| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹9.0 L+₹1.0 L (12.7%)Rejected-Finance 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹9.4 L+₹1.4 L (17.5%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹9.6 L+₹1.6 L (20.1%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹9.7 L+₹1.7 L (21.3%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹8.9 L
EMD Value
₹17,740
Closing Date
26 Jan 2024, 5:00 pmClosed
Shri Shubham yadav,AEE
AGE I Chimney Hills, Chikkabanavara post, Bangalore
REPAIR MAINT OF STREET LIGHT, SOLAR STREET LIGHT, SOLAR WATER HEATER CERTAIN MISC WORKS AT NO 2 AFSB MYSORE UNDER AGE I AF CHIMNEY HILLS.
2023_MES_634267_1
8668/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AGE I AF CHIMNEY HILLS BANGALORE
As per tender document
8 documents required · 8 mandatory
₹500
Yes
AGE I AF CHIMNEY HILLS BANGALORE
₹17,740
Yes
1 Apr 2024
8 Jan 2024
27 Jan 2024
8 Jan 2024
26 Jan 2024
19 Jan 2024
8 Jan 2024 - 15 Jan 2024
Amount
M & L for servicing of Solar street light fitting of 2x11/1x11 watt capacity including servicing of module cleaning, battery inspection, checking of distilled water in battery , inspection of electronic circuits etc.
Supply & Fix in repair battery box for battery housing suitable for solar light fittings
Supply & Fix in repair battery 110 AH 12 Volts suitable for solar lights
Supply and pore battery electrolyte (distilled water with acid) once in every quarter for each battery
Supply & Fix in repair luminaire assembley for 1x11 watt LED lamps (new solar light fittings) with complete accessories all as specified and as directed.
M & L for repairs to solar water heater system by checking the leakage / sepage of the system if found rectified through the authorised dealers. Draining out the system by opening the cold water out let and hose to the bottom tank,dry out the system refilling the same after rectifing the leakes ,topping up with anti freeze solution of soft water,check the corrosion sacrificial anode,replace if found defective,clean the collector of capacity 100 LPD complete all as specified and as directed.
All as per Item ser No 6 here in before but capacity of 200 LPD
All as per Item ser No 6 here in before but capacity of 500 LPD
Supply and laying in repair CPVC pipes 20mm, SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S&F in repairs CPVC Ball valve suitable for 20mm dia pipe complete all as specified and directed
S & F framed work such as grills, gratings, etc., with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks .
S & F in repair thoughened Glass 6mm for Solar Water Heater Flat Plate collector, fix and seal as recommended by the manufacturer and all as directed
Taking down the defective / unserviceable street light/perimeter light/Garden light/Bollards/Flood lights fittings of any wattage, from the buildings/poles/post tops for repair and refixing the same after carrying out repair (replacement of spares like LED driver, surge arrestor, etc shall be measured and paid seperately) including attending complaints received through online for non-ops lights
S & F in replacement die cast aluminium IP66 LED Flood Light luminaire, 150 Watt capacity all as specified and directed Make : Cat part No: JETAIRISFLS150WLED757PSYMLTG of Havells or eqvt in CG / Philips
Supply and fix in replacement LED street light 60 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 Make:- Havells Cat Part No ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent in Crompton/ Phillips
All as per Item Ser No 3 here in before but capacity of 25 watts
S& F in replacement Bollards fittings 8 watt, IP 65, diffuser at the upper portion acts as a beacon of path guidance and necessary PCC foundation (of size 20x20x20 CM type C1 using 12.5 mm graded stone aggregate) for fixing including necessary cable connections all as directed. Make : Havells cat part No CONEBLS8WLED830PSYMTOPC(0.6M) or equivalent in Phillips/Bajaj as approved by Engr-in-Charge
S&F in replacement LED Post top lantern 15 watt, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed. Make : Havells cat part No CORALMINIPT15WLED757PSYMYOPC or equivalent in Phillips/Bajaj as approved by Engr-in-Charge
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core including dismantling of old U/S cable
All as per item no. 7 above but 16 Sqmm 2 core
All as per item no. 7 above but 16 Sqmm 4 core
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/repair of cable.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and lay brunt bricks class 'B' of standard size in trenches for protection of UG cable.
Supply and spread dry clean fine stone dust in trenches as cable cushioning to UG cable all as per clause 19.75 of SSR part -I
M & L for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in pedestal / coping of pole and in Road cuttings including form work If necessary .
Supply and fix in repair GI tubing 40 mm bore, light grade fixed to wall/floor and laid in trench complete for cable protection including fixing arrangements.
S & F for Hard PVC junction box of size 200x150x150 mm weather proof with three phase and neutral link connector and necessary cable gland- 2 Nos for LT UG cable 10/16 sqmm 2/4 core and locking arrangement and fixing with existing PCC / steel tubular electric pole above the copping with suitable MS clamps, nuts & bolts and necessary electric connection etc.complete all as specified and directed
M & L in replacement sub main wiring with two single core 1.5 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 1.5 sqmm multi stranded copper conductor FRLS cable as earth continuity conductor drawn into and including non-metalic rigid PVC conduit 20mm dia including accessories fixed on poles with proper bracings complete all as specified and directed. Note:- Two runs of 1.5 sqmm, one run of 1.5 sqmm conductors and one run of PVC conduit shall be measured as one unit
S & F GI pipe bracket 40 mm medium grade dia not exceeding 1.2 mtrs long bend to shape suitable for fixing street light to PCC/steel pole including suitable size MS clamps, bolts, nuts, washers, etc
Supply & Fix in repair LED driver suitable for 60 watt street light fitting, 240 Volts, 50 Hz complete all as specified and directed
SREE VINAYAKA ENTERPRISES
eurekaenterprises
KUZHIKKAL ENTERPRISES
JM Engineering
s v m construction building & engineers
AMK ENTERPRISES
SRI AYYAPPA ENTERPRISES
SAPTHAGIRI CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .