Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical PLOT NO F28 COMPLETE COOLING SOLUTIONS LLP PHASE 8 INDUSTRIAL AREA SAS NAGAR MOHALI PUNJAB 160055 | S A S NAGAR | PUNJAB | 160055 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹73.8 L
EMD Value
₹1.5 L
Closing Date
18 Sept 2026, 11:00 amClosed
Executive Engineer Electrical Division HPPWD. Una
Executive Engineer Electrical Division HPPWD. Una
.
2026_PWD_143239_1
NIT No. 3953-70 dated 10/09/2026
Open Tender
Electrical Works
Percentage
90 days
Una
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
₹1.5 L
18 Sept 2026
11 Sept 2026
18 Sept 2026
11 Sept 2026
18 Sept 2026
11 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of DX type double skin air handling units (AHUs) each comprrsing of following as perthe specifications Casing of air handling units shall be in double skin construction. lnner skin shall be constructed out of 24 gauge plain GS sheet & outer skin in 24 gauge pre-plasticized GS sheet sandwitched between 50mm thick injected PU foam insulation of density not less than 40 Kg /CuM and complete with inspection doors and marine light, limit switch including control wiring as required. AHUs shall be provided with thermal break profile Fan section complete with backward curved DlDWtype centrifugal fan/s, lP-55, lE3, TEFC squirrel cage induction motor suitable to operate on 41-5+tO%Y,50H2,3 phaseACpowersupplyand belt drive package.Fan outlet velocity shall not more than 1800 FPM (9.2 MPS) Motors shall be VFD compatible.All fans should be AMCA certified. Fan section should be completed with 25mm thick Armasound acoustic insulation.Coil section with multirows deep DX type coil of copper tube & copper header and aluminium fins construction having wall thickness of tubes not less than 0.5mm. Drain pan shall be made out of 18 gauge stainless steel duly insulated. Facevelocity across cooling coil shall not exceed 500 FPM.Pre-Filter (EU-4) section complete with 50mm thick washable synthetic fibre filters. Velocity across the filters shall not exceed 500 FPM.AHUs shall be provided with mixing chamber with R/A & F/A openings withdampers as per approved shop drawing.ln addition to the above, air handling units shall be provided with fire retardent flexiblecanvassconnectionsmadeoutof canvas ssleeve.Sizesof airhandling units shall not exceed as mentioned in the design drawings and air handling units shallconform to the design parameters mentioned in specifications.The Air Handling Units (AHUs) shall be of followine dutv parameters: Make Edgetek, Sytemair,flakt, zeco.The rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax or other taxes as imposed by the Govt time to time where applicalble . | |||||
| 1.01 | AHU No Capacity S.P Motor Rows of
Area to (TR/ Cfm) (mmWG) Ratins coil be fed(HP)
AH-1 32 /10500 55
20 6 HALL | 2 | No | 6,28,869 | ₹12,57,738 |
| 1.02 | AHU No Capacity S.P Motor Rows of
Area to
(TR/Cfm) (mmWG) Rating coil be fed (HP)
AH-2 30/10000 55
20 6 HALL | 1 | No | 5,83,826 | ₹5,83,826 |
| 1.03 | AHU No Capacity S.P Motor Rows of Hall
Area to
(TR/Cfm) (mmWG) Rating coil be fed (HP)
AH-2 22/7000 55
20 6 HALL | 1 | No | 5,44,244 | ₹5,44,244 |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testlng of following nominal sizes of soft/hard drawn copper refrigerant plping for VRV/VRF system, corxplete with fittings, with suitable adjustable ring type hanger supports,jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cellelastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required to complete the job including five year on site warranty. The rates are inclusive of carriage of materials within all leads and lifts and alltaxes of octroi ,royallty, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalble . Make: Maxflow/Rajco metals /mehta tubes /Mandev/Metaco.The rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale or other taxes as imposed by the Govt time to time where applicalble . | |||||
| 2.01 | 50.8mm OD (Hard drawn), 1,62mm thick | 80 | meter | 4,575 | ₹3,66,000 |
| 2.02 | 44.45mm OD (Hard drawn), 1.62mm thick | 250 | meter | 4,048 | ₹10,12,000 |
| 2.03 | 38.1mm OD (Hard drawn), 1.62mm thick | 900 | meter | 3,384 | ₹30,45,600 |
| 3 | Supply, lnstallation, Testing and Commissioning of control cum transmission wiring of 2 corex 0.75 sq mm copper wire in suitable PVC conduits between indoor & outdoor units to central remote controllers & for connections between indoor unit to remote control comple in all respect The rates are inclusive of carriage of materials within all leads and lifts and alltaxes of octroi ,royallty, malkana, toll tax,sale tax or other taxes as imposed by the Govt time to time where applicalble . | 1,500 | meter | 119 | ₹1,78,500 |
| 4Supply, lnstallation, Testing & Commissioning of inline fans for exhaust air complete withsheet metal casing, 25mm thick acoustic insulation, direct driven centrifugal fan, motor with properprotection and inspectiondoor.Fan shall besuitableforoperationon220+6% volts, 50 Hz,1 phase AC power supply. Flanges to be provided on both sides to facilitate duct connections. Fan shall be installed as shown in the drawings and will be of following characteristics : All single phase inline fans shall be provided with factory fitted speed regulators. All Fans Should be complete with Plug Top & necessary power cable. Fans shall have Iow noise level in rage of 35-40dBA @3m and shall be suitable for indoor installations. including five year on site warranty, The rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi,royality, malkana, toll tax,sale tax or othertaxes as imposed by the Govt time to time where applicalble .Fan No. CapacityS.P Area to(Cfm) (mmWG) to be exhausted Make :- Kruger/ Greenheck/ System Air/N icotra/Airf low. | |||||
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
SBD.pdf
Tender Documents • 4.44 MB
undertaking.pdf
Additional Documents • 0.38 MB
BOQ_212813.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .