Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid L1 rank is competitive and reasonable during Scrutiny amongst bidders | |
| 2 | L2₹11.4 L+₹1.1 L (10.5%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹12.5 L+₹2.2 L (21.0%)Rejected-AOC 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹13.0 L+₹2.8 L (26.7%)Rejected-AOC | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹15.5 L+₹5.2 L (50.4%)Rejected-AOC | L5 | Rejected-AOC Not Lowest |
Tender Value
₹14.6 L
EMD Value
₹29,160
Closing Date
18 Jan 2025, 6:00 pmClosed
CWE (AF) BAMRAULI
HQ CWE (AF) BAMRAULI, PRAYAGRAJ-211012
ADDITION / ALTERATION TO BLDG NO P-395 AND PROVN OF KOTA STONE IN ARMOURY AT AF STN BAMRAULI
2024_MES_689767_1
87475/E8
Open Tender
Civil Works
Item Rate
182 days
BAMRAULI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) BAMRAULI
₹29,160
Yes
8 Feb 2025
21 Dec 2024
20 Jan 2025
21 Dec 2024
18 Jan 2025
4 Jan 2025
21 Dec 2024 - 28 Dec 2024
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in foundations, footing, plinth beams, bases for columns and mass concrete complete all as specified and directed (reinforcement to be measured separately).
M&L for reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in columns, pillars, posts & struts complete all as specifed and directed (reinforcement to be measured separately).
M&L for reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in lintels over 1.5m clear span, beams and cantilevers complete all as specified and directed (reinforcement to be measured separately).
M&L for reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in chajjas complete all as specified and directed (reinforcement to be measured separately).
Form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
Form work to sides of square or rectangular columns, pillars, posts and struts for rough finished surfaces of concrete complete all as specified and directed.
Form work to sides & soffits of lintels over 1.5m clear span, floor or roof beams, cantilevers, etc for rough finished flat surfaces of concrete complete all as specified and directed.
Form work to chajjas and similar items including edges for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair complete all as specified and directed
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, with using water proofing compound @ 3% by weight of cement, surfaces finished even and fair complete all as specified and directed.
Hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in levelling courses, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars 5 to 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in floors and paving, 100 mm thick, laid in panels complete all as specified and directed.
M&L for preparation of newly plastered or undecorated surface of wall and applying two coat of plastic emulsion paint over 1 mm thick wall care putty and primer complete all as specified and directed.
M&L for preparation of newly plastered or undecorated surface of wall and applying two coat of exterior emulsion paint over 1 mm thick wall care putty and primer complete all as specified and directed.
S&F for rolled mild steel sections conforming to Gde Fe-410-0 or Fe-310-0 as in roof trusses (framed) and trussed purlins including distance pieces, cleats etc complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10 cm but not exceeding 15 Cm long and dia of shank 16 to 20 mm complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating 275 GI based corrugated steel sheet 0.50 mm thick of any colour having tensil strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide primer complete all as specified and directed
S&F 12mm thick plain / froasted toughened glass fixed type on opening and shelfs, partition including cutting and grooving on wall with aluminium frame, rail, handle, lock with SS fixtures etc. complete all as specified and directed.
Taking down chowkhat or frame with shutters (without taking off shutters from the frame) n. exc. 1.5 Sqm each complete all as specified and directed.
M&L for Aluminium (powder coated) sliding glazed shutter of suitable size of 3 lane with frame including fixing glass, cleats, glazing clips, rubber gasket, aluminium snap beading and locking arrangement at both end all as specified and as shown and drawing. Notes: (i) Thickness of powder (epoxy polyster) coating shall not be less than 50 Micron (ii) Shade/tint of powder coating (epoxy polyster) shall be as approved by GE.
M&L for sheet glass 5.5 mm thick, ordinary quality and glazing with rubber beading fixed with panel pins in square exceeding 0.5 Sqm in each pane complete all as specified and directed.
M&L for vitrified ceramic tiles 8-10 mm thick dark shade (square/rectangular) polished, area of each tilesexceeding 0.36 but not exceeding 0.42 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid in floors set and jointed as per manufacturer's instructions over including including 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, staircases, landings and similar suspended work (reinforcement cut as required to facilitate demolition) and removing demolished material outside defence land complete all as specified and directed.
S&F in position premium sand textured finished mineral fibre acoustical ceiling tiles of size 600x600x16mm thick and placed on GI grid power coated snap grid ceiling 600x600 module constiting of wall angle section 19x19 mm and tee section and web height of 38mm and flange 15mm (colour white) (having rotary sticting on all T-section ) with suspension sytem all as approved by GE including taking down old false ceiling complete all as specified and directed.
M&L complete removal of existing treatment on walls and applying two coat of plastic emulsion paint over 1 mm thick wall care putty complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of wall projection, face of chhajja, projected face of roof slab and face and side of sun shade etc. by brooming down or scrapping sown with steel wire brush and applying two coat of exterior emulsion paint complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of ceiling and applying one coat of distamper oil emulsion complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20-25 mm thick, over and including 20 mm thcik cement screed base in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and beeswax polishing complete all as specified and directed.
M&L for Kota stone slab 16 mm thick (minimum) in riser of steps, skirting, dado and pillar, laid over and including 10 mm cement screed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and beeswax polishing complete.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work, surfaces finished even and fair complete all as specified and directed.
Taking down carefully aluminium batten point wiring for light / fan / socket / bell or power point complete all as specified and directed.
M&L for point complete with 1.5 sqmm (nominal area) single core PVC insulated and unsheathed FRLS stranded copper conductor cable 1100 Volt grade drawn in and including concealed PVC conduit of size not less than 20mm, ISI marked including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity, fabricated branded modular flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches, socket outlets and fan regulators etc. completed all as specified and directed for the following: -
One light / fan point controlled by one switch single pole one way.
One 3 pin and 56 Amp switch socket out let on the same board with other switch.
All as above item here-in-before but using 2 Nos 4 sqmm size for main cable and 1 No 4 sqmm size as earth conductor for one 16 Amp switch socket outlet on independent board complete all as specified and directed.
S&F switch modular flush 6 Amp, single pole, one way ISI marked complete all as specified and directed.
S&F modular socket 6 Amp, 3 pin, 2 module ISI marked complete all as specified and directed.
S&F switch modular flush 15/16 Amp, single pole, one way ISI marked complete all as specified and directed.
S&F modular socket 16 Amp, 2 in 1, 3/5 pin combined, 2 module ISI marked complete all as specified and directed.
S&F ceiling rose surface polycarbonate three terminals complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED batten extruded surface mounting fitting 2 feet long aluminium housing 10 watt input voltage 220 volty inbuild LED and driver complete all as specified and directed.
S&F wall mounted fan 400 mm sweep, 230 volt, 50 Hz, 1420 RPM with 90 degree oscillation and having speed control by two pull cord system complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 08 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.
S&F MCB, single pole and neutral, 230 volts, 32 Amp rating ‘C’ series fixed in DBs catered here-in-before complete all as specified and directed.
S&F MCB, Single Pole, 6 to 32 Amps rating 240V, 10KA, 'C' curve complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply, laying, testing and commissioning of LT UG cable, XLPE insulated, screened PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm, 2 core complete all as specified and directed.
Abhinav Builders (BID ID -3211908)
chauhan construction (BID ID -3211562)
M/S SWASTIK BUILDERS (BID ID -3211233)
M/S Aquarius Construction (BID ID -3211932)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .