Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC 18 MOTI BAGH BABYAL ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹35.1 L+₹7.7 L (28.2%)Rejected-Finance OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹35.2 L+₹7.8 L (28.5%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Enlisted in appropriate category | |
| 5 | Rejected-Technical 2 2407 GILL COLONY NARAINPURI SAHARANPUR UP | SAHARANPUR | SAHARANPUR | UTTAR PRADESH | 247001 | - | Rejected-Technical Firm has not submitted tender fee short fall documents in spite of 07 days time |
Tender Value
₹32.2 L
EMD Value
₹64,400
Closing Date
7 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
PROVN OF CERTAIN B/R AND E/M WORK SERVICES IN OTM BLDGS AT AF STN SARSAWA UNDER GE (AF) SARSAWA
2023_MES_621288_1
8123/SAR-57/2023-24
Open Tender
Civil Works
Item Rate
333 days
GE (AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(AF) SARSAWA
₹64,400
Yes
25 Jan 2024
30 Sept 2023
14 Nov 2023
30 Sept 2023
7 Nov 2023
14 Oct 2023
30 Sept 2023 - 24 Oct 2023
Amount
Surface dressing n exc 15 cm deep soft/loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil
Excavating over areas, n exc 1.5m deep and getting out hard/dense soil.
M&L PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation complete all as specified & directed by Engr-in-Charge.
M&L for Plain Cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified& directed by Engr-in-Charge.
Earth filling under floors including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. Note :- Soil obtained from excavation under respective items here-in-before shall be used for filling.
M&L for Reinforced cement concrete (design mix -M-25 ) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L for 400 micron thick HDPE sheet water proof ,wrinkle free without puncture having minimum weight 390gm/Sqm over tack coat as specified and complete all as specified and directed Note : The rate of tack coat below sheet shall be deemed included in the quated rate
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
M&L for form work to sides of Pillars, posts, struts piers, columns etc in squarre, rectangular or polygonal, rough finished surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete (design mix -M-25 ) in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for formwork to chajjas, chullah hoods, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete (design mix -M-25 ) in Chajjas complete all as specified and directed by Engr-in-Charge. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete (design mix -M-25 ) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in Slabs supported on walls, beams and columns in floors, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate), as in sub base all as directed by Engineer-in-charge.
M&L for coloured non skid ceramic tiles (1st quality), 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles (1st quality), 300mm x 600mm x 7/8mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls and finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brick work of walls including finishing the surface fair and even complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately.
Supply only integral liquid water proofing compound (ISI marked). Make : Pidilite (Dr. Fixit Pidiproof LW) or equivalent of Fosroc / Sika / STP
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces of ceiling including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for preparation of new plastered surfaces of walls and applying two coats of Oil bound distemper over a coat of 1mm thick wall care putty of approved tint complete all as specified & directed by Engr-in-Charge.
Material and labour for preparation of new plastered surfaces and applying two coat exterior emulsion paint over a coat of primer paint complete all as specified and as directed any tint. Note: The Camouflaging Pattern/Plain pattern decided by Engr-in-Charge
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified & directed by Engr-in-Charge.
Material and labour for preparation of new plastered surfaces of ceiling and applying three coats white wash complete all as specified and as directed any tint.
M&L for Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Green marble over & including 20 mm thick screed bed in cement & sand mortar 1:6 complete
M&L for Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Green marble over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete
M&L for 15mm thick plaster over top of roof slab/chajjas in CM 1:4 mixed with water proofing admixture (ISI marked) as per manufacturer’s instructions, finished even and smooth without using extra cement all as directed. Note : - Supply only water proofing admixture shall be measured and paid for separately.
M&L for Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and directed.
M&L APP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.
S&F anodized aluminium frame with power coating (minimum thickness 50 micron) and other sections for doors, windows, ventilators, partitions, with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed.
S&F anodized aluminium grill with power coating (minimum thickness 50 micron) of approved pattern and fixed to the existing window/ventilator frame with CP brass/stainless steel scrwed @ 200mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement & directed by Engr-in-Charge.
S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m,with power coating (minimum thickness 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed.
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam sheet instead of wood grain printed PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded prelam PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of prelam both side PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, stile & rails feathered at edges, suppling & fixing in the frame at site as per specification & drawing.
Supply and fixing stainless steel hinges 100mm long medium weight to pressed steel/angle iron frames by welding/screws all as specified.
S&F aluminium anodised barrel tower bolt 200mm size extruded section, ISI marked & fixed complete all as specified and directed.
S&F extruded aluminium alloy handles 150mm size fabricated type anodised. ISI marked. complete all as specified and directed.
S&F 300 mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, ISI marked complete all as specified.
Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I
S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and as directed.
S&F galvanised steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
S&F galvanised steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
S&F 15 mm bore bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F of size of gully trap 150mmx100mm Salt-glazed stoneware gully traps, square or round mouthed, tvpe 'P' complete all as specified.
S&F PVC connection 600 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&F 15mm bore stop / angle valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified.
S&F 110 mm bore PVC (SWR) single junction (single 'T' ) equal or unequal with access door complete all as specified.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110mm bore PVC (SWR) vent cowl complete all as specified.
S&F Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) grating including jointing with solvent cement, diameter of outlet 100mm, complete.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and including connections to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete
S&F PVC valveless, syphonic action type, flushing cistern, low level, white (ISI marked) of 10 litre capacity with inlet, ball valve, float and handle including brackets, flush pipe of polyethylene of low or high density or 32 mm dia PVC pipe, for low level cistern connections to pipes and fixing of chain and pull, or lever, if any complete all as specified..
S&F chromium plated Brass health faucet for EWC with including PVC Connection 1m long suitable for 15mm bore with all connected fittings.as approved by the GE.
S&F fancy type 15mm bore Pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore all as specified
S&F vitreous china counter top/down basin size 450 x 525 x 195 mm shape oval of Jaquar or equivalent of PARRYWARE / MARC / KINGSTON / SOMANY / ESS ESS / SIECO / KOHLER / HINDWARE / PRAYAG / PARKO including 32 mm CP waste coupling complete all as specified & directed.
S&F tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges fixed to wall complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above or below the starting point complete all as specified & directed by Engr-in-Charge.
Removal of excavated material (soil) to a distance exc 250m but not exc 500m and depositing where directed complete all as specified & directed by Engr-in-Charge.
M&L for PCC (1:2:4) type B2 (using 20mm graded stone aggregate), as in water tank /feeding/platform including necessary formwork all as directed by Engineer-in-charge.
Providing and laying for Precast steel fibre Reinforced concrete RCC Soak Well Ring and size of ring 1200mm dia , 600mm height , ring wall 75mm thick complying to the standard specifications as mentioned in the IS 12592 BIS Standard circular shape complete all as specified and directed by Engr-in-Charge.
Providing and laying 100mm thick for precast SFRC drain cover without frame but including complete sides iron sheets (medium ) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 5 ton /Sqm in square or rectangular shape complete all as specified and directed by Engr-in-Charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified.
S&F stainless steel gratings 100 mm dia with waste hole for floor trap/Nahani trap complete all as specifed and as directed
S&F urinal size of 14" x 16" x 25 " white(minimum),including CP urinal spreader with CP push cock complete all as specified.
S&F 32mm dia Brass chromium plated bottle traps for wash basins/urinals with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed Complete all as specified
M&L for 75mm thick PCC Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in flooring & alternate panel (2mtr X 2mtr ) with filling bitumen etc. including necessary form work complete all as specified and directed by Engr-in -Charge. Note :- Bitumen gola, with 80/25 bitumen and coarse sand mortar 1:3 shall be measured and paid separately under respective items.
M&L Cement concrete for 100mm thick 1:2:4 type B1 (20mm graded stone aggregate) as in flooring & alternate panel (2mtr X 2mtr ) with filling bitumen etc. including necessary form work complete all as specified and directed by Engr-in -Charge. Note :- Bitumen gola, with 80/25 bitumen and coarse sand mortar 1:3 shall be measured and paid separately under respective items.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified & directed by Engr-in-Charge.
M&L for 20mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long complete all as specified and directed
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 Gde E-165 etc complete all as specified & directed by Engr-in-Charge.
M&L steel work in tubular truess, purline rafter columns etc including welding ,butt welded tubes conferming to IS-1161-1979 grade St-240, complete all as directed by Engineer-in-charge.
S&F mild steel work such as angle iron in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc) including necessary welding where required as per site requirement and other similar works complete, conforming to Gde E-165 (Fe 290).
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed by Engineer-in-charge and all as specified.
Preparation of new steel surfaces of any description over 10 cm width or girth and applying one coat of red oxide primer complete all as directed by Engineer-in-charge and all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverin/cladding t wall fixed with self tapping screwas as specified fixed etc complete all as specified & directed by Engr-in-Charge.
S&F Framed work such as grills, gratings , angle etc, with ends of bars shoulders and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework and plain black MS sheet for tanks, iron pipe for oil of any bore, MS gate valves of any size fixed to iron oil pipe etc, cut to size edges beaded if directed, holes punched screws, clout nails or rivets and fixed to wood or steel members including bending, turning up, mitred angles, stopped ends, outlets etc complete as directed by Engr-in-Charge.
M&L for providing cement concrete 1:2:4 type B1(using 20mm graded stone aggregate ) as in coping all as specified and directed including necessary form work.
M&L for Concrete bed 1:4:8 type D2 (using 40mm graded stone aggregate) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested
M&L for Reinforced concrete pipes 450mm bore class NP2 , laid and jointed complete with collars complete
Excavation in post holes each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplush soil to a distance n exc 50m and making good surface complete all as directed by Engineer-in-charge and all as specified.
Supply only Chain link MS galvanisd fencing, any size or type complete
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.incl provission of binding wire.
S&F mild steel round bars as in tie bars of 10 mm dia and over, fixed to fencing posts including cut to length, bent to shape, welding of bar at spots as directed and other similar works, conforming to Grade E-165 (Fe 290), complete, all as specified & directed. Note: Cost of cutting to length, bent to shape rquired & binding with MS wire is included in above
S&F for Mild steel screw bolts dia of Neck 5mm to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 5cm but n exc 10cm long compleete all as directed by Engr-in-charge.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
S&F Rolled mild steel Framed work as in doors or gates of angle or other section confirming to Fe-290 with gusset plate , rails braces etc. complete drilled for fixing of steel sheeting or other covering door etc to be prepared for hanging or slinding with and including either hooks hinges and rollers for slinding gates, guide rail of MS flat and framing required for fixing of rollers, pintle hinges, locking arrangement as required and hanging also fastening and fixing complete using Fe- 290 (Gde E-165) quality 'A' compleete all as directed by Engr-in-charge.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed CM 1:6 complete all as specified & directed by Engr-in-Charge.
M & L for concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes modular type including cover plate with frame of modular type of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :- One light / fan point controlled by one way switch
One 5 Amp socket outlet on same board.
All as per above item No-105 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed.
S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.
S&F in replacement switch 6 amps modular type one one way complete all as directed.
S&F in replacement switch 16 amps modular type one one way complete all as directed.
S&F of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S&F of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V including connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.
S&F MCB SP 5 to 40 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F MCB DP 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
Supply and fixing of PVC round shape junction box cover of suitable size including fcomplete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, 1400 RPM, blades, and frame and louver with double bearing complete with making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and as directed by Engr-in-Charge.
S&F enviroment friendly indoor decorative 10 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
Supply and fixing DOL starter single phase 240 Volt suitable for 1 HP pump complete all as specified and directed.
Supply and fixing single phase 240 volt monoblock pump with motor of capacity 1 Hp complete all as specified and directed by engr-in-charge. Note - Earthwork, PCC for platform of suitable size for mounting Pump shall be include.
Supply & fixing of Nylon hose pipe 25 mm bore, heavy duty complete with clamping of required size, nuts bolts and washers etc complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 25 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply, installation & testing of Waterless and maintenance free Earthing (grounding) electrode of size Dia 85 mm x Length 3000 mm with 17.2 mm Cu bonded MS conductor in Pre cast in high purity electrically conductive granular (Marconite), having ultra low resistivity of 0.001 Ohm - m. (Provide the resistivity certificate for the same) Electrode made of electrically conductive granular mixed with cement to pre cast or backfill the voids surrounding the metal conductor in augured bore hole of 100 mm dia x 3000 mm depth, resulting in increase of effective surface area of the earth electrode. Electrode's top terminal should be sealed permanently with the conductive concrete and extension strip taken out be terminated at earth bus bar. Other hardware like nuts, bolts and washers should be of Stainless Steel. Electrode should withstand fault current up to 30 kA for 1 second.(Bidder Provide the certificate for the same ) Note :- (i) Supplier of the Marconite Earthing Material should provide authorization letter from the Manufacturer for the Genuine material and also furish certifications as per IEC 62516-7 & resistivity certificate confirming 0.001 ohm-m. (ii) In case of use of multiple electrodes interconnection between earth electrodes to be provided with Copper Bonded MS strip of size 25mm x 6mm embedded in marconite concrete 70 Sqmm and connection from electrode/grid to equipment to be provided by copper cable 10 Sqmm single core cost of which is deemed to be included in quoted rates.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide & not exc 1.5 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge.
Returning, filling in including spresding leveling watering and well ramming in layers not exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge..
Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
Supply and fixing of GI tubing, light grade, 20 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
SUBHASH CHAND CONTRACTOR
RAJAN TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .