Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹41.0 L+₹3.3 L (8.73%)Rejected-AOC MAHALAXMI ENCLAVE OPPOSITE SLP COLLEGE MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | L2 | Rejected-AOC ok | |
| 3 | L3₹43.1 L+₹5.4 L (14.2%)Rejected-AOC | L3 | Rejected-AOC ok | |
| 4 | L4₹43.8 L+₹6.1 L (16.2%)Rejected-AOC | L4 | Rejected-AOC ok |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Nov 2020, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION, FITINGS AND FIXTURES AND OTHER CONNECTED WORKS INCL B/R SERVICES AT NEW MH UNDER GE GWALIOR
2020_MES_384476_1
8604/GWL/E8
Open Tender
Miscellaneous Works
Item Rate
335 days
Garrison Engineer Gwalior
As per tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹80,000
Yes
12 Dec 2020
8 Oct 2020
7 Nov 2020
8 Oct 2020
3 Nov 2020
21 Oct 2020
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for exposing GI/CI pipes and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering, and well ramming in layers not exceeding 25 cm, after the pipes have been laid complete all as specified and directed.
Removing excavated material (soils) n. exec 50m and depositing where directed at a level n.exec 1.5 m above the starting point complete all as specified and directed.
S & F in replacement of sluice valve cast iron body (Long Body) class-PN 1.0 with flanged ends drilled suitable for bore of pipe 150mm ISI marked (IS:14846:2000) having SS spindle with iron wheel at top complete with nuts bolts washers rubber gasket etc all as specified and directed.
'-ditto- all as per item No 4 above but of 100 mm dia
'-ditto- all as per item No 4 above but of 80 mm dia
S & F in replacement of foot valves CI conforming to IS 4038, of size 150mm dia including rubber gasket, nuts & bolts etc complete all as specified.
Supply and laying in replacement CI/DI fittings such as bends ( any type, radius and angle) taper any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, cross (all sockets or socket and spigot) coller , caps and plugs, etc. upto 150 mm bore CI/DI pipes complete all as specified and directed.
M & L for servicing of DG set of 63 KVA including replacement of all consumable parts i.e. Engine oil, spinion lube oild filter, Fuel filter element primary, fuel filter element secondary, primary element for KFA- 01-7221, Coolent premix in 10 Ltr cane and all other essential parts required such as fuel level indicator, lub oil pressure sensor, temperature sensor, overload sensor and all other sensors and gauges with soft touch buttons at site, incl servicing and lubricating of alternator, replacement of unsv leads required for battery, complete checking and replacing (if unsv) any other parts of DG set as and when required or as per direction of Engr-in-Charge.
S & F in replacement of lighting arrestor non linear type complete with all fitting distribution class, discharge capacity 65 Kilo Amps current rating 5 KA suitable for 11000 Volts complete connecting with ACSR Jumpers from LA to Air Break switch with PVC Sleeve all as specified and directed
S & F in replacement of high performance LED street light fittings/luminaries of 60 +/- 3 watt power consumption made out of die cast alluminum housing,with high power LEDs as light source and HF electronic driver IP 65 protection.Optical compartment shall be provided with heat resistant toughned glass,while control gearshall be provided with diecast aluminum cover for safety.The LEDs usedin street light should be ANSI standard rated LED with CCT of 6000 K and CRI of 50000 hrs incl multistage constant current constant voltage topology driver suitable to operate in input voltage range of 150 volts to 270 volts (nominal range-240V)with minimum 3 KV surge protection,Power factor greater then 0.95 and total harmnic distortion (THD) of less then 10% should be integral to the luminair incl PVC insulated copper conductor multi stranded single core 2.5 sqmm from fitting to OH line/upto looping terminal box complete all as specified and directed. Make Havell's,model:ENDURA CITILINER NEO 60 W LED 6000 K,Product No: LHETAXU7PN6J 060 or equivalent model in Philips/Wipro/C&S/Bajaj.
S & F in replacement of street lighting control switch 3KW suitable for 3 phase 440V AC 50Hz intergal model with control gear like light sensitive control system, power contactor for load switching, three phase MCB, treminal block etc , pole mounted SV stabilized FR grade special moulding enclosure with cable termination lock and key complete with mounting brackets cable gland etc all as specified & directed . Model No SWADEEP-02EC 5Kw1P of nature switch or equivalent make of INSU.
S&F in replacement of PVC moulded case Junction box outdoor type of size 25x20x15cm with hinged front open door including locking arrangment and with one no MCB SP 10Amp & suitable thimbles with necessary clamps made out of 25 mm flat GI strip , nut,bolt etc and providing copper conductor 2.5 Sqmm from PVC junction box to Street light fitting in and including 20mm dia rigid non metallic HDPE pipe with proper clamping with 25 x 3 mm thick GI strip bolt nut etc in 1.5 m interval all as directed at site.
M & L for servicing of DG set of 400 KVA including replacement of all consumable parts i.e Engine oil as per the manufacturers recommendation spinion lube oil filter, Fuel filter element primary, fuel filter element secondary, primary element for KFA- 01-7221, Coolent premix in 10 Ltr cane and all other essential parts required such as fuel level indicator, lub oil pressure sensor, temperature sensor, overload sensor and all other sensors and gauges with soft touch buttons at site, incl servicing of alternator and lubricating, replacement of unsv leads required for battery, complete checking and replacing (if unsv) any other parts of DG set as and when required or as per direction of Engr-in-Charge.
M & L for complete servicing of Three Phase input supply, three phase output, PWM technology IGBT based, ON_LINE UPS with back up support time of 30 minutes on full load, inclusive of standard maintenance free(SMF) batteries bank with features of feather touch buttons switches and By Pass arrangement facility for emergency operation, with auto change over and protection in case of High and Low voltage, Single phasing etc of capacity 5 KVA including replacement of old burnt MCB of 32 Amps SPN complete all as specified and directed.
Comprehensive maintenance including repairs and routine maintenance of microprocesser controlled VVV frequency drive electric driven passenger lift of 884kg carrying 13 passenger with ARD facility from ground plus two floors consisting of examing, adjusting, lubricating, greasing the parts including replacement of minor parts such as relays, Rectifier and Indication display, Main Contactor transformer, Brake liner and Gear oil, Motor Oil and servicing, Gate lock switches Gate levers, Gate beaks, Gate track rollers, contact switches and limit switches, Floor level indication switch and oscillator switch, Car counter weight shoes and door and Gate Shoes, Pit switch and safety switches, landing floor indicator, car bush buttons and switches and Car indicators, Emergency Alarm Buttons, Up & down indicator cards, Aluminium Brackets,OSG roller and lubrication, Guide lubrication, servicing of auto door, Track rollers, and linking rolls, Door locks contact, Door lubrication and oiling of OSG rope, OSG clips and ,Main rope clips, Rope tension spring, OSG safety switch, Door opening buzzer, stop button, door stopper, car & landing door, door opening and closing belt, Door limit switches all as specified by the Engr-inCharge to be replaced and if any connected items missing for satisfactory operation of lift will be assumed included as the rate quoted against this item rate. The schedule item operated all as specified and as directed by Engr-in-Charge. Make OTIS. (Note :- Replacement of major parts shall be measured and paid seperately. Rate quoted by contractor shall be included for following :- 1. to obtain necessary safety certificate from Lift inspector and submit to the Engr-in-Charge once a while during contract. 3. Weekely serviciability certificate of lift shall be submitted by contractor to Engr-in-Charge. 4. Necessary servicing of lift as per manufacturers instruction shall be carried out be contractor from authorised rep of manufacturer and a report in this regard shall also be submitted to Engr-in-Charge by Contractor)
--ditto-- all as per item No 16 above but lift of of 1020 Kg carrying 15 Passengers. (Make- OTIS)
S & F of door screen sensor with cable for lift of 13 pasangers/15 Passengers complete all as specified and directed. (Make of lift - OTIS, Make of sensor with cable - As per sample)
S & F of VVVF drive suitable for lift of 13 pasangers/15 Passengers complete all as specified and directed. (Make of lift - OTIS, Make of VVVF drive - As per sample)
S & F of PC Board and mother board suitable for lift of 13 pasangers/15 Passengers complete all as specified and directed. (Make of lift - OTIS, Make of PC Board and mother board - As per sample)
S & F of main wheel pulley suitable for lift of 13 pasangers/15 Passengers complete all as specified and directed. (Make of lift - OTIS, Make of main wheel pulley - As per sample)
M & L for rewinding of Door motor suitable for lift of 13 pasangers/15 Passengers complete all as specified and directed. (Make of lift - OTIS)
S & F in replacement of photo electronic type heat cum smoke detector having dual ionized chamber meant for easy detection of high carbonized fumes by means of light emitting principle complete with base, UL, FM, Make: Apolo, System Sensor, Edward, Phillips
Supply, Installation, testing & commissioning in replacement of Zonal indicator panel of upto 6 Zones, having provision for Audio Video indications for FIRE, FAULT, OPEN/SHORT EARTH CIRCUIT duly interfaced with main control panel. The panel shall be factory manufactured in a 1.6 mm thick CRCA powder coated enclosure , shall have self diagnostic features, test facilities complete all as specified and directed. Make- Johnson Control Siemens, Notifier (Honeywell) Safezones, Minimax, Vijay, Electroqip Mather & Platt) (ERTL approved) (Electronics Regional Test Lab approved)
S & F in replacement of micro processor based main control (Fire Alarm main control panel) of upto 10 Zones with battery charging circuit and power supply unit having provision for Audio Video indications for FIRE, FAULT, OPEN/SHORT EARTH CIRCUIT. The panel shall be factory manufactured in a 1.6 mm thick CRCA powder coated enclosure , shall have self diagnostic features, test facilities and shall have 2x12 volts 32’ AH SMF battery set for eight hours continuous back up in case of mains failure. Make- Johnson Control Siemens, Notifier (Honeywell) Safezones, Minimax, Vijay, Electroqip Mather & Platt) (ERTL approved) (Electronics Regional Test Lab approved)
S & F in replacement of repeater panel having provision for Audio Video indications (Alpha Numeric Multi 300) for FIRE, FAULT, OPEN/SHORT EARTH CIRCUIT duly interfaced with main control panel. The panel shall be factory manufactured in a 1.6 mm thick CRCA powder coated enclosure , shall have self diagnostic features, test facilities confirming to IS 2189 . Make- Johnson Control Siemens, Notifier (Honeywell) Safezones, Minimax, Vijay, Electroqip Mather & Platt) (ERTL approved) (Electronics Regional Test Lab approved)
S & F in replacement of input module, ISI marked complete all as specified. Make- Johnson Control Siemens, Notifier (Honeywell) Safezones, Minimax, Vijay, Electroqip Mather & Platt) (ERTL approved) (Electronics Regional Test Lab approved)
S& F in replacement of output module ISI marked, complete all as specified. Make- Johnson Control Siemens, Notifier (Honeywell) Safezones, Minimax, Vijay, Electroqip Mather & Platt) (ERTL approved) (Electronics Regional Test Lab approved)
S & F in replacement of fault isolator unit ISI marked complete all as specified. Make- Johnson Control Siemens, Notifier (Honeywell) Safezones, Minimax, Vijay, Electroqip Mather & Platt) (ERTL approved) (Electronics Regional Test Lab approved)
Supply, Installation, testing & commissioning of response indicators made from 1.6 mm thick CRCA sheet having dual Red LED indications & provision for cable/wire entry from top complete all as specified. Make-Johnson Control Siemens, Notifier (Honeywell) SAFEZONE, MINIMAX ELECTROQUIP, MATHER & PLATT., VIJAY
S & F in replacement of modular type Switch piano; flush type, single pole, one way, one module 5/6 Amp 230V, AC, 50Hz ISI marked with valid CML No. complete all as per Cat No. 573400 of legrand or equivalent in Crabtree,Wipro, L&T or Anchor.
S & F in replacement of modular type Switch piano; flush type, single pole, one, one way 16 Amps 230V, AC, 50Hz IS: 3854 marked with valid CML No. complete all as per Cat No. 573410 of legrand or equivalent in Crabtree,Wipro, L&T or Anchor.
S & F in replacement of Modular type Socket outlet multipurpose having provision for 3 pin, 5 Amp and 2 pin, 5 Amp, piano flush type 230V, AC, 50Hz ISImarked with valid CML No complete all as per Cat No. 573470 of legrand or equivalent in Crabtree,Wipro, L&T or Anchor.
S & F in replacement of Modular type Socket outlet multipurpose having provision for 3 pin, 16 Amp and 3 pin, 6 Amp, piano flush type 230V, AC, 50Hz ISI marked with valid CML No complete all as per Cat No. 573471 of legrand or equivalent in Crabtree,Wipro, L&T or Anchor.
S & F in replacement of Modular type fan regulator electronic step type 240 Volts, 100 Watts two module ISI Marked with suitable CML No. and connecting up complete as per Cat No. 573463 of legrand or equivalent in Crabtree, Wipro, L&T or Anchor.
S & F in replacement of Modular Switch piano; flush type, single pole, two ways, 5/6 Amp 230V, AC, 50Hz ISI marked with valid CML No. completes all as per Cat No. 573402 of legrand or equivalent in Crabtree, Wipro, L&T or Anchor.
S & F in replacement of modular bell push piano type 230V Ac single phase module all as per cat No 573413 of legrand or equivalent in Crabtree,Wipro, L&T or Anchor.
S & F in replacement of ding - dong / multi musical type 230V Ac single phase module Make: legrand or equivalent in Crabtree, Wipro, L&T or Anchor.
S&F in replacement of LED 22w tube light fitting, box type, suitable for tube light 22 Watts made of light weight extrusion aluminium channel , pre-wired with high efficiency electronic ballast especially designed for LED Tube light source suitable for surface mounting on wall, ceiling or using conduit suspension also including single tube 1x22 W LED Tube light complete, spring loaded rotor type lamp holders, all accessories prewired including connecting with PVC insulated multi stranded copper flexible cable of size 0.50 Sqmm three core, all as specified and directed. Make : HPL Cat No HLPLEDDT522 Utilite or equivalent of Bajaj, Phillps, Crompton Greaves, Wipro.
M & L for taking down the unsv ceiling fan, dismantling of blades, replacement of unsv parts i.e bearing, bushes, capacitors, canopy etc incl PVC insulated copper codnuctor of 1.5 sqmm wire for necessary electrical connection from ceiling rose to connector of fan and refixing the same in its original position complete all as specified and directed by Engr-in-Charge
M & L for taking down the unsv ceiling fans, dismantling its blades, rewinding the fan and re-fixing the same in its original position incl testing on completion all as specified and directed by Engr-in-Charge
M & L for taking down the unsv exhaust fan of any size and capacity, dismantling of blades, replacement of unsv parts i.e bearing, bushes, capacitors, canopy etc incl PVC insulated copper codnuctor of 1.5 sqmm wire for necessary electrical connection from ceiling rose to connector of fan and refixing the same in its original position complete all as specified and directed by Engr-in-Charge
M & L for taking down the unsv exhaust fans of any size and capacity, dismantling its blades, rewinding the fan and re-fixing the same in its original position incl testing on completion all as specified and directed by Engr-in-Charge
M & L for taking down the unsv wall mounted fan , dismantling of blades, replacement of unsv parts i.e bearing, bushes, capacitors, canopy etc incl PVC insulated copper codnuctor of 1.5 sqmm wire for necessary electrical connection from ceiling rose to connector of fan and refixing the same in its original position complete all as specified and directed by Engr-in-Charge
M & L for taking down the unsv wall mounted fans, dismantling its blades, rewinding the fan and re-fixing the same in its original position incl testing on completion all as specified and directed by Engr-in-Charge
S&F in replacement of energy saving and enviornment friendly long life LED security light fitting 1 x 15W LED, versatile pressure die cast aluminium IP-66 protection with high power LED as light source and arcylic cover etc all acessories prewired complete including mounting bracket of 40 mm dia light grade GI pipe of required length and shape incl bending, forging or welding etc necessary connection to ceiling rose etc & suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 Sqmm three core from ceiling rose to fitting complete all as specified and directed. Make:Havells cat No LHEWEBP7PL6S015 or equivalent in Crompton Greaves, Bajaj , wipro.
Supply and fixing in repairs of MCCB 400 Amp rated capacity, 36 KA 415 Volts, 4 pole including necessary electrical connection in existing LT Panel including taking down old unsv complete all as specified and directed. (Make :- Havells, L & T, Standard)
All as per item No 47 above but of 200 Amp rated capacity, 25 KA, 415 Volts, 4 pole (Make :- Havells, L & T, Standard)
All as per item No 47 above but of 100 Amp rated capacity, 16 KA, 415 Volts, 4 pole (Make :- Havells, L & T, Standard)
All as per item No 47 above but of 63 Amp rated capacity, 16 KA, 415 Volts, 4 pole (Make :- Havells, L & T, Standard)
S&F in replacement of the LT UG XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of the following sizes all as specified and directed by Engr-in-Charge :-
300 Sqmm 3 1/2 Core
240 Sqmm 3 1/2 Core
185 Sqmm 3 1/2 Core
150 Sqmm 3 1/2 Core
120 Sqmm 3 1/2 Core
95 Sqmm 3 1/2 Core
50 Sqmm 3 1/2 core
35 Sqmm 3 1/2 Core
25 Sqmm 4 Core
M&L for sand cushioning to underground cable in trenches all as specified and directed.
M & L for Bricks; common burnt clay sub class 'A' laid dry in cable protection of size 230 x 110 x 70 mm complete all as spfd and directed
Comprehensive maintenance of Modular OT and Medical gas system including Weekely routine checkup of complete medical gas system, air compressors, vaccum pumps including pipe lines, Anesthetic gas scavanging system including their manifold , oxygen gas control station comprising of 8 + 8 cylinder manifold complete, nitrus gas oxide gas control station comprising of 2 + 2 cylinder manifold, rectification of any type of leakages in medical gas pipe lines and modular OT with their complete accessories installed in modular OT. Modualr OT Gate (auto sensor type), Shadowless OT light etc and carryout required periodical maint as and when required or directed by Engr-in- charge. (Note :- Replacement of major parts shall be measured and paid seperately. Rate quoted by contractor shall be included for following :- 1. Weekely serviciability certificate of compete medical gas system and modular OT with its complete fittings shall be submitted by contractor to Engr-in-Charge. 2. Necessary servicing of complete medical gas system and equipment installed in modular OT as per manufacturers instruction shall be carried out be contractor from authorised rep of manufacturer and a report in this regard shall also be submitted to Engr-in-Charge by Contractor)
M & L for replacement of unsv auto sensor installed in modular OT gate complete all as specified and directed. (Make :- as per sample)
S & F in replacement of all Hepa filters installed in modular OT in every four months as per sample all as specified and directed by Engr-in-Charge.
S & F in Repair/replacement of complete electrical services i.e. replacement of MCBs/starters, connected electrical wirings etc or any other services for smooth functioning of medical gas systm/Modular OT as and when required or directed by Engr-in-Charge.
Comprehensive maint and servicing of complete fire fighting system including the Weekely routine checkup of complete fire fighting, fire alarm and fire warning system including carryout periodical maint of complete fire fighting, fire alarm and fire fighting system as and when required or directed by Engr-in- charge. Contr is also resp to submit the weekely maint record sheet/serviceability cert to this office duly signed by Contr and MES rep.
S & F in Replacement of unsv 'C' class hydrant, single outlet hydrant, hose reel (as per sample) and two way collecting head etc as per sample when ever required or as directed by Engr-in-Charge
S & F in replacement of PA system with 6 watt ceiling speaker, 100 watt amplifier and microphone set as and when required or directed by Engr-in-Charge. (Make :- as per sample)
M & L for Dismantling / taking down of electric motor of centrifugal pump 60 HP, AC, 3 phase, 415 volts from site after disconnecting from pump & electric connection for rewinding, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, and reassembling after repairs and replacement of parts as required, end plates, coupler pulley, cooling fan and terminal blocks etc and refixing the same at site incl. electric connections , install, testing and commissioning for satisfatory function as and when required or as directed by Engineer - in - charge.
M & L for Dismantling / taking down of electric motor of jockey pump of 15 HP, AC, 3 phase, 415 volts from site after disconnecting from pump & electric connection for rewinding, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, and reassembling after repairs and replacement of parts as required, end plates, coupler pulley, cooling fan and terminal blocks etc and refixing the same at site incl. electric connections , install, testing and commissioning for satisfatory function as and when required or as directed by Engineer - in - charge.
M & L for servicing of Diesel driven water pump of 60 HP capacity including replacement of all consumable parts i.e engine oil, spinion lube oild filter, Fuel filter element primary, fuel filter element secondary, primary element for KFA- 01-7221, Coolent premix in 10 Ltr cane and all other essential parts required such as fuel level indicator, lub oil pressure sensor, temperature sensor, overload sensor and all other sensors and gauges with soft touch buttons at site, replacement of unsv leads required for battery, complete checking and replacing (if unsv) any other parts of Diesel driven Pump set as and when required or as per direction of Engr-in-Charge.
S & F in repairs of any type and capacity of unsv starter (as per sample and installed in Fire pump house/water supply pump house) in existing LT Panel including making necessary electrical connection and testing on completion incl taking down old unsv one as and when required or as directed by Engr-in-Charge.
M.S. ENGINEERS
Arkay Instrumentation
mahamaya constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .