Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC ATAL JI KI GALI SHINDE KI CHHAWANI LASHKAR GWALIOR MADHYA PRADESH 474009 | GWALIOR | MADHYA PRADESH | 474009 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹39.5 L+₹1.2 L (3.22%)Rejected-Finance 6 9 GRAND SQUARE DANAPUR CANTT PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹39.7 L+₹1.4 L (3.69%)Rejected-Finance 1ST FLOOR 100 FT ROAD NEAR HERO HONDA AGENCY OPP NARANG CHILDREN HOSPITAL BIBIWALA ROAD NORTH ESTATE | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹40.5 L+₹2.2 L (5.81%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹41.4 L+₹3.1 L (8.17%)Rejected-Finance 15 EMERSON ROAD DANAPUR CANTT PATNA 801101 | PATNA | PATNA | BIHAR | 801101 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹35.4 L
EMD Value
₹70,860
Closing Date
11 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE DANAPUR CANTT 801503
SPL REPAIR REPLACEMENT OF LT OVER HEAD LINE WITH UG CALBLE FPB AND ALLIED WORKS FROM QTR GUARD TO NALANDA BOYS HOSTEL AND MT PARK AT BRC UNDER GE DANAPUR CANTT
2024_MES_642901_1
CANOGE/DNR/T-71OF2023-24 8758/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DANAPUR CANTT
AS PER NIT
8 documents required · 8 mandatory
₹500
GE DANAPUR
₹70,860
Yes
12 Apr 2024
17 Feb 2024
14 Mar 2024
17 Feb 2024
11 Mar 2024
5 Mar 2024
Amount
Dismantling of OH ACSR conductor of any size and removing unserviceable conductor from site complete all as specified & as directed.
Dismantling of LT insulators any type or size complete all as specified & as directed.
Dismantling of cross arms of MS channels or angle, section etc complete and setting aside for reuse or as directed.
Dismantling of old unserviceable earth wire/cradles of any size or distributor span, complete all as specified & as directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles ,stay assembly and getting out in any type of soil complete all as specified and directed .
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
Material and labour for sand cushioning to under ground cables (8 cm deep before laying of cable and 15 cm deep over the cable ) & punning gently complete all as specified and directed .
Material and labour for Bricks , klin burnt , well burnt , whole , old size of compressive strength not less than 50 kg per sq cm laid in trenches as cable cover / protection complete all as specified and directed .
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed .
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 240 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Make: HAVELLS/ POLYCAB/GRANDLAY/FINOLEX) (NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule 'A' part).
All as per item No. 11 above but cross sectional area 185 Sqmm 3.5 core
All as per item No. 11 above but cross sectional area 150 Sqmm 3.5 core
All as per item No. 11 above but cross sectional area 95 Sqmm 3.5 core
All as per item No. 11 above but cross sectional area 50 Sqmm 3.5 core
All as per item No. 11 above but cross sectional area 35 Sqmm 3.5 core
All as per item No. 11 above but cross sectional area 25 Sqmm 4.0 core
All as per item No. 11 above but cross sectional area 16 Sqmm 4 core
All as per item No. 11 above but cross sectional area 10 Sqmm 4 core
All as per item No. 11 above but cross sectional area 10 Sqmm 2 core
M & L for Earthing to FPB/Junction box with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3of MES Schedule pt-I 2009, GI earth strip 32 x 6 mm protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified.
M & L in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall in repair complete.
Supply and fixing pole mounted SMC junction box/bus bar chamber for loop IN/OUT connection of street light cable of size 295x195x100 mm high heat distoration temperature, non-fusing , shockproff, rustproof, 100 % weatherproof, fire retardant- class FV-O as per IS 11731 Part-II and suitable locking arragement with three phase and neutral aluminium busbar of size 20X3 mm of length 170 mm wrapped with PVC sleeves with maintained the colour code and provision of making holes with GI nuts, bolts & washers for cable connections mounted on hydrograpic insulators with nuts & bolts at both ends of busbar complete all as specified and directed. Make: Sintex , Cat No: GSJB3020 or equivalent model of Hensel/Rittel.
Supply and fixing PVC Sheathed multi stranded unarmoured copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) of size 1.5 Sqmm 3 Core (Nominal Area) from pole junction box to light fitting with suitable size copper cable lugs and connector all complete as specified and directed. Make: Polycab/Havells/Plaza/Finolex.
M & L for Mild steel Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
Supply, fabrication, installation and testing of LT factory made (CPRI approved) water and vermin proof protection pedestal type feeder pillar box of minimum size 1200mm x 600mm x 500mm (overalls), outdoor type made out of 3.00 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable and air ventilation arrangement including provision of cable looping box of size 600 x 450 x 400mm made out of 3 mm thick CRCA sheet with front side openable double door shutter hinged door and locking arrangement at back side complete painted with Powder Coated paint of approved shade and suitable for 3 phase 4 wire system 500 voltage grade complete wiring and all incoming connections with copper strip busbar of required size to MCCB input including PCC (1:3:6) type C-2 as in foundation of size 0.80m x 0.60m x 0.90m depth (30 cm below ground level & 60 cm above ground level) including necessary excavation and earth work complete all as specified and as directed alongwith comprising of the following accessories :- NOTE: Rate of earthwork and PCC are deemed to be inclusive in this item.
Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved , junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. (a) Alluminium bus bar of size 50 mm X 6 mm X 400mm long wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. (b) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 150 to 185 sqmm 4 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 70 to 120 sqmm 4 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 25 to 50 sqmm sqmm 4 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 10 to 16 sqmm 4 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT XLPE cable outdoor end termination jointing kit suitable for 1100 volts grade 240 to 300 sqmm 4 core cable complete all as specified and as directed. Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT XLPE cable outdoor end termination jointing kit suitable for 1100 volts grade 150 to 185 sqmm 4 core cable complete all as specified and as directed. Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT XLPE cable outdoor end termination jointing kit suitable for 1100 volts grade 70 to 120 sqmm 4 core cable complete all as specified and as directed. Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT XLPE cable outdoor end termination jointing kit suitable for 1100 volts grade 25 to 50 sqmm 4 core cable complete all as specified and as directed. Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT XLPE cable outdoor end termination jointing kit suitable for 1100 volts grade 10 to 16 sqmm 4 core cable complete all as specified and as directed. Make : Raychem / 3M / Denson.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting 100 to 40 mm bore GI pipe all complete all as specified and as directed. ( Note :- GI pipe will be measured and paid separately).
Supply and fixing of GI tubing, light grade, 100 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete. Make - TATA / ZINDAL / Bansal .
-----do ------ all as per item No 38 above but GI tubing light grade of size 80 mm bore
-----do ------ all as per item No 38 above but GI tubing light grade of size 50 mm bore
-----do ------ all as per item No 38 above but GI tubing light grade of size 40 mm bore
Taking out of pressed precast concrete interlocking paver block any shape and size and refixing of same with 50mm thick sand cushioning filling under floors or in foundations including watering and consolidation complete all as specified and directed by EIC.
Supply, fixing and jointing of heat shrink LT cable end jointing kit suitable for 1100 volts grade 95 sqmm sqmm 3.5 core cable complete all as specified and as directed
M & L for Earthing to panels or junction boxes with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth GI strip of size 32 X 6 mm by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.03 of MES Schedule pt-I 2009, GI earth wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
M/s Naresh Chand Agrawal
M/S Priya Trading Agency
HARINANDAN RAI SONS
M/S SAROJ KUMAR SINGH
jaglalchoudharyandsons
VAISHNAVI CONSTRUCTION
SINHA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .