Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹28.1 L+₹33,814.11 (1.22%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹29.9 L+₹2.2 L (7.74%)Rejected-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹34.7 L+₹6.9 L (25.0%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹35.4 L+₹7.6 L (27.4%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L5 | Rejected-AOC REJECTED |
Tender Value
₹43.9 L
EMD Value
₹87,800
Closing Date
26 Feb 2024, 6:00 pmClosed
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
REPAIR REPLACEMENT OF LT PANELS CABLES, STREET LIGHT DG SET AND OTHER MISC AND ALLIED EXTERNAL ELECTRIFICATION ITEMS AT NCHC POWAI AND ULHASNAGAR UNDER GE(NW) BHANDUP
2023_MES_634294_2
8310/B
Open Tender
Civil Works
Item Rate
270 days
POWAI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE(NW) BHANDUP
₹87,800
Yes
24 Jun 2024
12 Feb 2024
27 Feb 2024
12 Feb 2024
26 Feb 2024
19 Feb 2024
12 Feb 2024 - 19 Feb 2024
Amount
Taking down unsv LED street light fitting and Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple opticsIP66 protection ,PF > 0.95, LED Luminous efficiency shall not be less than 90 Lumens per Watt and color rendering index shall not be less than 70, correlated color temperature is 6500K and Luminous should be complying ISI and BIS Marking complete all as per specified and directed.
Taking down unsv LED street light fitting and Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics IP66 protection ,PF > 0.95, LED Luminous efficiency shall not be less than 90 Lumens per Watt and color rendering index shall not be less than 70, correlated color temperature is 6500K and Luminous should be complying ISI and BIS Marking complete all as per specified and directed.
Taking down unsv LED street light fitting and Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics IP66 protection ,PF > 0.95, LED Luminous efficiency shall not be less than 90 Lumens per Watt and color rendering index shall not be less than 70, correlated color temperature is 6500K and Luminous should be complying ISI and BIS Marking complete all as per specified and directed.
Supply and fixing LED flood light 200/210 watt 230 V AC outdoor type with thermal management in multiple optics IP66 protection ,PF > 0.95, LED Luminous efficiency shall not be less than 90 Lumens per Watt and color rendering index shall not be less than 70, correlated color temperature is 6500K and Luminous should be complying ISI and BIS Marking and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as per specified and directed.
Taking down unsv LED security light fitting and Supply and fixing LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics IP66 protection ,PF > 0.95, LED Luminous efficiency shall not be less than 90 Lumens per Watt and color rendering index shall not be less than 70, correlated color temperature is 6500K and Luminous should be complying ISI and BIS Marking complete all as per specified and directed.
Supply and drawing through conduit pipe on pole/ wall for making connection to the light fittings 3 Core, Copper cable,PVC insulated and sheathed heavy duty 1100 volt grade multi stranded copper conductor (FRLS) cable 1.5 Sqmm complete all specified and directed
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 155 x 155 x100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for Three phase and neutral (Four terminals) for cable in cable out entire complete. Terminal box to be fixed to wall/ Pole complete all as per specified and directed.
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 250 x 250 x105 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for Three phase and neutral (Four terminals) for cable in cable out entire complete. Terminal box to be fixed to Pole complete all as per specified and directed.
Supply and fix in repairs pipe bracket made out of 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Supply and fix in repairs pipe bracket made out of 25 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Taking down unserviceable LT cable complete all as specified and directed
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as per specified and directed.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as per specified and directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as per specified and directed.
Supplying and laying High density polyethylene pipes (DWC HDPE Pipe) of pressure rating 6 kgf/cm2 of 50 mm inner bore pipe laid in trenches for cable protection complete all as specified and directed.
Supplying and laying High density polyethylene pipes (DWC HDPE Pipe of size 32mm inner dia) of pressure rating 6 kgf/cm2 of 32 mm dia bore of pipe laid in trenches for cable protection complete all as per specified and directed.
S&F in repairs of GI pipe 100 mm dia light grade with all fittings for cable protection complete all as specified and directed.
S&F in repairs of GI pipe 80 mm dia light grade with all fittings for cable protection complete all as specified and directed.
S&F in repairs of GI pipe 50 mm dia light grade with all fittings for cable protection complete all as specified and directed.
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation filling & mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in coping / fountation of poles including use of form work and finishing all exposed faces of concrete as per clause 4.11.66 (a) & (d) of SSR Part-I complete all as specified and directed.
Supply and fixing in repairs analog timer switch 3P module, 24 Hrs preprogram complete all as specified and directed
M&L for LT straight through joint heat shrinkable kit suitable for 3 ½ / 4 core of size 10 to 16 sqmm underground cable all as specified and directed.
All as per item no.24 above but 25 to 50 sqmm
All as per item no.24 above but 70 to 95 sqmm
All as per item no.24 above but 120 to 185 sqmm
All as per item no.24 above but 70 to 120 sqmm
All as per item no.24 above but 150 to 185 sqmm
S&F 7 meter long hot dipped galvanized octagonal poles with top A/F 70 mm bottom A/F 130 mm ,made out of 3 mm thick HT sheet along with base plate of size 220x220x12mm ,including 1500 mm long single/double arms bracket made out of 48 mm dia,GI pipe,M20 in PCD 205 mm,700mm long and projected 100mm,"J" type EN8 grade set of 4 Nos foundation bolts along with templates,also including provision of the followings :- a)MCB,SP,6A,230v,B series,10KA mounted on and including 3 mm thick plastic laminated sheet-01 No. b) 4 way connector ,bolt type having locking arrangement,weather proof and water proof control space: 01 No. Notes :- a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete. b) The rate quoted shall also be deemed to include the cost for connecting with including suitable lugs of the existing incoming and outgoing LT UG cable of any size in the pole box of new octagonal pole. c) The concrete for foundation ,Reinforced and form work will measured and paid separately. d) The existing light fittings retrieved from item No 01 here in before shall be re fixed at the pole and the quoted rate shall also be deemed to include the cost of above mentioned element. e) The excavation and earth work for foundation of pole shall be measured and paid separately in case the new poles are provided at different locations as compared to old poles dismantled vide item no 1 here in before.
M&L for TMT steel bars 10 mm dia and over in reinforcement cut to length,bent to shape required,including cranking bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm di or encuring with clips etc, complete all as specified and directed
M&L for TMT steel bars 6 to 8 mm dia as in stirrups, spacers, binders cut to length,bent to shape required,including cranking bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm di or ecuring with clips etc, complete all as specified and directed
M&L for Carrying out 'B' check for 200 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost excluding spares and Engine oil.
All as per item No 35. above but 160 KVA capacity
All as per item No 35. above but 125 KVA capacity
All as per item No 35. above but 100 KVA capacity
All as per item No 35 above but 82.5 KVA capacity
All as per item No 35 above but 75 KVA capacity
All as per item No 35 above but 50 KVA capacity
All as per item No 35 above but 45 KVA capacity
All as per item No 35 above but 7.5 KVA capacity
Supply only Engine oil grade 20 W 40 for incorporation against "B" check complete all as specified and directed.
Supply only coolant for DG set radiator complete all as specified and directed.
Supply only Electrolite cum distiled water suitable for lead acid battery complete all as specified and directed.
Supply only fuel filter & oil filter suitable for 200 KVA DG set capacity as per existing size complete all as specified and directed.
All as per item No 47. above but 160 KVA capacity
All as per item No 47. above but 125 KVA capacity
All as per item No 47. above but 100 KVA capacity
All as per item No 47 above but 82.5 KVA capacity
All as per item No 47 above but 75 KVA capacity
All as per item No 47 above but 50 KVA capacity
All as per item No 47 above but 45 KVA capacity
All as per item No 47 above but 7.5 KVA capacity
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 200 KVA DG set complete all as specified and directed.
All as per item No 56. above but 160 KVA capacity
All as per item No 56. above but 125 KVA capacity
All as per item No 56. above but 100 KVA capacity
All as per item No 56 above but 82.5 KVA capacity
All as per item No 56 above but 75 KVA capacity
All as per item No 56 above but 50 KVA capacity
All as per item No 56 above but 45 KVA capacity
All as per item No 56 above but 7.5 KVA capacity
S&F in repairs of fan belt suitable for DG set of 45 to 200 KVA capacity complete all as specified and directed.
S&F in repairs of fan belt suitable for DG set 7.5 KVA capacity complete all as specified and directed.
M&L for Draining the fuel from existing diesel tank in a separate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 200 KVA Capacity.
All as per item No 67. above but 160 KVA capacity
All as per item No 67. above but 125 KVA capacity
All as per item No 67. above but 100 KVA capacity
All as per item No 67 above but 82.5 KVA capacity
All as per item No 67 above but 75 KVA capacity
All as per item No 67 above but 50 KVA capacity
All as per item No 67 above but 45 KVA capacity
All as per item No 67 above but 7.5 KVA capacity
M&L for Repairing radiator for 160 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and re fixing on the chasses complete all as specified and as directed.
All as per item No 74 above but 82.5 KVA capacity
All as per item No 74 above but 75 KVA capacity
S&F in repairs solenoid switch for DG set upto 200 KVA capacity complete all as specified and directed by Engg-in Charge
M&L for Repairs AMF Panel of 160/200 KVA DG set as per the site requirement complete all as specified and as directed by Engg-in Charge
Material and labour for disconnecting / dismantling of self starter from DG set 82.5 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc, greasing and connecting , testing complete all as specified and as directed.
All as per item No 79 above but 75 KVA capacity
All as per item No 79 above but 50 KVA capacity
Material and labour for servicing and overhauling of dynamo including replacement of unsv parts such as carbon brush, armature winding, varnishing of coil and reassembling and fitted with the engine including testing complete of capacity 12 volts complete all as specified and directed.
Material and labour for painting of DG sets of 75 KVA including alternator, fuel tank complete with all accessories by scrapping thoroughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Supply and fix in repair unserviceable Maintenance free battery 150 Ah 12 volts complete all as specified and directed.
Supply and fix in repair unserviceable battery lead copper lead of 25 Sqmm copper conductor, 2 Mtr length with brass terminal complete suitable for DG set 7.5 KVA to 160 KVA complete all as specified and directed.
Dismantling and calibrating the fuel injector assembly from authorized dealer of capacity 82.5 KVA DG set complete all as specified and directed
All as per item No 86 above but 160 KVA capacity
All as per item No 86 above but 75 KVA capacity
Taking out unserviceable LT cable complete all as specified and directed
Supply and laying in repair cable XLPE insulated, armored heavy duty electric cable, galvanized steel strip or wire armored, with aluminum conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm x 4 core complete all as per specified and directed.
All as per item no.90 above but 16 sqmm 4 core
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm x 3.5 core
All as per item no.92 above but 35 sqmm, 3.5 core
All as per item no.92 above but 50 sqmm, 3.5 core
All as per item no.92 above but 95 sqmm, 3.5 core
All as per item no92 above but 120 sqmm, 3.5 core
All as per item no.92 above but 150 sqmm, 3.5 core
All as per item no.92 above but 185 sqmm, 3.5 core
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge.
Supply and spreading River sand in trenches as cushioning to under ground cable on top and bottom of cable complete all as specified and directed.
Supply and fix in replacement of thermal based MCCB 125 Amps 4 Pole, with breaking capacity 16 KA, as per site requirement and complete all as specified and directed.
Supply and fix in replacement of thermal based MCCB 100 Amps 4 Pole, with breaking capacity 16 KA, as per site requirement and complete all as specified and directed.
Supply and fix in replacement of thermal based MCCB 160 Amps 4 Pole, with breaking capacity 36 KA, as per site requirement and complete all as specified and directed.
Supply and fix in replacement of thermal based MCCB 200 Amps 4 Pole, with breaking capacity 36 KA, as per site requirement and complete all as specified and directed.
Supply and fix in replacement of thermal based MCCB 250 Amps 4 Pole, with breaking capacity 36 KA, as per site requirement and complete all as specified and directed.
Supply and fix in replacement of thermal based MCCB 100 Amps 3 Pole, abjustable type, 50Hz with breaking capacity 16 KA, as per site requirement with sheet metal enclosure and complete all as specified and directed.
Disconnecting the incoming and out going cable connection and dismantling the unserviceable LT outdoor panel . Design fabricating supplying and fixing Outdoor type LT panel for 01 incomer and 06 nos outgoing MCCB mounting, vermin, dust and weather proof totally inclosed cubical type front operated double door separate compartment fabricated out of 3 mm thick CRCA sheet duly treated with seven tank process and painted epoxy powder coated siemens gray colour and with industrial type built in locking arrangement. The meter box shall be factory made from a reputed panel fabricators (CPRI approved manufacturers). The panel shall be floor mounting type and to be fixed with all necessary fixing arrangements such as angle iron brackets and frame or iron angles not less than 3 mm thick. The panel to be prewired with suitable size PVC insulated copper conductors or copper strip for monitors and Copper busbar with heat shrinkable sleeves of capacity 600 Amps for connecting the incoming MCCB and out going MCCB and including digital type multifunction meter and phase indicator with the following items complete all as specified (Near building 174 & E) (a) Aluminium busbar 1000 Amps for phases and neutral duly sleeved with heat shrinkable insulation using colour code for R Y B &N set of 4- 01 Set. (b) MCCB, 4 Pole, 600 Amps 415 Volts Thermal based, 36 KA- 01 No ( Incomer) (c) MCCB, 4 Pole, 100 Amps 415 Volts Thermal based, 16 KA- 01 No( Outgoing) (d) Indicator lamp complete with lamp holder LED type set of 03-01 set (Red, Yellow and Blue) (e) VAF+ PF meter CL-0.5, input Voltage-50-520 VAC, CT 1A/5 A, Parameter VLL,VLN,A, F& PF digital type meter of size 96mm x 96mm - 01 No
M & L for painting of synthetic enamel paint for panel board other MS steel surface, preparation oil painted surface by scratching and apply one coat of red oxide and one coat of synthetic enamel paint and complete all as specified and directed
M&L for Surface dressing n. exc 15 cm of surrounding area of power house, LT panel and any out door installation in soft/ loose soil (including bush Cutting)complete all as specified and directed
M & L for Structural steel, rolled section such as joist, beam, channel, angle, Tee, in available lengths for structural farm of panel complete all as specified and directed
M&L for finding faults of LT UG XLPE cable of any size and any length upto 240 Sqmm by using computerized / primary current injection method / any other method as directed by the Engr-in-charge and locating fault, cutting and removing the faulty portion of the cable and jointing with suitable cable joint including exaction, refilling and testing after jointing all as required and directed. Note: Joints shall be paid for separately.
M&L Earthing complete with galvanized steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanized earth lead strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed
Taking down old unserviciable security / street light fittings and from the pope/ wall/ post top repair/ replacement of burnt / worn out accessories and refixing the same in position including testing after repair including spare like lugs, nut bolt with washers complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 90,170.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
R J ENTERPRISES
Chakshu Enterprise
NOEL ENGINEERS
joshua construction
the bhimani group of companies
Anjali Constructions
Bikarma Enterprise
M/s Qureshi Construction Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .