| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC | ₹18.4 L | L1 | Accepted-AOC accepted |
| 2 | L2₹18.8 LRejected-AOC NO 36 KALAIVANAR STREET BHARATHI NAGAR MINJUR 601 203 | MINJUR | THIRUVALLUR | TAMIL NADU | 601203 | ₹18.8 L | L2 | Rejected-AOC rejected |
| Sl No | Description | Qty | Unit | KAARTHIKEYAN ENTERPRISES L1 | RAMYA ELECTRICAL WORKS L2 |
|---|---|---|---|---|---|
| 1.00 | I.Replacement of 6 Nos defective 245KV SF6 Breaker pole assembly in 230KV feeders of NCTPS-I.
Removal of bus bar / moose conductor connection from SF6 Breaker pole assembly. | 12 | Opn | 5,604 ₹67,248 | 5,650 ₹67,800 |
| 2.00 | Restoration of bus bar/ moose conductor at SF6 Breaker pole assembly connections. | 12 | Opn | 6,067 ₹72,804 | 6,080 ₹72,960 |
| 3.00 | Dismantling of existing SF6 Breaker from the structure. (3 Nos=1 set) | 6 | Nos | 7,507 ₹45,042 | 7,600 ₹45,600 |
| 4.00 | Erection of new 230KV SF6 Breaker and its accessories on the structure (3Nos = 1 set) | 6 | Nos | 12,512 ₹75,072 | 12,800 ₹76,800 |
| 5.00 | Crane hire charges | 72 | Hrs | 800 ₹57,600 | 850 ₹61,200 |
| 6.00 | II.Replacement of 3 nos existing 245KV Capacitor Voltage Transformer (CVT) at 230 KV Indoor Switchyard in NCTPS-I.
Dismantling of existing 230KV CVT from the structure | 3 | Nos | 2,252 ₹6,756 | 2,400 ₹7,200 |
| 7.00 | Erection of new 230KV CVT in the structure | 3 | Nos | 4,504 ₹13,512 | 4,550 ₹13,650 |
| 8.00 | Welding charges for Existing earth connection released and alteration of New CVT earthing connection. | 3 | Nos | 3,696 ₹11,088 | 4,000 ₹12,000 |
| 9.00 | Releasing moose ACSR conductor between CVT to wave trap and kundah conductor between CVT to line conductor. | 3 | Nos | 1,384 ₹4,152 | 1,390 ₹4,170 |
| 10.00 | Providing moose ACSR conductor between CVT to wave trap and kundah conductor between CVT to line conductor and fixing of new healthy clamps. | 3 | Nos | 2,769 ₹8,307 | 2,800 ₹8,400 |
Tender Value
Refer Docs
EMD Value
₹17,300
Closing Date
16 May 2025, 2:00 pmClosed
SE/ES/NCTPS-I
Superintending Engineer Electrical System NCTPS I Chennai 120
NCTPS I ES Circle EM I Dn S Dn I Replacement of 6 Nos defective 245 KV SF6 Breaker pole assembly 3 Nos existing 245KV Capacitor Voltage Transformer (CVT) 3 Nos existing 245KV Current Transformer (CT) 3 Nos Isolators 24Nos existing LAS in 230 K
2025_EB_554001_1
CE/NCTPS-I/SE/ES/WC-75/2024-25
Open Tender
Power/Energy Projects/Products
360 days
NCTPS-I
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹17,300
Yes
20 May 2026
3 May 2025
17 May 2025
3 May 2025
16 May 2025
3 May 2025
Amount
I.Replacement of 6 Nos defective 245KV SF6 Breaker pole assembly in 230KV feeders of NCTPS-I. Removal of bus bar / moose conductor connection from SF6 Breaker pole assembly.
Restoration of bus bar/ moose conductor at SF6 Breaker pole assembly connections.
Dismantling of existing SF6 Breaker from the structure. (3 Nos=1 set)
Erection of new 230KV SF6 Breaker and its accessories on the structure (3Nos = 1 set)
Crane hire charges
II.Replacement of 3 nos existing 245KV Capacitor Voltage Transformer (CVT) at 230 KV Indoor Switchyard in NCTPS-I. Dismantling of existing 230KV CVT from the structure
Erection of new 230KV CVT in the structure
Welding charges for Existing earth connection released and alteration of New CVT earthing connection.
Releasing moose ACSR conductor between CVT to wave trap and kundah conductor between CVT to line conductor.
Providing moose ACSR conductor between CVT to wave trap and kundah conductor between CVT to line conductor and fixing of new healthy clamps.
Welding charges for alternation of CVTs Existing bed frames
Crane hire charges
III .Replacement of 3 Nos existing 245KV Current Transformer (CT) at 230KV Indoor Switchyard in NCTPS-I. Transporting of new 245KV current transformer and its accessories from Central stores to 230KV outdoor Switchyard. (3 Nos=1set)
Removal of moose conductor connection from Tower end
Dismantling of existing 245KV Current transformer from the structure. (3 Nos=1 set)
Erection of new 245KV Current transformer and its accessories on the structure (3 Nos=1set)
Restoration of moose conductor at tower connections no 1 end jumper.
Welding charges for alteration of Current transformers earthing connection (3 Nos = 1set)
Reconnecting the dropper jumper between main buses after replacing the existing old conductor by new jumper, which involves taking measurement, cutting new conductor for required length, cleaning the new jumper, PG clamp & connecting PG clamp to new jumper and tightness checking in Indoor switchyard. (Replacement of pedestal CT)
Crane Hire charges
IV. Replacement of 3 Nos Isolators at NCTPS-I. Releasing the isolator blade, top support insulator in switchyard
Replacement of damaged PT insulators in ‘B’ isolator of Y phase of Bus section CT (Replacement of damaged PT insulators)
Replacement of 24 nos existing LAS due to ageing and obsolescence in 8 Nos feeders of 230 KV switchyard at NCTPS-I. Assembling of new LAS stack one by one and reconnect the jumper connection and assisting with MRT testing.
Removal Reconnecting of moose connection from Tower end
Crane Hire charges
Cleaning and tightness checking in Power Transformers, Fixed and moving contacts in 230KV switchyard, main bus/ Transfer bus, LAS, Neutral grounding transformers in NCTPS-I. Routine cleaning, tightness, checking and assisting in MRT testing works and attending glow, changing the defective clamps if any, finger contacts and moving contacts, etc, in 230KV SF6 breakers, Isolators, LAS, CVT, CCm wave trappers for quarterly maintenance.
Cleaning, tightness, checking and assisting in MRT testing works in 230KV main bus / Transfer bus, bus section SF6 breakers and isolators.
Cleaning and tightness checking of 3 nos HV bushings and 6 Nos LV Bushings (52/25MVA station transformer)
Cleaning of Earth resistors and neutral grounding transformers, assisting in measuring the value of resistors and meggering of neutral grounding transformer testing of tan-delta value of transformer bushing and HV testing of LAS (50/16MVA Power Transformer)
Cleaning and tightness checking of 3 nos lightening arrestors and 3 nos pedestal support insulators and its jumpers connection clamps tightness checking work station transformer (250/50 MVA station Transformer)
T&P Consumables
RAMYA ELECTRICAL WORKS (BID ID -1333646)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
BOQ_661497.xls
BOQ • 0.30 MB