| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC | ₹2.1 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹2.6 Cr+₹51.8 L (24.3%)Rejected-Finance | ₹2.6 Cr+₹51.8 L (24.3%) | L2 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹1.6 Cr
EMD Value
₹2.4 L
Closing Date
1 Sept 2021, 6:00 pmClosed
CE Bathinda Zone
HQ CE Bathinda Zone Bathinda Mil Stn
PROVN OF OTM ACCN FOR DSC PL (AMWP 01/19-20) AT BATHINDA MIL STN
2020_MES_393058_2
CA NO. CE BTZ/BTD/TOKEN-08 OF 2020-21
Open Tender
Civil Works
Lump-sum
300 days
Bathinda Mil Stn
as per NIT
8 documents required · 8 mandatory
₹1,000
GE (I) (P) No. 1 Bathinda
₹2.4 L
Yes
28 Dec 2021
10 Aug 2021
3 Sept 2021
10 Aug 2021
1 Sept 2021
20 Aug 2021
Amount
SCHEDULE 'A' SECTION-I (BUILDING/STRUCTURE WORKS)
Lump sum price worked out by the tenderer for “Building Work / Structure Work” as listed in Schedule ‘A’ Section - I.
SCHEDULE 'A' SECTION-II (PART-I) (INTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORK” as listed in Schedule ‘A’ Section - II (Part-I)
SCHEDULE 'A' SECTION-II (PART-II) (INTERNAL ELECTRIFICATION WORKS)
M&L for Point wiring complete with 1.5 sqmm (Nominal cross sectional area) PVC insulated FRLSH un-sheathed and multistranded copper conductor cable with colour coding, ISI marked, for phase, neutral and earth with and including rigid PVC concealed conduit ISI marked and conduit fittings for one light point/fan point /engagement light controlled by one switch including connecting earth wire to common earth and connecting to earth dolly with & including pressed steel powder coated sunken box of suitable size made out of 1.6mm thick sheet and covered with & including 3 mm thick bakelite laminated hylem sheet (ISI marked) top cover etc., complete all as specified and as directed.
All as per Srl No.5.00 here-in-before but one three pin socket outlet 5 Amps on the independant board.
All as per Srl No.5.00 here-in-before but one three pin socket outlet 5 Amps on the same board.
All as per Srl No.5.00 here-in-before but controlled by two, 2-way switches complete all as specified and directed.
M&L Point wiring complete with 2.5 sqmm (Nominal area) PVC insulated FRLSH un-sheathed and multistranded copper conductor cable with colour coding, ISI marked, for phase, neutral and earth with and including rigid PVC concealed conduit medium quality and conduit fitting for 5 pin 15 Amp multipurpose switch socket combination including connecting earth wire to common earth and connecting to earth dolly with & including pressed steel powder coated sunken box of suitable size made out of 1.6mm thick sheet and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified and as directed.
NOTE FOR POINT WIRING (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) MS boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed.
Switch piano, flush type, single pole, two way, 6 Amp, fixed on laminated sheet top cover complete all as specified and as directed. Note :- Cost of plastic laminated sheet cover for mounting of switch is included under respective item of point wiring.
Factory made DB (made out of CRCA sheet) TPN, 4 Way (8+12 modules), double door, having earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting RCBO / MCB / MCCB/ Isolator etc, conforming to IS-8623, BS-5484 dust and vermin proof, complete all as specified and as directed. Note :- RCBO / MCB / MCCB/ Isolator etc shall be measured and paid separately under respective items.
MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified and as directed.
MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified and as directed.
MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40 Amp complete all as specified and as directed.
Blanking plate of plastic and fixed in location (Suitable for distribution board)
Ceiling fan of 1400 mm sweep, BEE approved, rating not less than 2 star, induction type motor, single phase, AC supply, 240 Volt, including canopies, three number blades, down rod, double ball bearing with capacitor of 2.5 mfd and making connection with and including PVC insulated PVC sheathed copper conductor flexible cable of size 1.0 sqmm, 3 core from ceiling rose or connector to fan including marking of MES number, complete all as specified and as directed. NOTE:The length of suspension down rod shall be as per site requirement.
Exhaust fan 300 mm sweep heavy duty metal body, mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable of size 1.0 sqmm, 3 core drawn in flexible PVC conduit from ceiling rose or connector to fan including marking of MES number and fixed in position by using 4 Nos, 200 mm long, 12 mm dia fasteners, nuts, washers grouted in wall with CM (1:3), complete all as specified and as directed.
Exhaust fan 450 mm sweep heavy duty metal body, mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable of size 1.0 sqmm, 3 core drawn in flexible PVC conduit from ceiling rose or connector to fan including marking of MES number and fixed in position by using 4 Nos, 200 mm long, 12 mm dia fasteners, nuts, washers grouted in wall with CM (1:3), complete all as specified and as directed.
Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible multistranded copper conductor 1.1 KV grade ( main cable : 2 runs of 4 Sq.mm main cable alongwith one run of single core 4 Sq.mm for earthing) drawn through and including 20mm medium grade PVC rigid conduit, complete all as specified and as directed. NOTE:Three runs of copper conductor and one run of PVC conduit including accessories shall be measured and paid as one unit.
Rigid non metallic, PVC concealed conduit of size 20 mm bore, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for TV & telephone wiring and the like complete all as specified and as directed.
Wiring with TV coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a copper wire net for TV antenna from terminal boxes to TV socket complete all as specified and as directed. (conduit pipe and fittings shall be measured and paid separately).
Wiring with twin core PVC insulated sheathed cable with copper conductor having single strand of 0.4 mm dia one pair taped for telephone wiring from terminal box to telephone socket complete all as specified and as directed. (conduit and conduit accessories shall be measured and paid separately).
GI/pressed steel box flush mounted 100mm x100mmx50mm having holes for 20 mm conduit entry including 3 pin telephone socket outlet flush type duly marked with symbol of telephone and 3 mm thick plastic laminated sheet cover complete for telephone connection complete all as specified and as directed.
GI/pressed steel box flush mounted 100mm x100mmx50mm having holes for 20 mm conduit entry including 2 pin TV socket outlet flush type duly marked with symbol of TV and 3 mm thick plastic laminated sheet cover complete for TV connection complete all as specified and as directed..
Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4 mm dia by means of GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C-2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
LED mini light fitting 1 x 5 Watt, extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and as directed:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CCT : 6500K (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CRI : Morethan 80 (m) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Batten holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, including LED lamp minimum 3 star rated 7W LED B-22 base complete all as specified and as directed with following specifications of LED lamp;- (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : More than 80
LED light fitting 1 x 10 Watt, appx 2 feet long extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and as directed :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CCT : 6500K (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CRI : More than 80 (m) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
LED complete fitting including batten and T-8 Retro LED polycarbonate 1 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications complete all as specified and as directed.:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap . (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Energy efficient LED street light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications complete all as specified and as directed :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : More than 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Brackets made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 50x3 mm for fixing of bracket on steel tubular/ PCC poles with suitable nuts and bolts including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
SUBTOTAL
SCHEDULE 'A' SECTION-III (INTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORK” as listed in Schedule ‘A’ Section - III
SCHEDULE 'A' SECTION- IV (Part-I) (SEWAGE DISPOSAL WORKS)
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Section -IV (Part-I)
SCHEDULE 'A' SECTION- IV (Part-II) (SEWAGE DISPOSAL WORKS)
Supply and fixing PVC septic tank of capacity 6 users (minimum 2000 ltr) designed to carry sewage and sullage water, including excavation and earth work in any type of soil, installed over and including 100mm thick PCC (1:4:8) type D-2 over 100mm stone hard core including all necessary fittings for connecting to inlet and out let, complete all as specified and as directed.
Supply and fixing PVC septic tank of capacity 16 users (minimum 5000 ltr) designed to carry sewage and sullage water, including excavation and earth work in any type of soil, installed over and including 100mm thick PCC (1:4:8) type D-2 over 100mm stone hard core including all necessary fittings for connecting to inlet and out let, complete all as specified and as directed.
Subtotal
SCHEDULE 'A' SECTION-V (Part-I) (BITUMINOUS ROAD WORKS)
Lump sum price worked out by the tenderer for “BITUMINOUS ROAD WORKS” as listed in Schedule ‘A’ Section -V (Part-I)
SCHEDULE 'A' SECTION-V, (PART-II) (BITUMINOUS ROAD WORKS)
Road marking/painting 3mm thick film as lines, dashes, arrows etc. using Hot applied retro-reflective thermoplastic road marking paint (in any colour as direccted like white, golden, yellow, orange black etc.) confirming to MORT & H (clause 803.4) with 8% glass beads, using special applicator machine with heating arrangement upto 160 °C including cleaning and drying the existing surface to ensure dust free and moisture free surface before applying the paint complete all as specified and as directed.
SUB TOTAL
SCHEDULE 'A' SECTION - VI (PART-I) (INTERLOCKING PAVER BLOCK WORKS)
Lump sum price worked out by the tenderer for “INTERLOCKING PAVER BLOCK WORKS” as listed in Schedule ‘A’ Section -VI (PART-I)
SCHEDULE 'A' SECTION-VI, (PART-II) (INTERLOCKING PAVER BLOCK WORKS)
60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment, shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over and including 25mm thick layer of sand and filling the interstices etc with sand complete all as specified and as directed.
Factory made kerb stone, quoin blocks, apex stones, boundary pillars etc of size as directed with plain fair faces, chamfers, weatherings, slightly rounded or chamfered angles etc made by using PVC / Rubber moulds on Vibrating Table Machine with grey cement and no pigment with PCC M-20, nominal mix, laid and setting in cement mortar (1:4) complete all as specified and as directed.
SUB TOTAL
SCHEDULE 'A' SECTION-VII (RCC HUME PIPE CULVERT WORKS)
Lump sum price worked out by the tenderer for “RCC HUME PIPE CULVERT WORKS” as listed in Schedule ‘A’ Section -VII
SCHEDULE 'A' SECTION - VIII (CHAIN LINK FENCING WORKS)
Lump sum price worked out by the tenderer for “CHAIN LINK FENCING WORKS” as listed in Schedule ‘A’ Section -VIII
SCHEDULE 'A' SECTION - IX (AREA DRAINAGE WORKS)
Lump sum price worked out by the tenderer for “(AREA DRAINAGE WORKS” as listed in Schedule ‘A’ Section -IX
SCHEDULE 'A' SECTION - X, (PART-I ) (EXTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Section -X (Part-I)
SCHEDULE 'A' SECTION - X, (PART-II ) (EXTERNAL WATER SUPPLY WORKS)
Material and labour for tapping from existing line of any size for branch conncetion 50/40mm dia GI tubing including all fixtures and fittings as per site requirement including drilling/cutting/threading etc complete all as specified and as directed.
Construction of valve pit size 750 mm X 750 mm X 750 mm of brick masonry construction including cover of MS sheet 3.15 mm thick and angle iron 40mm x40mmx 6mm with hinges, handle and locking arrangement including painting with two coat of synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement mortar 1:3, foundation concrete 1:3:6 including necessary earthwork complete all as specified and as directed and shown on drawings.
Subtotal
SCHEDULE 'A' SECTION - XI, (PART-I) (EXTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORKS” as listed in Schedule ‘A’ Section -XI (Part-I)
SCHEDULE 'A' SECTION - XI, (PART-II) (EXTERNAL ELECTRIFICATION WORKS)
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing complete all as specified and as directed for following sectional area: -
10 Sq. mm x 2 core
10 Sq. mm x 4 core
NOTE for item 68.01 to 68.02:- Excavation and earth work, sand cushioning, protection cover & GI pipe shall be measured and paid for separately.
Energy efficient LED street light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications complete all as specified and as directed:- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : More than 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Brackets made out of GI tubing light grade 40mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 50x3 mm for fixing of bracket on steel tubular/ PCC poles with suitable nuts and bolts including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Junction box of size 200x160x98mm/200x140X95mm or any other higher size (pole mounting) and should be insulated and made out of polycarbonate with glass fiber re-inforced material having IP66 protection in accordance with IEC 60529, with aluminium bus bar suitable for Single phase & Neutral including one No. MCB 0.5 Amp to 1.0 Amps SP, 'c' curve fixing with and including clamp made out of MS Flat iron size 25x3 mm including suitable size of nuts, bolts and washers including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed. Note :- (a) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60670-22, IEC-60670-22, IEC 60670-2 to 5 and color according to RAL 9011. (b) The manufacturer of junction box shall submit a copy of IEC certificate. (c) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. It should be tested at Glove Wire test for 960°C. (d) The degree of protection of enclosure against mechanical load shall be in accordance with EN 50298 for IK08.
Sand cushioning using clean local tibba fine sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- Punned thickness shall be considered for payment purpose.
GI tubing light grade of size 40 mm bore, ISI marked, fixed to wall, poles or laid in trenches for cable protection including fittings complete all as specified and as directed.
Cable path indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia and 8 mm thick with provision of 600 mm long (minimum) single leg/stand of angle iron 25 x 25 x 3 mm, welded/riveted on back side of plate, fixed and grounted in position with PCC type C-1, block of size 300mm x 300 mm x 200 mm complete all as specified and as directed.
Three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5 Sq.mm 1100 volt, drawn through steel tubular poles for connection to street light from junction box complete all as specified and as directed.
Supply & laying sub-class 'B' bricks as specified in particular specifications Section-II clause 5.2, for cable protection, laid lengthwise perpendicular to the axis of cable, adjacent to each other, complete all as specified and as directed.
Excavation by trenchless technology for boring of holes under road, pavement, hard-standing using trenchless boring machine or by means of manual manpower including passing HDPE pipe of 100/150mm dia suitable for 0.4mpa working pressure, complete all as specified and as directed.
Subtotal
SCHEDULE 'A' SECTION - XII, (PART-I) (HOT WATER SUPPLY WORKS)
Lump sum price worked out by the tenderer for “HOT WATER SUPPLY WORKS” as listed in Schedule ‘A’ Section -XII (Part-I)
SCHEDULE 'A' SECTION - XII, (PART-II) (HOT WATER SUPPLY WORKS)
Supply, installation, testing and commissioning of 'Solar hot water system of capacity 300 ltrs per day' including flat plate collector and other required accessories insulated stainless steel storage tank to be placed on building roof at a suitable height with aluminium cladding angle iron structure cold water tank with inter connection between tank and solar panel and necessary structure and finishing work, foundation including electric back up of 3 KW and electric panel with MCBs and other safety devices such as thermostat relays etc., complete all as specified and as directed. NOTES (i) Quoted rate deems to be inclusive cost of stainless steel hot water tank, cost of fabrication & errection of tank staging for cold backup water tank & hot water storage tank using 50x50x6mm MS angle iron sections & 50x5mm MS flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer. (ii) Cold water piping, hot water piping, cold water tank, electric wiring up to solar panel, MCB and DB shall be measured and paid separately under respective items of Sch 'A'. (iii) Solar water heater shall be installed by the authorised representative of the manufacturer only.
Rotational moulded three layer polyethylene water storage tank of capacity 500 litre cylindrical vertical with closed top) conforming to IS-12701-1996 hoisted and fixed in position including provision of cast copper alloy float valve 25 mm bore size complete all as specified and as directed. (qty 01 for hot water supply and 01 for summer appliances)
Subtotal
SCHEDULE 'A' SECTION - XIII, (PART-I) SUMMER APPLIANCES WORKS
Lump sum price worked out by the tenderer for “SUMMER APPLIANCES WORKS” as listed in Schedule ‘A’ Section -XIII (Part-I)
SCHEDULE 'A' SECTION - XIII (PART-II) (SUMMER APPLIANCES WORKS)
Frost free double door refrigerator electric driven single phase 230 volts, AC 50 Hz, of capacity minimum not less than 230 litre with BEE approved, not less than 3 star rating with inbuilt electronic voltage protection complete including electric connection through buck/ boost transformer complete all as specified and as directed.
Water cooler fully stainless steel, electric driven single phase having storage capacity 80 litre and nominal cooling capacity 40 litre per hour mounted on locatiion as directed complete including connecting and making electric complete all as specified and as directed.
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized 230 Volt with accuracy of +/- 2.5% of capacity 1 KVA, complete all as specified and as directed.
Desert Cooler electric driven (230 Volt, AC, 50 Hz) having nominal air flow capacity not less than 4000 cubic metre per hour, factory made GI sheet body 18 SWG & side panels of 22 SWG, water sump capacity not less than 80 litre with provision for fixing float valve and backup water connection pipe fixed at site complete all as specified and as directed.
Desert Cooler electric driven (230 Volt, AC, 50 Hz) having nominal air flow capacity not less than 3000 cubic metre per hour, factory made GI sheet body 18 SWG & side panels of 22 SWG, water sump capacity not less than 80 litre with provision for fixing float valve and backup water connection pipe fixed at site complete all as specified and as directed.
SUBTOTAL
SCHEDULE 'A' SECTION - XIV (EARTH WORKS )
Lump sum price worked out by the tenderer for “EARTH WORKS” as listed in Schedule ‘A’ Section -XIV
SOM BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .