Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.2 LAccepted-AOC H 27 UPPER GROUND FLOOR MOHAN GARDEN UTTAM NAGAR NEW DELHI DELHI 110059 | WEST | DELHI | 110059 | L-1 | Accepted-AOC Found lowest | |
| 2 | L-2₹20.2 L+₹2,085 (0.10%)Rejected-Finance | L-2 | Rejected-Finance Not found lowest | |
| 3 | L-3₹22.7 L+₹2.5 L (12.4%)Rejected-Finance F 23 B FIRST FLOOR VARDHMAN CENTRAL MALL LSC NEHRU VIHAR MUKHERJEE NAGAR NORTH DELHI DELHI 110054 | CENTRAL DELHI | DELHI | 110054 | L-3 | Rejected-Finance Not found lowest | |
| 4 | L-4₹26.9 L+₹6.7 L (32.9%)Rejected-Finance C 470 YOJANA VIHAR YOJANA VIHAR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | L-4 | Rejected-Finance Not found lowest | |
| 5 | Rejected-Technical SCO 365 366 SCO 365 366 SECTOR 35B CHANDIGARH SECTOR 35B CHANDIGARH CHANDIGARH 160022 | CHANDIGARH | CHANDIGARH | 160022 | - | Rejected-Technical Documents related to EMD declaration, GSTN PAN ESI EPF, similar work Completion certificate, SHR, Compressor and Air filter not found as per NIT. Bidder name and document signed are also mismatched |
Tender Value
₹21.6 L
Closing Date
18 Nov 2021, 5:00 pmClosed
Director
CSIO Sector 30 Chandigarh
HVAC work for revamping of ICT infrastructure in CSIR CSIO Sector 30 Chandigarh
2021_CSIR_93465_1
CSIO/P50(26)/2021-22/Ref AC
Open Tender
Electrical Works
Item Rate
120 days
CSIO Sector30 Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
7 Jan 2022
8 Nov 2021
22 Nov 2021
8 Nov 2021
18 Nov 2021
8 Nov 2021
Amount
Precision Air conditioning System Floor mounted Top flow, DX type Precision Air condtioners with microprocessor based controller The Indoor unit shall comprise of Digital Scroll Compressor, Evaporator Fan complete with Backward curved type with EC motor, Evaporator DX Cooling Coil, Microprocessor controllers, Thermal Expansion valve, Driers, G4 Filter, Suction and Discharge piping, Internal power and Control wiring, Crankcase heaters, HP/LP Cutouts, Power and Control contactors and Other Electrical accessories.The Outdoor Condenser unit shall comprise of Condenser fans & motor, Condenser cooling coil (Copper coil with aluminium fins), Fan speed controller (Variex), Isolater switch.The unit shall be suitable for operation on 415 Volts, 50 Hz, 3 Phase, 4 Wire AC supply. Each unit should be having individual display panel, which shall display date, time, actual & set values, operating conditions, signal faults, collective faults, limiting values and PAC wellness alarm / service alarm to reduce the down time and unit memory shall hold the most recent events with ID number, time and date stamp for each event.Both LAN and BMS connectivity.Bottom flow Air Cooled DX type Precision Air condtioners of below mentioned Tr cooling capacity
With above mentioned specification Precision Air Conditionres of capacity 10 TR + 1
Lifting,shifting, ,Installation & commissioning of Precision AC units including with all accesseries.
Interconnecting 18G Copper piping between indoor & outdoor unit. Copper piping will be duly insulated with in the AC space@20 meter/machine
Supply of Interconnecting copper cabling between indoor & outdoor unit with GI tray
Supply of Condensate drain piping with 40NB CPVC- B class pipes
Supply of Humidifier water piping with 25NB CPVC-B class pipes
Supply of Green refrigerant(R 410A)
Supply of MS adjustable indoor stand as per manufcturer standard
Supply of MS adjustable outdoor stand as per manufcturer standard
Main cable from MCB to machine
Supplying and fixing of 19 mm duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
Labour charges for Dismentling, shifting, reinstallation, Nitrogen leak testing for tower air conditioner of 3 ton capacity as per site requirment
Supply & fixing of suction & discharge line copper pipe (3/8" & 5/8") with isulation and wraping with tape
Supply & fixing of electrical wire 4 core 2.5 sq mm in conduct pipe
Supply and fixing of 25 mm PVC pipe for condensed AC drain water with necessay joints, clamps etc
Installation of window Air conditioners with wooden frame
FEDIN ENGINEERING PRIVATE LIMITED
AB3S SOLUTIONS PVT LTD
CYPRESS SOLUTIONS PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .