Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹32.7 L+₹1.7 L (5.55%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹38.4 L+₹7.5 L (24.2%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | Rejected-Technical C 125 A KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | - | Rejected-Technical Not Found in order |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Sept 2023, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIRS FOR ATTENDING DAY TO DAY E M EXTERNAL WATER SUPPLY COMPLAINT AT PARADE CAMP AREA, MALL ROAD POLO ROAD CHURCH ROAD STN ROAD URBAN VILLAGE MANEKSHAW MARG OLD NEW APS COLONY SANJAY VIHAR REPAIR REPLACEMENT OF WATER SUPLLY PIPE LINE AND CER
2023_MES_610362_1
GE/WS/IFA-03/Token-11 of 2023-24
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹80,000
Yes
28 Oct 2023
24 Jul 2023
15 Sept 2023
24 Jul 2023
13 Sept 2023
1 Sept 2023
Amount
Attending day to day external water supply complaints of all nature i.e. leakage in water supply pipe lines, fittings/fixtures, over flow of overhead tank, no water supply including noting the complaints in complaint register complete all as specified and as directed. (Note :- Material required for attending complaints shall be measured & paid separately under respectvie items here-in-after).
Attending external Electric supply complaints of day to day maintenance of existing LT panels including connecting electrical accessories/spares of water supply installations, electric fittings with lights, short circuits in pump house including noting the complaints in complaint register complete all as specified and as directed.. (Note :- Material required for attending complaints shall be measured & paid separately under respectvie items here-in-after).
Notes for Srl No. 1 & 2 :- The rates quoted by the contractor shall also deemed to be included for the following :- (i) The complaints shall be attended and the defects shall be rectified by a team of experienced one Electrician and two Plumber as applicable assisted with adequate number of helpers, matriculation passed qualified having minimum 03 years experience . (ii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 1000/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from his dues.
(iii) In case, after checking & attending the defect, if it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractor's view, no recovery will be made. (iv) While attending the complaint of water supply/Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A'/BOQ. However no extra payments shall be made for dewatering. (v) Cutting of GI pipe in position and threading is also deemed to be included in the job quoted rates (Fittings and fixtures shall be measured and paid separetely under respective items of Sch A/BOQ). (vi) All T&P required for attending the complaints shall be provided by the contractor without any extra.
(vii) The pipe fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench ,Chain wrench, Caulking tools, complete set of spanners and ladders etc..,as required at site. (viii) Old retrieved material shall be the departmental property and shall be deposited in the MES stroe yard on the same day. (ix) The electrician shall always be in possession of all electrician tools, LT megger, Earth tester, multimeter, crimping tool, insulation tape, hand gloves etc. as required at site. (x) BOO : All the materials as procured by contractor for fixing / fitting/ laying of materials as mentioned below shall be taken of charge with indicating purchase vouchers reference of materials and its quality and quantity shall got verified through BOO & to be issued through baby indent / USR's for material consumption at site as per requirement/complaint.
Supply only of the following items
PTMT stop cock 15 mm dia
PTMT stop cock 20 mm dia
PTMT stop cock 25 mm dia
Tank nipple 20 mm dia of required length
Tank nipple 25 mm dia of required length
Supply only GI Socket Med grade ISI Marked of following sizes ;-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only GI Elbow Med grade ISI Marked of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40mm bore
50mm bore
Supply only GI Union Med Grade, ISI marked of following Sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked suitable for following sizes:-
15 mm bore
20 mm bore
25 mm bore
40mm bore
50mm bore
Supply only GI Reducing socket medium grade ISI marked of the following sizes :-
25 mmx15mm bore
20mmx15mm bore
25 mm x 20 mm bore
25 mm x 32 mm bore
40 mm x 32 mm bore
50 mmx 40mm bore
40 mmx 20mm bore
40 mmx 25mm bore
50mmx 25mm bore
Supply only GI Tee Med grade ISI Marked of following sizes : -
15mm x15mm x15mm
20 mm x 20 mm x 15 mm
20 mm x 20 mm x 20 mm
25 mm x 25 mm x 25 mm
25 mm x 25 mm x 15 mm
25 mm x 25 mm x 20 mm
32 mm x 32 mm x 32 mm
40 mm x 40 mm x 40 mm
40 mm x 40 mm x 20 mm
40 mm x 40 mm x 25 mm
50 mm x 50 mm x 50 mm
50 mm x 50 mm x 40 mm
50 mm x 50 mm x 25 mm
50 mm x 50 mm x 20 mm
Supply only GI solid plug heavy duty ISI marked of following sizes
15mm bore
20 mm bore
25 mm bore
32 mm bore
40 mm bore
50 mm bore
Supply only Lead pig bar of best quality in sealed container complete all as specified and direcetd.
Supply only spun yarn of best quality in coils complete all as specified and directed.
Supply only Nuts, Bolts and Washers of 25 to 150 mm long of 6 to 20 mm dia complete all as specified and directed.
Supply only 3mm thick rubber gasket ISI marked complete all as specified and directed.
Supply & Fixing rotational moulded Poly-ethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 Ltrs tripple layered hoisted and fixed in position at pump house building top complete all as specified and directed.
Supply & Fixing rotational moulded Poly-ethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 Ltrs tripple layered hoisted and fixed in position at pump house building top complete all as specified and directed.
Supply only PTMT float valve with epoxy coated aluminium rod and high density plastic ball of following sizes complete all as specified and directed by engineeer-in-charge:-
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only gun metal gate valve with iron wheel head screwed both ends for iron pipe, ISI marked, as per IS : 778 of following sizes complete all as specified and directed by Engineer-in-charge
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Testing of drinking water collected from local source (bore wells /shallow wells) in the area of AGE(U) W/S No.II and submission of detailed test report to the office of Engineer-in-Charge for carring out following tasts:- (i) Carrying out minimum essential testing of water as per IS 10500-2012 mandatory for chemical colour, odour, taste, turbidity, PH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for drinking purposes. (ii) Collection of water from different sources of water i.e. Sump, bore wells & shallow well in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification
Note :- Rate Quoted shall also deemed to be included for the followings:- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells) (iii) Testing shall be carried out from Govt approved testing lab/NABL lab as approved by GE. (iv) Payment of job shall be made only after production of test reports of NABL lab.
Excvation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required complete all as specified and as directed by Engineer-in-charge.
Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed by the Engineer-in-charge.
Removing excavated material from site to a distance not exc 50 m away and depositing where directed not exc 1.5 meters above the starting point all as directed by Engineer-in-charge
Boring holes under road pavement by bocky manually/mechanically in any type of soil upto 200 mm bore complete all as specified and directed by Engineer-in-Charge.
Surface dressing of uneven surfaces of the natural ground, rough excavated surfaces and filled area where ordered shall be trimed to an even surface horizontal or slopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site depth of cutting not exceeding 15 cm complete all as specified and directed by Engineer-in-Charge.
Supply only 15 mm bore Bib tap standard of PTMT any colour high pressure screwed for male/ female treaded, for UPVC pipe/GI pipe of size 15mm bore complete all as specified and directed
Labour work required for taking out suction pipe 80 mm to 200 mm bore from sump of any capacity, dismantling of foot valve screwed / flanged type, and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket/ lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as required and as directed by Engineer-in-Charge.
Supply only 'stem' made out from SS (all as per sample) of sluice valve of size as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'stem nut' made out from stainless steel suitable to match with existing sluice valve of sizes as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'gland plate' made out CI, suitable to match with existing sluice valve of sizes as under
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Taking up or down steel tubing with connection including cleaning for removal all as specified and as directed by Engineer-in-Charge of the follwing sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Relaying/refixing only jointing and testing of old GI pipes including cleaning completely in trenches/walls/floors as directed for the following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Supply & fixing of GI pipe medium grade ISI marked including all fittings in old/new position as in walls/trenches and ceilling all as directed of following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm bore
S&F of DI fitting in replacement for flanged /spigot and socketed pipes such as bends, reducer, tee pieces, tail pieces, collar, cross, caps & plug upto 150mm bore complete all as specified and directed.
S&F of CI fittings/specials in replacement such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of upto 150 mm bore dia size confirming to IS: 1538-1993 complete all as specified and directed by Engr-in-Charge.
Taking up cement pipe/CI/DI pipe of water mains including all fitings with spigot and socket ends and lead joint including burning out joints and removing lead of following sizes complete all as specified and directed
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Relaying/refixing of cement pipe CI/DI pipes after cleaning from inside with suitable chemical and rodding complete all as directed by Engineer -in-charge of following sizes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supplying, laying, jointing, testing and commissioning of DI pipe as per IS 8239 class K-7 with in side cement mortar lining with spigot and socketed end laid in trenches complete with including rubber gasket joint all as specified and as directed at site for the following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F of CI sluice valves of following sizes class PN 1.0 ISI mark flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with including nut and bolts washers and rubber gasket, taking down old unsv sluice valve complete all as specified and as directed
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge.
M&L Brick work with sub class 'B' bricks old size straight or curved on plan exc. 6M mean radius built in CM (1:4) or as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing of debris from site complete all as specified and as directed at site by the Engr-in-Charge.
Supply and filling Multipurpose Grease lubricant for Motors & Pumps complete all as specified and
Supply, fixing, jointing & testing butterfly valve (wafer type) of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, inserting new one complete including taking down of old butterfly valve complete all as specified and as directed at site by the Engr-in-Charge.
100 mm bore
150 mm bore
200 mm bore
Supply, installation and testing flanged ends strainer/dirt box of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/ vertical position, including taking out unsv strainer/dirt box complete all as directed at site by the Engr-in-Charge. (Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.)
80 mm bore
100 mm bore
150 mm bore
Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv water meter complete all as specified and directed at site by the Engr-in-Charge. (Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item).
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply and fixing CI foot valve flanged ends, swing type opration with rubber sheet, as per IS:4038 including taking out unsv foot valve all as specified and directed by Engr-in-Charge. (Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item).
100 mm bore
150 mm bore
Supply, fixing, jointing and testing of Cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unsv NRVcomplete all as specified and as directed at site by the Engr-in-Charge. (Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item).
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') 8mm thick laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI pipe line including taking down old unserviceable MS Pipe complete all as specified and directed by Engr-in-Charge. (Note:- MS Flanges and Flange joints complete with jointing materials shall be measured and paid separately).
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
M&L 15mm thick rendering (cement plaster) on fair faces or other than fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and direceted.
Supply & fixing UPVC pipes in replacement of pressure rating of 10Kg/C per square centimeter fixed complete to walls , ceiling, floor or in trenches any types of pipe including fittings & jointing to the existing of following sizes
75/80 mm dia
100/110 mm dia
150/160 mm dia
Supply & fixing in replacement of Brass QCV(Quick coupling valve)/QRC(quick release valve) of size 1-1/4" complete all as specified and as directed
Supply & fixing Gear driven pop up sprinkler (full/part), 1'' inlet, capable dia 28 mtr to 50 mtr 2.8-6.9 bars with a discharge rate of 25.4 - 116 lpm complete all as specified and as directed
Note:- Sch of credit amount of Rs.219395/- shall be deducted from total quoted BOQ Amount when work acceptance letter issued.
Rahul Enterprises
Satish Kumar Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .