CWE AF BIKANER
HQ CWE AF BIKANER
REPAIR/ MAINT OF AC PLANT, CHILLER/ CONDENSER MOTOR, COOLING TOWER, DESCALING OF CONDENSER AND OTHER RELATED WORKS OF GE (AF) SURATGARH
2024_MES_672421_1
81581/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF SURATGARH
₹40,000
Yes
29 Jan 2025
5 Sept 2024
9 Oct 2024
5 Sept 2024
7 Oct 2024
24 Sept 2024
Amount
Cleaning and washing of microfilters of AHU of below given capacity up to the satisfaction of Engineer In Charge including any other minor repair needed in AHU. Any broken filter shall be replaced with new one and same shall be paid under relevant respective items.
Up to 10000 CFM
Above 10000 CFM to 20000 CFM
Cleaning of cooling tower with one or two as per existing size , water basin and makeup tank with the help of chemical and nylon brush,removing and refixing of PVC finches after washing, cleaning of condenser pipe line( in let and out let) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engr in charge and inside painting of water tank of cooling tower used water proof black japan paint one coat including changing of unserviceable PVC guard,water distributor, PVC pipe etc complete for the satisfaction of the Engr in charge of the following capacity of the AC plants at diffrent locations complete all as specified and as directed
Up to 30 TR
Above 30 TR to 60 TR
More than 60 TR
Removing old unserviceable port Y type strainer and material and labour for Y type strainer 150mm size of both end flanged including supply and welding flange of size 150mm two nos( if required) complete all as specified.
Removing old unserviceable port Y type strainer and material and labour for Y type strainer 100mm size of both end flanged including supply and welding flange of size 100mm two nos ( if required) complete all as specified.
Removing old unserviceable port Y strainer and material and labour for Y strainer 80mm size of both end flanged including supply and welding flange of size 80mm two nos ( if required) complete all as specified.
Removing old unserviceable port Y strainer and material and labour for Y strainer 65mm size of both end flanged including supply and welding flange of size 65mm two nos ( if required) complete all as specified.
Removing old unserviceable port Y strainer and material and labour for Y strainer 50mm size of both end flanged including supply and welding flange of size 50mm two nos ( if required) complete all as specified.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 150 mm complete all as specified and directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 100 mm complete all as specified and directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve of size 80 mm complete all as specified and directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 65 mm complete all as specified and directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 50 mm complete all as specified and directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 40 mm complete all as specified and directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 32 mm complete all as specified and directed.
Supply and fixing rotational moulded polythylene water storage tank tripple layered 5000 litres capacity (cylindrical vertaical with closed top) hoisted and fixed in position including taking down old water storage tank, complete all as specified and directed.
Supply and fixing rotational moulded polythylene water storage tank tripple layered 2000 litres capacity (cylindrical vertaical with closed top) hoisted and fixed in position including taking down old water storage tank, complete all as specified and directed. Note : for Srl item No 15.00 & 16.00 (i) Quoted rate shall including for making suitable connection of GI pipe. (ii) Old foundation for existing water tank to be demolished and new foundation to be made as per the OEM recommendation and Engineer-in-Charge direction, rate for the same shall be included in quoted rate.
Taking down old unserviceable pressure guage supply and fixing testing of pressure guage of 0 to 100 PSI complete all as specified and directed.
Providing and fixing in position the mercury-in- glass industrial type thermometers complete with fittings as directed.
Taking down old unserviceable/ broken pulley of AHU of any size and supply,fixing, testing and commissioning of new pulley suitable for any capacity AHU complete all as specified and as directed by Engineer in charge. Note : Any machining work needed at shaft of motor is also included in quoted rate.
Taking down old unserviceable AHU microfilters of any size and supply,fixing, testing and commissioning of new microfilters of existing size for any capacity AHUs complete all as specified and as directed by Engineer in charge.
Taking down old unserviceable/ torn out canvas cloth of any size and supply,fixing and testing of new canvas cloth for making connection between AHU and Duct suitable for any capacity AHU complete all as specified and as directed by Engineer in charge.
Taking down old unserviceable motor pump coupling set of any size and supply,fixing, testing and commissioning of new motor pump coupling complete set along with rubber star coupling suitable for any capacity centrifugal pump set complete all as specified and as directed by Engineer in charge.
Taking down old unserviceable motor pump coupling's star rubber of any size and supply,fixing, testing and commissioning of new motor pump coupling's star rubber set suitable for any capacity centrifugal pump set complete all as specified and as directed by Engineer in charge.
Preparation of old painted surface of MS pipes and painting with one coat of synthetic enamel paint, as per colour code given by the deptt , complete all as specified and as directed by Engineer-in-Charge. (Note :- The rates includes for writing and marking description of pipes with white enamel paint)
Taking down old unserviceable electric strip heater and Supply, installation, testing and commissioning of electric strip heater of 3 KW complete all as specified and as directed.
Taking down old rusted unserviceable MS/GI tray of any size and supply,fixing, fabricating, testing and commissioning of new GI tray of approximate size 50 Inches X 13 Inches and sides raised by 1 inch made of minimum 18 gauge GI with black bitumen coating suitable for any capacity FCU water drain purpose complete all as specified and as directed by Engineer in charge. Note : Size of tray is tentative and may vary as per site requirement. Any minor item needed like PVC pipes for water draining etc shall be included in quoted rate.
Taking down old unserviceable Fan coil unit of any size and supply,fixing, testing and commissioning of new Fan Coil Unit of 1200 CFM having single phase motor with double shaft complete all as specified and as directed by Engineer in charge.
Taking down old unserviceable Fan coil unit of any size and supply,fixing, testing and commissioning of new Fan Coil Unit of 1000 CFM having single phase motor with double shaft complete all as specified and as directed by Engineer in charge.
Labour only for Identification of breakdown of any type of AC Plants of any capacity and rectify the same with proper record mentioning time date and nature of defect duly signed by JE E/M and AGE E/M Note:- (1.) Spares required for major repair will be paid separately. (2.) Contractor will produce the register at the time of payment.
Taking down old unserviceable cooling tower motor's cover/ umbrella of any size and supply,fixing and testing of new mettalic cover of cooling tower motor for protection of motor from rain for any capacity cooling tower all as specified and as directed by Engineer in charge.
Supply and fixing PVC float valve high pressure with polythene float and fly nut complete screwed PVC pipe and fixed in 15mm/20mm/25mm dia bore pipe including taking down old unserviceable Float valve.
Supply and fixing low pressure switch/ high pressure switch of existing make and specifications including removing of refrigerent in empty cylinder and checking of pressure testing leak testing vaccum the system, charging the refrigerent in the system complete all as specified and as directed by the engr in charge.
Supply and fixing chilled water sensor as per existing specifications and make complete all as specified and directed by engr in charge.
Removing old unserviceable PVC finches supply and lying of PVC finches of size 300mmx200mmx150mm complete all as specified and as directed.
Taking down old unserviceable fan motor with fan blade of any size and supply and fixing, testing and commissioning of new fan motor along with fan blade of existing shape, size suitable for below given cooling tower capacities complete all as specified and as directed.
Up to 50 TR
More than 50 TR.
Taking down old unserviceable water sprinkler/ distribution system of any size and supply and fixing, testing and commissioning of new complete water sprinkler/ distribution system along with all connected accessories of existing shape, size suitable for below given cooling tower capacities complete all as specified and as directed. Note : Pipes shall be of thread type not shall be joined by solution but joined by screwing thread.
Up to 50 TR
More than 50 TR.
Taking out old unserviceable controller ( PLC based control module) and supply, fixing, testing and commissioning of new controller with digital display as per existing specifications and make suitable for below given capacities Central/ Package type AC unit complete all as specified and as directed. Note : This item includes complete controller including all connected equipments to make controller functional.
Up to 24 TR
Above 24 TR to 60 TR
Material and labour for arresting of leakage in copper tube of heat exchanger of AHU and chiller unit by first detecting & locating the number of leaks using an appropriate procedure(i.e soap solution or nitrogen ) & arresting the leakage by spot brazing of the tubes on site and then recheck the leakage through pressure test by nitrogen gas to the complete satisfaction of engr-in-charge
Taking down old unserviceable butter fly valve/ gate valve and material and labour for butter fly valve with rubber packing of size 25 mm complete all as specified and directed.
Labour only for arrangement of authorised engineer( service engineer of AC unit's company having suitable license) visit to identify the breakdown of any type of AC Plants and for PLC setting like temp/ voltage range setting and to carry out the neccesarry repair up to the complete satisfaction of Engineer in charge. Any minor item needed to repair shall be included in quoted rate.
Repair of the PLC based control module with digital display of Package/Central type AC unit suitable for any tonnage capacity having start/stop functions, settings option to change the settings as per requirement all as specified and directed by engr-in-charge.
Supply and charging of Refrigerent R-22 in sealed container of 45/60 kg complete all as specified and directed. Note: Contractor will have to use sealed container and have to show weight of container before and after gas charging, so that exact weight of gas can be calculated.
Supply and charging of Refrigerent R-407 C in sealed container of 45/60 kg complete all as specified and directed. Note: Contractor will have to use sealed container and have to show weight of container before and after gas charging, so that exact weight of gas can be calculated.
Removing old unserviceable thermal insulation and Supply and insulation of thermal insulation on ducts/chiller pipe line exposed to sun light using closed cell O nitrile rubber elastometric insulation of density 40-55 kg/m3, minimum thickness 20mm, thermal conductivity of 0.037 W/mk at 20 degree celcius mean temp and MZ 7000(without any additional vapour barrier) and with chemical treated factory laminated Woven fibre glass cloth with 200+/- 20 gsm to be applied on ducts manufactures reccomended rubber based adhesive in a blend of solvents complete as per specificaions.
Supply, instalation, testing and commissioning of acoustic insulation of pipe line with glass wool having thickness 25 mm resin bonded fibre glass of 48 kg/cum density, covered with and 28 G Aluminium perforated sheet complete all as specified.
Material and labour for replacement of Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from existing earth.
Taking down old unserviceable Air vent valve 15/20 mm and supply and fixing testing of air vent valve 15 mm complete all as specified and as directed.
Taking down old unservicable MCCB of any capacity and Supply, Fixing, testing of MCCB 3 Pole, 415 V, 63 Amps to 100Amps with breaking capacity 16 KA.
Taking down old unservicable MCCB of any capacity and Supply, Fixing, testing of MCCB 3 Pole, 415 V, Adjustable type, 160Amps with breaking capacity 36 KA.
Taking down old unservicable MCCB of any capacity and Supply, Fixing, testing of MCCB 3 Pole, 415 V, Adjustable type, 200Amps with breaking capacity 36 KA.
Taking down old unservicable MCCB of any capacity and Supply, Fixing, testing of MCCB 3 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA.
Taking down old unservicable MCCB of any capacity and Supply, Fixing, testing of MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 50 KA.
Supply and fixing, testing and commissioning power contactor of given specification and make used for running of AC unit's compressor or any other motor used for pumps, AHU blowers, cooling towers etc of below given capacities complete all as specified and as directed by Engr-in-charge.
Up to 15 Ampere.
Above 16 A to 30 A.
Above 30A to 60 A.
Supply & Fixing in replacement PVC insulated & PVC sheathed industrial submersible cable for pump motors, flat three core of nominal area of copper conductor 6 sqmm, 1100 volts, conforming to IS : 693, complete all as specified and as directed.
Supply & Fixing in replacement PVC insulated & PVC sheathed industrial submersible cable for pump motors, flat three core of nominal area of copper conductor 10 sqmm, 1100 volts, conforming to IS : 693, complete all as specified and as directed.
Supply & Fixing in replacement PVC insulated & PVC sheathed industrial submersible cable for pump motors, flat three core of nominal area of copper conductor 16 sqmm, 1100 volts, conforming to IS : 693, complete all as specified and as directed.
Material and labour in replacement for control wiring with single core copper cable of size 1.5 sqmm for main panel of AC plant, AC unit panel, AHU panel etc complete all as specified and directed.
Supply and fixing in replacement over load relay 6 to 15 Amp complete all as specified and directed by engr in charge.
Supply and fixing single phase preventor relay of existing sample as per site requirement complete all as specified and directed by engr in charge.
Material and labour for replacement of control wiring of AHU or AC Plant panel with suitable copper conductor with all necessary connections all as specified and directed by Engr-in-charge.
Disconnecting, dismantling the defective three phase induction motor 415 Volts 50 Hz of any RPM for following capacities, Servicing and re-winding with super enamelled copper wire of best quality of existing size/gauge and weight inciuding raplacement of insulation material,varnish bearing connection plate and all other petty items required to make the motor is functional and reassembling the motor including installation commissioning and testing on full load all as specified and as directed.
for motor of capacity up to 5 HP.
for motor of capacity 5 HP to 10 HP.
Disconnecting dismatling of centrifugal/ monoblock pump set of following capacities of any RPM and dismantling defective parts such as impeller nut, glant, impeller key, gland packing water deflector bush bearings sleeve, gaskets, volute stud and nuts suction and delivery flange and stud and nuts and all other petty items required to make the pumpset is functional and reassembling the pumpset including installation commissioning and testing all as specified and as directed
for pump of capacity up to 5 HP.
for pump of capacity 5 HP to 10 HP.
Material and labour for fan belt for using of AHU Motor, Package unit, any size any plant of compressor complete all as specified and as directed.
Supply, Laying and testing MS pipes heavy grades (ERW steel) including cutting, bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 150 mm as per IS 1239 (1981) fixed in replacement of existing u/s complete by cutting road and footpath and making surface good as previous all as specified and directed.
Supply, Laying and testing MS pipes heavy grades (ERW steel) including cutting,bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 100 mm as per IS 1239 (1981) fixed in replacement of existing u/s complete by cutting road and footpath and making surface good as previous all as specified and directed.
Supply, Laying and testing MS pipes heavy grades (ERW steel) including cutting,bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 80 mm as per IS 1239 (1981) fixed in replacement of existing u/s complete by cutting road and footpath and making surface good as previous all as specified and directed.
Supply, Laying and testing MS pipes heavy grades (ERW steel) including cutting, bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 65 mm as per IS 1239 (1981) fixed in replacement of existing u/s complete by cutting road and footpath and making surface good as previous all as specified and directed.
Supply, Laying and testing MS pipes heavy grades (ERW steel) including cutting, bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 50 mm as per IS 1239 (1981) fixed in replacement of existing u/s complete by cutting road and footpath and making surface good as previous all as specified and directed.
Supply, Laying and testing MS pipes heavy grades (ERW steel) including cutting,bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 40 mm as per IS 1239 (1981) fixed in replacement of existing u/s complete by cutting road and footpath and making surface good as previous all as specified and directed.
Supply, Laying and testing MS pipes heavy grades (ERW steel) including cutting,bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 32 mm as per IS 1239 (1981) fixed in replacement of existing u/s complete by cutting road and footpath and making surface good as previous all as specified and directed.
Supply, Laying and testing MS pipes heavy grades (ERW steel) including cutting,bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 25 mm as per IS 1239 (1981) fixed in replacement of existing u/s complete by cutting road and footpath and making surface good as previous all as specified and directed.
Descaling of condensor with the help of descaling chemical and nylon brush and cleaning the floor completely after condenser descaling complete up to the satisfaction of the Engr in charge of the following capacity of the AC plant's unit of any make. Note: If descaling needed in any already descaled plant again during the complete contract period, same shall be done free of cost. Rate for the same shall be included in quoted rate.
Up to 15 TR Capacity.
15 TR to 30 TR Capacity
30 TR to 50 TR Capacity
50 TR to 75 TR Capacity
Excavation in trenches loose/soft soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundations, laying water mains, pipes, cables, etc getting out and formaing bottom surface to required gradient complete all as specified.
Returing filling in incl spreading leveling, watering and well ramming in layer not exc 25 cm each layer complete all as specified.
Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified.
Material and labour for Gl sheet metal ducts made of Gl sheet of Class -VIII as per IS -277 of following thickness for supply air ducting as per IS - 655 and as required by the specifications for 24 gauge galvanised sheet steel complete.
Supply and fixing in replacement of old unserviceable earth continuity conductor of size 25X4 mm galvanised iron strip along with all necessary jointing material as directed by Engineer in charge.
Taking down unserviceable /burnt scroll compressor of capacity up to 10 TR and material & labour for scroll compressor of capacity up to 10 TR suitable for any water/ air cooled package/ central AC plant of make blue star/ Voltas etc including removing of refrigerent empty cylinder R-407/ R-22 flushing the system with nitrogen gas pressure testing and leak reparing vaccumising the system 700 micron charging the refrigerent R-407/ R-22 complete all as specified and directed by Engr in charge. Note : Make and model of compressor shall be exactly the same as per the existing compressor. Main installed makes are Copeland and Danfoss. Initial charge of refrigerent is included in this quoted rate.
All as per item no 78 but capacity above 10 TR to 15 TR
All as per item no 78 but capacity more than 15 TR
Taking down unserviceable liquid line filter drier of capacity up to 10 TR and material & labour for liquid line filter drier of capacity up to 10 TR suitable for any water/ air cooled package/ central AC plant of make blue star/ Voltas etc including removing of refrigerent empty cylinder R-407/ R-22 flushing the system with nitrogen gas pressure testing and leak reparing vaccumising the system 700 micron charging the refrigerent R-407/ R-22 complete all as specified and directed by Engr in charge Note : Make and model of compressor shall be exactly the same as per the existing compressor.
All as per item no 81 but capacity above 10 TR to 15 TR
All as per item no 81 but capacity more than 15 TR
Taking down old unserviceable Expansion valve of capacity up to 10 TR and supply, fixing and testing new Expansion valve of capacity up to 10 TR suitable for water/ air cooled centerlised/ Package type AC plant complete all as specified and as directed . Note : Make and model shall be exactly the same as per the existing installed.
All as above but capacity above 10 TR to 15 TR
All as above but capacity more than 15 TR
Supply and fixing of digital temp & humidity display system showing ambient temp, room temp and RH and necessary control wiring and sensor include Thermostat complete all as specified and directed by Engineer-in-charge.
SHARMA CONSTRUCATION COMPANY (BID ID -3131374)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .