Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.6 L+₹1.1 L (2.31%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹49.7 L+₹1.2 L (2.48%)Rejected-Finance OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹49.8 L+₹1.4 L (2.80%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹50.0 L+₹1.5 L (3.13%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
ADDN /ALTN TO SQUASH COURT AT MINNIE BAY AND SPL REPAIR AND IMPROVEMENT TO EXISTING HARD GROUND AND ROAD AT SHO MINNIE BAY AND OTHER CERTAIN MINOR WORKS UNDER GE MINNIE BAY PORT BLAIR
2023_MES_627116_1
8319/E8
Open Tender
Civil Works
Item Rate
180 days
Minniebay Port Blair
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE Minniebay
₹96,000
Yes
29 Dec 2023
6 Nov 2023
29 Nov 2023
7 Nov 2023
27 Nov 2023
21 Nov 2023
Amount
Dismantling plain or corrugated steel sheeting,any gauge, thickness,including nanital or similar pattern roof coverings including ridges complete all as specified and directed by Engineer in Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer in Charge.
S&F Mild steel work in Roof trusses (Framed), trussed, purlins, rafters, crane gantries, rails ,posts and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.including necessary welding confirming to Fe-410-W(Gde-E250 quality-A) complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvalume aluminium zinc coating corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvalume aluminium zinc coating plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
S&F aluminium flat as wind tie fixed with 50mm / 75mm aluminium self staging screws complete all as specified and directed by Engineer in Charge.
Dismantling of wall and ceiling boards(fibre,pulp,insulation etc) or insulation boards/slabs/blankets,any thickness,including cover fillets complete all as specified and directed by Engineer in Charge.
S&F aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm, Main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 610 x 610mm suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab, roof truss fixed with suitable size MS hook and fastening bolts etc including 6mm non asbestos sheet of size n.exc. 610 x 610mm size fixed in ceiling with clips to aluminium snap grid including preparation of new surface and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engr-in-Charge
Dismantling boarding,any description,fixed in any position complete all as specified and directed by Engineer in Charge.
Dismantling timber scantlings 40 sqcm and over in section,in any position complete all as specified and directed by Engineer in Charge.
Supply installation and finishing of Naturally & Kiln seasoned wooden squart court flooring complying indian standards with anti termite wooden floor boards of 21mm of "Maple" wood of size 1700mmx 125mm (except required size at end row) tongue grooved with controlled moisture content with tongue & groove arrangement, provided over and including anti termite wooden runners/ battens of 70mm x 45mm provdied at 350mmc/c including and over 10/19mm thick EPDM rubber air cell cushioning rubber pads (stappled) over vapour barrier including necessary line marking of required colour over the finished surfaces complete all as specified and directed by Engr-in-Charge. Note : (i) After finishing installation, the floor shall be mechanically sanded by using sander and finished with water base polish and bottom of the floor boards shall be applied with one coat of anti skid polyurethane coating. The surrouding board shall be left with 8 to 10mm gap for expansion purposes. (ii) An lumpsum amount of 5% of the cost of the item or Rs.50000/- which ever is higher shall be deposited as secuirty deposit for 08 years from the date of completion of the work along with guarantee bond in Rs100/- Non judicial stamp paper duly notarised. (iii) ATT work shall be carried out before the installation of squash court flooring and cost of the same shall be measured and paid under relevant item.
Taking down cement plaster on walls any description incl racking out joints hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer in Charge.
M&L Rendering 10mm thick on other than fair faces of brick/block work or concrete surfaces in cement mortar 1:6 (river sand)and finished fair and even without using extra cement of high impact property complete all as specified and directed by Engineer in Charge.
M&L for rendering 15mm thick cement plaster on fair faces of concrete block masnory in two layers, base layer 10mm thick in CM (1:6) and top layer 5mm thick in CM 1:4(with river sand) mixed with WPC as per manufacture' s instructions, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note :- WPC shall be measured and paid seperately
M&L preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer and 2mm thk wall care putty complete all as specified and directed by Engineer in Charge.( Wall care putty can be measured and paid separately)
M&L for complete removal of old existing treatment/finishes and providing necessary scaffolding & safety precautions and cleaning the surfaces free from any loose paint, dust,greases,growth of fungus,algae or moss using wire brush and levelling the surface even and smooth using mechanical sander and finally applying water by pressure jet washer of max pressure of 170 bar with automatic pressure relief system. The following process shall be initiated only after the above surface preparations :- (a) Filling the surface cracks using crack seal compound on required consistency using electric mixer. (b) Filling the dents and holes using wall care putty in appropriate ratio using electric mixer.(c) Applying one or two coats of damp proof primer (primer coat) using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m.(d) Applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm Anti algal weather coat 100% acrylic smooth emulsion paint using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m.
Note : (i) Work shall be executed only through authorised applicator duly approved by Manufacturer of Paint and certificate in this connection shall be submitted by the Contractor. (ii) The affected area of the wall due to dampness shall be ascertained by moisture meter of power input 9v Display 60 LEDs using colour code scale and Moisture measurement of each location shall be submitted along with RAR.(iii) The contractor shall upload MOU letter with any one of Paint manufacturer within 28 days of receipt of acceptance copy failing which contract shall be liable for cancellation. Authorised applicator shall have valid authorisation letter from the manufacturer The authorisation letter needs to be valid for the complete period of execution of the painting work.(iv) After preparation of the surface, Engr-in-Charge shall inspect and approve the same before applying primer and finishing coats.(v) Building wise stage passing register shall be maintained & submitted alongwith RAR/FB duly signed by Engr-in-Charge and contractor.
(vi) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into.The specification and details of the equipments and tools pertaining to this item is denoted on Particular Specification.Manual method of paint application is not allowed and also Penalty shall be levied if appropriate tools & equipments pertaining to smart periodicals not used.(viii) Proper masking arrangement shall be carried before the application of primer or paint.(ix) The other coat of Primer and Paint shall be applied only after the completion of drying time and comply with recoating period as per manufacturer instructions.(x) Cost of scaffolding upto (G+3) height of building shall be included in the quoted rate.
Dismantling floor, hearth or wall tiling including cement mortar bedding and rubbished off the premises complete all as specified and directed by Engineer in Charge.
M&L for 75 mm thick Plain Cement Concrete Nominal mix 1:2:4 type B-2(40 mm graded aggregate) as in path,hard standing and similar work all as specified and directed,finishing cement concrete surface even and smooth without using extra cement and Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green including necessary formwork complete all as specified and directed by Engineer in Charge.
M&L for chequred vitrified coloured tiles 300x300x10 mm thick each of tiles in floor/steps/stairs etc set jointed and pointed in neat cement slurry in floors including 15mm thick screed in CM 1:4 complete all as specified and directed by Engineer in Charge.
S&F ìn repairs stainless steel tubing of any diameter or square or rectangular in shape, thickness not less than 1.6mm of grade AISI-304 type aesthetic anticorossive in nature as in framed work/post/fencing work/railling/designer work, purposily made doom and base welded with tubing where required including cutting, bending, welding, grinding, buffing and bright polishing the welded joints and adjacent areas and fixing in any type of location complete all as specified and directed by Engineer in Charge.
Demolition of Cement Concrete(un reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
Removing building material etc (other than Spoil) to a distance of 500 mt,beyond lead included in the rates,including loading,un loading and stacking at the designation all as specified and directed by Engr-in-charge
M&L Hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed by Engr-in-Charge.
M&L for 100 mm thick Plain Cement Concrete Nominal mix 1:3:6 type C-2 (40 mm graded aggregate), finishing cement concrete as in sub base including formwork complete all as specified and directed by Engineer in Charge.
M&L Plain Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed by Engineer in Charge.
M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed by Engineer in charge
M&L for 75 mm thick PCC 1:3:6 type C-1 (40 mm graded aggregate) plinth protection and similar work all as specified and directed, finishing cement concrete surface evan and smooth with using extra cement laid in panels with necessary formwork complete all as specified and as directed by Engineer in charge.
M & L for coloured chequered cement concrete tiles 300 x 300 x 25 mm thick, set and jointed neat cement slurry and pointed with coloured or grey cement match with pigment, over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc. complete all as specified and as directed by Engr-in-Charge
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer in charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer in charge
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer in charge
M&L for Plain Cement concrete Nominal mix type D2 1:4:8 using 40 mm graded aggregate in foundations,filling and mass concrete including formwork complete all as specified and as directed by Engineer in charge
M & L for providing Plain Cement Concrete 1:3:6, type C2 (using 40 mm graded stone aggregate) as in surface channel and drains etc complete all as specified and as directed by Engineer in charge
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and as directed by Engineer in charge
M & L for extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and as directed by Engineer in charge
M & L for setting coat 3 mm thick in CM 1:2 ,trowelled to even and smooth finish complete all as specified and directed complete all as specified and as directed by Engineer in charge
M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) all as specified complete all as specified and as directed by Engineer in charge
Supply only water proofing compound
M & L for Preparation of old plastered wall surfaces and applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over old surfaces complete all as specified and as directed by Engineer in charge
M&L for 75mm thick Plain Cement Concrete Nominal mix (1:3:6) type C-2 (40 mm graded stone aggregate) as in sub-base including formwork complete all as specified and directed by Engineer in Charge.
M&L for 100mm thick Plain Cement Concrete Nominal mix (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floor/hard-standing/path finished even and smooth without using extra cement including necessary formwork complete all as specified and directed by Engineer in Charge.
M&L for Plain Cement Concrete Nominal mix type B1(1:2:4, using 20mm graded stone aggregate) as in edging including formwork complete all as specified and directed by Engineer in Charge.
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer in Charge.
M& L for Machine pressed precast conctete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed by Engineer in Charge.
Excavation in trenches, n.exe 1.5 m wide and n.exc 1.5 in depth, for foundation, etc or to shafts, wells, cesepits, manholes, piers holes, ec, n.exc 10 sq.m on plan and n.exc 1.5 m in depth and getting out in hard dense soil complete all as specified and directed by Engineer in Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, terminal/junction box etc and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer in Charge.
M&L for taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and directed by Engineer in Charge.
M&L for taking down unserviceable main switches ,DBs and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and directed by Engineer in Charge.
Material & Labour for Modular point wiring with two single core PVC insulated and unsheathed 1100 volts grade cable multistranded copper conductor of size 1.5 Sqmm nominal area(FRLSH) drawn through & including non metallic rigid PVC conduit, medium duty not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles , GI screws , rawl plugs with all fittings including tees , junction boxes & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable copper solid conductor of size 1.5 sqmm(FRLSH) complete all as specified and directed by Engineer in Charge. Note :- (i) Modular metal flush box and modular cover plate with frame will be measured and paid separately. (ii) The cost of cutting chases in wall/floor for concealed conduit and make good the surface shall deemed to be included in the quoted rates.
One light point controlled by one one way switch complete all as specified and directed by Engineer in Charge.
One ceiling fan point controlled by one switch complete all as specified and directed by Engineer in Charge.
One exhaust fan point controlled by one switch complete all as specified and directed by Engineer in Charge.
One 3 pin socket outlet 5 Amps independent complete all as specified and directed by Engineer in Charge.
One light point controlled by two 2-way switches complete all as specified and directed by Engineer in Charge.
All as per item No 50.00 here-in-before but cable with 2.5 sqmm for socket outlet 15 amps independent complete all as specified and directed by Engineer in Charge.
M&L for concealed submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two run of 1.5 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including non metallic rigid PVC conduit, medium duty not less than 25 mm dia concealed in wall/fixed on wall/ceiling with GI saddles, GI screws, rawl plugs with all fittings and one run of 1.5 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed. Note : Two run of single core cable with one run of earth continuity conductor and PVC conduit and its fittings will be measured as one length. (ii) Rates are deemed to be included for chases of conduit, cutting and making holes in wall/floor for passing in or through conduit and making good disturbed surfaces with existing wall colour complete
Supply & fixing modular switch one way, 6 Amps, 1 module, 240 volts complete all as specified and as directed
Supply & fixing modular switch one way, 16 Amps, 1 module, 240 volts complete all as specified and as directed.
Supply and fixing Modular switch 2 way 6A, 1 module, 240 volts complete all as specified and as directed.
Supply & fixing modular socket, 2/3 pin, 6 amps, 2 module complete all as specified and as directed.
Supply & fixing modular socket, 2/3 pin, 6/16 amps, 2 module complete all as specified and as directed.
Supply & fixing modular cover plate with frame 3 module complete all as specified and as directed.
Supply & fixing modular cover plate with frame 2 module complete all as specified and as directed.
Supply & fixing modular cover plate with frame 6 module complete all as specified and as directed.
Supply & fixing modular GI metal flush box 3 module not less than 1.2mm thickness complete all as specified and as directed.
Supply & fixing modular GI metal flush box 2 module not less than 1.2mm thickness complete all as specified and as directed.
Supply & fixing modular GI metal flush box 6 module not less than 1.2mm thickness complete all as specified and as directed.
Supply & fixing ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed.
Supply & fixing LED lights fitting 1x 20W, 2000lm, CDL, surge protection of 2 KV, 4 feet 220V, AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply & fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 1000lm, CDL, 220 V AC with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing surface LED down lighter 18W, 2000 lm complete all as specified and as directed.
Supply and fixing LED decorative post top LED fitting 35W with IP65 protection. Resistant to impact and corrosion. Glare free and better uniformity complete with all accessories all as specified and directed.
Supply & fixing ceiling fan 1200mm sweep with blades, down rods, electronic regulator and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, 5 star rated, equipped with brushless direct current motor (BLDC) including provision of cable from ceiling rose/connector to fan complete including taking down old unserviceable ceiling fan and deposited to MES store yard complete all as specified and as directed.
Supply & fixing exhaust fan metal body heavy duty 1400 RPM IP-55, AC, single phase, 230V, 380mm sweep complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner and provision of cable from ceiling rose/connector to fan including taking down old unserviceable exhaust fan and deposited to MES store yard complete all as specified and as directed.
Supply & fixing exhaust fan metal body heavy duty 1400 RPM IP-55, AC, single phase, 230V, 300mm sweep complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan including making good disturbed surface with existing wall colour and provision of cable from ceiling rose/connector to fan complete all as specified and as directed.
Supply & fixing LED high bay luminaire 110 W, 230V AC, recessed and square type with thermal management in multiple optics & IP 20 protection with impact and corrosion resistant with driver and lamp including mounting accessories complete all as specified and as directed.
Supply & fixing LED luminaire 600mm X 600mm, 36 watt, 220V AC, 3600 lm, 6500K, recessed type with high efficiency PMMA diffuser soft glare free light complere with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing LED building security light fitting 25 watt, 230V AC, 2500lm, outdoor type, pressure die cast housing with epoxy powder coated, dark graphite grey colour finish, poly carbonate cover with individual LED lenses with IP 65 protection with 10 KV SPD complete all specified and as directed.
Supply and fixing GI bracket, light grade 25 mm dia ISI marked and 50 cm long including two numbers GI clamp fixed on wall with necessary fixing arrangement complete all as specified and as directed.
Supply and fixing Polycarbonate cable junction box of size 104 x 104 x 70 mm, IP 66 with terminals totally shock proof, water proof, halogen free, silica and having thermally embedded gasket technology fixing on wall with two way 5 amp connector complete all as specified and as directed
Supply and fixing MCCB DB VTPN 4 way IP-54, IK-09 made of sheet steel phos phatised, powder painted with copper bus bar 250A, neutral link, earth bar and Din rail 415 Volts with double door, suitable for MCCB 4 Pole 63 Amps as incomer and MCB Single Pole as outgoing complete all as specified and as directed. Note: (i) MCCB and MCB will measured and paid separately. (ii) Cost for concealed the DBs on wall including making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate.
Supply and fixing MCCB 4 Pole, 415V, thermal adjustable type, 63 Amps with breaking capacity 16 KA complete all as specified and as directed.
Supply and fixing MCB SP 6-32 Amps ,10 KA, 'C' Curve, 230 Volts ,50 HZ complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 32X6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete
Material and labour for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall / plinth beam using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and drilling & plugging 12mm dia holes at every 300mm c/c along the perimeter and pumping chemical emulsion at the rate of 2.25 litres per linear meter complete all as specified and directed by Engineer-in-Charge.
Material and labour for Post anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-Charge.
M/s Ramesh Lal
DEEPAK AGENCIES
M/s Harjas Construction & Waterproofing Co
Ashini Infratech Private Limited
M/s K Moorthi
Nirman Construction Company
BISAKHA PLUMBING WORKS
bansal construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .