| Sl No | Description | Qty | Unit | MSR INFRATECH L2 | UNIVERSAL INFRAPROJECT PVT LTD L1 | M/S ROHIT CONSTRUCTION L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. | 12 | CUM | 180 ₹2,160 | 200 ₹2,400 | 150 ₹1,800 Lowest |
| 2.00 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed | 6 | CUM | 80 ₹480 | 70 ₹420 Lowest | 100 ₹600 |
| 3.00 | Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. | 6 | CUM | 80 ₹480 | 70 ₹420 Lowest | 100 ₹600 |
| 4.00 | M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed.
Note:- Punned thickness of sand shall be measured and paid. | 5 | CUM | 550 ₹2,750 | 400 ₹2,000 | 300 ₹1,500 Lowest |
| 5.00 | M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. | 9 | CUM | 1,250 ₹11,250 | 800 ₹7,200 Lowest | 800 ₹7,200 Lowest |
| 6.00 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed. | 0.2 | CUM | 5,500 ₹1,100 | 8,000 ₹1,600 | 4,500 ₹900 Lowest |
| 7.00 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed. | 2 | CUM | 5,500 ₹11,000 | 6,000 ₹12,000 | 4,500 ₹9,000 Lowest |
| 8.00 | M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed. | 8 | CUM | 2,850 ₹22,800 Lowest | 6,500 ₹52,000 | 3,000 ₹24,000 |
| 9.00 | M&L for providing precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings kneelers, apex stones, pier caps, columns, posts, boundary pillars,bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling) corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified and directed. | 1 | CUM | 5,500 ₹5,500 | 7,000 ₹7,000 | 4,500 ₹4,500 Lowest |
| 10.00 | M&L for Precast Reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar work including necessary form work and set in CM 1:4 complete all as specified and directed. | 0.5 | CUM | 5,500 ₹2,750 | 7,000 ₹3,500 | 4,500 ₹2,250 Lowest |
Tender Value
₹46.3 L
EMD Value
₹92,600
Closing Date
15 Nov 2025, 6:00 pmClosed
GE(S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
SPECIAL REPAIR OF BUILDING NO P-146 JCO MESS NEAR HQ SWC AND STORE ROOM OF BUILDING NO P-187 AND P-189 IN TPT COY ASC (CIV GT) UNDER GE (S) JAIPUR AT MIL STN JAIPUR
2025_MES_735964_1
GE(S)/J-65P/2025-26 8437/E8
Open Tender
Civil Works
Item Rate
180 days
GE(S) Jaipur
Class D and category a(i)
8 documents required · 8 mandatory
₹500
GE(S) Jaipur
₹92,600
Yes
27 Dec 2025
18 Oct 2025
22 Nov 2025
18 Oct 2025
15 Nov 2025
3 Nov 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed.
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed
Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed.
M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid.
M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings kneelers, apex stones, pier caps, columns, posts, boundary pillars,bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling) corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified and directed.
M&L for Precast Reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar work including necessary form work and set in CM 1:4 complete all as specified and directed.
M&L for providing precast cement concrete louvres and jallies 25 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed.
M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts and similar work complete all as specified and directed. Note :- Reinforcement and form work shall be measured and paid separately.
M&L for chipping of plaster / unsound weak and cracked concrete / cover of reinforcement of RCC member like slab, beam, column, chhaja etc or as per site requirement by standard power driven percussion type or pneumatic chisel including tapering all edges, making square shoulder of cavities etc and disposal of debris / malwa from site complete all as specified and directed.
M&L for cleaning of existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and applying two coats of alkline rust converting primer on the existing rebar and allowing it to react with rust for 6 hours and form corrosion resistant, insoluable and adherant protective layer, including cleaning the reinforcement wire brushing to remove the rust spalls, with time interval of 1 hour between the coats complete all as specified and directed.
M&L for corrosion inhibiting impregnation coating, designed for use as an imregnation for protection of steel reinforcement within unexposed concrete with in consumption of 0.5 Kg/Sqm. The product should be amino alcohol and inorganic combination based migratroy corrosion inhibitor for both cathodic and anodic protection complete all as specified and directed. Make : Fosroc / Thermax / Sika or equivalent as approved by GE.
M&L for zinc rich epoxy anti-corrosive protective coating for rebar corrosion protection system complete all as specified and directed. Make : Fosroc / Thermax / Sika or equivalent as approved by GE.
M&L for providing, mixing & applying two component of epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturer specification including prepartion of surface by chipping and throughly cleaning of surface complete wherever required complete all as specified and directed. Make : Fosroc / Thermax / Sika or equivalent as approved by GE.
M&L for re-building the section of damaged RCC elements to its original size on an average 15 mm thickness in two layers each by providing and applying with pre- batched, polymer modified mortar of approved make having compressive strength not less than 50 N/sqmm (28 days) as per ASTM C-109 and flexural strength not less than 05 N/sqmm (7 days) as per ASTM C-293-79 standards including water fog curing to keep surface moist for seven days complete all as specified and directed. Make : Fosroc / Thermax / Sika / Dr. fixed or equivalent make as approved by GE. Note : (i) To achieve the required thickness, the above process should be repeated after 24 hours. (ii) Surface area with 15mm thick layer will be measured as one unit for payment purpose. (iii) Rate shall be including all necessary scaffolding upto height of four storey building.
M&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L Brick work using old size bricks with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:6 complete all as specified and directed.
M&L for cutting holes into or through stone walls built in cement mortar or cement lime mortar and walls of cement concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required for superficial area exc 150 sq. cm but not exc 400 sq. cm complete all as specified and directed.
M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed.
M&L 15-16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed.
Taking down chowkats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frames) including making good of disturbed portion except space for holdfast complete all as specified and directed.
Taking down chowkats or frames exc 1.5 sqm but not exc 4.0 sqm each with shutters (without taking off shutters from the frames) and removing to or from store complete all as specified and directed.
S&F second class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed.
S&F second class hard wood 35 mm thick plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of 12 mm veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and directed.
S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Taking down shutters of any description exc. 1.00 Sqm but n.exc. 2.00 Sqm each complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, S & F in the frame as shown on drawing in section 8 of SSR-2020 Part-II complete all as specified and directed.
S&F for solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplied and fixing in opening as specified and shown on drawing made on section 8 of SSR 2020 Part-II complete all as specified and directed
S&F Factory made Solid PVC Moulded door shutter with Wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick moulded Prelam PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F in repair stainless steel handles, fancy type, of 200 mm size complete all as specified and directed. Make : Ebco / Hettich / Ultima / Hafele or equvalent make as approved by GE.
S&F in repair stainless steel (SS) tower bolts, fancy type, of size 150 mm long complete all as specified and directed. Make : Hafele / Hettich / Ultima or equivalent make as approved by GE.
S&F aluminium, anodised, barrel tower bolts of extruded section 150 mm long complete all as specified and directed.
S&F aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy of 250 mm length of bolt complete all as specified and directed.
S&F butt hinges, medium weight, cold rolled mild steel 100 mm long complete all as specified and directed.
S&F aluminium handles cast type anodised of 125 mm size complete all as specified and directed.
S&F aluminium handles cast type anodised of 150 mm size complete all as specified and directed.
S&F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges etc complete as all specified and directed.
S&F floor door stopper of brass body and tongue with hard drawn steel spring overall length of cover plate 140 mm complete all as specified and directed.
S&F in repair door closer hydraulically regulated designation No 3, universal type, suitable for door shutter of weight between 61 to 80 Kg of aluminium (die cast) body complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples including removing MS screws and welding if required over steel window and removing aluminium clips / PVC beads in aluminium window and UPVC window complete all as specified and as directed.
M&L for cupboard magnet, stainless steel, bright finish or electro-galvanised of size 55 x 29mm complete all as specified and directed . Make : Godrej, Hafele,Ultima,Hettich
M&L for cupboard lock, stainless steel, bright finish or electro-galvanised of size 64mm complete all as specified and directed .
S&F 25 mm dia stainless steel, silver & chrome finish, fancy type, anti-rust curtain rod complete as all specified and directed.
S&F stainless steel, curtain rod holder, fancy type for 25mm dia curtain rod complete as all specified and directed.
M&L in repair for auto close hinges, stainless steel, bright finish or electrogalvanised fixed complete all as specified and as directed.
S&F mild steel framed work for windows grills such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors / window and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long and 5 to 10 mm dia of shank complete all as specified and directed.
Mild Steel Fe-410-W Gde E-250 or Fe-290 Gde E-165 round bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F rolled mild steel section as in joist ,channel,angle or tee sections fixed independently ,with out connecting plates etc (cut to ordinary length i.e within 20 mm of the length indicated) of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed
S&F rolled mild steel section in framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provision of binding wire complete all as specified and directed
S&F Galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of posts, straining bolts,standard bolt, including securing or tying at crossing with and including provision of galvanized mild steel wire staples or steel pins, etc complete all as specified and directed (Each line of wire to be measured for the purpose of payment).
M&L for powder Coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F powder coated (thickness of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, side hung / sliding type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21, 100 mm long (2 No) , suitable handle (1 No) complete all as specified and directed.
M&L anodised aluminium snap grid frame work (size of grid 605 x 605mm) for false ceiling with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. Note : Design and pattern of grid shall be approved by Engineer-in-Charge.
Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed.
S&F aluminium expanded metal for securing wiremesh over gauzed shutter complete all as specified and directed.
M&L for applying fibre reinforced, single component, elastomeric liquid applied water proofing coating in white colour, anti-fungal, anti-algae, resistance to water and ageing, excellent UV resistant having Solar Reflective Index more than 105, with PU hybrid polymers and reinforcing acrylic fibers, elongation greater than 300% and applied in three layer complete all as follow :- (a) Preparation of surface by cleaning and removing loose particles then apply first coat of liquid water proofing after diluting as per manufacture instruction as a primer and allow the surface to dry for minimum 10 to12 hours complete all as specified and directed. (b) Apply second coat of liquid water proofing without dilution on the primed surface and allow time to dry the surface for minimum 10 to12 hours complete all as specified and directed. (c) Apply third coatof liquid water proofing without dilution over the second coat and allow minimum 48 hour complete all as specified and directed. Note : (i) Work shall be carried out by authorised applicator of manufacturer only and contractor will submit MoU with authorised applicator of manufacturer before execution of work. (ii) Material incorported in the work shall be calculated as per site requirement and full quantity of material shall be brought at site before execution of work. (iii) Necessary gurantee for 05 years shall be submitted by the contractor. Make :- Berger-HS Roof Kool & Seal, STP-Shali Urethane (R) BTD Plus, Asian - Smart care Damp Proof Ultra or equivalent make as approved by GE.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for complete removal of existing water proofing treatment from roof with wire brushes, dismantling of brick tiles and padding of any description and in any position upto mother slab of roof including cleaning ,sweeping and removing all dust / dirt by sweeping and cleaning with water and taking down debries from roof and removing the same outside the MD land complete all as specified and directed.
M&L 10 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi nium framework with screws complete all as specified and directed .
M&L for 0.9 mm thick decorative laminate type-1 of surface finish, colour and pattern as approved, fixed with approved adhesive complete all as specified and directed.
M&L for 18-20 mm thick High Density high moisture resistant (HDHMR) board for kitchen cupboard / door shutter of make Action tesa / Pearlwood or equivalent make as approved by GE, one side colour / white laminate and other side decorative as in modular kitchen / cabinets / door shutter fixed with minifix hardware wherever required including edge band 22mm wide, 0.80mm thick of matching colour on exposed surfaces of board fixed with polymaster adhesive of REHAU make or equivalent including trimming edges of edge band to true line of thickness of board by manual trimmer, fixed to wall etc. complete all as specified and directed.
M&L for 8 mm thick HDHMR (High density high moisture resistant) board of Action tesa / Greenply or equivalent make both side white laminate as in back of kitchen cabinets/portion of cupboard etc complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate, 50 mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed.
M&L for surface preparation by removal of all loose particle to ensure clean , smooth and dry surface and laying PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate 25 mm thick as roof padding to cover negative slope into prop and including WPC as per manufacturer instructions, surface finished even and fair without using extra cement complete all as specified and directed.
M&L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished area of each tiles exceeding 0.42 sqm but not exceeding 1.0 sqm in vertical surface such as dado /skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 10 mm thick rendering on stone/brick wall in CM 1:4 complete all as specified and directed.
M&L for machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing on treads of step and landing of stair including screed bed 20 mm thick in CM 1:6 complete all as specified and directed.
M&L for machine cut kota stone slab mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) in riser of step ,skirting, dado and pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including rendering 10 mm thick in CM 1:4 complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L for 75 mm thick Cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for 75 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm / 450X 350X 7 mm / 300x 600x7 mm / 450x 300x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in CM 1:4 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed 15 mm thick in CM 1:6 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for full body vitrified Ceramic tiles light shade cut out of 10mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 sqm in vertical surface such as dado / skirting / risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for full body vitrified Ceramic tiles light shade 10mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed or bedding layer 15 mm thick in CM 1:6 complete all as specified and directed.
M&L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished area of each tiles exceeding 0.42 sqm but not exceeding 1.0 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed or bedding layer 15 mm thick in CM 1:6 complete all as specified and directed.
S&F for rubber moulded machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
M&L for chequered cement concrete tiles 25 cm x 25 cm x 22 to 25 mm thick set, jointed and pointed in neat cement slurry as in floors with grey cement and no pigments over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:3 on concrete surface of roof to receive water proofing treatment finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:3 as in ceiling surface and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering on stone masonry or other than fair faces of brick work of wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on CM 1:4 on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing wall in two layer , first layer 10 mm thick in CM 1:4 even and fair, and second layer 05 mm thick in CM 1:4 surface finished even and smooth including integral water proofing compound at rate of 03% by weight of cement or as per manufacturer specification complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old surface of wall of any description and applying two coats of oil bound distemper (OBD) over a coat of alkali-resistant priming paint over and including 1 mm thick wall putty all as specified and directed.
M&L for preparation of new surface of wall of any description and applying two coats of oil bound distemper (OBD) over a coat of alkali-resistant priming paint over and including 1 mm thick wall putty all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling by complete removal of existing treatment and applying two coat of oil bound distemper (OBD) over a coat of alkali resisting priming paint over and including 1mm thick wall care putty complete all as specified and directed.
M&L for preparation of new surface of ceiling of any description and applying two coats of oil bound distemper (OBD) over a coat of chalk whiting on plastered surfaces preparatory to distempering over and including 1 mm thick wall putty all as specified and directed.
M&L for preparation of new surface of walls of any description with a coat of 1 mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed. Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE. Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work upto four storey building etc.
M&L for complete removal of existing treatment and preparation of old surface of wall of any description with a coat of 1 mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed. Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE. Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work upto four storey building etc.
S&F 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new or previously untreated plastered or concrete surface of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F for 15mm bore dia of pipe brass CP kitchen sink cock for water screwed down for iron pipe complete all as specified and directed. Make : Jaquar, Kohler , Grohe
Dismantling of AC/PVC water tank and S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position complete all as specified and directed.
M&L for Double Wall Corrugated (DWC) pipe of class SN-4, IS-16098 (part-II) of 150mm bore (internal), laid to slope in trenches, jointed complete with coupler, bends, Tee, reducers etc and tested complete all as specified and directed. Make : Ultra plus of Supreme / Corfit of Prince / D-Rex of Astral or equivalent as approved by GE.
M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed.
M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed.
M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 75 mm bore of pipe etc complete all as specified and directed.
M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore without access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore without access door complete all as specified and directed.
S&F PVC (SWR) junction single,(Single T) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single,(Single T) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single,(Single T) equal or unequal of 110 mm bore of pipe with access door complete all as specified and directed.
S&F PVC (SWR) junction single,(Single T) equal or unequal of 75 mm bore of pipe with access door complete all as specified and directed.
M&L PVC (SWR) reducers 110 mm to 75 mm complete all as specified and directed.
M&L PVC (SWR) vent cowl 75 mm complete all as specified and directed.
M&L PVC (SWR) vent cowl 110 mm complete all as specified and directed.
M&L in repair PVC (SWR) multi floor trap of diameter of outlet 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
S&F in repair bib taps cast copper alloy with crutch or butterfly handle, long body, screwed down, screwed for iron pipe or for brass ferrule fancy type chromium plated of 15 mm bore dia of pipe complete all as specified and directed.
S&F in repair for 15mm bore dia of pipe brass CP swan neck, wash hand basin mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed. Make : Jaquar CAT Part No OPP-CHR-15011BPM / Kohler CAT Part No 22534IN-4-CP / Grohe CAT Part No 32851000 or equivalent as approved by GE.
S&F in repair for 15mm bore dia of pipe brass CP wall mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed.
S&F in repair stop cock cast copper alloy, screwed down, high pressure with crutch or butterfly handle chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe complete all as specified and directed.
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of 15 mm bore dia of pipe complete all as specified and directed.
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of 20 mm bore dia of pipe complete all as specified and directed.
S&F PVC connection 15 mm size bore with PTMT nuts of length 450 mm complete all as specified and directed.
M&L for Stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore of pipe complete all as pecified and directed.
M&L for Stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore of pipe complete all as pecified and directed.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes, including fixing cantilever brackets and connecting union to pipe, overall size 915 mm x 460 mm, bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
M&L in repair wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe also including plastic water closet seat, black/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, excluding flushing cistern and flush pipe complete all as specified and directed.
S&F in repair Water closet vitreous china squatting pan, orissa pattern 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) and including provision of lime concrete bedding ,'P' or 'S' trap 100 mm bore , flushing pipe ,anti-syphonage pipe and connection etc and making good to floor complete all as specified and directed.
M&L in repair for Vitreous China urinals, bowl type flat back size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as sapecified and directed.
S&F in repair PVC 10 litres capacity valveless ,syphonic action type low level flushing cistern ,white including flush pipe, inlet, ball valve, float and handle etc complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125 mm size with or without swivel joint complete all as specified and directed.
M&L in repair for vitreous china wash basin, white,flat back, size 550 x 400 mm with brackets, including PVC connection of 450 mm long, PVC (HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc. complete all as specified and directed.
M&L for vitreous china wash basin, white,flat back, size 550 x 400 mm with pedestal, brackets, including PVC (HDPE) 32 mm bore waste pipe, Waste coupling of PTMT (half or full threaded) etc. complete all as sapecified and directed.
S&F in repair Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repair angle cock cast copper alloy for 15 mm bore dia of pipe screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repair bib taps 2-in-1 cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fancy type of 15 mm bore dia of pipe complete all as specified and directed. Make : Jaquar CAT Part No KUP-CHR-35041PM / Kohler CAT Part No 25432IN-4-CP / Grohe CAT Part No 20281000 or equivalent as approved by GE.
S&F in repair chromium plated soap dish holder complete all as specified and directed. Make:- Jaquar CAT Part No. ACN-CHR-1131N / Grohe CAT Part No. 1024612430 / Kohler CAT Part No. K-5634IN-CP / Roca CAT Part No. RF9060A1 or equivalent as approved by GE.
S&F in repair angle stop valve, fancy type chromium plated cast copper alloy, for 15 mm bore dia of pipe screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. Make:- Jaquar CAT Part No OPP-CHR-15053PM / Kholer CAT part No. 11568IN-7B-CP / Grohe CAT Part No 2201600M or equivalent as approved by GE.
S&F in repair waste coupling of brass CP for 32 mm bore dia of pipe half or full threaded with long shank complete all as specified and directed.
S&F in repair float corner glass shelve 8 mm thick 250 mm radius complete all as specified and directed. Make:- Jaquar CAT Part No. ACN-CHR-1173 or equivalent model of make Grohe / Kohler / Roca as approved by GE.
S&F in repair chromium plated towel ring round (20cm dia) / square (20cm x20cm) shape (minimum weight 300gm) with round flange complete all as specified and directed.
S&F in repair LED fixtures 20 Watt with extruded polycarbonate, environmental friendly, slim design with decorative and caps, high performance diffuser for soft & glare free light, minimum lumen output 1900 lm with efficacy 110 lm/w, driver with high voltage protection upto 380 V AC & surge protection upto 2.5 KV, CCT(K)-6500, LM 80 tested high brightness LED technology complete all as specified and directed. Make : Havells Cat Part No. LHEXARP7IN1W020 or equivalent model of Wipro / Crompton / Philips as approved by GE.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for point wiring complete with 1.5 Sqmm single core (Phase - Red, Neutral - Black) PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade PVC insulated and unsheathed cable inclosed in and including concealed PVC conduit 20 mm dia medium grade with all accessories ISI marked, including MS sunken box / modular metal flush box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting fitting like switches, sockets fan regulators etc. including 1.5 Sqmm single core (Green colour) PVC insulated unsheathed copper earth continuity conductor FRLS cable 1100 V grade as continuous earth wire for one light / fan / bell point controlled by one, one way switch. Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonry and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sqmm (Green), concealed in wall and drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS sunken box modular metal flush box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for one 3 pin socket outlet 5 Amps on the same board with other switches, complete all as specified and as directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sqmm (Green), concealed in wall and drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS Sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3 pin 5 Amps socket outlet on independent board, complete all as specified and directed. Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 Sqmm (Green), concealed in wall, drawn into and including rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS Sunken box / modular metal flush box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3 Pin 15 Amps socket outlet on independent board, complete all as specified and directed. Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate.
S&F switch piano, flush type, 6 amps single pole, one way, complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 16 Amp complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
S&F modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S&F fan step regulator, 120W - 2 module complete all as specified and directed.
M&L in repair for sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed FRLS copper cable 1100 V grade with multistranded copper conductor ISI marked drawn through and including PVC rigid conduit / casing capping not less than 20mm and conduit accessories fixed on surface of wall / celing etc including provision of 1 Run of 6 Sqmm PVC insulated unsheathed FRLS cable with multistranded copper conductor as earth continuity complete all as specified and directed. Note : 02 Run of 06 Sqmm copper wire and 01 Run of 06 Sqmm copper earth wire along with PVC conduct shall be measured as one unit.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and directed. Note : Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
S&F in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single Pole and 06 to 32 Amp current carrying capacity complete with connection testing and commissioning all as specified and directed.
S&F in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN and 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
S&F in repair sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB of capacity 20 Amps complete all as directed.
S&F exhaust fan, steel body AC single phase, 230V of size 450 mm sweep heavy duty with, blades, and frame and louvers complete all as specified and directed.
M&L in repair for earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:3:6) type B-1 using 20mm graded stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1 using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm bore GI Pipe medium grade for watering complete all as shown in electrical plate No 3 of SSR Part-I(2009) and connected to earth test point including testing complete all as specified and directed. Note :- 1. PCC Chammer shall be constructed atleast 2.5 metre away form the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner. 2. GI wire and protection pipe upto 7.5 meter from the earth plate electrode is deemed to be included in quoted rate. 3. Excavation for earthing to be done manually and Earth resistance below 3 Ohm should be obtained after measurement for every pit.
M&L in repair for earthing with galvanised iron earth plate electrode 600mm x 600 mm & 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below Ground level, connected to GI strip 32x6 mm (up to 7.5 metre) by means of GI nuts, bolts & washers ,earth strip protected with & including 40 mm dia light grade GI pipe (up to 7.5 metre) all as shown in electrical plate No 3 of MES Schedule Part I, with & including PCC 1:3:6 type C1 for pit with cover of 50 mm thick RCC 1:1.5:3 type A1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20 mm GI medium grade pipe , GI funnel with GI mesh, filling with common salt & charcoal in alternate layers, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as specified and directed. Note :- 1. The insulation procedure shall be followed as per instruction of the earth electrode manufacturer. 2. GI pipe of suitable size for protection against mechanical damage of main earth strip from earth electrode to test point up to 7.5 metre to be provided. The cost for the same shall be deemed to be included in the qouted rate. GI strip & GI protection pipe beyond 7.5 metre shall be measured & paid separately. 3. If desired earth resistance is not obtained during testing ,the earthing shall be redone with out any extra cost.
S&F electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. complete all as specified and directed. Note:- Connection with geyser inlet and outlet with 15mm bore GI pipe including PVC pipe is included in the quoted rate.
S&F in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.(Note:- Bracket along with screw to fix on wall/surface will be included in above quoted rate.)
S&F in repair LED lights fitting 1x20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
M&L in repair for LED light fitting 9W / 10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
M&L lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F modular switch one way 6 A, 1 module complete all as specified and directed.
S&F modular bell push 6A, 1 module complete all as specified and directed.
S&F Bell Ding Dong AC 230 volts, single pole complete all as specified and directed.
S&F modular Socket, 6A - 2/3 pin combined, 2 module complete all as specified and directed.
S&F socket outlet 3 pin, 16 Amp, flush type complete all as specified and directed.
S&F socket outlet 2 in 1,3 pin, 6 Amp complete all as specified and directed.
S&F in repair sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 8 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed.
S&F in repair sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 12 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed.
S&F in repair sheet metal enclosure factory fabricated for MCB distribution board TPN double door type concealed in wall 415 volt 4 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed.
S&F ceiling rose 3 phase, PVC / polycarbonate, isolated body complete all as specified and directed.
Fixing / hanging ceiling fan any sweep and connecting up including PVC flexible three core cable with copper conductor of size 16 / 0.20 mm from ceiling rose to fan of sufficient length and connecting complete all as specified and directed. Note : Old fan obtain from taking down shall be refixed.
Fixing or hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan and including painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. Note : Old fan obtain from taking down shall be refixed.
Fixing only exhaust fan any sweep and connecting up including PVC flexible three core cable with copper conductor of size 16 / 0.20 mm from ceiling rose to fan of sufficient length and connecting complete all as specified and directed. Note:- Old exhaust fan obtain from taking down shall be refixed.
Taking down ceiling fan / exhaust fan any type, sealing cable end, dismantling blades, regulator and removing fan, blades and regulator to MES store complete all as specified and directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep with minimum air delivery 210 cubic meter per minute (CMM) with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note:- The rate quoted by contractor shall deemed to be included for the followings : (i) The colour BLDC Fan shall be pearl white. (ii) Proper hanging arrangement like 0.45 meter down rod, canopy etc. (iii) Writing the Fan No. on fan body. (iv) Making connection with 1.5 Sqmm copper wire complete all as directed.
S&F exhaust fan, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep of size 250mm complete all as specified and directed.
S&F in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) of triple pole neutral (TPN) and 63 Amp current carrying capacity in the DB complete with connection testing and commissioning all as specified and directed.
S&F in repair LED street / security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness, laid bedded and pointed in any mortar in floor, apron etc complete all as specified and directed.
Dismantling of stone slabs of any description or thickness, laid bedded and pointed in any mortar in floor, apron etc complete all as specified and directed
Demolition of cement concrete un-reinforced in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
Demolition of reinforced cement concrete (RCC) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removal of rubbish from site complete all as specified and directed.
Dismantling of boarding, any description, fixed in any position with nails etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of AC corrugated / semi corrugated or translucent sheet as in roof coverings complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
MSR INFRATECH (BID ID -3477500)
M/S ROHIT CONSTRUCTION (BID ID -3479857)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
8437Tender.pdf
Tender Documents • 1.04 MB
BOQ_824100.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .