| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC MES CHOWPATHY PO HASIMARA DISTT JALPAIGURI PIN 735215 WB | HASIMARA | JALPAIGURI | WB | 735215 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹47.0 L+₹3.3 L (7.46%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹48.0 L+₹4.3 L (9.81%)Rejected-Finance MES CHOWPATTI HASIMARA DIST JALPAIGURI WB PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹48.2 L+₹4.5 L (10.2%)Rejected-Finance HAMILTONGANJ NETAJI PALLY NEAR ICE FACTORY DISTT ALIPURDUAR WEST BENGAL 735 214 | ALIPURDUAR | WEST BENGAL | 735214 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹48.7 L+₹4.9 L (11.3%)Rejected-Finance INDEX NO D 35 ADG NEI GUWAHATI OLD HASIMARA POST HASIMARA DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) HASIMARA
GE (AF) HASIMARA PO-HASIMARA DIST- ALIPURDUAR PIN-735215
PROVN OF HARDSTANDING AND ALUMINIUM PARTITION WITH DOOR AT SRE BLDG, PROVN OF GREASE TRAP AND SOAK WELL ALLIED INFRA AND ADDN/ALTN TO LT INFRASTRUCTURE AT 10 AFH AREA AT AF STN HASIMAR
2024_MES_666499_1
C/8740/2024-25/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹80,000
Yes
10 Sept 2024
18 Jul 2024
7 Sept 2024
18 Jul 2024
5 Sept 2024
1 Aug 2024
Amount
Surface dressing not exceeding 15cm deep in soft/loose soil, complete all as specified and directed.
Excavation over areas n. exc. 1.5m deep and getting out in soft/loose soil, complete all as specified and directed.
Excavation over areas exc. 1.5m and but n. exc. 3.0m deep and getting out in soft/loose soil, complete all as specified and directed.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in deep for foundation or for shaft, wells, cesspits, manhole, etc. n. exc. 10 Sqm on plan and getting out in soft/loose, complete all as specified and directed.
M&L for hardcore of gauge not exceeding 63mm of broken stone, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for 100mm thick PCC (1:3:6) type C- 2, (using 40mm graded crushed stone aggregate) as in floors, pavings or plinth protection, hardstanding etc., complete all as specified and directed.
S & F powder coated (minimum thickness of powder coating 50 micron) aluminium anodised door comprising of frame of size 101.60mm x 44.6mm x 2.4mm thick push/pull type glazed door shutter having top and bottom section of size 83 x 44.5 x 2.4mm and 100 x 44.5 x 2.4mm thick respectively, styles section of size 80 x 44.5 x 2.4mm thick and lock rail of size 100mm x 44.5mm x 2.4mm thick including necessary jointing cleat, glazing clips, rubber packing, anodised aluminium snap beading, screws of suitable size including 5mm thick tinted sheet glass in both panel, hinges, mortice lock, stays & aluminium anodised handle of suitable size, etc, complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminium work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/appropriate 'Z' sections and other section of approved make conforming to IS-733 and IS-1285, fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions, i.e. at top bottom and sides with required EPDM rubber/neoprene gasket. aluminium sections shall be smooth rust free straight mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling, CP brass/stainless steel screws, complete all as specified and directed.
S&F 3mm thick ACP (aluminium composite panel) sheet, wooden finish, in aluminium frame including all nessesary fitting, complete all as specified and directed.
S&F 10mm thick toughned glass, as in partition, fixed to aluminium section, including cutting to shape, drilling holes, as required, complete all as specified and directed.
M&L for PCC (1:4:8) type D- 2 (using 40mm graded crushed stone aggregate) as in foundaion, filling and mass concrete, complete all as specified and directed.
M&L for brick work with fly ash bricks, old size, straight or curved on plan exc. 6m mean radius, built in CM (1:4) as in half brick thick wall, complete all as specified and directed.
M&L for brick work with fly ash bricks, old size, straight or curved on plan to any radius, built in CM (1:4) as in half brick thick wall, complete all as specified and directed.
M&L for PCC (1:2:4) type B- 1, (using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, clis, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, coping, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles, complete all as specified and directed.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, endings and similar work not exceeding 200mm thick (horizontal of sloping) for flat rough finished surfaces of concrete, complete all as specified and directed.
Use & waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, floor and roofs n. exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n. exc. 20cm wide, rough finished surfaces of concrete, complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces, finished even and smoth without using extra cement, complete all as specified and directed.
M&L for providing precast cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregrate) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortat (1:4), complete all as specified and directed.
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, rough finished surfaces of concrete, complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregrate) as in beams, cantilevers. bressummers, lintels etc., complete all as specified and directed.
S & F mild steel TMT bars 10mm dia (Grade Fe-500D), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia., or securing with clips, complete all as specified and directed.
All as per item No 21.00 here-in before but 6mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed.
M&L for loose filling with broken stone or boulders, aggregates of gauge 80 to 150mm in soakage pits, soakage wells, complete all as specified and directed.
M & L for PCC (1:3:6), type C 2 (using 40mm graded crushed stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 100mm bore pipe, complete all as specified and directed.
All as per item No 24.00 here-in before but 150mm bore pipe, complete all as specified and directed.
M&L for 100mm bore salt glazed stone ware (SGSW) drain pipes, grade 'A', complete all as specified and directed.
All as per item No 26.00 here-in before but 150mm bore pipe, complete all as specified and directed.
Removing excavated materials (soil) to a distance n. exc. 50m and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
Supply, laying, jointing and testing LT cable XLPE insulated, screened, PVC bedded galvanised steelstrip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, in trenches/fixed on walls of size 300 Sqmm, 3.5 core, confirming to IS 7098 (Part-II), complete all as specified and directed.
Supply, laying, jointing and testing LT cable XLPE insulated, screened, PVC bedded galvanised steelstrip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, in trenches/fixed on walls of size 185 Sqmm, 3.5 core, confirming to IS 7098 (Part-II) including taking down old unserviceable cable, complete all as specified and directed.
Supply, laying, jointing and testing LT cable XLPE insulated, screened, PVC bedded galvanised steelstrip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, in trenches/fixed on walls of size 95 Sqmm, 3.5 core, confirming to IS 7098 (Part-II), complete all as specified and directed.
Supply, laying, jointing and testing LT cable XLPE insulated, screened, PVC bedded galvanised steelstrip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, in trenches/fixed on walls of size 16 Sqmm, 4 core, confirming to IS 7098 (Part-II) including taking down old unserviceable cable, complete all as specified and directed.
Supply and erection of 8m height hot dip galvanised octagonal pole with double arm bracket made of HT steel of grade S355 of BSEN 10025, IS 2062 with 130 mm bottom & 70mm top made up of 3mm thick G.I. sheet along with base plate of size max up to 220 x 220 x 16mm thick with and including suitable foundation as per manufacturer recommendations, 4 Nos of M20 x 700mm long 'J' type EN 8 grade foundation bolts along with template, including integral power distribution arrangement with suitable breaker and connector for loopin loopout arrangement suitable for 4C x 16Sqmm/4C x 25Sqmm cable and including galvanised bracket of length 1.20 Mtrs double arm for fixing of LED street light including connection cable of 1.5 Sqmm 3 core from terminal box to fitting with MCB SP 6 Amp including dismantling of old unserviceable existing PCC pole of any size/shape and removing from site of work, complete all as specified and directed.
S&F in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down existing LED fittings from pole and deposited to MES store yard, complete all as specified and directed.
S & F in replacement cable 3 core PVC insulated, unsheathed, multistranded, copper (FRLS) conductor heavy duty, of sie 1.5 Sqmm in replacement passing through existing PVC conduit from junction box to fittings, complete all as specified and dirtected.
Supply, installation, commissioning and testing of out door type factory made LT feeder piller box (IP-54 protection) made out of 3.15mm thick CRCA sheet, (manufactured from CPRI type tested manufacturer) of suitable size, powder coated, totally enclosed, weather dust and vermin proof as per IS, front opening with locking arrangement having copper bus bar of 400 Amp capacity for RYB and neutral and insulated with insulators, including connecting incoming and outgoing cables, including necessary PCC (1:3:6) typr C-2 in foundation and made out of 50 X 50 X 6mm angle iron frame grouted ground by PCC foundation and 30cm above from ground level, complete all as specified and directed. Incomming:- (a) MCCB 200 Amp, 4 pole 36 KA with fixed thermal magnetic release - 02 Nos. (b) On load change over switch 200 Amp -01 No. Note: Cost of the item also includes necessary internal wiring for meters, CTs, indication lamps,etc and rigid copper bus bar connections from bus bar to MCCB terminals and suitable size copper wire connection from bus bar to MCB connections etc.
Supply, installation, commissioning and testing of out door type LT feeder piller box (IP-54 protection) made out of 3.15mm thick CRCA sheet,(manufactured from CPRI type tested manufacturer) of suitable size, powder coated, totally enclosed weather dust and vermin proof as per IS with front opening with locking arrangement having copper bus bar of 300 Amp capacity for RYB and neutral and insulated with insulators, including connecting incoming and outgoing cables, with necessary PCC (1:3:6) type C-2 in foundation and made out of 50 X 50 X 6mm angle iron frame grouted ground by PCC foundation and 30cm above from ground level including taking down old unserviceableLT feeder piller box of any size and removing from site of work, complete all as specified and directed. Incomming:- MCCB 160 Amp, 4 pole 36 KA with fixed thermal magnetic release - 01 No. Outgoing :- (i) MCCB 100 Amp, 4 pole 16 KA with fixed thermal magnetic release - 01 No. (ii) MCB 40 Amp, 'C' series 4 pole 10 KA - 04 Nos. (one spare part) Note: Cost of the items also includes necessary internal wiring for meters, CT's, indication lamps,etc and Rigid copper bus bar connections from bus bar to MCCB terminals and suitable size copper wire connection from bus bar to MCB connections etc.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of cover made by CI plate with angle iron frame /PCC cover with opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, lugs, complete in all respect,including galvanised iron strip of size 25 x 4mm as earth lead including 40mm bore (medium grade) galvanized iron pipe up to earthing test point for protection of earth lead connected to earhing test point, incl excavation and earth work and disposal of spoil to a distance not exc 50 mtr and necessary testing on completion,and writing the earth resistance value on PCC pit with black paint, complete all as specified and directed. Note: Proper earhing pit should be provided with pit cover.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 50mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 75/77mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 120mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
Horizontal boring under the road (with manual method) below 1m from the road surface and dia of hole not exc. 120mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work, complete all as specified and directed.
Supply and laying in trenches/fixed on wall, 100mm bore GI tubing, light grade, including necessary fittings such as bend, tee, elbow etc complete for protection of LT UG cable including taking up/down old unserviceable GI tubing, complete all as specified and directed.
Supply and laying in trenches/fixed on wall, 80mm bore GI tubing, light grade, including necessary fittings such as bend, tee, elbow etc complete for protection of LT UG cable including taking up/down old unserviceable GI tubing, complete all as specified and directed.
Supply and laying in trenches/fixed on wall, 50mm bore GI tubing, light grade, including necessary fittings such as bend, tee, elbow etc complete for protection of LT UG cable including taking up/down old unserviceable GI tubing, complete all as specified and directed.
Note: An amount of Rs.11,060.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S ROY ENTERPRISE (BID ID -3084979)
BHARAT ELECTRIC (BID ID -3086563)
MAJUMDER ENTERPRISE (BID ID -3087026)
M/S ANNI ENTERPRISE (BID ID -3086471)
M/S BISHAL ENTERPRISES (BID ID -3085125)
M/S SARDAR MAL NAHATA (BID ID -3084666)
M/S. VINITA CONSTRUCTION (BID ID -3077807)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .