for Aluminium anodised handle, extruded section of size 150mm complete all as specified and directed.
Demolitin of brickwork built in cement mortar including all quions ,arches,pillars etc but excluding ashlar facings dressed stonework and pre cast concrete articles complete all as specified and directed.
M&L for Brick work with Fly Ash Brick (Non-Modular) straight or curved on plan to any radius in half brick thick walls built in (1:4) etc complete all as specified and directed.
M&L for Brick work with Fly Ash Brick (Non-Modular) Class 7.5, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement ,complete all as specified and as directed.
M&L for rendering 5mm thick cement plaster on surfaces of concrete ceiling in cement mortar (1:3), surface finished even and smooth using extra cement, complete all as specified & directed.
M&L for Rendering 15mm thick in two layers (base layer 10mm in cm 1:6 & finishing layer 5mm thick in cement mortar (1:4) using liquid water proofing compound (In 2nd Coat only) on brick work or concrete surfaces of wall surfaces finished even and smooth using extra cement complete all as specified & directed. (Note : WPC shall be measured and paid separately)
M&L for rendering or plastering work 10mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas, roof projections etc, including taking down of old plaster / concrete and making the line in true shape and finishing the surface without using extra cement complete all as specified & directed.
M&L for preparation of new decorated plastered or unplastered surface of wall including cornices, pillaster/karb stone etc by washing, rubbing, stopping, brooming down with steel wire brushing scraping down smoke soots, mould, efflorencent slat and trading oil and greasy spots complete and providing one coat of Acrylic Emulsion exterior paint on walls/ceiling/ kerb stone/ facia complete all as specified & directed.
M&L for two coats of distemper oil emulsion over a coat of primer including preparation of new surfaces complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and apply three coats of white wash on plastered surfaces complete all as specified and directed.
M&L two coats of oil bound distemper on old surface of wall including preparation of old plastered surface complete all as spd and directed.
M&L for Preparation of newly plastered surface and applying two coats of cement base paint over a coat of primer as per manufacturer recommendation complete all as specified and directed.
M&L for preparing newly plastered surfaces and applying two coats of OBD (oil bound distemper) over one coat of chalk whitening primer on wall surfaces complete all as specified and directed.
M&L two coat of Acrylic Emulsion exterior paint including preparation of existing surfaces complete all as specified and directed.
M&L for preparation of existing white washed surfaces of walls and apply two coats of white wash on plastered surfaces complete all as specified and directed.
M&L for Preparation of old surface after complete removal of existing treatment making the surface smooth and applying two coats of cement base paint over a coat of primer as per manufacturer recommendation complete all as specified and directed.
M&L for preparation of existing surfaces of ceiling and apply two coats of white wash on plastered surfaces complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio (1:2) by weight complete all as specified and directed.
M&L for 40 mm thick PCC (1:2:4) type B-1,using (20 mm graded aggregate) in subbase, sub floors, base floors etc, complete, all as specified and directed
M&L for Non-skid ceramic coloured rectified edges joints free tiles 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges tiles 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in as skirting/dado/riser of steps etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4), including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and directed.
M&L for Glazed ceramic (coloured) tiles 7mm thick, of size 450mmx300mm, 7mm thick on vertical surfaces such as dado etc, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match tiles over and including 10mm thick backing coat in cement mortar (1:4), surface finished even and rough to receive tiles, including dismantling existing tiles of any type and pattern including cement mortar backing coat and removal of rubbish out off the premises, etc complete all as specified and directed.
M&L for 18-20mm thick machine cut Kota stone slab in single piece in treads/flooring etc, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match including rounding the edges and cuttting two grooves (serration) of kota stone over and including 20mm thick screed bed in CM 1:6, surfaces finished even and rough to receive kota stoneincluding dismantling existing tiles of any type and pattern including cement mortar backing coat and removal of rubbish out off the premises, etc complete all as specified and directed.
Taking up/down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 15mm complete all as specified and directed.
Taking up/down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 20mm complete all as specified and directed.
S&F for GI water tubing 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) fixed to wall or ceiling or laid in floor complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Cutting chases not exceeding 10cm in width/girth for concealed water tubing or concealed conduit wiring etc and making good in cement mortar 1:3 to match existing surface etc complete all as specified and directed.
S&F for GI water tubing 20mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) fixed to wall or ceiling or laid in floor complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
S&F in repair Stop valve/ Angle valve cast copper alloy (ISI Marked) chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15mm bore dia complete all as specified and directed.
S&F in repair for 15mm bore bib taps fancy type with wall flange, chromium plated cast copper alloy long body with capstan heads, screwed for iron pipe or brass ferrule complete all as specified and directed. Make : Jaquar Cat part No CON-047KN or equivalent model in Hindware/Marc.
S&F in repair 15mm bore Stop valves fancy type, chromium plated cast copper alloy long shank and exposed part kit with fitting sleeve, operarting lever & adjustable wall flange (concealed type) screwed both ends for iron pipe or for unions complete all as specified and directed. Make : Jaquar Cat part No CON-083FT & CON-083FTK or equivalent of Hindware/Marc.
S&F in repair for Vitreous china wash hand basin, white, flat back, size 550x400mm (Make : Jaquar Cat part No CNS-WHT-801 or equivalent of Hindware/Parryware/Somany) including 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated (Make : Jaquar Cat part No CON-021KN or equivalent of Hindware/Marc.) brackets, CP waste coupling, 32mm bore PVC waste outlet pipe of min 600mm long, including cutting for and pinning in end of brackets complete all as specified and directed.
S&F in repair for single towel rail brass chromium plated 600mm long fixed with chromium plated screw and PVC cleat complete all as specified and directed. Make : Cat part No AQN-7711 of Jaquar or equivalent model in Hindware/Marc.
S&F in repair Brass Chromium Plated shower rose with arms fancy type with swivel joints 75 mm face dia of appoved make and cat part for 15mm bore iron pipes complete all as specified and directed. Make : Prayag Cat part No BS-73 or equivalent model in Hindware/Marc.
S&F in repair for Vitreous china White Squatting Orissa Pattern pan of size 580x440mm, including cast iron ‘P’ or ‘S’ trap, front or back inlet and integral foot rests and making connection to trap and to flushing pipe, anti syphonic pipe etc complete all as specified and directed. (Note : Demolition and refilling of concrete in sunken portion shall be measured and paid separately.)
M&L for Rendering 15 mm thick on brick work or concrete surfaces in CM 1:4 and finishing cement concrete surface even and smooth using without extra cement and neeru finish to plastering complete all as specified and directed.
S&F in repair for 100 mm Cast iron floor trap, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) with CP grating with or without hole for waste pipe complete all as specified and directed.
S&F in repair for PVC flushing cistern dual flush type 10 Ltr capacity, valve-less syphonic action type, low level, complete with inlet, ball valve, handle, including brackets/pins, PVC flush pipe 32mm bore complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. Make:Paryag/Polytech
S&F in repair for Rotational moulded polyethylene water storage tanks three layer of capacity 1000 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball and dismantling of existing RCC/PVC tank of any capacity, complete all as specified & directed.
S&F in repair for Rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball and dismantling of existing RCC/PVC tank of any capacity, complete all as specified & directed.
S&F in repair for 75 mm Cast iron Nahani trap, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) with CP grating with or without hole for waste pipe complete all as specified and directed.
S&F in repair for 75 mm Cast iron floor trap, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) with CP grating with or without hole for waste pipe complete all as specified and directed.
S&F in stainless steel Grating doom 100mm dia fixing in floor complete all as specified and directed.
S&F in stainless steel Grating doom 100mm dia with waste hole, fixing in floor complete all as specified and directed.
Rough excavation not exc. 1.5m deep and getting out in any type of soil complete all as specified and directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick watering, ramming /rolling and finishing to required size, shape, n exc. 1.5 m high from base complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed.
M&L for RCC1:1½:3 Type A-1 using 20mm graded crushed stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork including demolition of existing cover slabs of any description and removal of rubbish out off the premises etc complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately)
M&L for 80mm thick factory made rubberised coloured (laminated) interlocking paver block (using vibro compaction method) (topping thickness not less than 5mm) in white cement and non fadable glossy pigment of approved shade of any shape and size conforming to IS-15658-2006 of M-40 grade laid over & including cleaned dry sand cushion 50mm thick over and including 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) including demolition of damaged cement concrete of any type or description and removal of debris out off the premises etc complete all as specified and directed.
M&L for 30mm thick, 2nd class soft wood Boarding, supplied & fixed with nails in any situation (except flooring and skirting) clean sawn with butt joints including dismantling of old wooden boarding complete all as specified and directed.
M&L for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer including taking down existing treatment with following specification complete all as directed :- (a) Cleaning surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
Taking down carefully unserviciable/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /skh fitting ) and removing material from site and making good to the disturbed surface to match with existing finish complete all as specified and directed.
M&L for Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box and approved make sunken modular metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting modular switches/ sockets etc, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point etc complete all as specified and directed. (Note : Modular switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
All as per Srl item No.75 above but for 5 pin 6/10 Amp socket outlet point on independent gang box and suitable support frame and cover plate (inner/outer) controlled by one switch 6/10Amp one way, etc complete all as specified and directed.
All as per Srl item No. 75 above but for 5 Pin 6/10 Amp socket outlet point controlled by one switch 6/10 Amps one way on same gang box support frame and cover plate etc complete all as specified and directed.
All as per Srl item No. 75 above but for one 15Amp socket outlet point concealed using 2.5 Sqmm FRLS PVC insulated multi-strand copper conductor wire including 2.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire and making good to disturbed surfaces of wall floor to match existing finishes complete all as specified and directed.
S & F modular switch piano type flush button one way 06/10 Amp one module complete all as specified and directed. Make : Legrand Cat Part No 673000/Crabtree Cat Part No ACMSXXW101/Anchor Roma Cat Part No 66111.
S & F modular switch piano type flush button 16 Amp one module, complete all as specified and directed. Make : Legrand Cat Part No 673009/Crabtree Cat Part No ACMSXXW102/Anchor Roma Cat Part No 66104.
S&F Modular Socket outlet, 5 pin, multi purpose, 2 module 6/16 Amp, AC 230 volts, etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVKCWW163 or equivalent of Legrand/Siemens/Schneider/Anchor Roma
S&F Modular Socket outlet, 5 pin, multi purpose 2 module 6 Amps, AC 230 volts, etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVKSWW065 or equivalent of Legrand/Siemens/Schneider/Anchor Roma.
S&F Modular electronic fan regulator, stepped type, hum free socket type suitable to control speed of fan 0-100%, 230 V etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVRFHW005 or equivalent of Legrand/Siemens/Schneider/Anchor Roma
S&F Ceiling rose polycarbonate isolated body surface Bakelite, not less than 50x20mm, three terminals, AC 230 volts etc complete all as specified and directed. Make : Anchor (Penta) Cat Part No : 39040 or equivalent of Havells(Reo)/SSK (Topline)/GM (Vyoma)
S&F Double door openable MCB DB SPN, 240 Volts, 04 Way made out of CRCA powder coated sheets, IP43 protection with copper bus bar including taking out old unsv DB any size/type, complete all as specified and directed. Make: Legrand Cat Part No 5076-10 or equivalent model in Hager/SCHNEIDER
S&F Double door openable MCB DB SPN, 240 Volts, 08 Way made out of CRCA powder coated sheets, IP43 protection with copper bus bar including taking out old unsv DB any size/type, complete all as specified and directed. Make: Legrand Cat Part No 5076-11 or equivalent model in Hager/SCHNEIDER
S&F Lamp holder insulated body with back plate suitable for batten fitting including 12W LED lamp of approved make and cat part and PVC Round/Square block etc complete all as specifeid and directed. Make : Anchor (Penta) Cat Part No : 51170 or equivalent of Havells(Reo)/SSK (Topline)/GM (Vyoma) for Lamp holder & Make :Bajaj/OSRAM/Polycab/Havells /Philips/ Crompton Greaves for LED lamp
M&L for Surface mounted 1x20 watt LED tube light fittings (4 feet long), prewired, decorative luminaire with inbuilt LED tube rod and acrylic end covers with all accessories and PVC Round/Square block for fixing of fittings and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
S&F in replacement LED Bulk head 1 x 10 watt energy efficient wall mounted, pressure die cast aluminium housing & enclosed with poly carbonated cover with all accessories including lamp complete including connecting up with three core twisted flexible copper conductor cable of suitable size, all as specified and direted.
M&L for Surface mounted 1x10 watt LED tube light fittings (2 feet long), prewired, decorative luminaire with inbuilt LED tube rod and acrylic end covers with all accessories and PVC Round/Square block for fixing of fittings and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
S &F building LED security light luminaries 45 W LED 5000K AC 230 volts, new generation saving & enviromental friendly long life versatile pressure die cast aluminium luminaries with high power LED as light source complete making connection with street light/ building security light box or OH line using PVC insulated and sheathed single core multi stranded copper conductor cable of size 1.5Sqmm including suitable size 32mm of bracket and light grade pipe for muntaining of fitting complete all as specified and directed. Make : Crompton Greaves Cat Part No LSTP-45-CDL or equivalent model in Bajaj/OSRAM/Polycab/ Havells/Philips Notes for Srl Item Nos 88 to 91 :- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be povided. 3. CRI (Colou Rendring Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be > 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the Contractor shall replace / repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 11. CA No shall be written on each fitting before installation.
S&F MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) , complete all as specified and directed.
S&F MCB single pole neutral (SPN) 240 volts, 6 to 32 Amps, 10KA (C-series) complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI medium grade pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil should be free from stone, boulders, aggregate, gravels .
Taking down ceiling fan of any sweep & size and refix in same position after overhauling including minor repairs by replacement of capacitor, safety pin, cap, nuts & bolts etc and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose to fan, including testing to ensure efficient functioning including application of one coat of synthetic enamel paint by spray painting & rewriting number complete all as specified and directed.
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 50 sqmm 4 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 16 sqmm 2 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 10 sqmm 2 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth; for foundation, laying of cable/pipe etc. n. exc 10 sqm on plan & n. exc 1.5 m in depth & getting out in any type of soil etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed.
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified and directed.
M & L for sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. [Note : Punned thickness shall be measured and paid]
M & L for well burned bricks , laind flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed.
S&F GI tubing 40 mm bore light grade laid in trenches/floors/ fixed to wall/poles for protection of cable with necessary fittings and FI clamps duly painted complete all as specified and directed.
M/S BHOTO AND CO
JAGIR CONSTRUCTION CO
Abrol construction co
Raghbir chand
KULBHUSHAN AGGARWAL
M/S INDIAN ELECTRICAL
M/s GIrdhari Lal Rakesh Kumar
Alishan Builders
A V BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .