Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance R O SKERBUCHAN TEH KHALTSI LEH LADAKH 194106 | LEH LADAKH | LADAKH | 194106 | Admitted-Finance |
| 3 | Admitted-Finance R O NIMOO | LEH LADAKH | LADAKH | 194101 | Admitted-Finance |
Tender Value
₹2,500
EMD Value
₹1.4 L
Closing Date
13 May 2025, 2:00 pmClosed
Executive Engineer EDD Leh
PDD Choglamsar
same as above
2025_PDNRE_16197_1
e-NIT No. 14 of ED Leh of 2025-26 dated 03-05-2025
Open Tender
Electrical Works
Turn-key
60 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
Payable To Executive Engineer EDD Leh
₹1.4 L
23 May 2025
3 May 2025
14 May 2025
3 May 2025
13 May 2025
5 May 2025
Amount
Supply part
Earth work excavation by manual means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottom lift upto 1.5m, including getting out evcavated earth and disposal of surpulus excavated earth as directed by Engineer-in-charge
Filling available execavated earth(excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Disposal of excavated earth (Carriage of materials) beyong 3KM
Supply of 1 core x 400sqmm XLPE Al Armoured cable (main conductor) 11KV including one spare
Supply of 160mm HDPE Pipe along with clamps for cable termination on tubular pole
Supply of Jointing Kit
Supply of RCC Route indicator (base dimansion 250mmx1599mm, Top dimnsion 700mmx75mm, Heaight 1250mm) cement concreate 1:2:4, Rainforcement detail: 6mm iron round ring=5Nos, 6mm vertical bar=12Nos. 12 guage GI wire mesh and with written indication of 11KV HT Line
Laying of 1core x 400sqmm XLPE AL armoured cable (main conductor) 11KV including one spare
Laying of 160mm HDPE pipe along with clamps for cable termination on tubular pole and road crossing
Termination of 400sqmm HT 11KV Single core cable including one spare
Fixing of RCC Route indiactor (base dimention 250mmx1500mm, Top dimnsion 200mmx75mm, Heaight 1250mm) cement concreate 1:2:4, Rainforcement detail: 6mm iron round ring=5Nos, 6mm vertical bar=12Nos. 12 guage GI wire mesh.
Installation/Commissioning/Testing ( Labour part)
Earth work excavation by manual means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottom lift upto 1.5m, including getting out evcavated earth and disposal of surpulus excavated earth as directed by Engineer-in-charge
Filling available execavated earth(excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Disposal of excavated earth (Carriage of materials) beyong 3KM
Supply of 1 core x 400sqmm XLPE Al Armoured cable (main conductor) 11KV including one spare
Supply of 160mm HDPE Pipe along with clamps for cable termination on tubular pole
Supply of Jointing Kit
Supply of RCC Route indicator (base dimansion 250mmx1599mm, Top dimnsion 700mmx75mm, Heaight 1250mm) cement concreate 1:2:4, Rainforcement detail: 6mm iron round ring=5Nos, 6mm vertical bar=12Nos. 12 guage GI wire mesh and with written indication of 11KV HT Line
Laying of 1core x 400sqmm XLPE AL armoured cable (main conductor) 11KV including one spare
Laying of 160mm HDPE pipe along with clamps for cable termination on tubular pole and road crossing
Termination of 400sqmm HT 11KV Single core cable including one spare
Fixing of RCC Route indiactor (base dimention 250mmx1500mm, Top dimnsion 200mmx75mm, Heaight 1250mm) cement concreate 1:2:4, Rainforcement detail: 6mm iron round ring=5Nos, 6mm vertical bar=12Nos. 12 guage GI wire mesh.
Supply part
200 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 25kVA, Copper wound for 25kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
LT Distribution Box for 200 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp and suitable MCCBs for outgoing circuits with terminal extensions
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3-pahse, 4-wire Trivector Smart Meter with CT (LTCT AMR compatible)
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, jumper, binding Tape
Transformer Fencing
40mm aggregate/Gravels inside fencing
Installation/Commissioning/Testing ( Labour part)
200 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 25kVA, Copper wound for 25kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
120mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
LT Distribution Box for 200 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp and suitable MCCBs for outgoing circuits with terminal extensions
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3-pahse, 4-wire Trivector Smart Meter with CT (LTCT AMR compatible)
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, jumper, binding Tape
Transformer Fencing
40mm aggregate/Gravels inside fencing
HT Line (Supply Part )
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply of GI Channel X-arm including clamps and braces for DP (80Kg/DP)
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
Running earthing on HT Line
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
Installation/Commissioning/Testing ( Labour part)
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply of GI Channel X-arm including clamps and braces for DP (80Kg/DP)
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
Running earthing on HT Line
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
M/S SONAM ANGCHOK (BID ID -156993)
M/S CHHIRPON BUILDERS (BID ID -156979)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .