| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Quoted Rate | |
| 2 | L2₹13.4 L+₹14,595 (1.10%)Rejected-AOC | L2 | Rejected-AOC Highest quoted rate | |
| 3 | L3₹13.6 L+₹29,796.25 (2.24%)Rejected-AOC | L3 | Rejected-AOC Highest quoted rate |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Ravinder Kumar AGE CONTRACTS
GE (S) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
Comprehensive repair to upkeep and maint of sewage network at South of MIRC under GE (S) Ahmednagar
2020_MES_397536_1
8758/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
AHMEDNAGAR
Class E cat a (ii)
7 documents required · 7 mandatory
₹500
Garrison Engineer (S) Ahmednagar
₹40,000
Yes
3 Mar 2021
23 Nov 2020
24 Dec 2020
23 Nov 2020
22 Dec 2020
8 Dec 2020
23 Nov 2020 - 1 Dec 2020
60 days
Amount
Excavation in trenches for foundations not exc 1.5 m deep & not execeding 1.5m wide in soft/loose soil and getting out complete all as specified and directed.
Demolition and breaking up drain pipes 150 mm bore (salt glazed or RCC) set in cement mortar complete all as specified and directed.
All as per serial item No. 02 here-in-before but 200 mm bore pipes.
All as per serial item No. 02 here-in-before but 300 mm bore pipes.
150 mm internal dia Reinforced concrete pipes with collars, of approved make , class NP3, laid and jointed with cement joint complete all as specified & directed.
All as per serial item No. 05 here-in-before but 200 mm internal dia pipes.
300 mm internal dia Reinforced concrete pipes with collars, of approved make , class NP2, laid and jointed with cement joint complete all as specified & directed.
PCC 1:4:8, type D-2, using 40 mm gde stone aggregate as in concrete bed to drain pipes 150 mm bore including packing under and hunching against the sides of pipes after they are laid & tested complete all ass pecified and directed.
All as per serial item No. 08 here-in-before but 200 mm bore pipes.
All as per serial item No. 08 here-in-before but 300 mm bore pipes.
PVC (SWR),pipes of 75 mm bore single socketed in any length with rubber ring joints fixed to walls as in repairs, complete all as specified and directed.
PVC (SWR) pipes of 110 mm bore single socketed in any length with rubber ring joints fixed to walls as in repairs, complete all as specified and directed.
PVC (SWR) bends any radious with access door of 110 mm bore,fixed in repairs complete all as specified and directed.
PVC (SWR) bends any radious with access door of 75 mm bore,fixed in repairs complete all as specified and directed.
PVC (SWR) junction of 110 mm bore single, (single T) equal or unequal with access door, fixed in repairs, complete all as specified and directed.
PVC (SWR) junction of 75 mm bore single, (single T) equal or unequal with access door, fixed in repairs, complete all as specified and directed.
PVC (SWR) branch piece of 110 mm bore doube, (double Y) , fixed in repairs, complete all as specified and directed.
PVC (SWR) branch piece of 75 mm bore doube, (double Y) , fixed in repairs, complete all as specified and directed.
PVC (SWR) junction of 110 mm bore single, (single T) equal or unequal with access door, fixed in repairs, complete all as specified and directed.
PVC (SWR) junction of 75 mm bore single, (single T) equal or unequal with access door, fixed in repairs, complete all as specified and directed.
PVC (SWR) reducer 110 mm bore, fixed in repairs, complete all as specified and directed.
PVC (SWR) 110 mm bore vent cowl fixed in repairs, complete all as specified and directed.
PVC (SWR) 75 mm bore vent cowl fixed in repairs, complete all as specified and directed.
PCC 1:4:8, type D2 using 40 mm graded stone aggregate as in foundation of manholes complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description in any position not otherwise specially provided for complete all as specified and directed.
Reinforced cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in precast manhole cover slabs including necessary form work complete all as specified and directed.
Demolition of PCC solid block masonry built in cement mortar as in manholes etc. above or below GL in foul conditions or in any other condition complete all as specified and directed.
Precast cement concrete solid block masonry 1:5:8 exceeding 10 cm thickness/width built in CM 1:6 complete all as specified and directed.
Cement concrete 1:3:6, type C2 using 40 mm graded stone aggregate as in surface channel & drains complete all as specified and directed..
Cement concrete 1:3:6, type C1 using 20 mm graded stone aggregate as in coping of manholes or the like including necessary form work complete all as specified and directed.
Forming fair finished drains or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered/stopped ends etc. complete all as specified and directed.
Rendering 15 mm thick in CM 1:4 on concrete surface work including finishing the surfaces even & smooth with using extra cement complete all as specified and directed.
Labour only for cleaning the surrounding areas of filter bed & septic tank including removal of bushes, grass etc. along the perimeter (inside & outside of filter bed) complete all as directed.
Labour only for removing blockage of WC (Indian or EWC), urinal, bath and kitchen, gully trap including cleaning of pan, floor trap and removing blockage of down pipe upto1st manhole complete all as specified and directed. Note;(a) The item shall be operated on demand/complaint of users and shall be executed on specific written direction of JE/AGE .(b) All written docket shall be serially numbered, jointly signed including the USER with bldg./Qtr No and entered in MB for the purpose of measurement and payment.(c) A recovery of Rs.200/-shall be levied as panalty from the contractor if the complaints are not done within 24 Hrs.Decision of GE in this regard shall be final and binding. Document in support of satisfatory completion of each complaint shall be preserved by contractor and submitted for verification.
Cutting into existing manhole for connecting new drains making good to pipes & rendering, cutting out existing benching & forming branch channel 01, ½ round or ¾ section in PCC 1:2:4 type B1, smooth finished for 150 mm bore pipe complete all as specified and directed.
Loose filling with broken bricks of gauge 80 to 150 mm in soakage pit , soakage wells complete all as specified and directed.
Cleaning of existing SWG/RCC pipe line of 100 mm to 150 mm bore between the manholes by mechanical operated machine for removing blockage, debris from pipes taking out the blocked sludge debris etc collected in the manholes from pipe , cleaning & depositing sludge/debries to excavated area, spreading necessary insectcise where sludge is deposited all as specified and directed by Engineer-in-charge.(All sludge/debris should be deposited in nearest pit & cover with sand & necessary disinfection be carried out) (Note :- Rs 300.00 for each complaint shall be deducted from the payment of contractor in case complet is not rectified within 24 hours since ordered)
All as per item No. 39 here-in-before but 200 mm & 250 mm bore pipes.
All as per item No. 39 here-in-before but 300 mm & 450 mm bore pipes.
Dewatering of sludge & removing the sludge from septic tank of capacity 25 to 50 users, cleaning the septic tank with water & removing the sludge outside the MD land & depositing, to carry out necessary disinfection where sludge is deposited all as specified and directed by Engineer-in-Charge for septic tank of following capacity :-(Note:- Rs 200.00 for each complaint shall be deducted from the payment of contractor if the complaint is not done within 24 hours)
All as per item No. 42 here-in-before but septic tank of capacity 100 to 150 users.
All as per item No. 42 here-in-before but septic tank of capacity 200 to 500 users.
Excavation over areas, n exc 1.5 m deep and getting out in soft loose soil complete all as specified and directed.
Excavating over areas, exceeding 1.5 m deep but n exc 3 mtr and getting out in soft loose soil complete all as specified and directed.
Returning, Refilling incl spreading, leveling, watering & well ramming in layers n exc 25 cm complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed the starting point in soil complete all as specified and directed.
Ms. D.G. SHIRKE
M.H Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .