Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC 1 C NEPAL BHATTACHARJEE STREET KALIGHAT KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.1 L+₹58,977.20 (1.76%)Rejected-Finance 17 23 K P ROY LANE KOLKATA 700 031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | L2 | Rejected-Finance L2 | |
| 3 | L3₹34.5 L+₹1.0 L (3.06%)Rejected-Finance 13 11 MOTILAL GUPTA ROAD KOLKATA 700 008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹67,000
Closing Date
2 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
Temporary Electrical installation work in respect of Durga Puja Idol Immersion Ceremony 2025 at Red Road Part B Performance Lighting System work for both side of the Red Road.
2025_WBPWD_890620_1
WBPWD/EE-KED/eNIQ-26Q/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
11 days
Maidan
Please refer Tender documents.
5 documents required · 5 mandatory
₹67,000
O/O The Executive Engineer Kolkata Electrical Divi
25 Sept 2025
13 Aug 2025
4 Sept 2025
13 Aug 2025
2 Sept 2025
22 Aug 2025
21 Aug 2025
Amount
Supply and fixing of the following items on hire basis for 04 Days with carrying cost at the sites
200W,LED Flood Light(Warm White/ Cool White) fittings
200W,LED PAR(RGB) Light fittings
Sharphy Light fittings
400W, LED Blender (warm white)-4 eyes Light fittings
500W, LED Flood Light fittings
400W,LED high bay fittings
Providing on hire basis outdoor type LT panel having Incoming 415V, 200 A TNP main switch- 02 Nos, 415V, 200A Onload change over switch- 01 No, 415V, 500A 4 Bar Bus bar chamber-01 No, outgoing 415V,63A FPMCB-02 Nos,415V,32A FPMCB-08 No, 230V 6-32A SPMCB-06 Nos,03 Nos indicator with 6A SP MCB-03 Nos fixed on angle iron frame including necessary interconnection wiring with appropriate size Cu FRLSH wire with socketing , earthing attachment etc and dismantaling the same at the end of function.(For 4days)
Providing on hire basis main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following size including laying in trench (at least 230 mm below ground) including socketing and necessary finishing as required and dismantling the same and mending good the damages.(For 4days)
4C X 16 Sqmm AL cable
4C X 95 Sqmm AL cable
4C X 120 Sqmm AL cable
Supplying & Drawing on Hire Basis following size single core PVC insulated, unsheathed, multistrand 1.1Kv grade, copper/Al wire including necessary termination by socketing the wire ends & dismantling the same after completion of the program.(with PWD / E.I.C. approved materials) (For 4days)
7/0.064(7/16) Single Core
7/0.036(7/20) single core
Hiring charges for Operating Console as reqired for the lights on both side of the Red Road. (For 4days)
Hiring Charges for Cinematographer/Light designer for measureing light level required for videography and providing certificate in company's letter head before the programme. (For 4days)
Supplying & Providing on hire basis 415V, 3 Phase CPCB approved soundless diesel generator set for prime/standby operation with mobil incl. transportation ,one operator & appropriate size of cable upto 120 Mtrs including necessary interconnection, socketing & dismantling as directed by EIC after the program. If the DGs are not placed at site on time , pro rata rate will be reduced from bill.(For Programme & Rehearsal)
125 KVA -04 Sets . (For each day upto 3 days)
125 KVA -04 Sets . (For each single day more than 3 days)
62.5 KVA -08 Sets . (For each day upto 3 days)
62.5 KVA -08 Sets . (For each single day more than 3 days)
Supply & providing on hire basis Earthing with 50 mm dia GI pipe 2.5 to 3 mtrs long and 6/8 SWG GI wire with galvanized nut and bolts washer etc. below the ground level & dismantling the same
Deployment of 06nos technician and 06 nos helper per 8 shift per day for 03 nos of shift per day(i.e 18nos technician and 18nos helper per day=total 36nos ) for carrying out all kind of work related to illumination and other allied work and their operation for proper upkeepment and preventing any unwanted incident like theft wilful damage etc. (For 4days). No additional charges will be paid for any unwanted incidents)
Cost for constructing a temporary rain shed to protect electrical panels, main switches, distribution boards (DBs), changeover switches, and related equipment from rainwater. The structure will be built using bamboo and covered with either polyethylene tarpaulin or aluminum/tin, with size as required.
Transportation charge for the materials from Company's godown to Site and return back to godown after use.
18 % GST on the total amount from item no 1 to 11.
Supply and pouring of HSD for the hired DG set incl. handing cost. (The measurement will be done after considering all technical aspect,orginal invoice & log book)
Special Terms and conditions for Temporary E.I. Work - 1) Earthing should conform to IS specification. Earth Continuity wire should not be broken / Jointed. Single Earth continuity wire should be used from Earth Bus-Bar to the installation. 2) All 3ɸ Electrical Panel Should be earthed by two nos. of separate earthing and 1ɸ panel should be earthed by one no earthing. 3) MCB / Rewirable Fuse type Distrubution Board should be installed with proper Trip Current setting / fuse wires. However, MCB type DBs are preferable. 4) No Part of the Electrical Circuit in the pandal / Structure shall be within 12 inches of any decorative cloth / paper. 5) Ordinary Flexible wires should not be used. Only new PVC insulated & sheathed wires (Bearing ISI mark) or PVC insulated wires of FRLS (Fire Resistant Low Smoke) type (ISI Marked) are allowed. 6) All cable ends should be properly sockedted. 7) All joints shall be made with porceline insulated connectors. Twisted & lapped joints shall be avoided. But Joints are strictly not allowed in the dias. 8) Cables / Wires should run along outside the Dias. 9) Ceiling fan (s) / Electrical fittings must not be suspended from the ceiling of Dias. Pedestal fans are not allowed on the Dias. However, Pedestal fans may be installed outside dias, but the body of the fan must be properly earthed.
10) T/L fittings shall be of box type (Indoor commercial type). Any kind of open type fittings must be avoided. 11) Each A.C. Machine should be connected with a separate circuit and earthing should be provided by separate single earth contunuity wire from Earth Bus-bar. 12) P.A. System and Microphone shoud be earthed. 13) Sufficient quantity of Fire Extinguishers and First Aid Box should be provided. 14) If the DGs are not placed at site on time pro rata rate will be reduced from bill. 15) The guarding /security arrangement of all the hired products /installation has to be made by the successful bidder at his/their own cost and responsibility. No additional charge will be paid for any unwanted incidents like theft, damage due to natural calamities or any other reasons whatsoever. 16) During entire hiring period any fault to the hired installation shall be rectified/faulty items replaced, at the cost of agency. Suitable man power for attending and rectification/replacement of damaged items has to be provided by the agency at their own cost. Rectification time is 1 hour for the event day and upto 2hrs for other days. 17) A test certificate cum safety certificate is to be provided by the agency, duly signed by the Supervisor of the agency after completion of installation. 18) A performance guarantee of hired DG sets and AC machines has to be provided by the agency after completion.
ANAMICA ENTERPRISE (BID ID -6888501)
S. K. CHATTERJEE ELECTRICALS PVT LTD (BID ID -6894404)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .