| 1 | L1₹27.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹30.6 L+₹2.4 L (8.42%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹30.7 L+₹2.5 L (8.78%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹31.3 L+₹3.1 L (10.9%)Rejected-Finance 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹31.8 L+₹3.6 L (12.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
1 Oct 2020, 6:00 pmClosed
GE WEST ALLAHABAD
GE WEST NEW CANTT ALLAHABAD
REPAIR / MAINT OF INTERNAL ELECTRIFICATION AT NEW CANTT ALLAHABAD
2020_MES_371411_2
8922/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
NEW CANTT
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹60,000
Yes
13 Nov 2020
17 Sept 2020
3 Oct 2020
17 Sept 2020
1 Oct 2020
25 Sept 2020
Amount
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. including accessories including making good disturbed surface to match the existing complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) along with same size and type of wire as continuous earth wire connected to common earth dolly drawn in and including non metallic PVC casing and caping not less than 20mm wide med grade ISI marked complete with all fixing accessories including factory made pressed steel concealed terminal box of required size of 1.2mm thick duly painted with 3mm thick plastic laminated sheet top cover with brass screw and cup washers complete all as specified and directed for the following :- .
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane
(c) One point for socket outlet 5 amps on independent board but below the switch board in same vertical /horizontal plane
(d) One point for socket outlet 5 amp same board
(e) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade surface conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all acessories and making good to disturbed surfaces complete all as specified and directed for the following :-
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane
(c) One point for socket outlet 5 amps on independent board but below the switch board in same vertical /horizontal plane
(d) One point for socket outlet 5 amp same board
(e) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade conceal conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all acessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :-
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane
(c) One point for socket outlet 5 amps on independent board but below the switch board in same vertical /horizontal plane
(d) One point for socket outlet 5 amp same board
(e) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board
S&F ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F angle/batten type holder insulated body with back plate suitable for light point complete all as specified and directed.
Supply & fixing lamp holder adopter, two pin, insulated bakelite body for proper connection to light fitting/fixture from light point complete all as specified and directed.
S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection complete complete all as specified and directed.
S&F switch piano flush type, 6 amps, 230V AC,single pole, one way complete all as specified and directed.
S&F switch piano flush type 16 amps, 230V AC single pole one way complete all as specified and directed.
S&F bell push piano flush type 5 amp, SP , 230V AC complete all as specified and directed.
S&F socket out let multipurpose suitable for 5 pin, 6 amp flush type complete all as specified and directed.
S&F socket out let multipurpose type of 6 pin, 16 amp flush type complete all as specified and directed.
S&F call bell, ding dong type, AC, 230 V, single pole complete all as specified and directed.
S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 25 amps, C series 240 volts AC complete all as specified and directed.
S&F in replacement of switch modular flush type 10 amps, single pole, one way 230 volt complete all as specified and directed.
S&F in replacement of switch modular flush type 20 amps, single pole, one way ,230 volt complete all as specified and directed.
S&F in replacement of r bell push modular flush type 10 amp 230 volt complete all as specified and directed.
S&F in replacement of socket modular flush type suitable for 10 amp, 5 pin ,230 volt complete all as specified and directed.
S&F in replacement of socket modular flush type suitable for 20 amp, 6 pin ,230 volt complete all as specified and directed.
S&F in replacement of fan regulator, modular type, 5 stepped, electronic type, single phase 230 volt including connection complete all as specified and directed.
S&F in replacement of pressed steel terminal boxes made out of 1.2mm thick mild steel sheet, 60 mm deep including cutting on sheet and fixing existing switches, sockets, fan regulator, etc. alongwith 3mm thick plastic laminated sheet cover, fitted with cadmium plated screw washer and cutting/chasing as required in brick wall to recess the same including making good to disturbed surface with cement mortar ratio 1:4 and treated the surface with existing white/colour wash/distemper etc to match with existing surface complete all as specified and directed.
(i) 100 mm x 100 mm
(ii) 200 mm x 150 mm
(iii) 200 mm X 250 mm
Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories complete all as specified and directed.
M&L for two single core (submain) FRLS PVC insulated cable with 2.5 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM.
M&L for two single core (submain) FRLS PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4.0 sqmm stranded copper conductor earth continuity cable drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM.
M&L for two single core (submain) FRLS PVC insulated cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 6 sqmm stranded copper conductor earth continuity cable drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
M&L for two single core (submain) FRLS PVC insulated cable with 10 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS PVC insulated 10 sqmm stranded copper conductor earth continuity cable drawn in and including non metallic, medium duty, rigid PVC conduit not less than 25 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfaces complete all as specified and directed.
S&F sheet metal enclosure for MCB's 240 volt 4 way single pole and neutral with 200 amps rated busbar double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed. Make-Indo Asian/Standard/Havells/HPL or as approved.
S&F sheet metal enclosure for MCB's 240 volt 6 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed. Make-Indo Asian/Standard/Havells/HPL or as approved.
S&F sheet metal enclosure for MCB's 240 volt 8 way single pole and neutral with 200 amps rated busbar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed. Make-Indo Asian/Standard/Havells/HPL or as approved.
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed. Make-Indo Asian/Standard/Havells/HPL or as approved.
S&F MCB single pole & Neutral, 40 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed. Make-Indo Asian/Standard/Havells/HPL or as approved.
S&F MCB single pole & neutral 63 amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed. Make-Indo Asian/Standard/Havells/HPL or as approved.
S&F in replacement of MCB tripple pole & neutral 63 amp, 415 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed. Make-Indo Asian/Standard/Havells/HPL or as approved.
Taking down existing old /worn out tube/CFL/bulk head/sketch light fittings of indoor type fixed on wall of any type/size with its all accessories including lamp complete all as specified and directed.
Supply & fixing surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make - Philips/Havells/Wpro or as approved.
Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make - Philips/Havells/Wpro or as approved.
Supply & fixing energy efficient LED Bulkhead in high pressure die cast aluminium housing of system wattage - 6.5 Watt, lumen out put - 700 Lm, colour Temp - 6500 K having Ingress protection - IP 65 fpr dust, water & IK 08 for external impact complete all as specified and directed. Make - Philips/Havells/Wpro or as approved.
S&F in replacement of worn out/old linear fluorescent tube of 36 watt with energy efficient/saving retrofit LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm or above, Colour Temp - 6500 Kelvin, Size & Length - G13/T8/4 Feet, Operating Voltage - 230 Volt AC, THD ≤ 20 % with intergral/in built driver, having short circuit and surge protection upto 4 KV and other safety test as per IS 15885 Part 2/Sec 13 including making minor addition/alteration in existing circuit as required complete all as specified and directed. Make - Philips/Havells/Wpro or as approved.
Supply & fixing in replacement of worn out 36 watt FPL with retro fit linear LED PLL lamp and PC diffuser complete with inbuilt electronic driver of high efficacy of system wattage 18 Watt, Length - 419 mm, Lumen out put - 1800 Lm or above, Colour Temp - 6500 K suitable for installation in existing 2G11 lamp holders including minor aleration in existing circuit as required complete all as specified and directed. Make - Philips/Havells/Wpro or as approved.
S&F in replacement of existing worn out ceiling light with recessed mounted LED light luminaries of size 600 mm x 600 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make - Philips/Havells/Wpro or as approved.
S&F in replacement of existing worn out spot light 7watt of 100mm dia with Recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with LEDs, in built electronic LED driver and accessories pre-wired up to terminal block including making connection complete all as specified and directed. Make - Philips/Havells/Wpro or as approved.
S&F in replacement of existing worn out spot light 10watt of 90mm dia with Recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with LEDs, in built electronic LED driver and accessories pre-wired up to terminal block including making connection complete all as specified and directed. Make - Philips/Havells/Wpro or as approved.
S&F in replacement of existing worn out spot light 15watt of 155mm dia with Recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with LEDs, in built electronic LED driver and accessories pre-wired up to terminal block including making connection complete all as specified and directed. Make - Philips/Havells/Wpro.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt , PCC pit in 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC cover in 1:2:4 type BO using 20mm graded stone aggregate re-inforced with 8 mm dia MS TMT bars @ 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
P S TRADERS
Channa Brothers and Co.
M/s RAM LAKHAN GUPTA
M/S NAGENDRA AND BROS ENTERPRISES
Technological Associates
M/S CHANDRIKA PRASAD AND SONS
M/s SINGH CONTRACTOR WORKS
M/S Arjun Enterprises
SRI HARSHITA ELECTRICALS
sethi tradres
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .