| 1 | L1₹35.9 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹38.4 L+₹2.5 L (6.96%)Rejected-AOC | L2 | Rejected-AOC Not accepted | |
| 3 | L3₹40.4 L+₹4.5 L (12.5%)Rejected-AOC | L3 | Rejected-AOC Not accepted |
Tender Value
₹45.6 L
EMD Value
₹91,500
Closing Date
20 Jan 2021, 6:00 pmClosed
CWE PANAGARH
HQ CWE PANAGARH, DIST-BURDWAN, WB-713420
SPECIAL REPAIR / REPLACEMENT OF LT FEEDER PILLAR BOX AND ALLIED WK AT POWER HOUSE NO 2 AREA UNDER GE PANAGARH
2020_MES_406645_1
8664/E8
Open Tender
Civil Works
Item Rate
180 days
Panagarh
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE PANAGARH
₹91,500
10 Feb 2021
24 Dec 2020
22 Jan 2021
24 Dec 2020
20 Jan 2021
8 Jan 2021
Amount
Excavation in trenches not exc 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil , complete all as specified and as directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soft/loose soil , complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point , complete all as specified and as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying and punned down to a thickness of 18 cm, complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for laying Fly Ash bricks of size 23X11X7 cm for cable protection, complete all as specified and as directed.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 400 Sqmm 3.5 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 300 Sqmm 3.5 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 185 Sqmm 3.5 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 150 Sqmm 3.5 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 120 Sqmm 3.5 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 95 Sqmm 3.5 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 70 Sqmm 3.5 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 50 Sqmm 3.5 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 35 Sqmm 3.5 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 25 Sqmm 4 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 16 Sqmm 4 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 16 Sqmm 2 core cable, 1100 volts grade, laid in trenches,on pole or passing through pipe including jointing & testing , complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be included in the quoted rate.
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 240-300 Sqmm 4 Core including testing after jointing, complete all as specified & as directed.
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 150-185 Sqmm 4 Core including testing after jointing, complete all as specified & as directed.
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 70-120 Sqmm 4 Core including testing after jointing, complete all as specified & as directed.
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 25-50 Sqmm 4 Core including testing after jointing, complete all as specified & as directed.
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 6-16 Sqmm 4 Core including testing after jointing, complete all as specified & as directed.
Schedule of Credit
BANSAL CONSTRUCTION
M/S SAIMON ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .