| 1 | L1₹48.2 CrAccepted-AOC BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹48.2 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹50.1 CrRejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹50.1 Cr | L2 | Rejected-Finance Not being L1 Bidder |
| 3 | L3₹50.2 CrRejected-Finance | ₹50.2 Cr | L3 | Rejected-Finance Not being L1 Bidder |
| 4 | L4₹50.8 CrRejected-Finance F 18 ANSAL COMPLEX OPP JWALA HARI MARKET PASCHIM VIHAR NEW DELHI 110063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹50.8 Cr | L4 | Rejected-Finance Not being L1 Bidder |
| 5 | L5₹50.9 CrRejected-Finance 421 4TH FLOOR TOWER A 2 SPAZE ITECH PARK SECTOR 49 SOHNA ROAD GURGAON | GURUGRAM | HARYANA | 122001 | ₹50.9 Cr | L5 | Rejected-Finance Not being L1 Bidder |
Tender Value
₹56.9 Cr
EMD Value
₹15 L
Closing Date
9 Sept 2024, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
CONSTRUCTION OF CERTAIN TECHNICAL AND DOMESTIC INFRASTRUCTURE AT AF STN JORHAT (PHASE -II)
2024_MES_652070_1
88658/B/JOR/E8
Open Tender
Civil Works
546 days
GE(P) No 2 (AF) CHABUA
As per NIT conditons
8 documents required · 8 mandatory
₹3,000
GE (P) NO 2 (AF) CHABUA
₹15 L
Yes
30 Oct 2024
3 May 2024
11 Sept 2024
5 Jun 2024
9 Sept 2024
29 Jul 2024
Amount
NOTE (Applicable for all Parts/ Items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced Schedule is given in tender documents
SCHEDULE "A" PART-II (EARTH WORK AND EXCAVATION) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/HARDSTANDING/SLAB CULVERT) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART-X (LIGHTENING PROTECTION) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART -XI (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
S & F modular metal flush box with modular white cover plate with frame, 8 module complete all as specified and directed .
S & F modular metal flush box with modular white cover plate with frame, 6 module complete all as specified and directed .
S & F modular metal flush box with modular white cover plate with frame, 3 module complete all as specified and directed .
S&F LED light fittings 4 feet, 1 x 20 W, 220 V AC decorative box type with driver including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED light fittings with high output diffuser 2 feet, 1 x 10 W, 220 V AC decorative type with driver including LED lamp, connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED light fittings 4 feet, 1 x 40 W, 220 V AC decorative box type with driver including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F sheet metal enclosure for MCB DB single pole and neutral 6 way with 200 Amps rated bus bar, neutral link, dinrail suitable for mounting MCB's 240 volts double door type complete all as specified.and directed Note:- MCB's are measured and paid in separate items
S&F MCB SP 63 Amps (C-Curve), breaking capacity 10 kA, 240 volts complete all as specified and directed.
S&F Energy efficient five star rated, 26 to 32 Watts, with three blades ceiling fan 230 volts, single phase AC, 1200 mm sweep, BEE 5 star rated, Brushless Direct Current(BLDC) without remote type with accessories like holding down rod,hanging clamps, blades, fan hook including writing MES number (as per standard practice) including provision of three core flexible copper wire of suitable size from ceiling rose to ceiling fan complete in all respect all as specified and directed.
S&F exhaust fan metallic steel body, single phase, 230 volts, 50 Hzs of size 300mm sweep, 900/950 RPM, copper wound, 3 blade, double ball bearing, heavy duty type with suitable metallic louver, blades, frame and flexible three core copper conductor cable of suitable size for connecting with ceiling rose complete all as specified and as directed.
Material & Labour for 300 mm thick(compacted thickness) GSB (Granular sub base) grade V as per table 400-1 of MORTH, IRC specification, spreading in layers n.exc. 75 mm thick in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 8 to 15 tonne static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and as directed. directed
M & L for 350mm thick Pavement Quality Concrete (PQC) work in Pavement of minimum field flexural strength 45 Kg/Sqcm (lower control limit) LCL after 28 days of pavement slab using minimum 360 Kg Ordinary Portland Cement Grade 43 per cum with not exc 31.5mm graded crushed stone aggregate conforming to IS: 383 (grading and other parameters as specified in PS) and mixed with non circular synthetic fibre reinforcement @ 0.25% of weight of ordinary portland cement grade 43 of PQC or as per manufacturers instuction, mixed in batching plant transported to site, laid in panels, spread and compacted using slip form sensor paver , mechanically vibrated and bull nosing / rounding off the edges, curing compund, finishing the surface by belting and brooming without using extra cement etc including necessary form work etc complete all as specified and directed.
S & F for speed bump made from heavy duty ABS, UV stablised black and yellow combination, high reflective reflection having Length-70mm, width-23mm available on both sides in red , yellow colour (H=75mm, W=750mm, L=250mm )complete all as specified and as directed.
M&L for bringing approved earth/moorum/red bajri from outside MOD land and deposited where directed including raising (or lowering) earth, spreading in layer n.exc 30cm thick, watering, ramming/ rolling and finished to required gradient, size and shape etc, n.exc 1.50m high from the base complete all as specified and as directed. Note: (i) Payment shall be made for solid quantity arrived consolidation. (ii) Before execution of this earth shall be tested/ checked for suitabilty to use as IS specification.
M&L for soil stabalization of 300mm in two layers each 150mm thick sub grade soil by uniform mixing of cement OPC 43 grade/lime/other additive @2% cement by weight of soil (Percentage of cement/additives for estimation purposes only , type of additive and percentage required for blending shall be in mix design). Item shall incle pulverization of soil, spreading of additive, blending mix by tractor towed rotovator, addition of water/drying of mix to be required moisture content and compaction using suitable vibratory roller to required 95% maximum Dry Density, Provisions of IRC SP 89-2010 shall be refrerred to for this item, complete all as specified and as directed. Note: (i) Payment shall be made for solid quantity arrived consolidation. (ii) Before execution of this earth shall be tested/ checked for suitabilty to use as IS specification. (iii) Soil required shall be brought from outside MOD land.
Construction of RCC septic tank conventional type designed to carry sewage and sullage water, excavation in ordinary soil, foundation PCC (1:4:8) type D2 (using 40mm graded stone aggregate), RCC M-30 (design mix) using 20mm graded stone aggregate for RCC wall,base slab,baffle wall and roof slab incl beam etc vent shaft,manhole openings with cover connection etc complete with effective depth of 1.50m and overall depth of 3.0m for 50 users complete all as specified and as shown on drawings.
M & L Soakage wells for 50 Users, excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as shown in drawing complete all as specified and as directed.
Supply , installation and Testing of hi wall split units indoor/outdoor complete with cordless remote control unit and with in-built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and min EER 5.0.of capacity 2 TR incl shed for outdoor unit and sufficient lenght of copper pipe complete all as specified and as directed.
Supply , installation and Testing of hi wall split units indoor/outdoor complete with cordless remote control unit and with in-built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and min EER 5.0.of capacity 1.5TR incl shed for outdoor unit and sufficient lenght of copper pipe complete all as specified and as directed.
S & F Voltage stabilizer for automatic operation,single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with output voltage stabilzed at 230 V with accuracy of ± 2.5 % and of capacity 5.0 KVA complete all as specified and directed.
S & F Voltage stabilizer for automatic operation,single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with output voltage stabilzed at 230 V with accuracy of ± 2.5 % and of capacity 4.0 KVA complete all as specified and directed.
S&F Metal plug and socket assembly, Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 6-32 Amp 'C' curve fixed flush to wall complete all as specified and directed
M & L for feather -kites specical coated wall mounting stand suitable for 1.5 to 2 TR split AC outdoor unit consisting of bracket-02 Nos, Angle iron -02 Nos M8 x 50mm , anchor fastener -06 Nos complete all as specified and directed
Supply and install steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP - 31 (9 metres long) including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of red oxide primer, externally from top of coping complete all as specified and as directed. (Note :- Excavation, PCC foundation and coping shall be measured and paid separately.)
S & F DWC pipe 40mm dia bore,light grade, with all fittings laid in tenches, for mechanical protection of earth strip of earthing etc complete all as specified and as directed.
Demolition of concrete (asphatic concrete/ PCC) of any description and in any position not otherwise speciifically provided for and removing the demolished materials to a distance exc. 500mtr but n exc. 1.5 km and depositing where directed complete all as specified and as directed.
Supply, Erecting, Testing and Commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 40 KVA, Water Cooled, 415 Volts(AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Jorhat. (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,Suitable No of cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 40 KVA at outdoor atmospheric conditions at Jorhat. ,(Taking all derating factor into consideration), , 12/24 Volt(as per manufacturer's recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer's instructions and including suitable panel with techometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .
Item No 11.29 and 11.30 Contd ..... (v) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002. (vii) External cubicle Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set. (viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. (ix) Factory Test shall be carried out by testing officer nominated by AO. (x) Pre- commissioning test shall be carried out by testing officer nominated by Accepting Officer.” (xi) The drawings for PCC foundation for DG set as per OEM recommendations shall be submitted to GE for approval.
Supply, installation, commissioning and testing of 11 KV, 3 phase, 3 wire, 50 Hz, Indoor type, 630 Amp, 350 MVA, with 01 incomming and 01 outgoing facility VCB Panels Including Adaptor Panel to connect with existing VCB panels boards horizontal draw out horizontal isolation floor mounting manually operated panel with 230 Volt motor mechanism & 24V DC shunt/ close coil and other fittings & accessories. 26.3 kA breaking capacity for 3 Sec, totally enclosed with extended copper busbar of 630 Amps for each phase metal clade , indoor extensible type flush front, horizontal isolation, horizontal draw out type with electrical and mechanical interlock and automatic safety shutter gare including pad locking arrangement, isolation plug assemble with Vacuum interrupters with each pole individually encapsulated by epoxy insulations to make it dust proof and self aligning finger type isolation contacts, truck having integral racking with necessary interlocks ( for insertion and removing of VCB) manual and automatic moter charge independent closing / tripping spring, trip free operating mechanism with closing and tripping push bottens and mechanical breaker interconnected with HT sleeve, copper bus bur of 630 Amps including all prospection , indication , operation, monitoring and control and accessories as per specification. Closing and tripping coil of VCB shall be of continuous rating to achieve minimum failure. 11 KV Epoxy Resin Cast Current Transformer CT Ratio : 100-50/5+5A,Core I CL 1.0 with 15 VA burden for metering, Core II CL 5P 10 With 15 VA burden for Protection 11 KV Epoxy Resin Cast Potential Transformer Ratio : 11/ √3 KV/110/ √3V, 3 Phase, Draw out Type, Core I : CL 1.0 with 100 VA burden for metering & Protection The CB shall be provided with Voltmeter 0-12 KV Amphere meter.
Supply, installation, commissioning and testing of 11 KV, indoor type, 630 Amp, 350 MVA 05 Nos. VCB Panel Board (having 2 Nos. Incoming Panels, 2 Nos. Outgoing Panels & 1 No. Bus Coupler) horizontal draw out horizontal isolation floor mounting manually operated panel with 230V motor mechanism & 24V DC shunt/ close coil and other fittings & accessories.26.3 kA breaking capacity for 3 Sec, totally enclosed with extended copper busbar of 630 Amps for each phase metal clade , indoor extensible type flush front, horizontal isolation, horizontal draw out type with electrical and mechanical interlock and automatic safety shutter gare including pad locking arrangement, isolation plug assemble with Vacuum interrupters with each pole individually encapsulated by epoxy insulations to make it dust proof and self aligning finger type isolation contacts, truck having integral racking with necessary interlocks ( for insertion and removing of VCB) manual and automatic moter charge independent closing / tripping spring, trip free operating mechanism with closing and tripping push bottens and mechanical breaker interconnected with HT sleeve, copper bus bur of 630 Amps including all prospection , indication , operation, monitoring and control and accessories as per specification .Closing and tripping coil of VCB should be of continuous rating to achieve minimum failure. 11 kV Epoxy Resin Cast Current Transformer CT Ratio : 100-50/5+5A,Core I CL 1.0 with 15 VA burden for metering, Core II CL 5P 10 With 15 VA burden for Protection 11 KV Epoxy Resin Cast Potential Transformer Ratio : 11/ √3 KV/110/ √3V, 3 Phase, Draw out Type, Core I : CL 1.0 with 100 VA burden for metering & Protection.
Item No 11.34 & 11.35 Contd ..... Note :- (i) The contractor shall submit QAP (Quality Assurance Programme) within 15 days after placement of order for VCB for testing of equipments at factory. VCB shall be despatch only after inspection at manufacturer premises shall be done by OEM Auth and MES auth at manufacture premises. (ii) Contractor shall furnish original Purchase Voucher of the VCB manufacturer. (iii) Contractor shall make all the testing arrangement and arrange all the testing tools @ 2 times (at the timde of commissioning and against at the time of SEI inspection for pre-commissioning test and testing at site before operation of VCB) without any extra cost. All the installations and testing tyo be done in presence of /by OEM representative. (iv) Suitable RCC platform for outdoor installation with height as required at site to mount the VCB as per manufacturer's recommendations. (v) Contractor shall produce general arrangement drawing and technical specifications for approval before placing order. (vi) Factory test shall be carried out by Testing Officer nominated by Accepting Officer. (vii) Pre-commissioning test shall be carried out by SEI/EI/ESO as per policy issued by E-In-C's Branch letter No 36323/Gen/CEI/E4(U) dated 30 May 2023.
Item No 11.37 Contd ..... (j) Breaker Control switch (k) Push buttons for check trip circuit healthy and emergency trip. (l) Switch for closing/tripping of VCB (m) Alarm annunciator for DC supply fail/trip (n) Power pack of suitable capacity with I/P voltage 220 V AC and O/P voltage 110 V DC (o) Other standard accessories as specified by OEM. Current Transformer –Cast resin Ratio: 50-25/5-5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA-01 Nos Indication Lamps :VCB off / on / auto trip/ Trip circuit healthy/spring charge indication- 1Set Metering : Digital Ammeter & Digital Volt Meter- 1Set Transformer Section 500 KVA, 11/0.433 KV, “BIS Marked & BEE Star Labelled” Copper Wound Oil Cooled Step Down Off Load Tap Changer (OCTC) Transformer (7 position having tapping range +7.5% in steps of 2.5% each) with all standard fittings & accessories including OTI, WTI & Marshalling Box (as per IS-1180:2014 EEL-2 with amendment no.- 1,2,3 & 4) Formerly EEL-3 (till 30.3.2022) with and including Auxilary relays, winding temperature indicator, master trip relay and all standard relays accessories etc for making the system complete as per prevailing IS/BEE.
Item No 11.37 & 11.38 Contd ..... LT Section Incoming – 800 Amp 4P Air Circuit Breaker microprocessor based with O/L S/C & E/F Protection – 01 No. Outgoing – 100 Amp 4 Pole MCCB with thermal magnetic based release with O/L &S/C protection – 02 No. 200 Amp 4 Pole MCCB with thermal magnetic based release with O/L & S/C protection – 01 No. 800 Amp 4 Pole ACB with thermal magnetic based release with O/L & S/C protection – 01 No. 800A/5A LTCT Cl:1.0 -03 Nos Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LTCubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control--02 Set MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel.- 02 Set Provision for receiving Incoming cables through Bottom entry and out going through Bus bar to Trf panel, Excluding Termination Kit & Glands. Provision for receiving Incoming through bus duct by bus bar and Outgoing through cable box bottom entry Excluding Termination Kit & Glands-02 Set Bus Bar – Aluminium , Earth Bus –Aluminium-02 Set Paint shade: Siemens Grey ( RAL 7032) Note:- (i) Rate are inclusive of foundation as per OEM recommendation , testing and commissioning of the above item (ii) The warranty of the complete switchgears such as VCB, Transformer/CSS, LT Panel and enclosure shall be OEM responsibility.
Item No 11.37, 11.38 & 11.39 Contd ..... Note :- (i) The contractor shall submit QAP (Quality Assurance Programme) within 15 days after placement of order for CSS for testing of equipments at factory. CSS shall be despatch only after inspection at manufacturer premises shall be done by OEM Auth and MES auth at manufacture premises. (ii) Contractor shall furnish original Purchase Voucher of the Transformer manufacturer. (iii) Pre-commissioning test shall be carried out by SEI/EI/ESO as per policy issued by E-In-C's Branch letter No 36323/Gen/CEI/E4(U) dated 30 May 2023. (iv) Cost of hiring T & P and all testing equipments at site required for testing of plant (v) Suitable RCC platform for outdoor installation with height as required at site to mount the Transformer as per manufacturer's recommendations.
Item No 11.41 Contd ..... (j) Breaker Control switch (k) Push buttons for check trip circuit healthy and emergency trip. (l) Switch for closing/tripping of VCB (m) Alarm annunciator for DC supply fail/trip (n) Power pack of suitable capacity with I/P voltage 220 V AC and O/P voltage 110 V DC (o) Other standard accessories as specified by OEM. Current Transformer –Cast resin Ratio: 50-25/5-5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA-01 Nos Indication Lamps :VCB off / on / auto trip/ Trip circuit healthy/spring charge indication- 1Set Metering : Digital Ammeter & Digital Volt Meter- 1Set Transformer Section 1000 KVA, 11/0.433 KV, “BIS Marked & BEE Star Labelled” Copper Wound Oil Cooled Step Down Off Load Tap Changer (OCTC) Transformer (7 position having tapping range +7.5% in steps of 2.5% each) with all standard fittings & accessories including OTI, WTI & Marshalling Box (as per IS-1180:2014 EEL-2 with amendment no.- 1,2,3 & 4) Formerly EEL-3 (till 30.3.2022) with and including Auxilary relays, winding temperature indicator, master trip relay and all standard relays accessories etc for making the system complete as per prevailing IS/BEE.
Item No 11.41 & 11.42 Contd ..... LT Section Incoming – 1600 Amp 4P Air Circuit Breaker microprocessor based with O/L S/C & E/F Protection – 01 No. Outgoing – 100 Amp 4 Pole MCCB with thermal magnetic based release with O/L &S/C protection – 01 No. 200 Amp 4 Pole MCCB with thermal magnetic based release with O/L & S/C protection – 02 No. 1250 Amp 4 Pole ACB with thermal magnetic based release with O/L & S/C protection – 01 No. 1600A/5A LTCT Cl:1.0 -03 Nos Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LTCubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control--02 Set MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel.- 02 Set Provision for receiving Incoming cables through Bottom entry and out going through Bus bar to Trf panel, Excluding Termination Kit & Glands. Provision for receiving Incoming through bus duct by bus bar and Outgoing through cable box bottom entry Excluding Termination Kit & Glands-02 Set Bus Bar – Aluminium , Earth Bus –Aluminium-02 Set Paint shade: Siemens Grey ( RAL 7032) Note:- (i) Rate are inclusive of foundation as per OEM recommendation , testing and commissioning of the above item (ii) The warranty of the complete switchgears such as VCB, Transformer/CSS, LT Panel and enclosure shall be OEM responsibility.
Item No 11.41. 11.42 & 11.43 Contd ..... Note :- (i) The contractor shall submit QAP (Quality Assurance Programme) within 15 days after placement of order for CSS for testing of equipments at factory. CSS shall be despatch only after inspection at manufacturer premises shall be done by OEM Auth and MES auth at manufacture premises. (ii) Contractor shall furnish original Purchase Voucher of the Transformer manufacturer. (iii) Pre-commissioning test shall be carried out by SEI/EI/ESO as per policy issued by E-In-C's Branch letter No 36323/Gen/CEI/E4(U) dated 30 May 2023. (iv) Cost of hiring T & P and all testing equipments at site required for testing of plant (v) Suitable RCC platform for outdoor installation with height as required at site to mount the Transformer as per manufacturer's recommendations.
M&L for loose filling of hard core packed aggregate exceeding 63 mm but not exc 100mm size up to the height of 15 cm thick, around the two pole structure and existing transformer/2 pole/4 pole structure after leveling the ground for flooring with plain cement concrete 1:4:8 Type -D2 (40mm graded stone aggregate) up to the height of 10 cm complete all as specified and as directed. Note : ( Before filling up of aggregate, the suface shall be prepared for preventing grass growth around the equipment/structure )
Item No 11.46 Contd ..... PROTECTION:- (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency. (iv) Single phase Prevention. (v) Spike and surge protection. (vi) Earth Fault protection. (vii) Test Reports as per clause 11.1 for any rating as per clause 5.1 from BIS: 9815 (Part –I) re-affirmed 2004. (aa) Physical eximation (ab) Insulation resistance. (ac) High Voltage Test (ad) leakage current test. (ae) Provision of earting. (af) Output voltage. (ag) No load current. (ah) measurmet of no load losess. (aj) include voltage test.
Item No 11.48 Contd ..... PROTECTION:- (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency. (iv) Single phase Prevention. (v) Spike and surge protection. (vi) Earth Fault protection. (vii) Test Reports as per clause 11.1 for any rating as per clause 5.1 from BIS: 9815 (Part –I) re-affirmed 2004. (aa) Physical eximation (ab) Insulation resistance. (ac) High Voltage Test (ad) leakage current test. (ae) Provision of earting. (af) Output voltage. (ag) No load current. (ah) measurmet of no load losess. (aj) include voltage test.
Item No 11.50 Contd ..... PROTECTION:- (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency. (iv) Single phase Prevention. (v) Spike and surge protection. (vi) Earth Fault protection. (vii) Test Reports as per clause 11.1 for any rating as per clause 5.1 from BIS: 9815 (Part –I) re-affirmed 2004. (aa) Physical eximation (ab) Insulation resistance. (ac) High Voltage Test (ad) leakage current test. (ae) Provision of earting. (af) Output voltage. (ag) No load current. (ah) measurmet of no load losess. (aj) include voltage test.
Item No 11.52 Contd ..... PROTECTION:- (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency. (iv) Single phase Prevention. (v) Spike and surge protection. (vi) Earth Fault protection. (vii) Test Reports as per clause 11.1 for any rating as per clause 5.1 from BIS: 9815 (Part –I) re-affirmed 2004. (aa) Physical eximation (ab) Insulation resistance. (ac) High Voltage Test (ad) leakage current test. (ae) Provision of earting. (af) Output voltage. (ag) No load current. (ah) measurmet of no load losess. (aj) include voltage test.
Supply , Installation, Commissioning and Testing of 500 KVA Isolation transformer, Three Phase, Oil cooled, copper wound including first filling of oil of requiste di-electric strength as per IS-335, 50 Hz, AC, Oil Cooled Isolation Transformer, with enclosure, suitable for out door use in a maximum ambient temperature of 45 Deg C, bearing IS 1180 : 2021 (Revised) & IS 11171 , "Primary : 415 V + 1%, 3 Phase, 50 Hz, AC, Secondary : 415 V + 1%, 3 Phase, 50 Hz, AC, Connection : Delta – Star, Vector Group : Dyn 11, Insulation : Class ‘H’ complete all as specified and as directed yo collect unbalance type, frequency 50 Hz +/-3%, di-electric strength 2.5 KV for 60 seconds. Insulation shall be more than 1000 Mega Ohms, impedence Voltage:3-4% and comprises with the following :- (a) Standard fittings and fixtures with provision for over load short circuit, light low cut off, single phase seqence change (b) Surge protection against load surges, insulation class 'A' digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal -02 Nos, lifting eye/plugs, under carriage with 04 x Nos of bi-diectional rollers, separate neutral brush. Note : (i) Pre-despatch inspection at OEM/factory premises shll be carried out by Rep of Accepting Officer (ii) Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer (iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/ESO/EI. (FOR SITE NO 6)
Supply , Installation, Commissioning and Testing of 1000 KVA Isolation transformer, Three Phase, Oil cooled, copper wound including first filling of oil of requiste di-electric strength as per IS-335, 50 Hz, AC, Oil Cooled Isolation Transformer, with enclosure, suitable for out door use in a maximum ambient temperature of 45 Deg C, bearing IS 1180 : 2021 (Revised) & IS 11171 , "Primary : 415 V + 1%, 3 Phase, 50 Hz, AC, Secondary : 415 V + 1%, 3 Phase, 50 Hz, AC Connection : Delta – Star, Vector Group : Dyn 11, Insulation : Class ‘H’ complete all as specified and as directed yo collect unbalance type, frequency 50 Hz +/-3%, di-electric strength 2.5 KV for 60 seconds. Insulation shall be more than 1000 Mega Ohms, impedence Voltage:3-4% and comprises with the following :- (a) Standard fittings and fixtures with provision for over load short circuit, light low cut off, single phase seqence change (b) Surge protection against load surges, insulation class 'A' digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal -02 Nos, lifting eye/plugs, under carriage with 04 x Nos of bi-diectional rollers, separate neutral brush. Note : (i) Pre-despatch inspection at OEM/factory premises shll be carried out by Rep of Accepting Officer (ii) Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer (iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/ESO/EI. (FOR SITE NO 4)
Supply , Installation, Commissioning and Testing of 25 KVA Isolation transformer, Three Phase, Oil cooled, copper wound including first filling of oil of requiste di-electric strength as per IS-335, 50 Hz, AC , Oil Cooled Isolation Transformer, with enclosure, suitable for out door use in a maximum ambient temperature of 45 Deg C, bearing IS 1180 : 2021 (Revised) & IS 11171 , "Primary : 415 V + 1%, 3 Phase, 50 Hz, AC, Secondary : 415 V + 1%, 3 Phase, 50 Hz, Connection : Delta – Star, Vector Group : Dyn 11, Insulation : Class ‘H’ complete all as specified and as directed yo collect unbalance type, frequency 50 Hz +/-3%, di-electric strength 2.5 KV for 60 seconds. Insulation shall be more than 1000 Mega Ohms, impedence Voltage:3-4% and comprises with the following :- (a) Standard fittings and fixtures with provision for over load short circuit, light low cut off, single phase seqence change (b) Surge protection against load surges, insulation class 'A' digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal -02 Nos, lifting eye/plugs, under carriage with 04 x Nos of bi-diectional rollers, separate neutral brush. Note : (i) Pre-despatch inspection at OEM/factory premises shll be carried out by Rep of Accepting Officer (ii) Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer (iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/ESO/EI. (FOR SITE NO 4)
Supply , Installation, Commissioning and Testing of 50 KVA Isolation transformer, Three Phase, Oil cooled, copper wound including first filling of oil of requiste di-electric strength as per IS-335, 50 Hz, AC Oil Cooled Isolation Transformer, with enclosure, suitable for out door use in a maximum ambient temperature of 45 Deg C, bearing IS 1180 : 2021 (Revised) & IS 11171 , "Primary : 415 V + 1%, 3 Phase, 50 Hz, AC, Secondary : 415 V + 1%, 3 Phase, 50 Hz, Connection : Delta – Star, Vector Group : Dyn 11, Insulation : Class ‘H’ complete all as specified and as directed yo collect unbalance type, frequency 50 Hz +/-3%, di-electric strength 2.5 KV for 60 seconds. Insulation shall be more than 1000 Mega Ohms, impedence Voltage:3-4% and comprises with the following :- (a) Standard fittings and fixtures with provision for over load short circuit, light low cut off, single phase seqence change (b) Surge protection against load surges, insulation class 'A' digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal -02 Nos, lifting eye/plugs, under carriage with 04 x Nos of bi-diectional rollers, separate neutral brush. Note : (i) Pre-despatch inspection at OEM/factory premises shll be carried out by Rep of Accepting Officer (ii) Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer (iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/ESO/EI. (FOR SITE NO 4)
Supply and laying Sub-Class ' B' bricks, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm, Indoor/Outdoor type complete all as specified and as directed.
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm, Indoor/Outdoor type complete all as specified and as directed.
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 sqmm, Indoor/Outdoor type complete all as specified and as directed.
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 400 sqmm, Indoor/Outdoor type complete all as specified and as directed.
Supply and fixing cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 sqmm complete all as specified and as directed.
Supply and fixing cable jointing kit for 33 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 240 Sqmm, Outdoor type complete all as specified and as directed.
Supply & Installation of Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED( 80-100)microns with pure Zinc (99.9%) & ALLOY COATING (200-250) microns. Earthing System confirming IS 3034:1987. The outer and inner pipe shall be 76.3 mm & 41.9 mm 3 mtrs Length, Zinc coated with additional special Alloy coating 300mm on the top side for additional corrosion protection of the Terminal. The annular space between the pipes shall be filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes shall not disintegrate or collapse when outer pipe corrodes. The inner pipe shall be extended with terminals for connectivity. The job includes digging the pits and refilling the same by Conductolite Back Fill compound (Ground Enhancer), the BFC shall be eco friendly. It shall not contain environmentally hazardous material/metal having RoHS Certification from NABL accredited lab. Good earth shall be arranged to fill the excavated pits by mixing the same with BFC 2 bags (each bag contains 25 kgs of BFC) including FRP(fiber reinforced plastic) cover having high mechanical strength, chemical resistance able to bear 2 TON of loads with detachable easy locking lid complete all as specified & directed. Model no- ASEEL_39-ZC & AC (76.3mm dia)
Boring of holes under road, pavement, hard standing for protection of pipe upto 100mm bore, not exceeding 10.00 mtr in a single length without damaging the existing road , getting out and disposal of excavated soil to a distance not exc 50 mtr from the site of work complete all as specified and directed.
M & L for cutting road, pavement, hard standing etc and making good distrubed surface, finishing with PCC (1:3:6)type C-2 using 40mm graded stone aggregate for fixing the pipe, getting out and disposal of excavated soil to a distance not exc 50 mtr from the site of work complete all as specified and directed.
M & L for Relaying and Rerouting after pulling out the cable from trenches/road crossing/from the circular pipe/duct etc without damaging the cable and cleaning/straightening of cable if required at site of serviceable HT/LT UG cable of any size and any capacity complete all as specified and directed. (Note:- Excavation, sand, bricks and connected items shall be measured and paid separately).
S&F Cable Junction Box 200X160X98mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat iron clamps of size 25x3mm, nuts, bolts, washers etc. including applying Two Coats of Synthetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer complete all as specified and as directed.
Supply, laying and testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 33000 volts grade, of size 3 core 240 sq mm, complete all as specified and as directed.
M&L for PVC sheathed copper cable of 1.5 sqmm, 3 core for street light / Dwarf light connection on pole from junction box to light fitting complete all as specified and as directed.
S&F steel tubular pole 2 Mtr long including necessary reducer,bracket ,clamp,nut bolts and screws and welding of base plate of suitable size in pole including painting of pole with two coats of aluminium paint over a coat of primer, bracket is suitable for fitting 35 watt led street light complete all as specifed and as directed.
Supply, fixing, grouting and painting HT/LT cable route indicator made up of Factory made Precast RCC slab of size Length 15 inch ( 38.1 cm), Width 6 inch (15.24 cm) and height 4 feet (121.92 cm) duly engrave as PH-I BK-II with red color and engrave as IACCS with YELLOW color and also Size of Cable and grouting on the route of HT/LT cable complete all as specified and as directed. Note :- (i) Unit rate of item includes excavation, PCC foundation for erection of route indicator (ii) Slab of route indicate shall be provided with min 4 Nos x 8 mm diameters TMT bars along length of slab with 7 Nos cross bar 6 mm dia in reinforcement with shuttering (iii) Route indicator RCC slab shall be painted with two coats of red/blue colour synthetic enamel paint over a one coat of white primer base complete all as specified and directed.
Dismantling of street light poles/dwarf light pole of any type and any length from existing position andshifted to MES store yard and making good disturbed surfaces complete all as specified and as directed.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR SITE NO 6)
Item No 11.75 Contd...... BUS-BAR CHAMBER : Copper bus bar 1200 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) ACB 800 amps, 415 volt, 50 kA breaking capacity, Fixed type, 4 pole duly connected to bus bar as incoming - 01Nos. OUTGOING/INDICATING DEVICES : (i) MCCB 320 amps, 415 volt, 36 kA breaking capacity 4 pole, Thermal magnetic , duly connected to bus bar as outgoing - 02 Nos.( one spare) (ii) MCCB 250 amps, 415 volt, 36 kA breaking capacity 4 pole, Thermal magnetic , duly connected to bus bar as outgoing - 02 Nos. (iii) MCCB 63 amps, 415 volt, 25 kA breaking capacity 4 pole , Thermal magnetic , duly connected to bus bar as outgoing - 01 No. (iv) Digital Multifunction meter, Model C, class 1, with relay - 01 No, with Suitable CT and wiring. (v) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR SITE NO 4)
Item No 11.77 Contd...... BUS-BAR CHAMBER : Copper bus bar 1900 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) ACB 1250 amps, 415 volt, 50 kA breaking capacity, Fixed type, 4 pole duly connected to bus bar as incoming - 01 Nos. OUTGOING/INDICATING DEVICES : (i) MCCB 320 amps, 415 volt, 36 kA breaking capacity 4 pole, Thermal magnetic , duly connected to bus bar as outgoing - 04 Nos. (ii) MCCB 250 amps, 415 volt, 36 kA breaking capacity 4 pole, Thermal magnetic , duly connected to bus bar as outgoing - 02 Nos. (One spare) (iii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR FU-1, TECH SET UP , SCP & LRSR, WATCH TOWER)
Item No 11.79 Contd...... BUS-BAR CHAMBER : Copper bus bar 150 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) MCCB 100 amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 80 amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing- 02 Nos ( one spare) (ii) TPN MCB 25 Amp - 03 Nos (One Spare) (iii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR 30 KW load at site No 6)
Item No 11.81 Contd...... BUS-BAR CHAMBER : Copper bus bar 100 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) MCCB 63 amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 63 amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing- 01 Nos (ii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iii) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR 120KW load at site No 4 & 6)
Item No 11.83 Contd...... BUS-BAR CHAMBER : Copper bus bar 400 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) MCCB 250 Amps, 415 volt, 36 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 250 Amps, 415 volt, 36 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01 Nos (ii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iii) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR 150KW load at site No 4 & 6)
Item No 11.85 Contd...... BUS-BAR CHAMBER : Copper bus bar 500 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) MCCB 320 Amps, 415 volt, 36 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 320 Amps, 415 volt, 36 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01 Nos (ii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iii) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR Site No 4)
Item No 11.87 Contd...... BUS-BAR CHAMBER : Copper bus bar 150 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) MCCB 100 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 63 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01 Nos (ii) TPN MCB 32 Amp -01 No (for timer panel) (iii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR Site No 4 & 6)
Item No 11.89 Contd...... BUS-BAR CHAMBER : Copper bus bar 150 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) MCCB 100 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 63 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 02 Nos (One spare) (ii) MCCB 40 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01 Nos (iii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR Site No 4 & 6)
Item No 11.91 Contd...... BUS-BAR CHAMBER : Copper bus bar 200 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) MCCB 100 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 63 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 0 Nos (For voltage stablizer) (ii) MCCB 40 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01 Nos (For OTM of FU-1) (iii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
Supply , Fixing, Comissioning and Testing and of automatic street light switch of capacity 5 to 8 KW in three phase, using Nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contractor, MCB and support terminals enclosed in pole/ wall mounted enclouser made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP 54, including mounting arrangement with suitable size of FI clamps 02 Nos of 25 mmx3mm thickness, Bolts and nuts as required at site and connected to street light over head/under ground feeder with complete acessories complete all as specified and directed. The automatic switching unit shall comprising of the following: (i) Contractor rating (AC3) Three phase16-20 Amp (4 Pole) (ii) MCB 20 Amps(SP-3 Nos),10 KA ,240 volts-3 Nos . (iii) NATURESWITCH-01 Note- Price shall be inclusive of Sensor, Contactor, Incoming-Outgoing MCBs, Enclosure etc complete
Supply, installation, testing and commissioning of Outdoor type Automatic intelligent power factor corrector (APFC) capacitor bank panel floor mounted ,weather proof made out of 3.15 mm thick CRCA sheet , out door type and structure duly fixed on structural channel, fixed on ground with PCC( 1:2:4) Type B-1 (using 20mm graded stone aggregate) and finished the surface, the cubicle panel shall have enameled danger notice plate, duly painted with two coats of powder coated paint internally and externally on the surface complete all as specified and directed. The panel box shall be cubicle shaped with special type of hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements including necessary control circuit connections and necessary cable connections by lugs and glands , including provision for accommodating capacitor and the following electrical items:- Automatic power factor correction (APFC) Panel for 3 phase, 415 V & 50 Hz system of capacity 400 KVAR with 22 steps (2x50 + 2x30 + 4x25 + 4x15 + 6x10 + 4x5) with MDXL capacitor and controller complete all as specified and directed.
Supply, installation, testing and commissioning of Outdoor type Automatic intelligent power factor corrector (APFC) capacitor bank panel floor mounted ,weather proof made out of 3.15 mm thick CRCA sheet , out door type and structure duly fixed on structural channel, fixed on ground with PCC( 1:2:4) Type B-1 (using 20mm graded stone aggregate) and finished the surface, the cubicle panel shall have enameled danger notice plate, duly painted with two coats of powder coated paint internally and externally on the surface complete all as specified and directed. The panel box shall be cubicle shaped with special type of hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements including necessary control circuit connections and necessary cable connections by lugs and glands , including provision for accommodating capacitor and the following electrical items:- Automatic power factor correction (APFC) Panel for 3 phase, 415 V & 50 Hz system of capacity 200 KVAR with 8 steps (2x50 + 2x30 + 2x15 +2x5) with MDXL capacitor and controller complete all as specified and directed.
S & F for 15mm bore Angle cocks, fancy type chromium plated (Long body) cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and as directed.
Phoenix Infra (BID ID -3091565)
B D Raizada Projects Pvt Ltd (BID ID -3091629)
City Promoter and Buildwell Pvt. Ltd. (BID ID -3091658)
Aalaya Engineering Project Private Limited (BID ID -3077389)
M/S ALLIED CONSTRUCTION (BID ID -3091572)
SOOD ASSOCIATES PVT LTD (BID ID -3091767)
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED (BID ID -3091711)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid